Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 CrQualified B 188 A ROAD NO 5 MEWAR INDUSTRIAL AREA MADRI UDAIPUR RAJASTHAN 313003 | UDAIPUR | RAJASTHAN | 313003 | ₹4.1 Cr | L1 | Qualified MII |
| 2 | L2₹4.9 Cr+₹77.7 L (18.9%)Qualified BANGALORE KARNATAKA 560002 | BENGALURU URBAN | KARNATAKA | 560002 | ₹4.9 Cr+₹77.7 L (18.9%) | L2 | Qualified MSE, MII, Category: General |
| 3 | L3₹5.3 Cr+₹1.2 Cr (28.6%)Qualified GB GROUND FLOOR HILL CROWN APARTMENTS COLLEGE ROAD MAPUSA NORTH GOA GOA 403507 | NORTH GOA | GOA | 403507 | ₹5.3 Cr+₹1.2 Cr (28.6%) | L3 | Qualified MSE, MII, Category: General |
Tender Value
Refer Docs
EMD Value
₹8.9 L
Closing Date
17 Jun 2026, 11:00 amClosed
Severe accident condition qualified RTDs
9197132
GEM/2026/B/7421068
Two Packet Bid
1. PT-100 strap on type RTD for 400 NB at KGS,2. PT-100 strap on type RTD for 400 NB at KAPS,3. PT-
Karnataka; Tapi, Gujarat; Bulandshahr, Uttar Pradesh; Chittorgarh, Rajasthan; Palghar, Maharashtra; Chengalpattu
Total value wise evaluation
BOQ
1 document required · 1 mandatory
Site Director, Kaiga Karnataka, Department of Atomic Energy, NUCLEAR POWER CORPORATION OF INDIA LIMITED, PMO, (Kaiga Nuclear Power Corporation)
₹8.9 L
17 Jun 2026
27 May 2026
17 Jun 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) | Spec |
|---|---|---|---|---|---|---|---|
| 1 | 1. PT-100 strap on type RTD for 400 NB at KGS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 400 NB line, OD 406.4 mm to be supplied at KGS. ( 18 nos for KGS 1 and 2 and 18 nos for KGS 3 and 4) | 36 | NOS | Santosh Kulkarni 581400,Plant Site, Kaiga Generating Station, PO:Kaiga | 365 | |
| 2 | 2. PT-100 strap on type RTD for 400 NB at KAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 400 NB line, OD 406.4 mm to be supplied at KAPS ( KAPS 1 and 2 ) | 18 | NOS | Trivedi Jayshreeben Ranchhodlal 394651,C&MM, KAPS PLANT SITE, P.O-ANUMALA, DISTRICT TAPI, SURAT | 365 | |
| 3 | 3. PT-100 strap on type RTD for 400 NB at NAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 400 NB line, OD 406.4 mm to be supplied at NAPS | 18 | NOS | Ishan 202389,C&MM, NARORA ATOMIC POW ER STATION, P.O- NAPS TOW NSHIP, NARORA, DISTRICT BULANDSHAHR, U.P | 365 | |
| 4 | 4. PT-100 strap on type RTD for 400 NB at RAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 400 NB line, OD 406.4 mm to be supplied at RAPS (18 nos for RAPS 3 and 4 and 18 nos for RAPS 5 and 6) | 36 | NOS | Gyan Mal Khatik 323303,C&MM, RAW ATBHATA RAJASTHAN SITE, NPCIL, P.O ANUSHAKTI, VIA-KOTA | 365 | |
| 5 | 5. PT-100 strap on type RTD for 500 NB at TAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 500 NB line, OD 508 mm to be supplied at TAPS (TAPS 3 and 4) | 10 | NOS | Sunny Ganesh Gupta 401504,C&MM, TARAPUR MAHARASHTRA SITE, DISTRICT- PALGHAR | 365 | |
| 6 | 6. PT-100 strap on type RTD for 600 NB at TAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 600 NB line, OD 610 mm to be supplied at TAPS (TAPS 3 and 4) | 10 | NOS | Sunny Ganesh Gupta 401504,C&MM, TARAPUR MAHARASHTRA SITE, DISTRICT- PALGHAR | 365 | |
| 7 | 7. PT-100 strap on type RTD for 300 NB at RAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 300 NB line, OD 323.84mm to be supplied at RAPS (RAPS 1 and 2) | 9 | NOS | Gyan Mal Khatik 323303,C&MM, RAW ATBHATA RAJASTHAN SITE, NPCIL, P.O ANUSHAKTI, VIA-KOTA | 365 | |
| 8 | 8. PT-100 strap on type RTD for 300 NB at MAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 300 NB line, OD 323.84mm to be supplied at MAPS | 18 | NOS | Senthil Kumar 603102,C&MM, MADRAS ATOMIC POW ER STATION, P.O- KALPAKKAM, DISTRICT- KANCHEEPURAM, TAMILNADU | 365 | |
| 9 | 9. Test strap on type RTD for 600 NB at TAPS | Test strap on type RTD with 6 meter MI cable and 4 meter extension cable for 600 NB line, OD 610 mm for carrying out the type tests and to be supplied at TAPS (TAPS 3 and 4) | 1 | NOS | Sunny Ganesh Gupta 401504,C&MM, TARAPUR MAHARASHTRA SITE, DISTRICT- PALGHAR | 365 | |
| 10 | 10. Pt 100 simplex area temperature RTD at KGS | Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at KGS ( 14 nos for KGS 1 and 2, 14 nos for KGS 3 and 4 ) | 28 | NOS | Santosh Kulkarni 581400,Plant Site, Kaiga Generating Station, PO:Kaiga | 365 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_9197132.pdf
GEM_BID • 0.20 MB
65176boqspec_2026-04-07-15-14-58_14f2fb890f67d3f07dd1eb3dcb8a00ff.pdf
BOQ • 2.33 MB
65176boq_2026-04-07-15-14-58_f42ae4f46459f715a182368471e9a8e2.csv
BOQ • 0.00 MB
1775711998.xlsx
GEM_OTHER • 0.02 MB
An_more_5_9d0460c0-4d9c-42b3-80081775555775139_sm_cmm_kgs.pdf
GEM_OTHER • 1.71 MB
gtc.pdf
GEM_OTHER • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .