| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAccepted-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹47.2 L+₹2.3 L (5.20%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹47.5 L+₹2.7 L (5.91%)Rejected-AOC TULSI ASTHA FLAT NO 1 PLOT NO 54 SECTOR 12 VASHI NAVI MUMBAI THANE 400 703 | THANE | MAHARASHTRA | 400703 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹47.6 L+₹2.7 L (6.01%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹48.8 L+₹3.9 L (8.67%)Rejected-AOC UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
18 Oct 2021, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD, MUMBAI-400088
DEMOLITION AND RECONST OF PERIMETER BDY WALL BEHIND P-15 AT SPDC, ADDN/ALTN AND SPECIAL REPAIRS TO GYMNASIUM T36 AT SPDC AND PROVN OF MSO, OPS ROOM AND OFFICE CUM REST ROOM AT SRU (W) OP FACILITY AT MANKHURD UNDER GE (NW) MANKHURD
2021_MES_475734_1
8093/E8
Open Tender
Civil Works
Item Rate
210 days
GE (NW) MANKHURD
AS PER TENDER DOCUMENTS AND NIT
8 documents required · 8 mandatory
₹500
GE (NW) MANKHURD
₹95,000
Yes
25 Oct 2021
16 Sept 2021
20 Oct 2021
16 Sept 2021
18 Oct 2021
12 Oct 2021
16 Sept 2021 - 11 Oct 2021
Amount
Demolition of brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc completed all as specified and directed.
Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thicknes (below or above ground level) etc and removing debris outside MD land completed all as specified and directed
Excavation in trenches n.exc 1.5 m wide and n exc 1.5 m in depth for foundation and getting out in any type of soil etc completed all as specified and directed
M & L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundation filling and mass concrete etc completed all as specified and directed
M&L for PCC 1:2:4 type B2 (using 40mm graded aggregate) as in drain,foundation filling and mass concrete etc completed all as specified and directed
M&L for walling random ruble masonry,uncoursed,well bonded,bedded and solidly hearted, built in cement and sand mortar (1:6) etc completed all as specified and directed
All as per item No 6.00 above but except stone etc completed all as specified and directed
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints,as specified,of random rubble walling,with maximum depression on face from straight edge 20mm held against the dressed surface etc completed all as specified and directed
M&L for rendering 20mm thick in CM 1:4 as stone masonary surface making surface fair & even without using extra cement etc completed all as specified and directed
M & L cement concrete type B 1 1:2:4( 20 mm graded aggregate), in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates/ blocks, water troughs and the like including weathering, slightly rounded for chamfered angles and throating etc completed all as specified and directed
Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E 165 etc completed all as specified and directed
S & F barbed razor tape concertina coil SG hot galvanized spring tensile wire to particular here-in-after or other equivalent make as approved by GE of UTS 145 to 150 kg/mm^2 and Dia of coil when unstreched 601mm having minimum number of circles 10/Rm,minimum number of clipes 25/RM and minimum weight of coil 1.625 Kg/Rm,hot dip galvanized razor ribbon tape of size 0.50mm thickness,19 mm width before wrapping on central core wire fixed with GI 1.66 mm clips and special nut bolts to hold two coils together and extra 2 rows parallel wire of 10 gauge tied by binding wire whreever etc completed all as specified and directed
M&L for Galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins, etc completed all as specified and directed
M&L for treating with tar or coal tar black paint on ends of posts area exc 0.10 Sqm but not exc 0.5 Sqm each etc completed all as specified and directed
Returning filling including spreading,levelling, watering & well ramming in layers not exc 25cm etc completed all as specified and directed
Removing of excavated material n. exc.50m depositing where directed/Incl filling the portion at disturbed area of earth etc completed all as specified and directed
M&L for PCC 1:4:8 type D-2 75 mm thick (using 40mm graded aggregate) as in sub base etc completed all as specified and directed
M&L for Machine pressed precast concrete interlocking 80mm thick precast cement grade M-35 with grey cement and pigment having compresive strength 35 N/mm2 laid with over and including sand cushinig of average thickness 25mm after consolitation set and level the tiles on proper level with interlocking etc completed all as specified and directed
M&L Pre cast cement concrete block masonry with solid blocks, exc 10cm in width and setting in mortor complete set in mortor 1:6 pre cast cement concrete Type C1 1:3:6 (20mm graded stone aggregate) etc completed all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint over a coat of red oxide etc completed all as specified and directed
S & F Fe 410 W (Gde E 250) Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc completed all as specified and directed
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws etc completed all as specified and directed
S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws etc completed all as specified and directed
Dismantling asbestos cement corrugated, semicorrugated etc sheets in roof covering, cladding etc and stacking for issuing under Sch. of credit.including scaffolding and necessary safety arrangements etc completed all as specified and directed
Dismantling timber scantling in fillets, rails, posts, rafters, purlings etc under 40 Sqcm in section etc completed all as specified and directed
Dismantling wall and ceiling board and glass wool any thickness including snap grid complete at any height etc completed all as specified and directed
M & L for aluminium anodised suspended false ceiling in the panels of size 605 x 605 mm with aluminium anodised angle 30 x30 x 2 mm fixed along the wall and main and cross tees of size 31.75 x 31.75 x 1.6 mm screwed along side of walls fixed with wooden plugs and hanging from existing slab/ steel truss including 6 mm dia GI wire suspended adjustable level from rafter purlins(length as per site requirement) including 600 x600x 12 mm thick Gypsum boards ceiling of make - Everest/ Saint Gobain or equivalent including cutting and making suitable opening for light fittings and applying 2 coats of Oil bound destemper over a coat of primer with preparation of new surface etc completed all as specified and directed
M & L for brick work with subclass 'B' bricks straight or curved on plan exceeding 6mm mean radius built in CM 1:6 etc completed all as specified and directed
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water complete all as specified including necessary scaffolding and safety arrangement etc and removing debris outside MD land completed all as specified and directed
M & L for rendering 12mm thick using polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smoothetc completed all as specified and directed Make: easyplast from wall plast/readiplast from ultratech Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account. The rate also includes the rate of scaffolding and necessary safety measurements
M&L for 20mm (12+8mm)thick in two coats polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed Make: easyplast from wall plast/readiplast from ultratech Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account. The rate also includes the rate of scaffolding and necessary safety measurements
M&L preparation of new plastered surfaces on wall including necessary scafflding and applying two coats of acrylic exterior paint over a coat of acrylic primer (Ultima Apex manufactured by Asian paints or weather shield max from ICI ) etc completed all as specified and directed.
S & F solid PVC wall lining consisting of 5 mm thick wood grain printed PVC sheet inclusive of solvent cement, PVC fillet , GI framework for fixing etc completed all as specified and directed
M&L Preparation of new plastered surfaces of walls and applying one coat of primer, 3mm wall care putty as a levelling course to obtain plain surface and applying two coat of oil bound distemper etc completed all as specified and directed
Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc and removing the debris out side MD land complete all as specified and directed .
M&L screed bed or bedding layer 15mm thick for laying floor finishes in cement mortar 1:6 to recive tiles etc completed all as specified and directed
M & L Non Skid ceramic coloured tiles 8 to10 mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles etc completed all as specified and directed
M&L for Non skid coloured ceramic tiles 7mm to 8mm thick ( square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles etc completed all as specified and directed
M&L for rendering 10mm thick in cement and sand mortar 1:4 finished even & rough for fixing of tiles as in dado or fixing skirting etc completed all as specified and directed
M&L for coloured glazed ceramic tiles in vertical surface 300x450x6 to 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles etc completed all as specified and directed
S & F 12 mm thick entrance door madeup of Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required with all fitting and fixture complete, including floor spring, fancy handle, necessary aluminium framework including suitable beading and with necessary electrical fittings etc complete all as specified and directed
M & L 20mm thick Granite (of any type) tiles machine cut, in Jambs, skirting/ dado laid over 15mm thick cement screed in CM (1:4) and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing etc completed all as specified and directed
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc completed all as specified and directed
Taking down wooden chowkats or frames with shutters (without taking off shutters from the frame)exceeding 1.5 sqm each. and stacking for issued under Sch of Credit etc completed all as specified and directed
S&F 2nd class hard wood plain, solid straight chowkats and frame, wrought framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints including good the disturbed surfaces of walls complete all as specified etc completed all as specified and directed
S&F 2nd class hard wood 35mm thick, plain, framed panelled shutters (any number of panels), with panels of timber flat on both sides (Feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers, fitted to chowkats etc completed all as specified and directed
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges:large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 etc completed all as specified and directed
M& L for treating small articles such as stop, covers, gully gratings, hold fasts, and of posts , back of chowkats, etc area not exec 0.1 Sqm each treated with tar or coal tar black paint etc completed all as specified and directed
S&F aluminium anodised sliding door bolts with hasp and staple (Bolt type) and fixing clip of lsheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, length of bolt 300mm etc completed all as specified and directed
S & F stainless steel butt hinges with extruded aluminium alloy with galvanised mile steel hinges pins 100mm size etc completed all as specified and directed
S & F 150 mm extruded aluminium alloy handles, fabricated type anodised etc completed all as specified and directed
S & F aluminium anodised barrel tower bolt of extruded section of size 200 mm length etc completed all as specified and directed
S&F in repairs vitreous coloured China Europeon water closet (Pedestal Pattern) including 10 ltr capacity low level flushing cistern with necessary conneictions etc completed all as specified and directed
S&F in repairs vitreous China wash basin white, flat back size 550 x 400mm including 15mm dia fancy type pillar tap, chromium plated CP waste coupling, chain and plug, waste fitting, union and waste pipe 32mm dia of required length and all necessary 450mm long outlet and inlet PVC connections pipes with PTMT check nuts etc completed all as specified and directed
S&F fixex in repairs vitreous china urinal bowl type (back or corner wall type ) of size 465 x 355 x 265mm complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement with discharge pipe etc completed all as specified and directed
M&L for 22mm thick Ecoflex Tuff floor / Equivaltent with Coloured Rubberised Flooring in Chequered pattern size 500x500mm thick fixed with adhesive complete as per manufacturers instruction and to fixed through manufacturers applicator itself etc completed all as specified and directed Note :- Certificate from the for manufacturer for application and durability to be provided on completion of job
M&L for Filleting exc 25 but n exc 50 Sqcm in any position and to any shape in Cement mortar 1:3 including all mitres, stops etc completed all as specified and directed
S&F standard aluminium section anodised shutters for doors, window / ventilators, partitions, fixed / openable / sliding or in any pattern, cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass, provision of hinges, screws, plugs, handle, lock, roller, Nylon ball bearing etc complete all as specified and directed (Aluminium section shall be of make Jindal/Hindalco/ Indalco) Note:- Weight of Aluminium sections as per actual or as per IS or as per manufacturer, whichever is less, shall only be considered for payment. Cost of other items / accessories required for entire completion of the work shall be deemed to be included in the quoted rate. However glass panes and wire cloth shall be measured and paid separately as supply only under respective items.
S&F 12mm thick prelaminated particle board exterior grade, prelaminated both sides with decorative choice lamination etc complete all as specified and directed
Supply and fixing 4 mm thick plain sheet glass, ordinary quality with and including provision of new rubber gasket after hacking out old broken glass (any size, quality or description) for existing aluminium joinery etc completed all as specified and directed
S&F framed work as in doors or gates of angle or other section with gussed plates rails braces etc, conforming to Fe-290 (Grade-E-165) complete drilled for fixing of steel sheeting or other coveringc, all as specified and directed.
M& L preparing new surfaces and applying three coats of white wash ceiling etc completed all as specified and directed
M&L Vitrified Ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match ,light shade etc completed all as specified and directed.
S/F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed etc completed all as specified and directed
S & F mild steel 4 lever Mortice lock, vertical type size 100mm etc completed all as specified and directed
Taking down carefully old unserviceable copper / aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings and making good disturbed suface of wall, floors, ceiling etc completed all as specified and directed
M & L for Point wiring complete with proper colour coding using, 1100 Volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked drawn in and including PVC casing caping (minimum 25mm dia) with all accessories, fittings, PVC junction boxes etc, also including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for one light point /fan/bell point controlled by one one way switch
All as per item No 67.00 above but for One 5A 2pin/3pin switch socket out let multipurpose on the same board with other switches etc complete all as specified and directed.
All as per item No 67.00 above but for One 5 Amps 2 pin / 3 pin switch socket outlet multipurpose on Independent Board etc complete all as specified and directed.
All as per item No. 67.00 above but wiring complete with 2.5 Sqmm for 3 pin 15A switch socket multipurpose on independent board etc complete all as specified and directed.
S&F modular type 6A one way SP switch 1 module confirming to IS: 3854-1997 with fingure proof terminal etc complete all as specified and directed.
S&F modular type 2/3 pin combined shuttered type 6 Amps socket 2 module conforming to IS: 1293-2005 etc complete all as specified and directed.
S&F modular type 2/3 pin combined shuttered typr 16 Amps socket 2 module conforming to IS: 1293-2005 etc complete all as specified and directed.
S&F modular type 16 A one way SP switch 1 module confirming to IS: 3854-1997 with finger proof terminal etc complete all as specified and directed.
S&F modular type 120W step fan regulator of 2 module size conformng to IS: 11037-1984 etc complete all as specified and directed.
S & F Modular Blank plate 1 module suitable for Modular switch boards etc complete all as specified and directed.
S & F Modular metal flush box modular cover plate 8 modules etc complete all as specified and directed.
S & F Modular metal flush box with modular cover plate 6 modules etc complete all as specified and directed.
S & F Modular metal flush box with modular cover plate 4 modules etc complete all as specified and directed.
S & F Modular metal flush box with modular cover plate 3 modules etc complete all as specified and directed.
S & F Modular metal flush box with modular cover plate 2 modules etc complete all as specified and directed.
S & F Modular metal flush box with modular cover plate 1 module etc complete all as specified and directed.
S&F ceiling rose three terminal, 230 Volts PVC / Polycarbonate body, complete all as specified and directed.
S&F sheet metal enclosure, 32A single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 32 Amp fixed properly on in concealed position etc complete all as specified and directed.
S & F MCB DB 6 way TPN, double door, vertical type, IP - 53 with 200 Amps rated bus bar, AC and connecting up including takingdown old MCB DB etc complete all as specified and directed.
Supply and fix MCCB 4 Pole, 125 Amps 415 Volt 35 KA with and including CRCA powder coated enclosure ('F' frame) with front openable door, wall mounted type with provision for cable entry suitable for upto 70 sqmm x 3.5 Core cable including necessary grouting in wall with nuts, bolts/ fastener, washer etc complete all as specified and directed.
S & F MCB SP 5 to 32 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity etc complete all as specified and directed.
S & F MCB, SPN, 06 to 32 Amps, 240 Volts, 10 KA Breaking capacity, C-series, complete all as specified and directed.
S&F in repairs Surface, hanging and wall mounted batten (Double side connection) suitable for LED tube 20/22 watts, 230 volts alongwith tube rod 20 watt (double side connection), including fixing mounting blocks 2 Nos, 15 mm MS conduit, 1.5 sqmm 3 core pvc insulated copper conductor cable including fixing arrangements etc complete all as specified and directed.
Supply and fix decorative recessed type LED light fitting 35 watt (size 2'x2') and including driver unit, including provision of 3 core copper flexible cable 1.5 Sqmm from ceiling rose to connector, including making addition/altn to existing false ceiling and providing of false ceiling sheets, aluminium frames including fixing arrangements complete etc complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty with stranded aluminium conductor 1100 volts grade of 4 core 25 sqmm including saddling in wall, cable duct with lugs & spacers connecting to LT panels etc complete all as specified and directed.
Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection etc complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches etc complete all as specified and directed.
M & L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers all as shown in Electrical Plate No.3 connected to earthing test point all as specified or indicated including testing on completion etc complete all as specified and directed.
Taking down of existing ceiling fans and re-fixing of the same ceiling fan 1200mm sweep including provision of cable from ceiling rose/ conductor to fan and spray painting of ceiling fan with two coats of synthetic enamel paint, after preparation of surfaces etc complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers etc complete all as specified and directed.
M & L for Cutting holes into or through brick walls built in cement mortar for fixing the fan and making good the distrubed surfaces in cement mortar 1:3 or cement concrete 1:2:4 type B1 etc complete all as specified and directed.
M & L for taking down of split type AC of capacity 1.5 TR to 2.5 TR including indoor & out door unit, servicingthe complete unit and refixing the same at directed place after carrying out repairs works, including provision of wall brackets for indoor unit made of flat iron of size 32 X 6 mm with fasteners and testing etc complete all as specified and directed. Note - Pipe line if any required will measured and paid seperately.
S & F 20 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture etc complete all as specified and directed
S & F 36 W ceiling recessed light of size (2x2 ft) having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture etc complete all as specified and directed
Supply and fixing wall mounting fan 400 mm sweep along with blade, canopy, mounting brackets, rubber insulator, etc complete all as specified and directed
S & F MCB DB, 8 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections, etc complete all as specified and directed Note: Quoted rate shall also be deemed to include for provision of copper bus bar of 200 Amps rating.
S&F MCCB DB, TPN, double door, 4 way IP 43 metal body having earth terminal, neutral bus terminal for 4 way circuits complete in all respect fixed on wall including making electrical incoming and out going connections with lugs/thimbles cetc complete all as specified and directed
S & F of MCCB 100Amps, 4 pole, 16KA, 415 volts including connecting up etc complete all as specified and directed
S & F MCB, TPN, 40 Amps, 415 Volts, 10 KA Breaking capacity, C-series, etc complete all as specified and directed
Supply and fix earthed metal clad socket outlet with earthed plug top 20 Amp capacity, sheet metal enclosed and one 20 Amp MCB SP etc complete all as specified and directed.
M & L for submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor (2 X 4.0 mm² + 1 X 4.0 mm² earth wire) connecting to earth dolly, drawn in not less than 25 mm NB UPVC medium grade surface/recessed conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor, etc complete all as specified and directed Note : 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of casing caping shall be measured as one length.
All as per Item No 108.00 above but 2 X 6.0 mm² + 1 X 6.0 mm² earth wire etc complete all as specified and directed Note - A sum of Rs 28,656.50 towards sch of credit shall be deducated to arrive the contract sum.
Atharva Enterprises
sahajanand const co.
H R ENGINEERS
Joy builders
A R ENGINEER
SRINIVASA BUILDERS
GAJANAN SALES CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .