Executive Engineer(E)
LIGHTING department Kolkata Municipal Corporation 28A, K.N.Sen Road Kolkata-700042
REPAIRING OF ELECTRICAL AND LIGHTING WORKS AT CITIZENS PARK IN WARD NO. - 68, UNDER BR. - VIII
2026_KMC_992125_1
KMC/LTG/Z-III/2025-2026/874
Open Tender
ELECTRICAL WORKS M/R
30 days
CITIZENS PARK
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹3,000
16 Feb 2026
21 Jan 2026
2 Feb 2026
21 Jan 2026
2 Feb 2026
21 Jan 2026
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of(approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. FOR receiving fresh coat of paint.Upto 9.0 mtr. long pole.One coat of red lead/Zinc chromate priming
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of(approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. FOR receiving fresh coat of paint.Upto 9.0 mtr. long pole.1st coat of synthetic enamel paint over the primer
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of(approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. FOR receiving fresh coat of paint.Upto 9.0 mtr. long pole.2nd coat of synthetic enamel paint over the 1st coat
SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing Installation ... with Pipe Electrode.Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(a)By ISI Medium GI pipe.
SUPPLY OF PHILIPS MAKE 12 W LED LEAMP B22/E27, 1200 LM (IRRIGATION & WATERWAYS DEPARTMENT MECHANICAL & ELECTRICAL DIRECTORATE GOVT. OF WEST BENGAL, PAGE NO. - 5.3F.26.1)
Outdoor Lighting Installation, Steel Tubular Pole/ M.S Pipe/ G.I. Pipe, Pole CAP etc.Erection of single steel tublar pole up to 9m including ms sole plate (23m dia * 6 m thick) cap etc over flyover bridge etc with c.c foundation (4:3:1) WITH GRADED STONE CHIP (3/4'' DOWN) SURROUNDING THE POLE BASE 2*2 UP TO A HEIGHT OF 1.35M (4.1/2'') FROM THE POLE BASE WITH 2 COATS OF BLACK PAINT AND THEN FIXING THE POLE BASE WITH 2 COATS OF BLACK PAINT AND THEN FIXING THE POLE BY MEANS OF 3 NOS 4*1.1/2'' *1/4'' CLAMPS TO THE FENCING OF THE BRIDGE AT A SUITABLE DISTANCE AND PROVIDING THE PASSAGE OF WIRE/CABLE LEADING THROUGH HARD POLYTHENE PIPE (1.1/2'') AND ALSO EBONITE SHEET 4-WAY EBONITE TERMINAL CONNECTOR BLOCK INCLUDING CONNECTION WITH LUG BY CRIMPING ARRANGEMENT AND ALSO NEAT CEMENTING OF POLE BASE AND FINISHING WITHOUT LOOPBOX.
SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 14. Dismantling steel tubular/Rail/Strut embedded in CC foundation incl. excavation, filling of holes, restoring surface,loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km
Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/):Size in Sq. mm, No & dia. of wire in mm , No of Core - 6 1/2.80 2
Laying through Underground Trech.(a)Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying through RCC/Hume/GI Pipe.(a)Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench FOR single, 2, 3, 3... & 4 core
Supplying and Erection of additional foundation having Dimension of 600 * 600 * 600 mm C.C foundation (6:3:1) with graded stone chips (3/4" down) providing R.B. Net of 2" * 4" in size including neat cementing.
Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required
SUPPLY & DELIVERY OF TRIDENT LIGHT FITTING (POST TOP LANTERN) COMPLETE WITHOUT LAMP
Sub Total
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.04 MB
FORM.pdf
Tender Documents • 0.89 MB
BOQ_2425910.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid