Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical 16 INDUSTRIAL ESTATE NUNHAI AGRA AGRA UTTAR PRADESH 282006 | AGRA | UTTAR PRADESH | 282006 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical 218 BAKROL BUJARANG OPP N K INDUSTRIAL PARK DHAMATVAN ROAD BAKROL AHMEDABAD GUJARAT 382210 | AHMADABAD | GUJARAT | 382210 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical RAJKOT GUJARAT 360311 | RAJKOT | GUJARAT | 360311 | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical 45 TRIBHUVAN ESTATE NR KATHWADA GIDC KATHWADA TA DASCROI AHMEDABAD GUJARAT 382430 | AHMADABAD | GUJARAT | 382430 | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical 401 A POONAM CHAMBERS 115 DR ANNIE BESANT ROAD WORLI MUMBAI MAHARASHTRA 400018 | MUMBAI | MAHARASHTRA | 400018 | Admitted-Fee/PreQual/Technical |
Tender Value
Refer Docs
Closing Date
26 Aug 2026, 2:30 pmClosed
Krishan Pal Singh
Technip Energies India Ltd. A4, Sector-1 Neida Uttar Pradesh 201301
Manufacturing, procurement of materials and bought out components, assembly at shop, Inspection including inspection by TPIA, Testing at manufacturer works, packing, SUPPLY OF CAST GGC VALVES (MTO-4) details as per material requisition
2026_REFHQ_190941_1
TP/214227C/DR/1310-0302/1120
Limited
Mechanical - Piping, materials, flanges, valves, seals
Supply
105 days
IOCL DIGBOI REFINERY
Refer tender details
6 documents required · 6 mandatory
Exempted
27 Aug 2026
12 Aug 2026
27 Aug 2026
12 Aug 2026
26 Aug 2026
18 Aug 2026
12 Aug 2026 - 17 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | HSN/SAC |
|---|---|---|---|---|---|---|
| 1 | 2 IN Swing Check Valve Flanged Ends, -, BS 1868, ASTM A216 Gr.WCB, 150 Lbs, Installation: Horizontal or Vertical, FF, Ends as per ASME B16.5, -, Bolted Cover, A193 Gr.B7/A194 Gr.2H, -, SPW AISI 316/Graphite, -, Renewable Seats, Seats: -, Bronze, -, -, -, -, -, -, | 2 | EA | - | - | 0.18 |
| 2 | 2 IN Swing Check Valve Flanged Ends, -, BS 1868, ASTM A216 Gr.WCB, 150 Lbs, Installation: Horizontal or Vertical, RF, Ends as per ASME B16.5, -, Bolted Cover, A193 Gr.B7/A194 Gr.2H, -, SPW AISI 316/Graphite, -, Renewable Seats, Seats: -, BS Trim CR13-HF, -, -, -, -, -, -, | 5 | EA | - | - | 0.18 |
| 3 | 10 IN Swing Check Valve Flanged Ends, -, BS 1868, ASTM A216 Gr.WCB, 150 Lbs, Installation: Horizontal or Vertical, RF, Ends as per ASME B16.5, -, Bolted Cover, A193 Gr.B7/A194 Gr.2H, -, SPW AISI 316/Graphite, -, Renewable Seats, Seats: -, BS Trim CR13-HF, -, -, -, -, -, -, | 1 | EA | - | - | 0.18 |
| 4 | 2 IN Swing Check Valve Flanged Ends, -, BS 1868, ASTM A216 Gr.WCB, 150 Lbs, Installation: Horizontal or Vertical, RF, Ends as per ASME B16.5, -, Bolted Cover, A193 Gr.B7/A194 Gr.2H, -, SPW AISI 316/Graphite, -, Renewable Seats, Seats: -, BS Trim CR13-HF, -, -, -, -, -, Fugitive emission as per ISO 15848 Part-1: Tightness class C | 5 | EA | - | - | 0.18 |
| 5 | 4 IN Swing Check Valve Flanged Ends, -, BS 1868, ASTM A216 Gr.WCB, 150 Lbs, Installation: Horizontal or Vertical, RF, Ends as per ASME B16.5, -, Bolted Cover, A193 Gr.B7/A194 Gr.2H, -, SPW AISI 316/Graphite, -, Renewable Seats, Seats: -, BS Trim CR13-HF, -, -, -, -, -, Fugitive emission as per ISO 15848 Part-1: Tightness class C | 2 | EA | - | - | 0.18 |
| 6 | 6 IN Swing Check Valve Flanged Ends, -, BS 1868, ASTM A216 Gr.WCB, 150 Lbs, Installation: Horizontal or Vertical, RF, Ends as per ASME B16.5, -, Bolted Cover, A193 Gr.B7/A194 Gr.2H, -, SPW AISI 316/Graphite, -, Renewable Seats, Seats: -, BS Trim CR13-HF, -, -, -, -, -, Fugitive emission as per ISO 15848 Part-1: Tightness class C | 1 | EA | - | - | 0.18 |
| 7 | 2 IN Swing Check Valve Flanged Ends, -, BS 1868, ASTM A216 Gr.WCB, 300 Lbs, Installation: Horizontal or Vertical, RF, Ends as per ASME B16.5, -, Bolted Cover, A193 Gr.B7/A194 Gr.2H, -, SPW AISI 316/Graphite, -, Renewable Seats, Seats: -, BS Trim CR13-HF, -, -, -, -, -, Fugitive emission as per ISO 15848 Part-1: Tightness class C | 5 | EA | - | - | 0.18 |
| 8 | 3 IN Swing Check Valve Flanged Ends, -, BS 1868, ASTM A216 Gr.WCB, 300 Lbs, Installation: Horizontal or Vertical, RF, Ends as per ASME B16.5, -, Bolted Cover, A193 Gr.B7/A194 Gr.2H, -, SPW AISI 316/Graphite, -, Renewable Seats, Seats: -, BS Trim CR13-HF, -, -, -, -, -, Fugitive emission as per ISO 15848 Part-1: Tightness class C | 1 | EA | - | - | 0.18 |
| 9 | 4 IN Swing Check Valve Flanged Ends, -, BS 1868, ASTM A216 Gr.WCB, 300 Lbs, Installation: Horizontal or Vertical, RF, Ends as per ASME B16.5, -, Bolted Cover, A193 Gr.B7/A194 Gr.2H, -, SPW AISI 316/Graphite, -, Renewable Seats, Seats: -, BS Trim CR13-HF, -, -, -, -, -, Fugitive emission as per ISO 15848 Part-1: Tightness class C | 2 | EA | - | - | 0.18 |
| 10 | 6 IN Swing Check Valve Flanged Ends, -, BS 1868, ASTM A216 Gr.WCB, 300 Lbs, Installation: Horizontal or Vertical, RF, Ends as per ASME B16.5, -, Bolted Cover, A193 Gr.B7/A194 Gr.2H, -, SPW AISI 316/Graphite, -, Renewable Seats, Seats: -, BS Trim CR13-HF, -, -, -, -, -, Fugitive emission as per ISO 15848 Part-1: Tightness class C | 6 | EA | - | - | 0.18 |
stage.html
html • 0.04 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.26 MB
Tender-Acceptance-Format.pdf
Additional Documents • 0.08 MB
FAQs-IOCL-Online-EMD.pdf
Additional Documents • 0.55 MB
Bidders_help_Document_for_Preferencial_Bidding_20230207_v1.pdf
Additional Documents • 0.82 MB
Special_Instructions_to_the_Bidders_Version_5_dated_30_June_2025.pdf
Additional Documents • 2.80 MB
BOQ_201223.xls
BOQ • 0.58 MB
Commercial_ITB.pdf
Tender Documents • 10.53 MB
Technical_MR.pdf
Tender Documents • 8.67 MB
Bid_Documents_1120.xls
Tender Documents • 31.32 MB
GPC_Updated_With_ISB.PDF
Tender Documents • 2.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .