Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC tenderaccepted | |
| 2 | L2₹19.0 L+₹2.6 L (15.9%)Rejected-Finance | L2 | Rejected-Finance not being L1 | |
| 3 | L3₹19.7 L+₹3.3 L (20.2%)Rejected-Finance | L3 | Rejected-Finance not being L1 | |
| 4 | L4₹20.6 L+₹4.1 L (25.2%)Rejected-Finance D 65 423 C 1 RANA NAGAR COLONY GATE NO 4 LAHARTARA VARANASI UP PIN 221106 | VARANASI | VARANASI | UTTAR PRADESH | 221106 | L4 | Rejected-Finance not being L1 | |
| 5 | L5₹20.9 L+₹4.5 L (27.2%)Rejected-Finance | L5 | Rejected-Finance not being L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
9 Mar 2020, 6:00 pmClosed
GE Faizabad
GE MES Faizabad
REPAIR MAINT OF CI GI PIPE LINE VALVES AND ALLIED WORKS UNDER AGE EM AT GE FAIZABAD
2020_MES_325125_1
8942/E8
Open Tender
Civil Works
Item Rate
150 days
Faizabad
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE Faizabad
₹50,000
Yes
29 Apr 2020
14 Feb 2020
10 Mar 2020
14 Feb 2020
9 Mar 2020
24 Feb 2020
Amount
Taking out steel water tubing including fittings of 15mm bore complete all as specified and directed. ( Note- Excavation & earth work shall be measured and paid separately)
All as per item no. 1 but of 20mm bore
All as per item no. 1 but of 25mm bore
All as per item no. 1 but of 40mm bore
All as per item no. 1 but of 50mm bore
All as per item no. 1 but of 80mm bore
S&F GI pipe medium grade with all fittings and fixed of 15 mm bore complete to wall/ceiling or laid in floor /trenches etc. complete all as specified and directed .
All as per item no. 7 but of 20mm bore
All as per item no. 7 but of 25mm bore
All as per item no. 7 but of 40mm bore
All as per item no. 7 but of 50mm bore
All as per item no. 7 but of 80mm bore
Refixing old steel tubing and connections in new or old position (Walls, ceiling,floors, etc.) including cleaning of pipes of 15mm bore all as specified and directed by EIC.
All as per item no. 13 but of 20mm bore
All as per item no. 13 but of 25mm bore
All as per item no. 13 but of 40mm bore
All as per item no. 13 but of 50mm bore
All as per item no. 13 but of 80mm bore
M&L for rectification of leakage from GI Pipe line joints including excavation, returning and filling etc including providing new fittings like unions, sockets, bends, elbows, tees, nipples etc as required complete all as specified of 50mm bore.
All as per item no. 19 but of 40mm bore
All as per item no. 19 but of 25mm bore
All as per item no. 19 but of 20mm bore
S&F gun metal globe or gate valve 'ISI marked' with iron wheel head screwed both end for iron pipe all as per latest IS specifications of 15mm bore complete all as specified.
All as per item no. 23 but of 20mm bore
All as per item no. 23 but of 25mm bore.
All as per item no. 23 but of 40mm bore
All as per item no. 23 but of 50mm bore
Cutting in position existing steel tubing for alteration or additions complete all as directed of 20mm bore.
All as per item no. 28 but of 25mm bore
Screwing existing steel tubing of 20mm bore for alterations or additions (or lengthening) screw on pipe to form connector complete all as specified.
All as per item no. 30 but of 25mm bore
Taking up underground cement pipe/ CI water mains (including all fittings ) of 80mm bore complete all as specified. (Note - Excavation& earth work shall be measured and paid seperately) :-
All as per item no. 32 but of 100mm bore
All as per item no. 32 but of 150mm bore
Supplying & laying ductile iron pipes spigot & socket class K-7 'ISI marked' in any length laid in trenches of 100mm nominal bore all as specified and directed by EIC. (Note - Joint shall be measured and paid seperately).
All as per item no. 35 but of 150mm nominal bore
Relaying cast iron pipes spigot and socketed ends centrifugally casted class A 'ISI marked' in any length laid in trenches including cleaning of pipe of 80mm nominal bore all as specified and directed by EIC. (Note - Joint shall be measured and paid seperately).
All as per item no. 37 but of 100mm nominal bore
All as per item no. 37 but of 150mm nominal bore
M&L in repair run lead joints for spigot and socket ends for fittings/water mains in repair for new/old pipe lines and fittings of 80mm bore complete all as specified and directed.
All as per item no. 40 but of 100mm bore
All as per item no. 40 but of 150mm bore
M&L for rectification of leakage CI pipe line of 80mm bore including excavation and earth work and caulking with the pig lead complete all as directed.
All as per item no. 43 but of 100mm bore
All as per item no. 43 but of 150mm bore
M&L in repairs flanged joints for 80mm bore pipe complete with rubber or fibre board gasket for new/old pipe lines including nut bolts & washers etc. of water mains/fittings complete all as specified and directed
All as per item no. 46 but of 100mm bore
All as per item no. 46 but of 150mm bore
Cutting in position cast iron water mains for insertion of new tee for branch connection all as directed for 80mm bore.
All as per item no. 49 but of 100mm bore
All as per item no. 49 but of 150mm bore
Dismantling existing flanged pipe joints including removal of old rubber or fiber board gaskets,bolts and nuts etc all as specified and directed for 80mm bore pipe.
All as per item no. 53 but of 100mm bore
All as per item no. 53 but of 150mm bore
M&L CI fittings for Spigot socket/ flanged pipes bends(any type,radius and angle ) tapers any type (straight, bend, increasing, decreasing or double socket etc)Tee,pieces, single branch "Y" juction double ,cross(all sockets or socket and spigot) collar,caps and plugs up to 250mm bore complete all as specified and directed by Engr-in-charge.
M&L DI fittings for flanged/ Spigot socket pipes bends (any type,radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc)Tee,pieces, single branch "Y" juction double ,cross (all sockets or socket and spigot) collar,caps and plugs up to 150 mm bore complete all as specified and directed by Engr-in-charge.
Excavation in trenches n.exc. 1.5 mtr wide and n.exc. 1.5 mtr in depth for laying / taking out water supply pipe line in soft/loose soil, taking out excavated material,forming bottom etc complete all as specified and directed..
Returning filling in including,spreading ,levelling watering and well ramming in layer in n.exc 25 cm in soft/lose soil all as specified directed.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above starting point as in soft/loose soil complete all as specified and directed.
S&F flat three core submersible cable PVC insulated and sheathed multistranded copper conductor of cross sectional area 16 sqmm of make: Havells/ Polycab/ legrand.
Material and Labour for Mild Steel ERW (Electro Resistance Welded) pipe with flanged ends suitable for Column Pipe of bore dia 150mm ncluding taking out of old pipes all as specified and directed by EIC including taking out of old one. [Note: The pipes should be in 3.0 mtr length with both side flanged suitable for column pipe for Bore well]
Taking out unserviceable sluice valve/ butterfly valve from water mains of 80mm bore.
All as per item no. 62 but of 100mm bore
All as per item no. 62 but of 150mm bore
Supply, fix & testing sluice valve 'ISI marked' both ends flanged and drilled cast iron body class PN-1.6 conforming to IS-14846/2000 complete with gun metal spindle including necessary nut bolts and gasket etc for fixing complete all as specified and directed of 80mm bore [Note: For sluice valves fixed with pillars of over head tank, breaking of RCC/lead/ flange joints and repairing the same after fixing of valve shall be deemed to be included in the quoted rates]
All as per item no. 65 but of 100mm bore
All as per item no. 65 but of 150mm bore
All as per item no. 65 but butterfly valve of size 150mm bore.
M&L for replacing of gland packing,nut-bolts and washer of sluice valve of 80mm bore.
All as per item no. 69 but 100mm bore
All as per item no. 69 but 150mm bore
M&L for replacing of gun metal check nut of sluice valve of 80mm bore.
All as per item no. 72 but 100mm bore
All as per item no. 72 but 150mm bore
M&L for replacing of existing size gun metal spindle of sluice valve 80mm bore
All as per item no. 75 but 100mm bore
All as per item no. 75 but 150mm bore
M&L in repair for valve pit masonary chamber of size 1050x1050x1050 mm (internal dimension) with MS plate 8 mm thick top cover arrangement 50 mm lock - 01 No including painting with two coat of synthetic enamel paint over a coat of red oxide primer incuding excavation earth work, PCC plaster etc complete all as specified and directed by Engr-in-charge.
All as per item no. 78 but internal dimension 900mmx900mmx900mm.
All as per item no. 78 but internal dimension 650mmx650mmx650mm.
Super Automobiles
Sai Ram Associates
R K BROTHERS
Yadav Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .