Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹54.9 L
EMD Value
₹1.1 L
Closing Date
4 Nov 2026, 3:30 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
Above/Below/Par
CONS
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB(GCC) of tender document, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: •Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or •Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or •One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Supply, Installation, Testing and Commissioning of industrial electrical installation work involving voltages of 415 volts or greater
24 conditions · 10 needing a document upload
The tenderer should submit the consent in a mandate form of Enclosure-1 for receipt of payment through NEFT
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Certificates which may be an attested Certificate from the client, Audited Balance Sheet duly certified by the Chartered Accountant etc regarding contractual payments received in the past
Tenderer shall indicate their GSTIN No. & PAN No. with proper document proof.
If the tenderer wish to submit Bank guarantee for bid security (EMD), the Tenderer shall download the Tender Document Annexure -VI A for bid security in the form of bank guarantee and upload the Annexure -VI A duly filling the necessary details. The original Bank Guarantee should be delivered in person to Office of the PCEE, II floor, Shell Administrative building, ICF, Chennai - 600 038 before closing date for submission of bids (i.e. excluding the last date of submission of bids)
Startups are not exempted from satisfying the Eligibility criteria for this tender.
The Tenderer shall have valid required level Electrical License. Attested copy of the Electrical License shall be submitted along with the offer.
The successful tenderer shall prepare and submit the Scheme for wiring along with layout of arrangement of Electrical switchgear drawings according to the site and obtain approval from the competent authority or their authorized representative prior to the commencement of work.
After completion of all wiring and installation, the successful tenderer shall submit 3 sets of General arrangement and Schematic drawings along with the electrical wiring documentation.
The rate quoted shall be net inclusive of all taxes (GST) and duties.
The Contractor has to engage only Police verified Pvt. labour /Pvt. Employee. If any new person (other than already verified) to be engaged by the contractor, he has to submit proof of Police verification application for issuing a "Temporary permission" like present permit system. However, Contractor has to arrange PV report within permissible period of one month.
The tenderer shall download the Tender Document Annexure -I and upload the Annexure -I duly filling the necessary details.
Electrification of construction of 2000 Sq.m shed with 15-meter clear height with 300 nos. pallets, in Furnishing Division.
2026245212361~ICF
2026245212361
Open
Works - General
6 Months
Chennai, Tamil Nadu
₹0
₹1.1 L
12 Oct 2026
12 Oct 2026
21 Oct 2026
104 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 50,55,333 | ||
| — | 500.00 | — | — | ||
| Supply of 300 Sq.mm, 3.5 core, XLPE LT, AL, Armoured, UG Cable as per ICF Specification. | — | — | — | 6,97,000 | |
| — | 500.00 | — | — | ||
| Supply of 185 Sq.mm, 3 1/2 core, XLPE LT, AL, Armoured, UG Cable as per ICF Specification. | — | — | — | 5,24,000 | |
| — | 500.00 | — | — | ||
| Supply of 35 Sq.mm, 4 core, XLPE LT, AL, Armoured, UG Cable as per ICF Specification. | — | — | — | 1,19,000 | |
| — | 500.00 | — | — | ||
| Laying of LT cable upto 300 sq.mm, duly excavating and re-filling the trench with excavated earth as per ICF Specification. | — | — | — | 70,500 | |
| — | 1000.00 | — | — | ||
| Laying of LT XLPE Aluminum and Copper cables up to 300sq.mm, in cable trays/trenches as per ICF Specification. | — | — | — | 35,000 | |
| — | 20.00 | — | — | ||
| Breaking & Redoing of concrete portion using contractors' own materials as per ICF Specification. | — | — | — | 76,980 | |
| — | 20.00 | — | — | ||
| Supply & Erection of End termination of UG Al cable 3.5/4 core, up to 50 sq.mm with all required items like proper glands and crimping sockets, hardware, crimping paste etc., as per ICF Specification. | — | — | — | 7,400 | |
| — | 20.00 | — | — | ||
| Supply & Erection of End termination of UG Al cable 3.5/4 core, 70/120/185 sq.mm with all required items like proper glands and crimping sockets, hardware, crimping paste etc., as per ICF Specification. | — | — | — | 11,940 | |
| — | 10.00 | — | — | ||
| Supply & Erection End termination of UG Al cable 3.5 core, 240/300 sq.mm with all required items like proper glands and crimping sockets, hardware, crimping paste etc., as per ICF Specification. | — | — | — | 7,680 | |
| — | 1.00 | — | — | ||
| Supply, installation & testing of 250A, TPN tap off box fitted with MCCB+ ROM+ Spreader links trunking suitable for plugging to 800A bus bar trunking system as per ICF Specification. | — | — | — | 30,232 | |
| — | 50.00 | — | — | ||
| Supply & laying of 4 core, 25 sq.mm armored copper cable as per ICF Specification. | — | — | — | 1,12,100 | |
| — | 1.00 | — | — | ||
| Supply of 4 pole, 250 Amps MCCB, 36 KA breaking capacity suitable for wall/ pillar mounting/ standalone type panel with top and bottom cable box and angle iron framework as per ICF Specification. | — | — | — | 24,329 | |
| — | 1.00 | — | — | ||
| Erection of MCCB panel up to 630 Amps suitable for wall/ pillar mounting/ standalone type panel with top and bottom cable box and angle iron framework as per ICF specification. | — | — | — | 1,084 | |
| — | 1.00 | — | — | ||
| Supply & Erection of 8 way SMDB with incomer as 400A TPN 36kA Thermal magnetic release MCCB-1 No and outgoing as 100A TP 25kA MCCBs - 8 Nos along with required metering box fitted with 3 no's 96 x 96 Digital Ammeter for individual phases and 1 no 96x96mm 3 phase Digital Volt meter and 1 No Selector switch and provision of left & right side cable end boxes & 4 no's corner filler boxes and base mounting assembly to be provided at bottom and RYB indication with required CTs and necessary wiring for Meters, Lamps, CTs, Complete set as per ICF Specification. | — | — | — | 1,96,267 | |
| — | 1.00 | — | — | ||
| Supply of Two bay lighting and ventilation control cubicle panel including all components like four knife switch isolators, contactors, timer etc., as per ICF drawing ICF/EL-1550 (3 Sheets) and as per ICF Specification. | — | — | — | 1,98,275 | |
| — | 1.00 | — | — | ||
| Installation, Testing and commissioning of lighting and ventilation panel with MS channel, grouting bolts and other masonry materials as per ICF Specification. | — | — | — | 7,057 | |
| — | 120.00 | — | — | ||
| Supply of Single Phase, Two Circuits (4 Live conductors) Lighting Bus way 40 Amps, Straight length with Tap-off provision along with blanking plate as per ICF Specification.( Quote for 1 mtr length) | — | — | — | 1,48,440 | |
| — | 10.00 | — | — | ||
| Supply of End Feed units with cover suitable for Lighting Bus Bay 40 amps (4 Conductors) as per ICF specification. | — | — | — | 21,660 | |
| — | 150.00 | — | — | ||
| Supply of 10 Amps Single phase Tap-off unit with fuse, L+N+E as per ICF Specification. | — | — | — | 52,950 | |
| — | 120.00 | — | — | ||
| Supply of GI Threaded Rod 12mm Dia along with required nuts, Bolts and washers suitable for fixing Medium Power Bus Bay Trunking system as per ICF specification. | — | — | — | 6,480 | |
| — | 120.00 | — | — | ||
| Erection (laying, Fixing, suspension), Testing and Commissioning of Lighting Bus way 40 Amps of Straight length with all accessories like, End feed unit, fixing bracket, Tap-off units, 12mm threaded rod and all other accessories as per ICF Specification. | — | — | — | 13,320 | |
| — | 40.00 | — | — | ||
| Supply of 150 W LED High Bay Industrial Luminaire Fitting with IP-66 (min) Protection powder coated die - cast aluminum housing with weatherproof gasket for lamp and control gear for Industrial application. (Scope Includes all Accessories as per ICF Specification). | — | — | — | 7,95,560 | |
| — | 40.00 | — | — | ||
| Fixing Testing and Commissioning of 150W LED High Bay Light Fitting in roof with supply and fabrication of suitable bracket in necessary fixing hardware as per ICF Specification. | — | — | — | 25,360 | |
| — | 20.00 | — | — | ||
| Supply of 45W LED Street light fitting with IP-66 protection as per ICF Specification. | — | — | — | 61,060 | |
| — | 20.00 | — | — | ||
| Fixing, Testing & Commissioning of 45W LED Street light fitting as per ICF Specification. | — | — | — | 3,800 | |
| — | 400.00 | — | — | ||
| Supply and laying of 3 core,1.5 sq.mm copper armored cable with MS clamping accessories etc., as per ICF Specification. | — | — | — | 55,600 | |
| — | 100.00 | — | — | ||
| — | 150.00 | — | — | ||
| — | 375.00 | — | — | ||
| — | 2.00 | — | — | ||
| — | — | — | 2,23,236 | ||
| — | 4.00 | — | — | ||
| — | — | — | 32,000 | ||
| — | 50.00 | — | — | ||
| — | — | — | 31,150 | ||
| — | 400.00 | — | — | ||
| — | — | — | 28,800 | ||
| — | 400.00 | — | — | ||
| — | — | — | 17,200 | ||
| — | 2.00 | — | — | ||
| — | — | — | 11,182 | ||
| — | 2.00 | — | — | ||
| Erection of Control panel for Air circulators and as per ICF Specification. | — | — | — | 452 | |
| — | 8.00 | — | — | ||
| Supply of BLDC Heavy Duty Wall mounting Air circulators of Sweep 24" (600mm) dia as per ICF Specification. | — | — | — | 1,40,600 | |
| — | 8.00 | — | — | ||
| Erection of 600 mm sweep Air circulator with proper framework and termination with 1.5 Sq.mm PVC flexible copper cable run from the control panel as per ICF Specification. | — | — | — | 3,864 | |
| — | — | — | 4,32,382 | ||
| — | 7.00 | — | — | ||
| Supply of IP 4 MP WDR Bullet Camera Certified by STQC as per ICF Specification. | — | — | — | 1,27,204 | |
| — | 1.00 | — | — | ||
| Supply of 27" LED monitor as per ICF Specification. | — | — | — | 19,297 | |
| — | 4.00 | — | — | ||
| Supply of 8 port POE Switch 100/1000 with SFP/ 2 GIG Uplink as per ICF Specification. | — | — | — | 33,688 | |
| — | 4.00 | — | — | ||
| Supply of 8 TB Enterprises Hard Disk for storage of CCTV footage as per ICF Specification. | — | — | — | 1,03,468 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
LISTOFWORKSONHAND.pdf
ATTACHMENT
LISTOFMachinery.pdf
ATTACHMENT
NEFTForm.pdf
ATTACHMENT
LISTOFCONTRACT.pdf
ATTACHMENT
LISTOFPERSONNEL_1.pdf
ATTACHMENT
TenderFormAnnexure-I.pdf
ATTACHMENT
IRGCCACSCombined_3.pdf
ATTACHMENT
annex6B.pdf
ATTACHMENT
IRGCC_April-2022.pdf
ATTACHMENT
943Tenderdocument.pdf
ATTACHMENT
Annexure-VIABidSecurity.pdf
ATTACHMENT
ACS12.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .