Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹63.6 L
EMD Value
₹1.3 L
Closing Date
29 Nov 2022, 6:00 pmClosed
Executive Engineer
PWD Electrical Division I Jaipur
Strengthening of Existing 11 KV HT Supply Distribution and Switchgear Protection System at HCM RIPA campus, Jaipur
2022_CEPWD_306312_1
NIT NO 25 of 2022-23 EE PWD E-I Jaipur
Open Tender
Electrical Works
Percentage
180 days
HCM RIPA Campus Jaipur
Please refer tender documents
3 documents required · 3 mandatory
₹1,000
Through Egras Challan in Office ID 4222
₹1.3 L
Yes
In the Chamber of Executive Engineer
2 Dec 2022
21 Nov 2022
30 Nov 2022
21 Nov 2022
29 Nov 2022
21 Nov 2022
25 Nov 2022
Amount
Supply of 11 kV 630 Amps 21KA for 3 Sec. SF6 insulated, Both side extensible, outdoor duty (IP54) Extensible/ Non Extensible type Ring main unit manually operated in combination of VCB module and load break switch consisting of copper busbar in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271- 200-2003 and IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1 Second with IAC-AFL classification for gas tank. Vacuum Interrupter of VCB should be RMU Manufacturer’s own make. Feeder of should have voltage presence indicator. All the type test certificated as per IEC from Third party lab to be submitted. RMU Should have followings: - 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault and short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 75/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB. - 1 No. Manometer for each tank -1 Nos fauls passage indicatos,Right angle boots for all the feeder Modules. All The type test certificate as per IEC from third party NABL/CPRI/ERDA accrediated lab to be submitted.( Cost of RCC Foundation/steel structure to be paid extra) all as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .Extensible 1 way RMU with 1 No. VCB and direct cable entry
M/S VDK ENTERPRISES
Choudhary Enterprises
Shanti Enterprises
Choudhary Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .