| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC | ₹2.0 Cr Quoted ₹2.1 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹2.1 Cr+₹61,415.20 (0.30%)Rejected-Finance 15 GURU RAM DASS COLONY MITHAPUR JALANDHAR | ₹2.1 Cr+₹61,415.20 (0.30%) | L2 | Rejected-Finance L2 |
| 3 | L3₹2.6 Cr+₹48.6 L (23.4%)Rejected-Finance C 33 3971 GALI NO 6 JALANDHAR CANTT 144005 | JALANDHAR | JALANDHAR | PUNJAB | 144005 | ₹2.6 Cr+₹48.6 L (23.4%) | L3 | Rejected-Finance L3 |
| 4 | L4₹2.6 Cr+₹48.9 L (23.5%)Rejected-Finance | ₹2.6 Cr+₹48.9 L (23.5%) | L4 | Rejected-Finance L4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Due to adverse remarks in WLR of QE Sep 2023 of HQ CEWC |
Tender Value
₹2.6 Cr
EMD Value
₹3.4 L
Closing Date
20 Apr 2024, 6:00 pmClosed
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
ADDN/ ALTN TO CERTAIN BUILDINGS AT MIL STN KAPURTHALA
2024_MES_635538_1
81058/E8
Open Tender
Civil Works
Item Rate
540 days
Jalanhdar Cantt
All documents as per NIT
8 documents required · 8 mandatory
₹2,000
Garrison Engineer Kapurthala
₹3.4 L
Yes
8 Jul 2024
2 Feb 2024
29 Apr 2024
2 Feb 2024
20 Apr 2024
6 Apr 2024
Amount
Note: Please refer Schedule 'A' Notes given on serial page No. 20 to 23 of tender documents.
Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge
Material and labour for glazed ceramic coloured tiles in vertical surface 450 x350 x 7mm thick set and jointed in neat cement slurry pointed in white or colour cement to match the colour, with and including 10mm thick cement screed bed in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge
Material and labour for non-skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but n.exc 0.18 Sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, with and including 15mm thick cement screed bed in CM (1:6) complete all as specified and directed by Engineer-in-Charge
Material and labour for granite slab in single piece 20mm thick machine cut, bedded and jointed in grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing with and including 15mm thick bedding layer in CM (1:6) including making hole for gas pipe all as specified and directed by Engineer-in-Charge
Material and labour for machine cut kota stone for flooring and in riser and steps 20-25mm thick (in single piece for Risers and Treads) laid and jointed in grey cement slurry mixed with pigment to match the shade of slab including cutting and polishing bedded on and including 15mm thick bedding layer in CM (1:3) complete all as specified and directed by Engineer-in-Charge
Material and labour for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations all as specified and directed by Engineer-in-Charge
Demolition of brick/ block masonry built in cement mortar including all quoins, arches, pillars etc and clearing off the premises all as specified and directed by Engineer-in-Charge
Material and labour for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-In-Charge
Use and waste of formwork form rough finished surface of concrete to chajjas and similar works including edges rough finished complete all as specified and directed.
Material and labour for TMT bars 10mm dia and over cut to length bent to shape required, including cranking, bending hooking etc & binding with and including mild steel binding wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge
Material and labour for RCC M-25 (design mix) using 20 mm graded crushed stone aggregate as in chajjas etc. complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster on brick work or concrete surfaces including racking out joints complete all as specified and directed
Material and labour for rendering 12mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified
Material and labour for 15mm thick rendering in cement mortar 1:4 on brick work or concrete surfaces with water proofing compound finished even and smooth etc complete all as specified and directed. Note: WPC shall be measured and paid separately
Material and labour for 5mm thick rendering in CM 1:3 on concrete surfaces finished even and smooth w/o using extra cement as in ceiling etc complete as directed
Material and labour for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge
Material and labour for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over one coat of primer complete all as specified and directed by Engineer-in-Charge
Material and labour for applying two coats of cement base paint on newly plastered or unplastered wall surface including preparation of surfaces, complete all as specified and as directed
Demolition of cement concrete in ground floors and pavings n.exc 15cm thick (below or above ground level) of any description and in any position not otherwise specially provided for all as directed by Engineer-in-Charge
Material and labour for 75mm thick PCC 1:3:6 type C-2 as in plinth protection finishing the surface even and smooth without using extra cement laid to a slope of 1 to 20. It shall be laid in alternate bays, each bay not exceeding 3 m in length with joint to be filled with bituminous mastic filling comprising of mixture of one part of heated hot blown bitumen 85/25 penetration and three parts of heated sand all as directed by Engineer-In-Charge
Demolition of concrete of any description and in any position complete all as specified
Material and labour for water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath and WC's etc shall be as under:- (a) Application of Two component acrylic modified cementitious coating. (i) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement litance, existing coatings and achieve a gripping profile that is clean, dry and free from litance and any other form of surface contamination. the installation instructions in manufacturer's published literature should be strictly compiled with, including but not limited to the following:- (ii) Chipping out any visible cracks in ' V- Groove' pattern as applicable. Special attention on this part cleaning of cracks and then filling those cracks with SIKA latex SBR 100 putyy/ Dr Fixit 302 SBR latex/ perma latex SBR / FOSROC Nitibond SBR latex/ Asian Paints latex as required. Final cleaning of surface with power grinder, wire brush, hair brush and vaccum pressure if required. (iii) Dampen all surfaces immediately ahead of application of Acrylic modified cemetitious coating of Sika Top seal - 107/brush Bond FOSROC/ Dr Fixit/ STP/ CICO. (iv) Whilst the surface is still damp from saturation (SSD), apply one coat of acrylic modified cementitious coating of Sika Top seal- 107/ Brush bond FOSROC/ Dr fixit / STP/ CICO of viscosity as per manufacturer's instructions. (v) Apply glass fabric sheet of Sika Fab 1/FOSROC/Dr Fixit/STP whilst the first coat is wet. (vi) Once touch dry apply second coat of Acrylic modified cementitious coating of Sika Top Seal- 107/ Brush bond FOSROC/ Dr FiXit/ STP/ CICO of viscosity as per manufacturer's instructions on the entire area. (vii) Second coat shall be applied after 6-8 hrs of application of previous coat and in the direction right angle to the previous coat. (viii) The waterproofing coating should be taken to a height minimum 300mm above the finished floor level on the vertical surface.
(ix) It is essential to cure acrylic modified cementitious coating immediately after application (minimum 6-8 hrs drying) for a minimum of 3 to 5 days to ensure full cement hydration and to minimize cracking. (x) A protection plaster (12-15mm thick) in CM 1:3 admixed with appropriate integral water proofing compound has to be applied on the walls. Admixture: -Sika Plastocrete plus/FOSROC Dr Fixit/STP/CICO confirming to IS 2645. (xi) Providing and applying a protection screed of 50 mm thick 1:4 cement sand mortar admixed with Sika plastocrtete over the applied water proofing coating on horizontal surfaces. Admixutre:Sika Plastocrete Plus/ FOSROC/ Dr Fixit/ STP/ CICO confirming to IS 2645. (xii) All the corners and joints should be pre-treated with elastic waterproofing sealing tape with a woven bonding mesh on each surface and an elastic expansions zone in the centre of make Sika Seal Tape S/FOSROC/Dr Fixit/STP. (xiii) The membrane has to be protected in accordance with the manufacturer's recommendations until placement of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accordance with manufacturer's recommendations.
(xiv) waterproofing treatment has to be carried out through applicators authorised. (b) All the joints of pipes and traps within sunken portion shall be sealed properly by Epoxy sealant. (c) All CI traps in sunken slabs to be enclosed with PCC 1:1.5:3 (min 15cm) all round. (d) The sunken portion shall be filled with PCC 1:5:10 type E-2 (using 40 mm stone aggregate) complete all as specified. (e) Providing drainage spout pipe GI 40mm dia bore light grade upto outside of outer wall (Approx 450mm to 600 mm long) including cutting to existing wall and making good the disturbed surface complete all as specified and directed. (f) Providing 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm grade stone aggregate as in flooring for laying floor finish all as specified. Note :- Item No 24(d), (e) & (f) shall be measured and paid separately under item No. 25 to 27 here-in-after.
Material and labour for cement concrete 1:5:10 type E-2 (using 40mm stone aggregate) as in sunken flooring complete all as specified and directed
Supply and fixing drainage spout pipe GI 40mm dia bore light grade upto outside of outer wall (Approx 450 mm to 600 mm long) including cutting to existing wall and making good the disturbed surface complete all as specified and directed
Material and labour for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in flooring for laying floor finish complete all as specified and directed
Taking down chowkhats or frames with shutter (without taking off shutters from the frame) area not exc 1.50 sqm each complete all as specified and directed by Engineer-in-Charge
Taking down chowkhats or frames with shutter (without taking off shutters from the frame) area exc 1.50 sqm but n.exc. 4 sqm each complete all as specified and directed by Engineer-in-Charge
Supply and fixing solid PVC door frame factory made of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening as per specifications all as per SSR Part-I as specified and directed by Engineer-In-Charge
Supply and fixing factory made solid panel PVC moulded door shutter, 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. M.S. frame shall covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail, bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing including fittings all as specified and directed by Engineer-in-Charge
Supply and fixing pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 125 x 60mm filling hollow frame all as specified and directed by Engineer-in-Charge
Supply and fixing pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 105 x 60mm filling hollow frame all as specified and directed by Engineer-in-Charge
Material and labour for PCC (1:3:6) type C-1 using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, pressed steel chowkhats, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered edges and throating complete all as specified and directed by Engineer-in-Charge
Supply and fixing factory made 2nd class, hard wood, 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauge, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc but divided into squares with plain chamfered or rounded mitred and rebated sash bars any numbers sizes of members of shutters as specified and directed by Engineer-in-Charge
Supply and fixing in repair framed work Fe 410-W (Gde-E-250)Quality-A as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering. Doors etc. to be prepared for hanging or sliding with and including hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed
Supply and fixing 25mm flush shutters in cupboards, solid core construction, with block board core and plywood face panels, commercial type both sides complete all as specified and directed
Supply and fixing factory made 2nd class hard wood plain, framed, panelled shutters 35mm thick (any number of panels), with panels of timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density, wood particle board with commercial face veneers : supplied and fitted to chowkhats complete all as specified and directed by Engineer-in-Charge
Supply and fixing alumunium hinges for PVC door shutter, size of hinges in 100mm complete all as specified and directed by Engineer-in-Charge
Supply and fixing aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt in 200mm complete all as specified and directed by Engineer-in-Charge
Supply and fixing extruded aluminium alloys handles fabricated type anodized of size 150mm long complete all as specified and directed by Engineer-in-Charge
Supply and fixing aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt in 250mm complete all as specified and directed by Engineer-in-Charge
Material and labour for preparation of new wooden surface exceeding 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engineer-in-Charge
Material and labour for preparation of old steel surfaces of any description over 10cm girth or width not otherwise described and applying two coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge
Material and labour for preparation of new steel surfaces of any description over 10cm girth or width not otherwise described and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge
Supply and fixing steel window (powder coated) as per IS 13871:1993 of following specification of powder coating material :- (a) Grade-A (Glossy finish) (b) Dry film thickness of 50-60 microns (c) Protection against humidity-No blistering, rusting and loss of adhesion (d) Resistance to heat, detergents and acid/ alkali-No appreciable change of colour Colour of powder coating as per user direction, 1.25mm thick Box type ERW hollow P section of size 60mm x 25mm single rebated comprises glazed Skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T- Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- Section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC (1:3:6) type C-1 Four Nos for each window) including following fitting welded to frame shutter:- (a) Handles of Z Sec 20mm x 100mm long (b) Stopper – 01 No per leaf (c) Cleat 55mm long of hollow square 15mm x 20mm x 63mm welded to hinges – 01 No per leaf (d) Mild steel pintle hinges of size 75mm x 75mm x 12mm-02 Nos per leaf (e) Grills made out of MS square bar 12mm dia welded to FI frame complete all as specified and shown on drawings. Notes : (i) Glass shall be measured and paid separately under appropriate item (ii) Irrespective of whatever shown on drgs, MS gills shall be of 12mm dia MS square bar and paid separately all as specified and directed by Engineer-in-Charge
Supply and fixing steel window (powder coated) as per IS 13871:1993 of following specification of powder coating material :- (a) Grade-A (Glossy finish) (b) Dry film thickness of 50-60 microns (c) Protection against humidity-No blistering, rusting and loss of adhesion (d) Resistance to heat, detergents and acid/ alkali-No appreciable change of colour Colour of powder coating as per user direction, 1.25mm thick Box type ERW hollow P section of size 60mm x 25mm single rebated comprises gauged Skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T- Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- Section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC (1:3:6) type C-1 Four Nos for each window) including following fitting welded to frame shutter :- (a) Mild Steel Hold Fast, 150mm long of 12mm Square bar made to shape – 04 Nos per window (b) Handles of Z Sec 20mm x 100mm long (c) stopper – 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mmx63mm welded to hinges – 01 No per leaf (e) Mild steel pintle hinges of size 75mmx75mmx12mm-02 Nos per leaf. Note : Wire mesh shall be measured and paid separately under appropriate item etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing steel ventilators fixed type with glazing bars etc complete all as specified and directed
Material and labour for hacking out old broken glass from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed
Supply and fixing 4mm thick plain glass in squares n.exc 0.5 sqm each pane and glazing with oil putty complete all as specified and directed by Engineer-in-Charge
Supply and fixing 4mm thick figured glass, pinhead type in squares n.exc 0.5 sqm each pane and glazing with oil putty complete all as specified and directed
Supply and fixing stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.00mm and fixed with tinned tacks/screws with bolts including wooden leeping complete all as specified and directed
Material and labour for framed work such as grills gratings etc with ends of bars shouldered and or riveted or forged into spikes framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framed work of water tanks and similar work coforming to Fe 290 Gde E-165 complete including taking down all as specified and directed
Supply and fixing in repairs 300mm MS ordinary rat rail rod pattern helical springs including roller and roller plate complete all as specified
Taking down GI tubing & connection 15mm dia laid in floor / trenches or fixed to walls complete all as directed by Engineer-in-Charge.
Refixing old 15mm steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed.
Supply and fixing GI tubing 15mm dia medium grade galvanized with all fitting complete to walls & ceiling or laid in floors complete all as specified and directed
Taking down GI tubing & connection 20mm dia laid in floor / trenches or fixed to walls complete all as directed by Engineer-in-Charge.
Refixing old 20mm steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed.
Supply and fixing GI tubing 20mm dia medium grade galvanized with all fitting supply and fixing complete to walls & ceiling or laid in floors complete all as specified and directed
Supply and fixing in repairs 15mm bore CP bib taps fancy type cast copper alloy with crutch or butter fly handle screwed down for iron pipe or for brass ferrule and fixed complete all as specified and directed
Supply and fixing in repairs 15mm dia stop/angle valve, CP cast copper alloy with crutch or butterfly handle, screwed down high pressure, screwed both ends for iron pipe and fixed complete all as directed.
Supply and fixing in repairs vitreous china squatting pan Orissa pattern wash down water closet of size 580 x 440mm, white, with integral foot rests complete fixed in repairs with P or S trap, PVC flushing cistern low level of 10 ltrs capacity including brackets for flush tank, PVC flush pipe and all necessary fittings etc complete all as specified and directed
Supply and fixing in repairs 20mm dia aluminium chromium plated tubular towel rails, D type, 60cm long between flanges, complete all as specified.
Supply and fixing in repairs PVC(SWR) floor trap with grating and diameter of outlet 75mm including jointing to waste pipe fixed with solvent cement complete all as specified and directed.
Supply and fixing in repairs fancy type chromium plated stop valves with long shank and cup (concealed type) cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed for bore of size 15mm complete all as specified and directed
Supply and fixing in repairs for vitreous Chinaware wash basin white, flat back size 550 X 400mm including 15mm dia pillar tap chromium plated, CP waste coupling, waste fittings, union and waste pipe 32mm dia or required length and all necessary inlet, outlet connections complete all as specified and directed by Engineer-in-Charge
Supply and fixing in repairs shower rose 100mm with CP arm of chromium plated any colour or fixing with 15mm pipe (minimum weight 40gm) complete all as specified and directed
Supply and fixing in repairs kitchen sink with drainage board made of stainless steel 1mm thick sheet with plugs, washers and wastes including bedding in cement mortar including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm and bowl size 410mm x 330mm x 160mm complete all as specified and directed
Supply and fixing plate rack of stainless steel of size 750x600x250 mm fixed on walls with screws including taking down complete all as specified and directed
Supply and fixing soap dish chromium plated heavy duty complete all as specified
Supply and fixing in repair 25mm MS curtain rail powder coated with fixing brackets, stops, roller etc as specified and directed.
Material and labour for cutting chases pinning in brick/ stone/ blocks masonary and making good to facings where required and pointing in CM (1:3) to ends or edges of steps, cills, sun shades, shelves, lintel etc and cutting chases for concealed water tubing or etc and making good complete all as specified and directed
Taking down eaves gutters and rainwater pipes including all fittings as specified and directed.
Dismantling of cast iron pipe any diameter jointed with cement mortar or lead including all fittings from wall or floors as specified and directed
Supply and fixing 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-Charge
Supply and fixing 75mm PVC (SWR) pipes single socketed in any length laid in floor complete all as specified and directed by Engineer-in-Charge
Supply and fixing 75mm PVC (SWR) bend complete all as specified and directed by Engineer-in-Charge
Supply and fixing 75mm PVC (SWR) junction single, (single T) equal or unequal complete all as specified and directed by Engineer-in-Charge
All as per item No 80.00 here-in-before but with access door.
Supply and fixing 75mm PVC (SWR) junction double, (double T) equal or unequal complete all as specified and directed by Engineer-in-Charge
All as per item No 82.00 here-in-before but with access door.
Supply and fixing 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-Charge
Supply and fixing 110mm PVC (SWR) bend with complete all as specified and directed by Engineer-in-Charge
Supply and fixing 110mm PVC (SWR) junction single, (single T) equal or unequal complete all as specified and directed by Engineer-in-Charge
All as per item No 86.00 here-in-before but with access door.
Supply and fixing 110mm PVC (SWR) junction double, (double T) equal or unequal complete all as specified and directed by Engineer-in-Charge
All as per item No 88.00 here-in-before but with access door.
Supply and fixing 110mm PVC (SWR) vent cowl complete all as specified and directed
Dismantling water tank PVC 500 ltrs and removing from site complete all as specified and directed
Supply and fixing rotational moulded polythelene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position as per SSR Part-1 of 500 ltrs capacity including fittings complete all as specified and directed by Engineer-in-Charge
Supply and fixing in repair gunmetal globe and gate valve with iron wheel head, screwed both ends for iron pipe 20mm fixed complete all as specified and directed by Engineer-in-Charge
Supply and fixing in repair ball valves 20mm high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed (minimum weight 15mm-142gms/ 20mm-210gms/ 25mm-455gms/ 40mm-690gms) complete all as specified and directed
Dismantling of brick tiles or terracing tiles laid bedded and pointed in cement mortar in single layer on roofs complete all as specified and directed by Engineer-in-Charge
Demolition of mud in roof any thickness including plastering & leeping removed complete all as specified and directed by Engineer-in-Charge
Material and labour for rendering 10mm thick in cement mortar 1:3 on concrete surface finishing even and fair using waterproofing compound complete all as specified and directed by Engineer-in-Charge (WPC shall be measured and paid separately
Roughening surface of old concrete floor or brick/concrete walls by picking, sweeping clean and washing down with water to remove dust etc including brushing neat cement slurry with 3.00 Kg of cement per Sqm complete all as specified and directed
Supply only integral water proofing compound conforming to IS-2645 complete all as specified and directed
Material and labour for preparation of newly plastered surface making surface completely dry and applying a coat of bitumen primer @ 0.40 ltr/sqm and after drying of primer apply APP modified water proofing membrane with non woven polyster reinforcement 3mm thick superior multi polymeric weighing not less than 3kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene (MHHDPE) film consisting of five layers with a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm under and over the APP membrane laid with torching application to the surface complete and sealing the side as well as end laps (overlaps should not be less than 10cm) complete all as specified and directed
Material and labour for 40mm thick brick tiles laid on 15mm screed bed in cement mortar 1:3 with jointing and pointing in cement mortar (1:3) mixed with 5% crude oil by weight of cement all as directed complete all as specified and directed
All as per item No 101.00 here-in-before but except brick tiles
Material and labour for cement concrete type B-0 1:2:4 (12.5mm graded aggregate) as in roof kerbs, rounded or chamfered edges complete all as specified and directed by Engineer-in-Charge
Material and labour for 40mm thick Cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in PCC padding over roof slab complete all as specified and directed by Engineer-in-Charge
Material and labour for PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and directed by Engineer-in-Charge
Demolition and breaking up 200mm bore drain pipe (salt glazed ware, AC or reinforced cement concrete) set in cement mortar complete all as specified and directed
Material and labour for RCC NP-3 drain pipes 200mm dia (internal diameter of pipe) Grade "A" laid in trenches and jointed with cement mortar 1:1 complete all as specified and directed by Engineer-in-Charge
Material and labour for concrete bed to drain pipes 200mm bore in cement concrete (1:3:6) type C-2 (using 20mm graded stone aggregate) including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed
Excavation in trenches n.exc 1.5m wide & n.exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and directed Breakdown of Qty Bldg Works-90 Cum Electrical Works-143.37 Cum
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and directed. Breakdown of Qty Bldg Works-40 Cum Electrical Works-99.37 Cum
Removing excavated material to a distance n.exc. 50m and depositing where directed at a level n.exc.1.5m above the starting point complete all as specified and directed. Breakdown of Qty Bldg Works-50 Cum Electrical Works-44 Cum
Dismantling mild steel work as in roof purlin complete all as specified and directed by Engineer-in-Charge
Material and labour for mild steel rolled section Fe 410-W (Gde-E-250) Quality A as in main and cross beams, hip and jack rafters purlins where connected to common rafters and running rails and guides for sliding door fixed with angle cleats or other connecting plates complete all as specified and directed by Engineer-in-Change
Dismantling corrugated asbestos sheet in roof covering complete all as specified and directed by Engineer-in-Charge
Supply and fixing pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws complete all as specified and directed by Engineer-in-Charge
Supply and fixing pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws complete all as specified and directed by Engineer-in-Charge
Material and labour for preparation of affected concrete and steel surface as in ceiling of roof slab, beams & chajjas by cleaning with metallic wire brush scrupulously and carrying out the following operations stepwise :- (a) Applying rust remover solution on steel bars by using cotton waste swab or by brush and leave the surface for 15-30 minutes. Remover the loose rust particles by scrubbing with brush and wash the steel surface with water. (b) Apply red oxide primer over cleaned steel surfaces. Apply epoxy bonding agent (adherent solution) over cleaned dust freed old concrete surface. Apply polymer mortar with the help of trowel in single or multilayer as an when required during application and finishing the surface even and smooth. Notes :- (a) The bars which are corroded badly need to be strengthen by placing new bars by means of welding with proper splice length and will be measured and paid separately under appropriate item. The rate of item includes necessary formwork, shuttering, scaffolding, staging etc all as specified and directed by Engineer-in-Charge
Uprooting of tree roots from walls/ roof of any girth at any height/ location, of any depth by dismantling brickwork/ PCC by treating it with Ferro herbicide chemical agent on affected area making good the damaged portion as existing by PCC 1:2:4 type B-0 and finished with 15mm thick plaster in 1:4 all as specified and directed by Engineer-in-Charge
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation board/ slabs/ blankets/ AC boards etc any thickness complete all as specified and directed by Engineer-in-Charge
Material and labour for 12mm thick perforated particle board 600 x 600 x 12mm for ceiling on aluminum snap grid frame work of 605 x 605mm and hangers 6mm dia GI upto (1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fastener 12.5mm dia 40mm long complete all as specified and directed by Engineer-in-Charge
Supply and fixing 18/ 19mm thick pre-laminated particle board, exterior grade, pre-laminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work complete all as specified and directed by Engineer-in-Charge
Supply and fixing European style steel clip-on soft close concealed cabinet hinges complete all as specified and directed by Engineer-in-Charge
Taking down carefully existing point wiring of any type (i.e on wooden batten, surface conduit, casing capping or concealed conduit except serviceable existing conduit) complete for light, fan, socket or power point with fittings and fixtures such as ceiling rose, electric fittings, Ceiling fans, Exhaust fans, holders, switches, sockets wooden batten, conduit etc including accessories such as wooden gutties/ rawal plug, screw etc including removing materials from site for taking credit of unserviceable items and re-fixing the serviceable items as per schedule and making good disturbed surface of walls, floors etc, complete all as specified and directed. Notes : (i) The existing conduit of concealed wiring will not be removed from site and same will be reused for point wiring under respective item herein under. (ii) The qty of serviceable / unserviceable items will be as certained by the BOO detailed by GE and serviceable items (such as LED fittings/LED tube and bulb/ ceiling/ Exhaust Fans and geysers) will be refixed under respective item herein under and unserviceable items such as switches, sockets, ceiling rose, holders, brackets, bulkhead fittings, MCB DBs, sunken boxes and fixtures etc. shall be issued to contractor under schedule of credit all as specified and directed.
Material and labour for point wiring with 1.5 Sqmm, PVC insulated but unsheathed multi stranded copper conductor single core FRLS cable, IS-694 marked drawn through existing metallic/rigid PVC concealed conduit including replacement of pressed steel terminal mounting box for mounting fitting P/T switches sockets and providing and covered with 3mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size copper conductor cable as earth wire and connected to common earth dolly for one light/one fan/one bell point controlled by one way switch complete all as specified and directed
All as per item No. 124.00 here-in-before but one light point controlled by two Nos of two way switch
All as per item No. 124.00 here-in-before but one socket point 5Amp on the same board
All as per item No. 124.00 here-in-before but One socket outlet point 5 pin 5Amp controlled by one way switch on independent board
All as per item No. 124.00 here-in-before but wiring with using cable 2.5 sqmm size copper wire (FRLS) and earth wire or PVC insulated (Green colour) 2.5 sqmm size copper wire for one 6 pin socket, 16 Amp on independent board
Supply and fixing point wiring complete with 1.5 Sqmm (nominal area) FRLS PVC insulated sheathed and stranded copper conductor cable ISI marked drawn into and including medium grade PVC conduit concealed (not less than 20mm dia) all necessary fittings and accessories fixed concealed (included chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing surface) and pressed steel terminal boxes of thickness not less than 1.2 mm for mounting fitting like P/T switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws ad cup washers including one continuous run of FRLS PVC insulated green in colour 1.50 sqmm size copper conductor cable as earth wire and connected to common earth dolly for one light/one fan/one bell point controlled by one way switch complete all as specified and directed. (For ORs Md Accn against new SOA 2022 and existing unserviceable and dismantled conduit points).
All as per item No. 129.00 here-in-before but one light point controlled by two Nos of two way switch
All as per item No. 129.00 here-in-before but one socket point 5 Amp on the same board
All as per item No. 129.00 here-in-before but one socket outlet point 5 pin 5 Amp controlled by one way switch on independent board
All as per item No. 129.00 here-in-before but wiring with using cable 2.5 sqmm size copper wire (FRLS) and earth wire or PVC insulated (Green colour) 2.5 sqmm size copper wire for one 6 pin socket, 16 Amp on independent board.
Supply and fixing switch piano flush type, 5 Amps, 240 Volt AC single pole, one way complete all as specified.
Supply and fixing switch piano flush type, 15 Amps, 240 Volt AC single pole, one way complete all as specified.
Supply and fixing socket out let 5 Amp, 5 pin flush type complete all as specified
Supply and fixing Socket outlet multipurpose 2 in 1, 5/6 pin, 5 & 15 Amps, flush type complete all as specified
Supply and fixing Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with and including one SP MCB 20 Amps including top plug complete all as specified and directed by Engineer-in- charge
Supply and fixing decorative wall mounting light fitting suitable for 09 watt LED lamp complete with glass shade including 1 x 09 watt LED lamp complete all as specified
Supply and fixing ceiling rose surface type bakelite 65mm dia three terminal complete all as specified.
Supply and fixing Bell electric AC (Ding Dong) 240 volt SP complete all as specified.
Supply and fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed
Supply and fixing electronic type fan regulator stepped type on existing phenolic laminated sheet etc. suitable for ceiling fan five step fan regulator, electronic type, single phase, including connection complete all as specified and directed
Material and labour for sub main wiring with 1100 volt grade two single core FRLS Wire PVC insulated and unsheathed cable with stranded copper conductor 4 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 4 sqmm multi - stranded copper conductor as earth wire in green colour including taking down old unserviceable sub main wiring complete all as specified and directed. Note : Two runs of 4 sqmm PVC FRLS multi stranded copper cable wire and One run of 4 sqmm PVC FRLS multi stranded copper cable earth wire and One run PVC conduit of suitable size ISI mark will be measured and one unit length.
Taking down old DBs with MCBs, etc complete all as specified
Supply and fixing factory made sheet metal enclosure double door distribution board class IP-43 with 200 Amp rated copper bus bar 240 volts 8 way single pole and neutral link complete all as specified and directed by Engineer-in-Charge
Supply and fixing MCB SP 6 to 32 Amps, 10 KA, B curve all as specified and directed by Engineer-in-Charge
Supply and fixing MCB SPN 40 Amps, 10 KA, B curve all as specified and directed by Engineer-in-Charge
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed by Engineer-in-Charge
Supply and fixing LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Supply and fixing energy saving & environmental friendly long life versatile pressure die-cast aluminium housing luminaire with heat resistant glass and suitable optics for uniform distribution of light 35 watt LED for bldg security lights with high efficiency electronic driver BIS approved, having IP-66 protection, surge protection operative on AC supply 140 volts to 270 volts pre-wired complete with bracket made out of GI pipe medium grade of suitable bore and MS clamp duly painted with two coats of paint all as specified and directed.
Hanging only of ceiling fan and connector to fan including painting with one coat of synthetic enamel paint (tint of paint as per existing) wit spraying machine, writing MES No. including preparation of surfaces, of any sweep complete all as specified and directed
Supply and fixing exhaust fan made of sturdy engineering plastic complete with louvers, shutters, voltage 230V, 50 Hz, RPM 1200 copper winding of sweep 250mm 5 blade, white colour, 230V single phase complete with fixing accessories, exhaust fan connecting up including provision of flexible copper conductor cable from ceiling rose/ connector to fans, including material and labour for providing/ cutting the round hole of required size in wall finishing the same, supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) for fixing of exhaust fan complete all as specified and directed
Supply and fixing exhaust fans of 230 Volt 300 mm sweep ventilator DB double ball bearing heavy duty motor, metal blade with protection steel bird guard and robust complete including Material and labour for providing/cutting the round hole of required size in wall finishing the same supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 23/.0076 copper cable rubber insulated from ceiling rose to exhaust fan motor and writing MES No. with black synthetic enamel paint 2.0cm high complete all as specified and directed.
Supply and fixing bell push, flush type, 5 amp all as specified and directed
Material and labour for boring hole under the road/pavement/hard standing with the help of trenchless technology using ultra sound technique and necessary machine for inserting and including GI 50mm GI pipe suitable working pressure not less than one meter below ground level complete all as specified and directed by Engineer-in-Charge.
Fixing only serviceable light fittings any type and any description obtained from item No 123.00, including necessary electric connection with round flexible wire with multi stranded copper conductor of size 0.50 sqmm, 3 core, 1100 volts grade complete all as directed.
Supply and fixing water heater storage type electric, capacity 25 litres BEE 5 star BEE rating AC 230 volts, 50 Hz vertical type including material and labour for grouting four Nos rack bolt for holding of water heater on wall including making good and match existing surfaces and complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing heavy duty hot and cold flexible pipe with both side flair nut for 20mm and 600mm long connecting with GI pipe complete all as specified and directed
Supply and fixing of switch piano flush button single pole two-way 6 Amp complete all as specified and directed.
Supply and fixing LED retrofit lamp 9 W, 6500K, 220-240V with base cap B-22 all as specified and directed.
Earthing complete in replacement with galvanized steel earth plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level with the top edge of electrode not less than 1.5 metres below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and including GI lead protection pipe of GI light grade 15mm dia upto 7.5 mtrs and watering pipe 20mm bore of GI medium grade with funnel and wire mesh, earth plate covered on all sides with min 150mm thick alternate layers of charcoal, sait all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to earthing point with PCC chamber and RCC cover in 1:2:4 complete with any type of earth work involved all as specified and directed and testing on completion. Note : PCC chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner
Supply, install, testing and commissioning LT Distribution Panel (CPRI approved) cubicle type IP-56 wall mounted, indoor type conforming to IS-5039 of 1983, factory fabricated made out of 2mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC supports. The incoming as well as outgoing MCCBs shall have extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC and having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall colour coated sleeves. A detachable gland plate of thickness not less than 3mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painted with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment, front & back opening type, and fixing 2 Nos danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following (For OR Md Accn) :- (a) Aluminium bus bar for 3 phase 4 wire system of 4 x 100A rated insulated copper strip mounted on resin cast insulator in independent compartment having front openable shutter – 01 Set. (b) MCCB, four pole, 415V, 63 Amps, 25 KA with adjustable overload setting – 01 No. (c) MCB DP 40 to 63 Amp, 10 KA – 04 Nos (d) MCB SP 10 Amp – 01 No. (e) Indicator lamp LED in Red/ Yellow/ Blue colour – One set of three.
Notes : (i) The LT panel board will be fixed to the wall in the place of existing unserviceable panel board with suitable No of fastener and lugs, PVC insulated connectors, PVC sleeves including necessary civil work required to refix the panel as per standard Engineer practice and make the good disturbed surface to match with existing specification of wall. (ii) Taking down of old serviceable meter, recording of meter reading and refixing the same meter in new panel in their respective quarter is included in quoted rate. (iii) LT panel board should be make having valid CPRI type tested approved and as per IS-5039 of 1983. (A copy of valid CPRI type test report to be enclosed while obtaining approval from GE). (iv) SLD diagram for LT panel will be got approved from GE before placing the order and final diagram will be fixed on the front and rear door. (v) Rates for the same deemed to include in the quoted rates.
Taking out old unserviceable LT cables from excavated trenches, ducts, wall, pole etc including removing cable covers, sand, cable joints, pipes, clamps etc, taking out old serviceable cables, cable covers, etc all as specified and directed by Engineer-in-Charge
Material and labour for XLPE insulated, PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete laid in trenches passing through pipes/culverts all as specified and directed by Engineer-in-Charge
Supply and laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-Charge
Material and labour for sand cushioning with 8cm thick layer of sand before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and as directed
Material and labour for GI tube/pipe light grade 40 mm bore laid in trenches or fixed on wall/floor for protection of UG cable complete all as specified and directed.
M/S Kuldip Construction Co.
M/S Mukesh Kumar Gupta
M/S Vinod Kumar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .