| 1 | L1₹23.3 LAccepted-AOC 6 1ST CROSS 1ST MAIN OLD POLICE STATION ROAD LAKKASANDRA BANGALORE 560 030 | BENGALURU URBAN | KARNATAKA | 560030 | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹27.0 L+₹3.5 L (14.8%)Rejected-AOC NO 6 G 2 SS ENCLAVE 1ST MAIN 1ST CROSS INDIAN EXPRESS LAYOUT VIRUPAKSHAPURA VIDYARANYAPURA POST BANGALORE 560 097 | BENGALURU URBAN | KARNATAKA | 560097 | L2 | Rejected-AOC High bid value | |
| 3 | Rejected-Technical | - | Rejected-Technical Not recommended since the contractor withdrawn his offer vide letter No Nil dated 04 Aug 2023@F/10 |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
2 Aug 2023, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE 560006
PERIODICAL SERVICES TO OTM, MD ACCN AND CLEANING OF RCC/PVC SERVICE TANKS, RAIN WATER PIPE, WATER PIPE LINE AND CONNECTED WORKS AT CHAF BANGALORE
2023_MES_606436_1
8121/GE/42
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
GE (AF) BANGALORE
₹76,000
8 Sept 2023
28 Jun 2023
8 Aug 2023
28 Jun 2023
2 Aug 2023
13 Jul 2023
30 Jun 2023 - 5 Jul 2023
Amount
M&L for cleaning and degermination inside of RCC/PVC water storage tanks capacity not exceeding 500 Ltrs of any description and any position compring following seven stage cleaning and sterilization of water tanks through bacteriological treatment by using TERBAC G5/lnchlor-5/NB-10, Terbac G65/lnoxi-60/NB69 and ultra violet rays complete all as directed. (a) First stage is to drain out the water by using exit valve or our own high capacity dewatering systems or any other suitable method approved by Engr -in- Charge (b) Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/lnchlor-5/NB-10 a laboratory tested branded chemical of the company and scrubbing the walls of the tanks (c ) Third stage is fresh water cleaning by high speed jet pump with pressure 5 PSL (d) Fourth stage first bicteria screening and sterilization by using Terbac G5.NB-10 a Laboratory certified branded halogen compound , test certificate of TERBAC G5/lnchlor-5/NB -10, from government laboratory mentioning suitable for sterilization (e) Fifth stage is cleaning the floors of the water tanks by heavy duty industrial vaccume cleaner (f) Sixth stage is second bacteria screening and sterilizating method by using ultra violet rays ejector covering 360 degree with in th etank and kill all suspended bacteria (g) Seventh stage of cleaning and third bacteria screening is to be steriliz the floor of the water tank by using laboratory certified branded strong oxidizing agend TERBAC G 65/lnoxi-60/NB-69 Note:- (i) Test certificate of TERBAC G65/lnoxi-60/NB-69 from Government laboratory mentioning suitability for sterilization should be submitted to the office before using for sterilization (ii) Outlet pipe of OHT should be plugged before cleaning the OHT to aviod entering scale and the same shall be re-connected after ceaning the OHT and the quoted rate is deemed to include for this provision (iii) Contractor will be responsible for rectification of complaints occurred during cleaning of the tank. i.e. No water in tank/over flow due to broken of float valve /blokage of of outlet lines due to silt and rectification cost will be deemed to be included in quoted rate Note : The work shall be carried through specilized agency Rays Cleantech (Mob-727879029) or other agency as approved by GE.
All as per Item No. 01 here in above but capacity of tank exceeding 500 Ltrs and not exceeding 1000 Ltrs.
All as per Item No. 01 here in above but capacity of tank exceeding 1000 Ltrs and not exceeding 2000 Ltrs.
All as per Item No. 01 here in above but capacity of tank exceeding 2000 Ltrs and not exceeding 5000 Ltrs.
All as per Item No. 01 here in above but capacity of tank exceeding 5000 Ltrs and not exceeding 10000 Ltrs.
Taking up or down steel tubing and connections, fittings etc including cleaning for refixing or removal to store for 15mm bore complete all as specified and as directed. Note :- Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work.
Taking up or down steel tubing and connections, fittings etc including cleaning for refixing or removal to store for 20mm bore complete all as specified and as directed. Note :- Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work.
Taking up or down steel tubing and connections, fittings etc including cleaning for refixing or removal to store for 25mm bore complete all as specified and as directed. Note :- Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work.
Supply and fixing tube medium grade galvanized with all fittings 15mm bore and connections, complete all as specified and as directed.
Supply and fixing tube medium grade galvanized with all fittings 20mm bore and connections, complete all as specified and as directed.
Supply and fixing tube medium grade galvanized with all fittings 25mm bore and connections, complete all as specified and as directed.
Taking up or down steel tubing and connections, fittings etc including cleaning for refixing and Refixing old steel tubing and connections,fittings etc in new or old position (Walls, ceiling, floors, etc.) 15 mm bore complete all as specified and as directed.
Taking up or down steel tubing and connections, fittings etc including cleaning for refixing and Refixing old steel tubing and connections, fittings etc in new or old position (Walls, ceiling, floors, etc.) 20 mm bore complete all as specified and as directed.
Taking up or down steel tubing and connections, fittihgs etc including cleaning for refixing and Refixing old steel tubing and connections, fittings etc in new or old position (Walls, ceiling, floors, etc.) 25 mm bore complete all as specified and as directed.
S&F in repairs 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
S&F in repairs 25mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
S&F in repairs ball brass valves, 20mm dia bore high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule all as specified and directed.
S&F in repairs ball brass valves, 25mm dia bore high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule all as specified and directed.
S&F trible layered Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I , 500 Ltrs Capacity including dismantling existing 500 Ltr water tanks complete all as specified and as directed.
S&F trible layered Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I , 1000 Ltrs Capacity including dismantling existing 1000 Ltr water tanks complete all as specified and as directed.
S&F trible layered Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I , 2000 Ltrs Capacity including dismantling existing 2000 Ltr water tanks complete all as specified and as directed.
Disconnecting existing tanks, setting aside or lowering if required for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in old or new location position capacity exc 250&n exc 500 Ltrs complete all as specified
Disconnecting existing tanks, setting aside or lowering if required for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in old or new location position capacity exc 500 & n exc 1000 Ltrs complete all as specified
Disconnecting existing tanks, setting aside or lowering if required for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in old or new location position capacity exc 1000 & n exc 2000 Ltrs complete all as specified
S & F repairs PVC lid any colour to match the existing PVC water storage tanks capacity up to 500 Ltrs.
S & F repairs PVC lid any colour to match the existing PVC water storage tanks capacity 500 Ltrs to 1000 Ltrs.
S & F repairs PVC lid any colour to match the existing PVC water storage tanks capacity 1000 Ltrs to 2000 Ltrs.
S & F in repairs 20 mm GI nipple threaded 100 mm long.
S & F in repairs 25 mm GI nipple threaded 100 mm long.
S & F in repairs GI union threaded for 20 mm GI Pipe.
S & F in repairs GI union threaded for 25 mm GI Pipe.
S & F in repairs GI reducer 25/20mm threaded GI Pipe.
S & F in repairs 20 mm GI tank nipple threaded .
S & F in repairs 25 mm GI tank nipple threaded .
M&L preparation of plastered or un plastered old decorated surfaces of walls by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying one coat of cement base paint, through mechanical means including necessary scaffolding upto 6th storey complete all as specified and as directed.
M&L preparation of plastered or un plastered old decorated surfaces of walls by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying two coat of cement base paint, through mechanical means including necessary scaffolding upto 6th storey complete all as specified and as directed.
M&L preparation of plastered or un plastered old decorated surfaces of walls by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying applying one coat of exterior emulsion paint (weather coat) through mechanical means including necessary scaffolding upto 6th storey complete all as specified and as directed.
M&L preparation of plastered or un plastered old decorated surfaces of walls by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying applying two coat of exterior emulsion paint (weather coat) through mechanical means including necessary scaffolding upto 6th storey complete all as specified and as directed.
M&L for complete removal of existing treatment on walls and preparation of plastered or un plastered old decorated surfaces of walls by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying applying two coat of exterior emulsion paint (weather coat) over a coat of primer through mechanical means including necessary scaffolding upto 6th storey complete all as specified and as directed.
M&L preparation of plastered or un plastered old decorated surfaces of walls by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying one coat distemper oil emulsion, through mechanical means white or tinted including necessary scaffolding up to 6th storey complete all as specified and as directed.
M & L preparation of plastered or un plastered old decorated surfaces of walls by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying two coat of oil bound distemper through mechanical means including necessary scaffolding upto 6th storey all as specified and as directed.
M&L complete removal of existing treatment on walls and applying 3mm thick wall care putty(birla putty) and preparation of surface making smooth and applying primer of chalk whiteneing as base coat and applying two coat of oil bound distemper through mechanical means including necessary scaffolding up to 6th storey complete all as specified and as directed
M & L preparation of plastered or un plastered old decorated surfaces of ceiling cornices etc. by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying one coat of oil bound distemper through including necessary scaffolding upto 6th storey all as specified and as directed.
M & L preparation of plastered or un plastered old decorated surfaces of ceiling, cornices etc. by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying two coats of oil bound distemper through mechanical means including necessary scaffolding upto 6th storey all as specified and as directed.
M&L preparation of plastered or un plastered old decorated surfaces of walls by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying one coat of white wash including necessary scaffolding upto 6th storey complete all as specified and as directed.
M&L preparation of plastered or un plastered old decorated surfaces of walls by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying two coat of white wash including necessary scaffolding upto 6th storey complete all as specified and as directed.
M&L preparation of plastered or un plastered old decorated surfaces of ceiling by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying one coat of white wash including necessary scaffolding upto 6th storey complete all as specified and as directed.
M&L preparation of plastered or un plastered old decorated surfaces of ceiling by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying two coat of white wash including necessary scaffolding upto 6th storey complete all as specified and as directed.
M&L preparation of plastered or un plastered old decorated surfaces of walls by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying applying one coat of platic emulsion paint through mechanical means including necessary scaffolding up to 6th storey complete all as specified and as directed.
M&L preparing of old painted surfaces of wood & wood based surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint including necessary scaffolding up to 6th storey complete all as specified and as directed.
M&L preparation of old painted surfaces of steel surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint including necessary scaffolding up to 6th storey complete all as specified and as directed.
M&L for preparation of old painted concrete surface/plaster surfaces/stone surfaces/brick and applying one coat of synthetic enamel paint etc complete all as specified and as directed.
Taking down cement plaster on brick or concrete or stone walls including racking out joints, hacking for key, scrubbing down with water etc including necessary scaffolding up to 6th storey complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement including necessary scaffolding up to 6th storey complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished fair and even etc including necessary scaffolding up to 6th storey complete all as specified and as directed.
M&L rendering 10 mm thick in cement mortar 1:3 on ceiling of brick or concrete surfaces, finished even and smooth without using extra cement including necessary scaffolding up to 6th storey complete all as specified and as directed.
M&L for Preparing new plastered suface of walls and applying two coats distemper oil emulsion through mechanical means white or tinted over a coat of primer including necessary scaffolding up to 6th storey complete all as specified and as directed.
M&L for Preparing new plastered suface of ceilings and applying two coats distemper oil emulsion, through mechanical means white or tinted over a coat of primer including necessary scaffolding up to 6th storey complete all as specified and as directed.
M&L for preparing new plastered surface of walls and applying two coat of exterior emulsion paint (weather coat) over a coat of primer through mechanical means including necessary scaffolding up to 6th storey complete all as specified and as directed
M&L for preparing new plastered surface of walls and applying two coats of cement base paint over a coat of primer through mechanical means including necessary scaffolding up to 6th storey complete all as specified and as directed
M&L for preparing new plastered surface of walls and applying three coats of white wash including necessary scaffolding up to 6th storey complete all as specified and as directed.
M&L for preparing new plastered surface of ceiling and applying three coats of white wash including necessary scaffolding up to 6th storey complete all as specified and as directed.
Removing of vegetation/plants growth/weeds etc including acid treatement for roots and necessary plastering in patches not exc 1.00sqm to the existing wall in terraces, wall surface of building etc including necessary scaffolding up to 6th storey complete at all floor levels complete all as specified and directed.
M & L for obliterating old writing of any description, n exc 0.1 sq. m, with paint to match existing work complete all as specified and directed.
M&L for writing letters or figures ((block, roman, italic or indian) n.exc 30cm high complete all as specified and directed.
VIKAS CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .