Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC | ₹18.0 L | L1 | Accepted-AOC 1st lowest |
| 2 | L2₹18.3 L+₹31,185.20 (1.74%)Rejected-Finance | ₹18.3 L+₹31,185.20 (1.74%) | L2 | Rejected-Finance Being not a lowest |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
5 Nov 2021, 6:00 pmClosed
GE (WEST) PATHANKOT
GE (WEST) PATHANKOT
ROOF TREATMENT AND ALLIED WORKS TO CERTAIN BLDGS OF MD OTM ACCN UNDER AGE BR-I OF GE (WEST) PATHANKOT
2021_MES_480488_1
GE/PKT-54/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (WEST) PATHANKOT
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE (WEST) PATHANKOT
₹44,000
Yes
16 Dec 2021
8 Oct 2021
8 Nov 2021
8 Oct 2021
5 Nov 2021
23 Oct 2021
9 Oct 2021 - 16 Oct 2021
Amount
Taking up or down 15mm bore, steel tubing and connection complete all as specified and directed.
All as per ser item No 01 here-in-before but 20 mm bore.
S & F of 15mm bore Steel water tubing, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
All as per ser item no 03 here-in-before but 20 mm bore.
M&L for Refixing 15mm bore old steel tubing after cleaning and connections with all new GI fittings etc in new or old position (Walls, ceiling, floors, etc) complete all as specified and directed
All as per ser item no 05 here-in-before but 20 mm bore.
M&L for Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed
S & F in repair for PE AL PE composite fitting such as bend, female elbow, 1620x15 mm,1216x15mm,2520x 15mm complete all as specified and directed ake : Jindal/Vectus / Kitec/Nexgen Composite Industries/KPT Pipes/equivalent (as sample kept in GE's office)
All as per ser item no 08 here-in-before but 20 mm bore.
S & F in repair for PE AL PE composite fitting equal tee of size 2532x2532x2532x15 mm, 25 32 x 1216 x 2532x15 mm, 2532x1216x1216x15 mm complete all as specified and directed Make : Jindal/Vectus / Kitec/Nexgen Composite Industries/KPT Pipes/equivalent (as sample kept in GE's office)
All as per ser item no 10 here-in-before but 20 mm bore.
S&F in repair for PE AL PE composite fitting union of size 1620x1216 x15 mm ,2532x1620 x15 mm ,2532x2532 x15 mm complete all as specified and directed. Make : Jindal/Vectus / Kitec/Nexgen Composite Industries/KPT Pipes/equivalent (as sample kept in GE's office)
All as per ser item no 12 here-in-before but 20 mm bore.
S&F in repair for PE AL PE composite fitting union of size 2532x2532 x15 mm ,2532x1216 x15 mm,2532x1620 x15 mm,1620x1216 x15 mm complete all as specified and directed. Make : Jindal/Vectus / Kitec/Nexgen Composite Industries/KPT Pipes/equivalent (as sample kept in GE's office)
All as per ser item no 14 here-in-before but 20 mm bore.
S&F in repair for PEALPE Pipe 15 MM bore confirming to IS Code 15450 of size 1216. complete all as specified and directed. Make : Jindal/Vectus / Kitec/Nexgen Composite Industries/KPT Pipes/equivalent (as sample kept in GE's office)
All as per ser item no 16 here-in-before but 20 mm bore.
S&F in repair for PEALPE Pipe 15MM bore confirming to IS Code 15450 of size 1620 .complete all as specified and directed Make : Jindal/Vectus / Kitec/Nexgen Composite Industries/KPT Pipes/equivalent (as sample kept in GE's office)
All as per ser item no 18 here-in-before but 20 mm bore.
S & F of Rotational moulded polyethylene water storage tanks of 500 ltrs capacity ISI marked triple layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including Ball valves high pressure of PTMT with epoxy coated aluminum rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including dismantling of old Broken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed.
All as per item no 20 here-in-before but water storage tanks of 1000 ltrs capacity ISI marked triple layered
S & F in repair for Vitreous China wash down water closet pan including P or S trap (pedestal pattern), white or in matching colour of tiles (excluding flushing cistern and flush pipe) including plastic water closet seat, white or in matching colour , closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinging device and wash down water closet complete all as specified and as directed.
S & F in repair for vitreous China squatting pan, ‘Orissa’pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) squatting pan including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good as per existing specification to floor complete all as specified and directed.
S & F in repair for PVC valveless, syphonic action type, flushing cistern,low level, white, with inlet,ball valve, float and handle including brackets including flush pipe of polyethylene of low or high density or PVC. 32 mm dia for low level cistern complete all as specified and as directed.
S & F in repair Ball valves 20mm bore high pressure of PTMT with epoxy coated aluminum rod & high-density plastic bal screwed for iron pipe & fixed. (min. weight 20mm-210 gms) complete all as specified and directed.
S & F in repair PVC tank lid/cover for water storage tank capacity of 250 to 2000 ltrs with fixing arrangement complete all as specified and directed.
S & F in repair for Plastic water closet seat, any coloure, closed pattern with recessed bottom, & cover & mild steel CP or aluminised hinging device complete all as specified and as directed.
S&F in repair for Brass chromium plated angular stop cock with wall flange screwed for 15mm dia bore iron pipe complete all as specified and directed Make:Jaquar CAT NO -CON-059KN1 or equivalent in any of the make mentioned in list of product.
S&F in repair for 15mm bore Stop valves, fancy type, chromium plated with long shank and cup (concealed type),cast copper alloy, screwed down, high pressure, with crutch or above butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed
S&F in repair for 15mm bore Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed for wash basin,wall (bathroom) & sink mixer complete all as specified and directed.
S&F in repair for 15 mm bore chromium plated fancy type Bib taps, cast copper alloy with crutch or above butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed (minimum weight 575 grams) complete all as specified and directed.
S&F in repair for swan neck fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed (minimum weight 665 grams) complete all as specified and directed.
S&F in repair for Brass CP shower rose 125mm size including fixing to steel pipe or union complete all as specified and directed.
S&F in repair for chromium plated Hand shower (Health faucet) with 8mm Dia, 1.2 Meter long flexible tube and wall hook with N.R.V (Back Flow Preventer) complete all as specified and directed Make : Jaquar Health Faucet ALD 577 or equivalent in any of the make mentioned in list of products.
S & F in repair for 32mmbore PVC waste pipe flexible type including all cups and sockets with minimum length 800mm for stainless steel sinks, basins, urinal etc complete all as specified and directed.
All as per ser item no 35 here-in-before but 40mm bore PVC waste pipe
S & F in repair Low density polyethylene bore of pipe 32 mm (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and as directed
All as per ser item no 37 here-in-before but 40mm bore LDPE
S & F in repair for 15mm dia PVC connections 600mm long with PTMT nuts complete all as specified and as directed.
S & F in repair for 125mm dia chromium plated perforated grating with hole/without hole for waste pipe fixed over floor/nahani trap complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar,internal dia of pipe in 75/100mm complete all as specified and directed.
S&F of PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as spd and directed.
All as per ser item no 42 here-in-before but 110mm bore
Taking down eaves gutter and rain water pipe any size any pattern , PVC/ AC pipe including all fittings ,heads shoes, bends etc Internal dia of pipe 75/110mm complete all as specified and directed.
S&F of PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
All as per ser item no 45 here-in-before but 110mm bore
S&F of PVC (SWR) bends ISI marked any radius 75mm dia complete all as specified and directed.
S&F of PVC (SWR) bends ISI marked any radius 110mm dia complete all as specified and directed.
S & F in repair for 75mm size PVC floor trap, ISI marked with perforated grating incl jointing to waste pipe fixed with solvent cement complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required Internal dia of pipe 75mm/100mm complete all as specified and as directed.
S &F of spun Cast iron soil, waste and vent pipes ISI marked, in any length with or without ears with cement joints, laid in trenches or in floors bore of pipe 75mm complete all as specified and directed.
All as per ser item no 51 here-in-before but 100mm bore
S &F of spun Cast iron soil, waste and vent pipes ISI marked, in any length with or without ears with cement joints, fixed to walls bore of pipe 75mm complete all as specified and directed.
All as per ser item no 53 here-in-before but 100mm bore
M & L for spun Cast iron bends (ISI marked) (any radius) diminishing pieces or tapers (larger bore measured), bore of pipe 75mm, complete all as specified and directed.
All as per ser item no 55 here-in-before but 100mm bore
M & L Cast iron floor trap75mm bore , with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified.
S & F in repair 20mm bore Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
All as per ser item no 58 here-in-before but 15mm bore
M&L for Cleaning and removing all scale and dirt etc from PVC/RCC tanks and from mouths of circulating pipes etc of capacity of tank exc 250 ltrs upto and including 500 ltrs including dismantling and refixing if required at site complete all as specified and directed
All as per ser item no 60 here-in-before but capacity of tank exc 500 not exe 1000 ltrs
Demolition of existing roof treatment of any description such as wornout tarfelt, mortar of any description & any thickness, shurves vegetation, tree, terracing pcc/brick tiles, concrete bedding etc as directed and Cleaning of all foreign material debris etc by brushing and dusting, washing down with water etc ,surface shall be leveled with a layer of 20 mm thick screed bed in CM 1:4 including mixed with water proofing admixture as per manufacturer's instructions and applying roof treatment with 03mm thick APP modified membrane with non-woven polyster reinforcement(center core) with thermal insulation with white mineral gravel finish on upper side of weight not less than 3.5 kg/sqm , laid by torch application method with overlap 100 mm on length side and 100 mm on the width side as per manufacturer's instructions over one coat of approved cold applied bituminous oil based primer (IS-3384) @0.30 litre/sqm complete all as specified and directed (Note:- WPC shall be measured and paid separately)
Supply only liquid water proofing compound all as specified and as directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof covering from sunshades etc complete all as specified and directed.
S & F of Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
All as per ser item no 65 here-in-before but except sheets. Note :- Serviceable quantity obtained from dismantling shall be reused under this item.
S & F of Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for cutting grooves in stone/brick/concrete wall by mechanical cutter only wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
Dismantling of AC/fibre glass reinforced translucent corrugated or semi corrugated,plain sheeting in roof including ridges,sunshades,chajjas etc complete all as specified and directed.
S & F of fibre glass reinforced translucent plain/corrugated sheeting 2mm thick with two corrugations side lap fixed with L type or J type cranked hook bolts or coach screw & washer complete all as specified and directed.
All as per ser item no 70 here-in-before but plain sheets.
M&L for for 6 mm thick fibre cement corrugated or semi-corrugated sheet in roofs fixed with ‘L’ type or ‘J’ type or cranked hook bolts, complete all as specified and directed.
All as per ser item no 72 here-in-before but except sheets. Note :- Serviceable quantity obtained from dismantling shall be reused under this item.
M&L for 6mm thick fiber cement two piece adjustable serrated ridge suitable for corrugated or semi corrugated sheets in roofs fixed with ‘L’ type or ‘J’ type or cranked hook bolts, complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for including grills, door, truss, gate, rafters, purlins etc complete all as specified and directed.
S &F for rolled sections hollow section as in main and cross beams, hip and jack rafters; purlins where connected to a common rafters and rails and guides for sliding doors; and supports to roof covering, sun-shades etc fixed with angle cleats or other connecting plates Fe-410-W(Gde-E-250) quality B complete all as specified and directed.
All as per ser item no 76 here-in-before but Erection fixing only NOTE: Old Serviceable mild steel section of any thickness/type retrieved from dismantling shall be re-used.
S &F for Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
S & F for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;l adders; framed balusters; walk ways; railings; framework of water tanks, wind ties,cattle trap and similar work conforming to Fe.290.Gde-E-165,ornamental and intricate design complete all as specified and directed.
Dismantling timber scantlings 40sqcm and over in section, in any position as in wooden trusses in framed work of any description complete all as specified and directed.
M&L for 2nd class hard wood in scantling clean sawn timber work of suitable size of any shape fixed with screws or nails including preparation of surfaces & applying two coats of synthetic enamel paint over and including a coat of pink primer complete all as specified and directed
Rooting out plants / trees , flora & fauna and foliage as grown on roof/wall surfaces area not exc 0.36 Sqm each by cutting hole into slabs/walls for digging out roots and using chemical to burn deep rooted tree roots etc and making good disturb portion of wall/roof surface with cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate complete all as specified and directed.
Taking down cement plaster of any description and thickness on walls/ceilings etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M &L for two coat plaster 35 mm thick (20 mm + 15 mm) on fair faces or other than fair faces, rough surface of brick/stone/concrete masonry surface of wall, fin, facia, chajjas, parapet and similar article in cm 1:3 with liquid water proofing compound (as per manufacturer’s instructions) mixed in both coats, finished even and smooth without using extra cement complete all as specified and as directed.(Note:- WPC shall be measured and paid separately) Note :- Two coat plaster shall be carried out as mentioned in clause 14.18 of SSR-2009, Part-I complete.
M & L for rendering 15mm thick in CM 1:4 mixed with liquid water proofing compound (as per manufacturer’s instructions) on fair faces of brick work ,concrete surface of wall, fin, facia, chajjas, parapet and similar article finished surface even and smooth without using extra cement complete all as specified and as directed. (Note:- WPC shall be measured and paid separately)
All as per ser item no 85 here-in-before but on other than fair faces
M&L for 10 mm thick rendering on brick work or concrete surfaces in CM 1:3 mixed with liquid water proofing compound as in ceiling of roof slab ,fin, facia, culvert, chajjas, parapet and similar article etc finishing surfaces even and smooth without using extra cement complete all as specified and as directed. (Note:- WPC shall be measured and paid separately)
M & L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M & L for preparation of newly plastered surfaces of wall and applying two coats of weather proof exterior emulsion paint over and including one coat of primer (as per manufacturer’s recommendations) complete all as specified and as directed.
All as per ser item no 89 here-in-before but applying two coats of Cement Base Paint in any tint over and including one coat of alkali resistant primer (as per manufacturer’s recommendations) complete all as specified and directed.
All as per ser item no 89 above but applying minimum 02mm thick white cement based wall care putty on wall surfaces & making smooth surface and applying two coat of distemper oil emulsion in any tint complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar or cement lime mortar including all quions, wall, arches, pillars, man-holes, drain etc complete all as specified and directed.
M & L for burnt clay brick work with sub-class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.
All as per ser item no 93 here-in-before but except bricks.Note: Old Serviceable bricks quantity retrieved from demolition shall be used.
Demolition of cement concrete or lime concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed .
M&L for PCC 1:2:4, type B-0, (using 12.5 mm graded crushed stone aggregate) mixed with water proofing compound as per manufacturer’s instructions as in padding on roof, surface finished even and smooth without using extra cement all as specified and as directed.(Note:- WPC shall be measured and paid separately)
M & L for PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in copings, kneelers, apex stones,bed plates, kerbs including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n. exc 15 cm thick (below or above ground level) and disposal of debris complete all as specified and directed.
M&L 40 mm thick PCC 1:2:4, type B-1 , (using 20 mm graded crushed stone aggregate) finished even and smooth without using extra cement as in flooring complete all as specified and directed.
Demolition of RCC of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M & L for for precast reinforcement cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in landings, cover slabs for drain & manholes etc chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar (1:4) complete all as specified and as directed.
M & L for Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and as directed.
M&L for joint free Non - skid Ceramic Coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in CM 1:4 including dismantling existing tiling with cement mortar bedding complete all as specified and directed.
M&L for Glazed ceramic Coloured tiles in vertical surface/dado of size 450mmx300mmx7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including 10mm thick rough cement plaster to receive tiles in CM 1:4 including dismantling existing tiling with cement mortar bedding complete all as specified and directed.
M &L for preparation of old plastered or unplastered ,old decorated surfaces of wall surface by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying applying two coats of Cement Base Paint over and including one coat of alkali resistant primer (as per manufacturer’s recommendations) complete all as specified and as directed.
All as per ser item no 106 here-in-before but applying minimum 02mm thick white cement based wall care putty on wall surfaces & making smooth surface and applying two coat of distemper oil emulsion in any tint
All as per ser item no 106 here-in-before but applying two coats of weather proof exterior emulsion Paint in any tint over and including one coat of primer (as per manufacturer’s recommendations) (external surface)
All as per ser item no 106 here-in-before but applying two coats of white wash on ceiling surface
All as per ser item no 106 here-in-before but applying two coats of white wash
M&L for preparation of newly steel and iron surface of any description width or girth exc 10 cm and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed.
M & L for preparation of old painted wooden surfaces of any description over 10 centimeter width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
All as per ser item no 112 here-in-before but on steel surfaces
Note: - Bidder quoted rate are deemed to be included for the following. Contractor to quote the rates accordingly. (a) Work against all items can be done in peace meal quantities as requirement raised by users and no objection whatsoever will be entertained in this regard. (b) Cleaning stains and dripping mortars from floors and walls etc. (c ) Use of all scaffolding, trestles, ladders, cradles, etc. Necessary for execution of work and protective measures. (d ) Removing of nails, making good holes, cracks, etc (e ) dust sheets spreading & removing coverings to joinery, floors, fixtures, fittings, furniture, etc to protect them from splashes. (f ) Removing and replacing furniture, movable cupboard, chicks, blinds, etc. (g ) Removing, Washing, cleaning all splashes, drops, dirt from floors, wire mess, builder hardware’s ,glass panes, doors, windows, wardrobes, cupboards, Kitchen cabinet, almirahs etc any type of fixtures & fittings of B/R & E/M Items, furniture, wiring etc and leaving premises in a clean & tidy state. Finally re-fixing blinds, curtains rod, fixtures, fittings etc (Note-Any damaged during work shall be replaced with new items without any extra cost to the govt. (h ) All straight, Raking, circular cutting & wastage etc of tiles & stone etc. (j ) Texture, colour, Shade, tint, make, laying to any pattern, design with one or more Texture, colour, Shade, tint, shall be approved by GE.
Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (Rs. 99,635.00). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 3% (Three percent) of the accepted contract sum shall be delivered by the successful bidder immediately after the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249
Ms Narinder Kumar Sehgal
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .