Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC | ₹3.2 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹3.3 Cr+₹10.7 L (3.32%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | ₹3.3 Cr+₹10.7 L (3.32%) | L2 | Rejected-Finance Not Being lowest |
| 3 | L3₹3.4 Cr+₹15.1 L (4.70%)Rejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | ₹3.4 Cr+₹15.1 L (4.70%) | L3 | Rejected-Finance Not Being lowest |
| 4 | L4₹3.6 Cr+₹44.2 L (13.8%)Rejected-Finance 100 GIRISH GHOSH ROAD DONBOSCO LILUAH HOWRAH WEST BENGAL 711202 | HOWRAH | WEST BENGAL | 711202 | ₹3.6 Cr+₹44.2 L (13.8%) | L4 | Rejected-Finance Not Being lowest |
| 5 | L5₹3.7 Cr+₹45.0 L (14.0%)Rejected-Finance | ₹3.7 Cr+₹45.0 L (14.0%) | L5 | Rejected-Finance Not Being lowest |
Tender Value
₹4.1 Cr
EMD Value
₹4.8 L
Closing Date
19 Jun 2023, 6:00 pmClosed
HQ CE SHILLONG ZONE
HQ CE SHILLONG ZONE SE FALLS SHILLONG PIN 793011
ADDITION ALTERATION AND SPECIAL REPAIR TO CERTAIN MARRIED ACCOMMODATION AT LEKHAPANI
2023_MES_596048_1
CESZ/LKP/ OF 2023-24
Open Tender
Civil Works
Item Rate
540 days
LEKHAPANI
AS PER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹2,000
GE LEKHAPANI
₹4.8 L
Yes
25 Jul 2023
17 May 2023
21 Jun 2023
17 May 2023
19 Jun 2023
14 Jun 2023
18 May 2023 - 25 May 2023
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding and backing removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
Roughening surfaces of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust, etc. and brushing neat cement slurry with 3.0kg of cement per sqm all as specified and directed
Demolition of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
Taking down cement plaster/terazzo wall plaster, ceiling plaster any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water & removal of debris off the premises etc. complete all as specified & directed.
Demolition of reinforced cement concrete of any description n. exc 15 cm thickness (below or above ground level) complete all as specified and directed.(Shelfs and chimneys) complete all as specified and directed (Note : Demolition shall be carried out using concrete cutter machine without disturbing the structure)
Dismantling of plain or corrugated asbestos sheeting any guage, thickness including Nanital or similar pattern roof coverings with and including making good the wall surface in true level to receive the new roof sheet and filling the gaps with PCC 1:2:4 (12.5mm graded aggregate)complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed
Dismantling of boarding any description fixed in any position complete all as specified and directed.
Taking down of chowkhats or frames not exc. 1.5 sq. m each but with shutters (without taking off shutters from the frames and making good to disturbed surfaces complete all as specified and directed.
Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4.0 sqm each and making good to disturbed surfaces complete all as specified and directed
Supply and fix, factory made pressed steel frames for doors with one or more rebates, of size 125mmx60mm, made out of 1.25mm thick sheet, including necessary fixing lugs, hinges, lock strike plate, etc, including one shop coat of red oxide primer on exposed surface and one coat of black bitumious paint on unexposed surface complete all as specified and directed.
Supply and fix, factory made pressed steel frames for doors with one or more rebates, of size 105mmx60mm, made out of 1.25mm thick sheet, including necessary fixing lugs, hinges, lock strike plate, etc, and one shop coat of red oxide primer on exposed surface and one coat of black bitumious paint on unexposed surface complete all as specified and directed.
S & F for aluminum powder coated (powder coated of required colour and minimum thickness of powder coating 50 micron) three track (2 Nos shutter & 1 No Gauzed shutter) sliding windows frame top & sides of size 92 x 31.75 x 1.50 mm bottom of size 92 x 31.75 x 1.50mm and shutter top & bottom of size 40 x 18 x 1.55 mm and lock side shutter frame of size 40 x 15 x 1.45mm with rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including stainless steel wire mesh 0.36mm nominal dia with 1.40mm average aperture and fixed with stainless steel wire staples and fixing 5mm thick glass with necessary rubber beading gasket etc complete all as specified and directed.
S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and directed.
S & F Aluminium powder coated( minimum thickness of powder coating 50 micron ) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
Supply and fixing Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified and directed
S & F for aluminium swing type louvers with locking arrangement incl 4mm thick frosted sheet glass strips of suitable size fixed to aluminium frame and other necessary suitable arrangement complete all as specified and directed. (Note : Aluminium frame shall be measured and paid seperately under respective item)
S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed. Note:(M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush Cup board door shutter of size 18mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisturproof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
S & F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush type as in shelves of 18mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant fixed over stainless steel L shaped brackets which should withhold as average weight of 20-30 Kg and fixed with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed.
S & F factory made Flush shutters 30mm thick, solid core construction, with block board core and ply wood face panels, commercial type on both sides complete all as specified and directed.
S & F factory made Second class hardwood glazed and skeleton door shutters of 35mm thick, in three equal penels open rebated and prepared to receive glass, gauze, etc, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc complete all as specified and directed.
S & F factory made Second class hardwood half glazed and half panelled door shutters 35mm thick, open rebated and prepared to receive glass, gauze, etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, and half panel with 9mm BWP commercial ply etc complete all as specified and directed.
S & F 75mm size 15-18mm wide flap of heavy duty stainless steel hinges fixed with stainless steel screw complete all as specified and directed.
S&F 100mm size Stainless steel Hasp and staple, safety type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F door seal aluminium rod with nylon brush of approved colour fixed to shutter with and incl 20 mm steel wooden screws complete all as specified and directed.
S&F Floor door stopper doubled leged of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
Supply and fixing 25 mm dia MS chromium plated cupboard hanger rod fixed inside cupboards with and including making necessary holes of 75 mm depth and making good the disturbed surfaces in PCC (1:2:4) type B0 (using 12.5 mm graded aggregate) complete all as specified and as directed
S&F MS Chromium plated curtain rod 25 mm dia with and incl MS Chromium plated decorative round funnels on either end and provide a visually balanced appearance incl MS Chromium plated brackets fixed to wall with 30mm wooden steel screws and PVC rawal plug anchors and installation as fixed in repairs complete all as specified and directed.
S&F 150 mm size, aluminium anodised , barrel tower bolts of extruded section complete all as specified and as directed.
S&F 200 mm size, aluminium anodised , barrel tower bolts of extruded section complete all as specified and as directed.
S&F 250mm length of bolt, aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F 100mm stainless steel butt hinges, with stainles steel hinge pin, anodised & fixed to PVC door using stainless steel screws complete all as specified and directed.
S&F Heavy duty powdered coated capsule type door closure of suitable size , fixed to steel frame with necessary screw complete all as specified and directed.
S&F 125mm size aluminium handles, cast type, anodized and fixed complete all as specified and directed.
S&F 150mm size aluminium handles, cast type, anodized and fixed complete all as specified and directed.
Supply and fix galvanised mild steel wire cloth of 0.36mm nominal dia of wire and average width of aperture and 1.4mm and fixed to angle iron frame with tinned faces or galvanised wire staples complete all as specified and directed
M&L 4 mm thick frosted glass, and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed
S & F stainless steel soft close hydraullic clip of size 2mmx8mmx15mm in concealed cabinet hinges fixed with stainless steel screw complete all as specified and directed
S & F 50mm dia polished hard wood knobs fixed with thread screw and nut complete all as specified and directed
S & F Stainless steel Magnetic door catcher Magnet of size 50mmx15mmx15mm fixed with Gypsum screw on shelf/sides wall and shutter complete all as specified and as directed
Cutting holes in brick walls built in cement or cement lime mortar for inserting hold fasts, etc and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1, cutting exceeding half brick but not exceeding one brick complete all as specified and directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed
Material & labour for false ceiling with GI frame work for EXPOSED GRID SYSTEM of grid size 600 mm x 600 mm, GI powder coating at bottom and comprising of GI perimeter wall angle with two equal flanges of 25 mm fixed to surrounding wall / partition using nylon sleeves and screws at 450 mm centre to centre. Main Tee 0.55 mm thick having 35 mm wide flange and 25 mm high web suspended from the soffit @ 1200 mm centre to centre with with wire of 2.5 to 3 mm dia from purlin , Cross Tee - 1200, 0.55 mm thick having 35 mm wide flange and 25 mm high web inserted fixed into the slots of Main 'T' @ 600 mm centre to centre to form a grid of 1200 mm x 600 mm, Cross Tee - 600, 0.55 mm thick having 35 mm wide flange and 25 mm high web shall be placed perpendicular to the Cross Tee - 1200 mm to finally form a grid of 600 mm x 600 mm . complete all as per manufacturer instructions
S&F 4mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation and acoustic purpose to be placed in the grid system with provision of light fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detector etc. complete all as per manufacturer instructions and directed
S & F Rolled mild steel sections conforming to Fe 410 (Gde E250 ) quality A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails , guides , fixed with angle cleats or other connecting plates complete all as specified and directed
M&L for pre-painted hot dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed
M&L for hot dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550MPa as in ridge/valley/gutter/eaves boardings fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and directed
M&L for 15mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like over 15mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
S & F stainless steel sinks of 1.00 mm thick sheet for kitchen with plugs, washers, waste pipes, including bedding in cement mortar to dwarf wall or including fixing cast iron cantilever brackets and connecting union to pipe overall size 495mmx420mm bowl size 410mm x 330mm x160mm with and including PVC waste pipe and CP waste coupling 32 mm dia and making good to disturbed surfaces, fixed in repairs, complete all as specified and directed
Formwork to soffits of suspended slabs such as roof slab , floor slabs , landing ; and similar work not exc 200mm (horizontal or sloping) thick; rough finished flat surfaces of concrete complete all as specified and directed
M&L RCC 1:2:4 Nominal mix B-1(20mm graded aggregate) as in as in slab supported on walls beams & columns in floors, roofs, landings, balconies, canopies, deck slabs & in shelves & the like etc complete all as specified and directed
M&L Mild steel TMT bars of Grade 500D 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F framed work such as grills gratings, etc., with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed baluster; walk ways; railings; framed work or water tanks and similar work conforming to Fe 290 gde E 165 complete all as specified and directed
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade YST.-240 complete all as specified and directed
M &L Brickwork with subclass 'B' old size bricks, straight or curved on plan exc 6m mean radius built in Cement mortar 1:4 complete all as specified and directed
M&L Brickwork with subclass 'B' bricks, old size brick straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed
M&L for rendering 10.mm thick plaster in cm 1:6 on fair faces of brick work or concrete surfaces including finishing top even and fair complete all as specified & directed.
M&L for rendering 15 mm thick in cement mortar 1:4 in two layers (10+5mm)on fair faces of brick work or concrete surface of walls with top layer mixed with water proofing compound and finished fair and even complete all as specified and directed. Note: WPC shall be measured and paid separately.
M&L for rendering 5 mm thick in cement mortar 1:3 on fair faces of ceiling of concrete surface, finished even and smooth (without using extra cement) complete all as specified and directed
M&L for taking down existing plaster over window chajja and facia similar location and applying primer coat (single coat) of URP (as per manufacturer instruction) mixed with cement in proportion 1:1 the and applying 15mm thick cement plaster in CM 1:4 mixed with WPC as per manufacturers instructions and ,complete all as specified and as directed. Note : The rate quoted is inclusive of necessary scaffolding upto double storied bldg.
M&L for 0.56mm thick Plain, Aluminium sheeting, Alloy 31000 H4 fixed to wall, ceiling as in crumple joints with necessary drilling holes oval type double the size of the screw fixed with wooden/Rawl plug with gypsum screws and washer etc complete all as specified and directed.
M & L 50 mm thick, plain cement concrete 1:3:6, type C-2, using 40 mm graded mechanically crushed stone aggregates, laid in 1:20 slope as in plinth protection/pavings including making joints at 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/ 25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement, complete all as specified and directed. Note: The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
S & F 18/20mm thick pre formed filler board as in crumple/expansion joint complete fixed in between crumple joint cut to size and fixed complete all as specified and directed.
M/L Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in Hardstanding/Footpath/ pavings , 50mm thick, finished even and fair complete all as specified and directed.
M & L for Chequered cement concrete tiles cast in rubber moulded glossy finish of approved colour of size 25cm x 25cm x 22mm thick with mixture of white and grey cement in equal proportions and pigments set and jointed and pointed in neat cement slurry in floor including layer over 15mm thick bedding of cement mortar (1:6) complete all as specified and as directed
M&L Cement concrete 1:2:4 Type B 2 (using 40 mm graded stone aggregate) as in suface channels and drains complete all as specified and directed
Extra for forming fair finished drain or channel 30CM inner girth in cement concrete using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and directed
Material and labour for precast Reinforced Cement Concete cover slab type M-15(Nominal Mix) (using 20 mm graded stone aggregate), set in Cement Mortar (1:4) complete all as specified and as directed. Note:Reinforcement to be measured separately
S & F FRP Manhole cover of heavy duty size 750mmx750mm of capacity 5 tone complete all as specified and directed
Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundations or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.50 m in depth and getting out in soft/loose soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm as in soft/loose soil complete all as specified and directed
Removal of excavated material to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
S&F of 160 mm dia PVC (SWR) pipes type B single socketed in any length with rubber ring joints laid in floors/ trenches and making good complete all as specified and directed.
Demolition of lime concrete/ lean concrete/ brick bats from sunken portion exc. 15 cm thickness (above ground level), including removal of rubbish outside MoD land, complete all as specified and directed.
Material and labour for water proofing treatment to sunken floor with the following course of treatment as specified below, all as per manufacturer’s instructions complete and all as directed by Engr-in-Charge :- (i) Cleaning top surface of floors/slabs and laying 50mm thick (avg) PCC of grade M10 (Nominal mix), mixed with WPC as per manufacturer’s instruction laid in slope 1:20 towards spouts including coveting corners. (ii) 15 mm thick plastering in CM (1:4) on sides mixed with WPC as per manufacture’s instruction. (iii) Applying 1st layer of slurry of cement @ 0.488 kg/sqm mixed with acrylic based polymer modified Cementitous compound @ 0.253 kg/sqm. This layer shall be allowed to air cured for 4 hrs. (iv) Applying 2nd layer of slurry of cement @ 0.242 kg/sqm mixed with acrylic based polymer modified Cementitous compound @ 0.126 kg/sqm. This layer shall be allowed to air cured for 48 hrs. (v) Applying a coat of industrial bitumen 85/25 conforming to IS:3384:1986 penetration @ 1.50 kg/sqm on plastered and concrete surface. (iv) Providing 150 micron thick polyethene sheet in two layer (each 75 micron measured dry on dry surface over a coat of PU primer including preparation. (vii) 2 Nos 32mm bore GI medium grade 450mm long spout to be provided through external wall to drainout accumulated water. (viii) Sunken floor shall be tested for water tightness as specified at para 12.3 of PS. (ix) Sunken portion shall be filled with lean concrete of grade (1:3:6) type C-2 (using 40mm graded stone aggregate)
Material and labour for PCC (1:2:4), type B-1, using 20 mm graded mechanically crushed stone aggregates, as in padding concrete to sunken floor, covering to junction of floor and vertical walls including chamfering on edges, complete all as specified and directed
Supply only integral water proofing liquid confirming to IS 2645-1975, complete all as specified and directed
Material and labour for Steel water tubes, 40 mm bore, light grade, galvanized, as in spout for sunken floor, fixed in wall, inside end fixed with wire netting and external beveled edge at 45 degree,complete all as specified and directed
Material and labour for Lean concrete (1:5:10), type E-2, using 40 mm brick coarse aggregate, as in sunken portion, complete all as specified and directed
M&L for 25mm thick cement concrete type B-0, 1:2:4 (using 12.50mm graded stone aggregates), in sub base of floors, finished even & fair to receive bedding layer of cement mortar complete all as specified and directed.
M&L coloured Glazed ceramic tiles in vertical surface 300x 450x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match laid over & including 10 mm thick rendering as in backing wall plaster in cement mortar (1:4) complete all as specified & directed.
M&L coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified & directed.
M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick (approx Size 400x400) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified & directed.
M&L for coloured Matt finished joint free ceramic tiles of 7mm to 8mm thick (appx size 600mmx600mm) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified & directed.
M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in cement mortar 1:4 for vertical surfaces such as skirting etc complete all as specified & directed.
M & L Green Marble work 15mm thick (table rubbed and polished) in corner shelf design/Rectangle design fixed independently quarter circle of dia 20-25cm each at Bath and Kitchen incl rounding the edges, like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and as directed.
M&L for plain cement concrete (1:3:6), type C-1, (using 12.5mm graded crushed stone aggregates) as in bed block, blocks for holdfasts, filling in pressed steel door frames , benching slightly rounded or chamfered angles & throating etc including necessary use & waste of form work complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over 20mm cement screed bed in 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. Note : (Kota stone fixed in staircase tread shall be of single piece)
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10mm thick cement screed bed in 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. Note : (Kota stone to be fixed in staircase Riser shall be of single piece)
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
Taking down gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F PVC (SWR) pipes 110mm dia of single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
S&F PVC (SWR) pipes 75mm dia of single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
S&F PVC (SWR) bends 110mm dia any radius provided with access door complete all as specified and directed.
S&F PVC (SWR) bends 110mm dia any radius without access door complete all as specified and directed.
S&F PVC (SWR) bends 75mm dia any radius provided with access door complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) 110mm dia any radius provided with access door complete all as specified and directed.
S&F PVC (SWR) junction single (single T) 75mm dia any radius provided with access door complete all as specified and directed.
S & F PVC (SWR) reducers 110/75mm complete all as specified and directed.
S & F 75 mm PVC (SWR) vent cowl complete all as specified and directed.
S&F 150x150mm Salt-glazed stoneware gully traps, square or round mouthed, type `P' complete all as specified and directed
Taking up or down steel water tubing and connections, including cleaning for refixing or removal from site, for bore of pipes 15mm dia complete all as specified and directed.
S&F 15mm dia bore of pipes, medium grade, galvanised iron, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified & directed.
Taking up or down steel water tubing and connections, including cleaning for re-fixing or removal from site, for bore of pipes 20mm dia complete all as specified and directed.
S&F 20mm dia bore of pipes, medium grade, galvanised iron, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified & directed.
Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubings or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete.
S&F in repairs vitreous china squating pan, 'Orissa' pattern, size 580x440mm white, with integral foot rests, including 100mm cast iron 'P' or 'S' trap and 100mm cast iron sanitary connection socket to fit WC outlet including connection to trap, to flushing pipe, anti-syphonage pipe etc. complete including making good to floor complete all as specified and directed.
S&F in repairs Wash basins, vitreous china, white, flat back of size 550x400mm including brackets and cutting for and pinning in ends of brackets or erecting stand 32mm dia waste fittings, brass, chromium plated with long screwed shanks and fly nuts, 32mm dia HDPE waste pipe and including new brackets complete all as specified and directed.
S&F in repairs Wash basins, vitreous china, white, flat back of size 450x300mm including brackets and cutting for and pinning in ends of brackets or erecting stand 32mm dia waste fittings, brass, chromium plated with long screwed shanks and fly nuts, 32mm dia waste pipe and including new brackets complete all as specified and directed.
S & F in repairs 10 litres capacity, PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and suitable flush pipe PVC 32mm dia complete all as specified and directed.
M&L 75mm dia PVC (SWR) floor trap/nahani trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S/F Stainless steel Grating doom 125 mm dia with waste hole of complete all as specified and directed.
Material and labour for PVC connections of PTMT, non corrosive, with nuts & washers on both ends, 450 mm longs suitable for 15 mm bore, ISI marked, fixed in repairs, complete all as specified.
S&F 40 mm Low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqm as in waste water pipes complete fixed in wall, ceiling or in floors complete all as specified and directed.
S&F in repairs 15mm bore dia angle valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed.
S&F 15mm bore dia angle valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed.
S&F in repairs 15mm bore stop valve cast copper alloy, fancy type, chromium plated,concealed type long shank and cup screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed.
S/F in repairs Pillar taps, Long swan neck cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe 15mm bore complete all as specified and directed.
S/F in repairs Long body Bib taps cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified and directed.
S&F bib taps, CP cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15 mm bore and fixed complete all as specified and directed
S & F 5mm PVC sheet Mirror Cabinet of size 400 x 500mm as per cat Part No 554 of Prayag or equivalent in list of approved make complete all as specified and as directed
S & F 15mm bore Bib tap sink cock Regular spout with long neck and flage as per Model Casa Cat Part No 9216 of Make prayag or equivalent in list of approved make complete all as specified and as directed
S & F wall mixer with L Bend with provision for over head shower of Model casa Cat No 9275 of Make Prayag or equivalent in list of approved make complete all as specified and as directed
S & F 100mm chromium plated overhead shower ABS with Brass Arm 225mm and flange complete all as specified and directed
S&F PTMT shelf fixed with and including chromium plated brass screws and wooden/plastic cleats (Min weight 300gms) complete all as specified and directed
S & F Towel Ring of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (min weight 90 gms) complete all as specified and directed
S&F Brass chromium Plated towel rail 600mm long with brackets 20mm dia fixed to wall with chromium plated brass screws complete all as specified and directed
S&F Wall Mount Modern Kitchen Utensils Dish Rack Stainless Steel 1st grade (31 x 10 x 30 Inches) Model KRJ-3 Make Jainko or equivalent in list of approved makecomplete all as specified and directed
S&F stainless steel peg set of 6 peg, 45 centimeter long, complete all as specified and directed
Dismantling RCC water tanks exc 250ltr but not exceeding 500ltr capacity and removing debris outside defence land complete all as specified and as directed.
Demolition of RCC Tank of 500 to 1000 ltr capacity and removing debris outside defence land complete all as specified and directed
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR-Part-I 500 Litres capacity complete all as specified and directed
S&F in repair 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball, screwed for iron pipe & fixed (Minimum weight 210 gms) complete all as specified and directed
S/F in repairs 20mm Gun metal,globe or gate valve, with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed
Disconnecting existing tanks, of capacity exc 250ltr but not exceeding 500ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. Note:(Cleaning & repairing, shall be measured separately)
M & L Cleaning and removing all scale and dirt, etc, from tanks of any capacity and from mouths of circulating pipes, etc. complete all as specified and directed
M&L for water proofing treatment to RCC roof comprising with APP (Atactic Polypropylene Polymer) base polymeric membrane 3 mm thick (minimum) weighing 3.5 Kg/Sqm reinforced with polyester non-woven fabric (weight not less than 160 gms/sqm) laid on surface applied with bituminous primer @ 0.40 litres per sqm, by torch application method with overlaps shall be minimum 150 mm on the transverse direction and 75 mm on longitudinal direction including cleaning the surfaces with brooms / cotton clothes over 15 mm thick screed bed or bedding layer of mortar in cement mortar 1:3 with using and including water proofing compound as per manufacturer's instruction and carrying out water proofing test against leakage and seepage with and including taking down existing treatment complete all as specified and directed
M&L 2.5 to 3mm thick sun board with laminated vinyl sheet including screen printing of bldg No / Qtr No as per sample kept in GE Office of size 300mm x 225mm each includig fixing upto 2nd floor height includig necessary PVC rawl plug and SS screws of 25mm long complete all as specified and directed
M/L Cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edge including necessary form work complete all as specified and directed
M&L Providing cement concrete 1:2:4 Type B-1 (using 20 mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed
Complete removal of existing treatment on wall/ roof projections incl facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust loose paint etc by skilled labour complete all as specified and as directed
M & L for waterproof cement based putty (Interior grade )@ 1 Kg (undiluted) per sq mtr of average thickness 1mm over the plastered / old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust etc by skilled labour as per following steps : - Step 1 : Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 Kg putty per minute. Step 2 : Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a max pressure 3300 PSI Step 3 : Allow 6-8 hrs time to dry the putty surface Note : (a) The work pertaining to periodical services shall be executed from authorized applicator through manufacturer of which the materials i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by GE. (b) Cost of Scafolding upto 10 mtr height of building is included in this item. (c) Masking of window/doors during spray painting using polythine film is included in quoted rate of this item (d) After completion of painting work contractor shall remove & clear all the droplets/stain of paint left on the floor glasses & joinery, mats etc included in quoted rate.
M & L for waterproof cement based putty (Exterior grade) @ 1 Kg (undiluted) per sq mtr of average thickness 1mm over the plastered / old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanicsm) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust etc by skilled labour as per following steps : - Step 1 : Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 Kg putty per minute. Step 2 : Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a max pressure 3300 PSI Step 3 : Allow 6-8 hrs time to dry the putty surface Note : (a) The work pertaining to periodical services shall be executed from authorized applicator through manufacturer of which the materials i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by GE. (b) Cost of Scafolding upto 10 mtr height of building is included in this item. (c) Masking of window/doors including taking down during spray painting using polythine film will be included (d) After completion of painting work contractor shall remove & clear all the droplets/stain of paint left on the floor glasses & joinery, mats etc included in quoted rate.
M & L for applying two coats of acrylic distemper over with and including a coat of primer using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface scomplete all as specified and directed. Note : (a) Sanding of surface to be done by mechanical sander with 1500-2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper mashking to carried before primer and paint application. (b) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the materials i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by GE.
M & L for one coat of acrylic water based exterior grade primer @ 0.9 ltr (undiluted/10 sqmtrs) diluted with water 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed. Note : (a) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the materials i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by GE. (b) Cost of Scafolding upto 10 mtr height of building is included in this item.
M & L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive and color stay Techonology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (Undiluted)/10 Sqm with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow spreed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface in both coats of paint complete all as specified and directed. Note : (a) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the materials i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by GE. (b) Cost of Scafolding upto 10 mtr height of building is included in this item.
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
M&L Painting 2 coats of synthetic enamel paint on new steel and iron surfaces of any description over 10 cm in width or girth including preparation and one coat of red oxide primer complete all as specified and directed
M&L for preparing the new plastered surfaces and applying three coats of white wash on walls complete all as specified and directed
M&L for preparing the old plastered surfaces and applying three coats of white wash on walls complete all as specified and directed
M&L for Preparation of new surfaces and applying 3 coats white wash on ceiling surfaces complete all as specified and directed
M&L for Preparation of old surfaces and applying 3 coats white wash on ceiling surfaces complete all as specified and directed
M&L Painting 2 coats of synthetic enamel paint on old steel and iron surfaces of any description over 10 cm in width or girth including preparation and one coat of red oxide primer complete all as specified and directed
Taking down aluminium point wiring of light points, fan, socket out let on TW battens/PVC pipes/casing & caping including material like sockets, switches, ceiling roses, regulators, light fittings etc and removing the materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed
M&L for Point wiring complete as specified with 1100 volt grade 1.5 sq.mm. (nominal area) two runs of single core FRLSH PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including concealed type rigid non-metallic PVC conduit of suitable size but not less than 20mm dia , with all fittings, fixed on wall/ceiling /floor including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH(ISI marked) but green in colour as continuous earthing wire for One light /Fan /Ex Fan point controlled by one, one way switch complete all as specified & directed Note :- (i) Modular Plates & Covers and Modular Metal Boxes/PVC Boxes will measured and paid separately under relavant items. (ii) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
All as per item 159 above but for One Bell/Buzzer point controlled by one way bell switch
All as per item 159 above but for One light point controlled by two 2 - way switche (for stair case lights only)
All as per item 159 above but for One socket outlet 3 or 5 Pin, 6 Amp on same board.
All as per item 159 above but for One socket outlet 3 or 5 Pin, 6 Amp on independent board
All as per Ser item No 159 above but with 2.5 sqmm copper cable for socket outlet 3 pin 15 Amps complete all as specified and as directed.
S&F modular switch 6 Amp one way 1 module 230 V AC complete all as specified and directed.
S&F modular bell push, 6 Amps, 1 module single pole complete all as specified and directed.
S&F modular switch 6 Amp two way 1 module 230 V AC complete all as specified and directed.
S&F modular switch 16 Amp one way 1 module 230 V AC complete all as specified and directed.
S&F modular socket outlet 6 Amp 2 module intel multi socket for all pins 230 V AC complete all as specified and directed.
S&F modular socket outlet 16 Amp 2 module and 6/16 Amp heavy duty 230 V AC complete all as specified and directed.
S&F modular ceiling fan regulator, electronic step type, 5 speed AC 230 volts, 2 module complete all as specified and directed.
S&F Modular TV Socket outlet, 1 module complete all as specified and directed.
S&F 1/2 module Metal Flush Box including white cover plate with frame for fixing of modular switches/sockets etc. complete all as specified and directed
S&F 2 module Metal Flush Box including white cover plate with frame for fixing of modular switches/sockets etc. complete all as specified and directed
S&F 3 module Metal Flush Box including white cover plate with frame for fixing of modular switches/sockets etc. complete all as specified and directed
S&F 4 module Metal Flush Box including white cover plate with frame for fixing of modular switches/sockets etc. complete all as specified and directed
S&F 6 module Metal Flush Box including white cover plate with frame for fixing of modular switches/sockets etc. complete all as specified and directed
S&F 8 module Metal Flush Box including white cover plate with frame for fixing of modular switches/sockets etc. complete all as specified and directed
S&F call bell multi music type AC 230 Volts single pole complete all as specified and directed.
S&F ceiling rose, three terminal, PVC/polycarbonate, isolated body, ISI marked complete all as specified and as directed.
S&F PVC/polycarbonate angular/straight type Lamp Holder insulated body with back plate angle type suitable for batten complete all as specified and directed
S&F LED Blub 9 watt Self Ballasted Retrofit type lamp with PBT body shell and DC Diffuser CCT 6500 K with fitting complete all as specified and directed.
S&F LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC decorative box type with driver, holder including fitting fixed on wall/ceiling and connecting up complete with 3 core flexible cable white of suitable size including taking down old unsv tube light fitting and making necessary connection complete all as specified and directed.
S&F LED Tube lights fitting 1 x 9/10 Watt, 2 feet , 220V AC decorative box type with driver, holder including fitting fixed on wall/ceiling and connecting up complete with 3 core flexible cable white of suitable size including taking down old unsv tube light fitting and making necessary connection complete all as specified and directed.
S&F LED Bulkhead luminaires 1 x 9/10 Watt fitting in engineering plastic housing with clear prismatic diffuser complete with all accessories and connecting up with 3 core flexible cable white of suitable size including taking down old unsv fitting and making necessary connection complete all as specified and directed by Engr-in-Charge.
S&F LED building security light fitting 1 x 35 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protection incl mounting bracket of suitable size and connection complete all as specified and directed.
Taking down carefully old unserviceable ceiling fans / Exhaust fans complete, removing its blade and deposit to the MES Store yard by the contactor complete all as specified and directed. .
Over hauling of ceiling fan of any sweep/ make i.e. opening of fan and cleaning ball bearing, filling grease/ oil and changing of u/s cotter pin, nut, screw, check nuts and bolts as required incl. cleaning of body, blades, down rods, canopies etc and re-assembling complete all as directed.
M&L painting of ceiling fan / exhaust fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
Fixing only ceiling fan any make/ sweep and connecting up with existing electric circuit complete Note: Fan shall shall be provided from MES store yard.
S&F Fan hooks made of MS clamp bent to proper shape including nut & bolts and drilling cutting roof as required at site and fixing fan hook with existing steel reinforcement complete all as specified and directed.
S&F ceiling fans 1200 mm sweep, AC 230 V complete with blades, down rods and connected accessories, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with (BLDC) brushless direct current motor suitable to run with regulator to control the speed and connection complete all as specified and directed. Note: Fan regulator shall be measured and paid separetely
S&F Exhaust fans with louvers 300 mm sweep, 1440 RPM, Heavy duty single phase 240 Volts, AC 50 Hz, steel body and connecting up including louvers including making necessary opening on stone /brick masonry wall of suitable size, finishing it properly and making good with matching colour with the surroundings provision of cable 3 core of suitable size from ceiling rose to fan complete all as specified and as directed.
S&F Exhaust fans made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm and connecting up including louvers including making necessary opening on stone /brick masonry wall of suitable size, finishing it properly and making good with matching colour with the surroundings provision of cable 3 core of of suitable size from ceiling rose to fan complete all as specified and as directed.
S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one number single pole MCB 20 Amps , 240 Volts complete all as specified and as directed.
M&L for providing concealed submain wiring with two single core 6.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through and including PVC Conduit complete as per direction including 6.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wire including taking down/removing old one & cutting chases in walls by cutter and making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note :- (i) Three runs of single core 6.00 Sqmm multi stranded copper cable and one run of PVC conduit shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire shall run inside the conduit.
M&L for providing concealed sub main wiring with two single core 4.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through and including PVC Conduit as per direction complete including 4.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wire including taking down/removing old one & cutting chases in walls by cutter and making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note :- (i) Three runs of single core 4.00 Sqmm multi stranded copper cable and one run of PVC conduit shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire shall run inside the conduit.
Supply & fix Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 12 way (2 + 10 way) single pole and neutral link, including cutting chases, concealing DB in wall making good disturbed surfaces after taking down old u/s any type, complete all as specified and as directed.
S&F MCB single pole and neutral (SP&N) 40 Amp 240 volts 10 KA 'C' series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable, complete all as specified and directed.
S&F MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA 'C' series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable complete all as specified and directed.
Supply, Installation, Testing & commissioning of Indoor type, wall mounted (with bolts and nuts) meter cabinet panel of size 1000 mm x 900 mm x 200 mm and made out of 2 mm thick CRCA MS sheet of suitable size to operate on 3 phase 4 wire system 415 Volts AC, double door with first door having glass window for viewing KWH meter and other doors shall be opeque and suitable for mounting switch gear, electrical meters including pre wiring from Bus bar to Meter and Meter to MCBs (for pre wiring use 6.00 Sqmm single core copper cable and suitable size of lugs for connecting from Busbar to meter and meter to MCBs) including bottom gland plate with sufficient numbers of circular cable entry holes. All door should have neoprene rubber gasket and locking arrangements. The cabinet shall be painted both internally and externally with powder coated paint. The cabinet shall be dust and vermin proof with degree of protection IP 43. The cabinet shall be comprising with the following accessories:-
ITEM No 201 CONT... Incoming:- (i) MCCB 100 Amps FP, 415 Volt 25 KA adjustable thermal & fixed magnetic setting Ics 100% = 01 No (ii) Phase indicating lamp LED type – 1 Set of three. (iii) Aluminium bus bars for 3-phase & nuetral of current carying capacity up to 200Amps dully mounted on FRP/DMC insulators and necessary drilling for connections and duly covered with heat shrinkable PVC sleeves of standard colour code. OutGoing:- (iv) MCB SPN 40Amps, 10KA - 10 Nos. (08Nos for meters, 02 for Spare) (v) Single phase electronic meters temper proof LCD display with polycarbonate cover 230 V, 10 - 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed- 08 Nos. (Note:-Contractor should hand over the existing energy meter to E/M store yard after noting down the location ie Qtr No, Meter Sl No, Final reading with date duly signed by occupant/Unit rep.)
Disconnecting electrically Indoor type panel board any size, cutting and disconnecting pedestal, refixing the same, partially concealed on wall after cutting grooves and making good disturbed surfaces and reconnecting electrically complete all as specified and directed.
M&L dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including punned thickness up to 18 cm and consolidation, complete all as specified and directed. Note :- Punned thickness only will be considered for payment.
Supply & lay Brick sub class B locally available best quality laid in trenches above sand cushioning for cable protection complete all as specified and directed.
Supplying, laying testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of 35 sqmm 3.5 core all as specified and as directed. Note : Excavation and earthwork, sand cushion, brick and protection pipe shall be measured & paid separately in respective items.
Supplying, laying testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of 10 sqmm 2 core all as specified and as directed. Note : Excavation and earthwork, sand cushion, brick and protection pipe shall be measured & paid separately in respective items.
M&L for light grade galvanized pipe ISI marked with all fitting ISI marked, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc of bore 40 mm complete all as specified and as directed .
M&L Rigid non-metallic PVC conduit 20mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed.
S&F of RG-11 co-axial TV cable with electrolytic grade solid annealed copper, aluminium foiled and aluminium wire braided duly PVC insulated, black colour complete all as specified and directed.
Boring of holes under road, pavement hard standing by using trenchless technology or using ultrasound technique or by machine or By manual to insert pipe of upto 50 mm light grade GI pipes as per site requirement with all fittings such as bends, elbows, Tees, etc, for protection of cable complete including all plant & machinaries, alongwih Butt fusion welding machine with all accessories, T&P etc required complete all as specified and directed. Note :- Protection pipe will be measured and paid separately
Materials and labour for Earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected to GI earth lead 4 mm dia by means of GI bolts, nuts, check nuts, washers made out of GI/steel, all as shown on electrical plate No 3 of MES schedule part-I, earth lead wire connected to indicated position including upto 7.5m long 15 mm bore GI pipe for earth wire protection and concrete pit in PCC(1:3:6, C1),Precast RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe"medium grade" for watering with GI funnel and wire mesh including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil and testing on completion complete all as specified and as directed.
Supply and fixing electric water heater (Geyser) storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece complete all as specified and directed
S&F Bib taps fancy type cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, suitable for GI pipe of size 15 mm complete all as specified and directed
Supply and fixing PVC connection 15mm, 450mm long with chromium plated adopter and washer at both ends complete all as specified and directed (suitable for carrying hot water) complete all as specified and directed
Supply and fixing 25 mm bore, medium grade steel water tubing, galvanized, (ISI marked) with all fittings such as bends, elbows, tee, short pieces, diminishing pieces, cap and plugs laid in trenches, under floor, wall and as per site requirement incl taking out old unsv complete all as specified and as directed. (Earth work and necessary excavation shall be measured and paid for separately)
All as per serial item No. 216 here-in-before but of size 40mm bore –ditto-.
Supply and fixing Gun Metal gate valve with iron wheel head, suitable for 25 mm bore pipes, screwed both ends for iron pipe or for union including taking out old one complete all as specified and directed
Supply and fixing Gun Metal gate valve with iron wheel head, suitable for 40 mm bore pipes, screwed both ends for iron pipe or for union including taking out old one complete all as specified and directed
ms singh construction
M/s Singh enterprises
M/S R. K. INDUSTRIES
DNS CONSTRUCTION COMPANY
M/s Gupta Construction
M P KHAITAN
M/s NARAYAN MUKHERJEE & CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .