Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 299 300 GIDC MAKARPURA VADODARA 390010 GIDC MAKARPURA VADODARA 390010 VADODARA VADODARA GUJARAT 390010 | VADODARA | GUJARAT | 390010 | Admitted-Finance |
| 2 | Admitted-Finance 528 529 PHASE 5 UDYOG VIHAR GURGAON HARYANA 122008 | GURUGRAM | HARYANA | 122008 | Admitted-Finance |
| 3 | Admitted-Finance B 16 17 VIRWANI INDUSTRIAL ESTATE GOREGAON EAST WESTERN EXPRESS HIGHWAY GOREGAON EAST MUMBAI MAHARASHTRA 400063 | MUMBAI SUBURBAN | MAHARASHTRA | 400063 | Admitted-Finance |
| 4 | Rejected-Technical E 29 A ROAD NO 2 INDRAPRASTHA INDUSTRIAL AREA KOTA 324005 RAJASTHAN INDIA | KOTA | KOTA | RAJASTHAN | 324005 | Rejected-Technical TECHNICALLY NOT ACCEPTABLE |
Tender Value
Refer Docs
Closing Date
30 Oct 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SEKAR HIRUDHAYAM
TECHNIP ENERGIES INDIA LTD, CHENNAI
SUPPLY OF BARRICADING AREA GAS DETECTION SYSTEM FOR NUMALIGARH REFINERY EXPANSION PROJECT
2023_NRL_769560_1
TP/082176C/NRL/PQ/103
Open Tender
Electrical Goods/Equipment
Supply
180 days
NUMALIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
ONLINE
20 Feb 2024
1 Sept 2023
31 Oct 2023
1 Sept 2023
30 Oct 2023
11 Oct 2023
12 Sept 2023
Open Path Gas Flammable gas detector receiver and transmitter(15m-35m) with mounting arrangement (Ubolt, clamps etc.) on 4inch pole
Open Path Gas Flammable gas detector receiver and transmitter(35m-120m) with mounting arrangement (Ubolt, clamps etc.) on 4inch pole
Gas detector Alignment kit
Hooter with Beacon (Hooter: Electronic type, atleast 110dB, Flashing lamp: Green/Yellow, Metallic enclosure along with all mounting accessories and support
Flashing beacon (LED type, High intensity (5W or above), Metallic enclosure, Red, along with all mounting accessories and support
Junction Box (Engineered and wired) with power on/off switch (externally mounted on JB for operating from outside), Power status indication lamp (flush mounted on the JB for viewing from outside), Entry provision for 2 Nos. of power cables (for looping with adjacent detectors) and 2 Nos. of signal cables (for multidrop fashion of HART Link), enclosed with the items (i.e. Microcontroller based Controller Modules with accessories, other items etc. as required/ applicable for LDU application). Junction Box shall also include Accessories (Cable gland, mounting accessories etc.) including supply of main items (Engineered JB/Panel) & accessories/consumables (Cable Glands, mounting accessories, cable ferrule, cable lugs etc.) and associated services (Both Supply and associated services).
Power and Earthing system inside the Junction box (PDB (Fitted with MCBs and accessories), Power Module (AC to DC), Power cables (inside panel), duct etc.), Earthing system with accessories (Including earthing cables, GI earthing strip (35 Mtrs., For hooking up with NRL's existing common earthing system), Surge protectors (for incoming power etc.) enclosed/ connected in the above JB)
Cable tray 50mm x 50mm (along with mounting accessories (jointing plate, Nut/bolts etc.) for running power cable and signal cable with supports for running tray including 10% spare
Cable tray 100mmx50mm (along with mounting accessories (jointing plate, Nut/bolts etc.) for Power cable
Signal Cable to daisy chain HART signal of Open path flammable gas detectors (apart from cables listed in Specification for Barricading area Gas detection system (TP-1ZZZA-IC-SPE-0011)
Secondary cable between Open path gas detector to LDU, between LDU to Hotter with beacon and between LDU to Healthiness flashing beacon
Power cables (2.5mm2, 2 cores, armored, overall shield) for entire bidder supplied items(LDU, porta cabins, field instruments etc.)
4inch Pole MOC: Hot dipped galvanized sch 40, ((2m each with end cap) along with mounting baseplate, erection accessories (Nut/ bolts etc.) for JB / LDU (LOCAL DETECTION UNIT) / Hooter & beacon etc.
PVC sleeve for entry to Each construction office
Cable road crossing arrangement: (Supply of CS Pipe (4" or above) including the supply of consumables required for fabrication jobs as per Tender Document)
Fully wired Barricading gas detection network cabinet (42U) with enclosed and engineered rack with Power Distribution System, perforated for proper air ventilation, multiple wired power sockets, internal mounting accessories along with necessary Power supply units, MCBs, isolators barriers, relays, TBs, Fan, LED light, Fan Failure relay, other cabinet diagnostic alarms etc., network switches with FO uplink, LIU, Redundant Power modules(As required), system cables and all maintenance tools and tackles.
Fully wired Barricading gas detection network cabinet (24U) with enclosed and engineered rack with Power Distribution System, perforated for proper air ventilation, multiple wired power sockets, internal mounting accessories along with necessary Power supply units, MCBs, isolators barriers, relays, TBs, Fan, LED light, Fan Failure relay, other cabinet diagnostic alarms etc., Converters/ Interface devices for the HART link between field devices and the PC, Redundant Power modules(As required), system cables and all maintenance tools and tackles.
Monitoring station (All in One, Intel Core i5 processor, 8 GB RAM, 250 GB Storage, LED screen (HD) (21 Inch (Diagonal or above), Accessories (Keyboard, Mouse, OS, drivers, cables etc.) along with Anti-virus software, Windows 10 or latest
Barricading Gas detection system Application software installed in the Monitoring station (Monitoring, alarming, Data logging, Configuration, HMI)
External Audio speakers (USB powered) for hooking up with the PC for alarm purpose
Online UPS System with inbuilt battery (Atleast:500VA, 12V, Battery: 7AH) (, Note: This UPS will be installed inside the 24U Rack and will provide the entire active item inside the rack and the PC)
Fully wired Field UPS(1KVA) and cabinet (with inbuilt battery, IP 65 or above, MOV: Steel sheet, openable door, painted and finished product) mounted on field for powering the detectors, Hooters, Beacons and LDUs
Portable LEL detector (Supply of Detector (Hardware), accessories and associated services (Configuration, testing etc.)
Portable Multi-gas detector (Supply of Detector (Hardware), accessories and associated services (Configuration, testing etc.)
Field HART communicator (Supply of hardware and associated accessories etc.)
Mandatory spare (Detectors (5% of total Supply) + LDU (Internal electronics, Power supply etc.) (5% of total Supply)+Beacon cum hooter(5% of total supply),Flashing Beacon (5% of total supply)+UPS (Complete Unit)+Others (as per bidder's assessment)
Spare_1 (Spare Parts and Consumables for Installation, Precommissioning, and Start-up )
Special Tools and Tackles
Service support during installation, calibration,configuration, commissioning and during job execution (atleast 45 days at site) (Multiple mobilization/demobilization) (As per MR TP-1ZZZA-IC-RFQ-0053_D2 (Sl No. 4.1.1) (Note: Atleast Engineers+ 2 technical Staff + assistants per day shall be deputed by the bidder for this activity).
Site Assistance during start-up, SAT etc. of Barricading Gas detection instruments and system (atleast for 30 days at site) (Note: Atleast Engineers+ 2 technical Staff + assistants per day shall be deputed by the bidder for this activity). (As per MR TP-1ZZZA-IC-RFQ-0053_D2 (Sl No. 4.1.2)
Training Services for owner personnel for all items (Barricading gas detection instruments and system, bought out item as per MR) at OEM works 3 Engineers for 5 Man days at Vendor’s works (As per MR TP-1ZZZA-IC-RFQ-0053_D2 (Sl No. 4.5)
Training Services for owner personnel for all items (Barricading gas detection instruments and system, bought out item as per MR) at Site 5 Engineers + 5 operators for 10 working day at Site (As per MR TP-1ZZZA-IC-RFQ-0053_D2 (Sl No. 4.6)
Post commissioning Operation & maintenance (Comprehensive) service as per MR. for 24 Months (As per MR TP-1ZZZA-IC-RFQ-0053_D2 (Sl No. 4.2)
Advanced Systek Pvt. Ltd.
Safe-Tronics Automation Pvt. Ltd.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .