Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 LAccepted-AOC 136 P NEW PROJECT ROAD NANDA NAGAR KUNRAGHAT GORAKHPUR UP PIN 273008 | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹41.6 L+₹1.3 L (3.14%)Rejected-Finance 32 06 PEST HOUSE NARONA CHAURAHA MALL ROAD POST BOX NO 49 KANPUR 208001 UP | KANPUR | KANPUR | UP | 208001 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹41.6 L+₹1.3 L (3.17%)Rejected-Finance | L3 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | MITHILA BUILDERS AND ENGINEERS L2 | H AND Y GROUP L1 | BINA ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.00 | Lump sum price worked out by the contractor as per showm on drawing for BUILDING WORKS as listed in Sch ‘A’ Part I. | 1 | LUMP SUM | 34,45,000 ₹34,45,000 | 33,50,000 ₹33,50,000 Lowest | 34,50,000 ₹34,50,000 |
| 2.00 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Sch 'A' Part II. | 1 | LUMP SUM | 2,376.42 ₹2,376.42 | 1,900 ₹1,900 Lowest | 3,199.03 ₹3,199.03 |
| 3.00 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION as listed in Sch 'A' Part III. | 1 | LUMP SUM | 1,38,920.54 ₹1,38,920.54 | 1,28,000 ₹1,28,000 Lowest | 1,34,895.04 ₹1,34,895.04 |
| 4.00 | Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Sch 'A' Part IV. | 1 | LUMP SUM | 65,199.45 ₹65,199.45 | 55,000 ₹55,000 Lowest | 65,144.45 ₹65,144.45 |
| 5.00 | Lump sum price worked out by the contractor for PCC PATH as listed in Sch 'A' Part V. | 1 | LUMP SUM | 49,955.06 ₹49,955.06 | 48,000 ₹48,000 Lowest | 55,610.35 ₹55,610.35 |
| 6.00 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIC SUPPLY as listed in Sch 'A' Part VI. | 1 | LUMP SUM | 1,97,767.1 ₹1,97,767.1 | 1,85,000 ₹1,85,000 Lowest | 2,40,277.79 ₹2,40,277.79 |
| 7.00 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Sch 'A' Part VII. | 1 | LUMP SUM | 22,235.6 ₹22,235.6 | 18,000 ₹18,000 Lowest | 26,326.95 ₹26,326.95 |
| 8.00 | Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTHWORK as listed in Sch 'A' Part VIII. | 1 | LUMP SUM | 99,601.38 ₹99,601.38 | 82,000 ₹82,000 | 73,476.43 ₹73,476.43 Lowest |
| 9.00Price item wise worked out by the Contractor for Schedule `A' Part-IX (rate against Srl No. 10.00 shall be quoted by the Contractor) | ||||||
| 10.00 | Bringing earth from out side MoD land n exc. 30 KM, spreading in layers n. Exc. 25 cm thick including watering, spreading, leveling, well ramming and rolling with 8 to 10 tonne power roller complete all as specified and directed. | 75.64 | Cum | 450 ₹34,038 | 300 ₹22,692 Lowest | 500 ₹37,820 |
Tender Value
₹40.2 L
EMD Value
₹80,420
Closing Date
9 Jan 2026, 6:00 pmClosed
CWE (AF) BAMRAULI
HQ CWE (AF) BAMRAULI, PRAYAGRAJ-211012
CONSTRUCTION OF ONE LAB IN PM SHRI KENDRIYA VIDYALAYA AT AF STN DARBHANGA
2025_MES_731572_2
87547/E8
Open Tender
Civil Works
Lump-sum
273 days
DARBHANGA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) BIHTA
₹80,420
Yes
23 Apr 2026
19 Dec 2025
16 Jan 2026
19 Dec 2025
9 Jan 2026
2 Jan 2026
19 Dec 2025 - 26 Dec 2025
Lump sum price worked out by the contractor as per showm on drawing for BUILDING WORKS as listed in Sch ‘A’ Part I.
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Sch 'A' Part II.
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION as listed in Sch 'A' Part III.
Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Sch 'A' Part IV.
Lump sum price worked out by the contractor for PCC PATH as listed in Sch 'A' Part V.
Lump sum price worked out by the contractor for EXTERNAL ELECTRIC SUPPLY as listed in Sch 'A' Part VI.
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Sch 'A' Part VII.
Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTHWORK as listed in Sch 'A' Part VIII.
Price item wise worked out by the Contractor for Schedule `A' Part-IX (rate against Srl No. 10.00 shall be quoted by the Contractor)
Bringing earth from out side MoD land n exc. 30 KM, spreading in layers n. Exc. 25 cm thick including watering, spreading, leveling, well ramming and rolling with 8 to 10 tonne power roller complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level (with top edge of the plate not less than 1.5 meters below normal ground level) connected to galvanized iron strip 25x4mm as earth lead by means of bolts, nuts, and washers all as shown in Plate No. 5 of SSR Part I of 2009 and connected to earthing test point & to main switch board with and including adequate qauntiy of charcoal dust & common salt in alternate layer around earth plate, 40mm dia pipe light grade for earth lead protection pipe, GI funnel with 20 mm dia medium grade GI pipe for watering and wire mesh including excavation and earth work, PCC pit with 1:3:6 Type C1 (Using 20 mm graded stone aggregate) RCC cover 300 x 300 x 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia plastering 15 mm thick in CM 1:6 externally upto 150 mm below ground level, and disposal of surplus soil complete including testing and writing test results on a 3.0 mm thick painted MS earth pit marking plate (200 mm x 100 mm) duly welded with a 450 mm long 10mm dia round MS rod fixed with the earth pit chamber by grouting complete including taking out old unserviceable earthing system including demolishing with old earth pit chambers and removing of debris from the site complete all as specified and directed. Note: - Earth lead wire and its protection pipe upto and including 15 meter only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid separately.
-do- all as above item No 11.00 but galvanised earth lead wire 4mm and 20 mm dia light grade GI earht lead protection pipe complet -ditto-
Supply, installation and commissioning CPRI approved factory fabricated, outdoor type, LT distribution panel box made out of 3.15 mm thick CRCA sheet with projected globe roof for rain water protection, dust and vermin proof, fouble door, both side opening, including neoprene rubber gasket, suitable for 440 Volt, 3 Phae, 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side. Bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeded with 50x50x6mm mild steel angle iron frame and 600mm above the normal ground level complete with internal connection with suitable size of cables glands PCC foundation in cement conrete 1:3:6 (20mm graded stoen aggregate) and testing after installation complete all as specified and directed and comprising of the following: -
S&F flood light bracket made out of GI tubing, light grade, 40mm bore 1200 mm long bent to shape at 120 degree, fixed on pole/building by providing MS clamp made out of flat iron 50x6 mm including bolts, nuts and washer of suitable size complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
87547TENDER2NDCALLl.rar
Tender Documents • 2.90 MB
BOQ_834489.xls
BOQ • 0.66 MB
87547DRG2NDCALL.rar
Additional Documents • 14.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .