| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹12.9 L+₹2.5 L (23.8%)Rejected-AOC 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L2 | Rejected-AOC rejected |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
7 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
REPAIRS REPLACEMENT OF EXTERNAL SERVICES ELECTRIFICATION SUPPLY DISTRIBUTION SYTEMS AND CONNECTED ALLIED WORKS AT MEANEE LINE DEPOT BN TB 1 CIW CICE FMME TOC POC ASSAYE LINE OFFICER MESS 32 KEY PERSONNEL QTRS NEW TB III AND OLD TB III
2020_MES_394434_1
8488
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
BANGALORE
Class E Category b(i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹20,000
Yes
17 Dec 2020
11 Nov 2020
9 Dec 2020
11 Nov 2020
7 Dec 2020
25 Nov 2020
11 Nov 2020 - 24 Nov 2020
60 days
Amount
Excavation in trenches as in hard/dense soil not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for laying of cables/errection of pole etc., complete all as specified and as directed.
Excavation in trenches as in hard/dense soil not less than 1.5 mtr deep and not exc. 3 mtr in deep for pole foundation etc complete all as specified and as directed.
Returning, filling in excavated soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard / dense soil etc complete as specified as directed.
Removing the excavated material to a distance n.exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point.
Sand cushioning in layers for cables in trenches / ducts for cable including consolidation complete all as specified and directed. NOTE: Punned thickness will be measured for payment purpose.
Bricks, sub class 'B' of old size 230 mm x 115 mm x 75 mm laid in trenches for cable protection all as specified and directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 10 sq.mm, 2 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 10 sq.mm, 4 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 16 sq.mm, 2 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 16 sq.mm, 4 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 25 sq.mm, 3.5 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 35 sq.mm, 3.5 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 50 sq.mm, 3.5 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 70 sq.mm, 3.5 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 95 sq.mm, 3.5 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 120 sq.mm, 3.5 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
Rollled mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections of mild steel channel / angle iron / flat iron / round section of any size including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including dismantling the existing and inclusive of one red oxide primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and as directed
Pin type porcelain, vitreous white or brown insulator including one galvanized mild steel spindle, two galvanized iron washer and galvanized iron nut, size of insulator 100 mm height and 65mm dia suitable for 1100 volts grade supply including dismantling the existing complete all as specified and as directed.
Shackle type porcelain, vitreous white or brown insulator including one galvanized mild steel spindle, two galvanized iron washer and galvanized iron nut, size of insulator 75 mm height and 90mm dia suitable for 1100 volts grade supply including dismantling the existing complete all as specified and as directed.
Stay assembly complete with all accessories as shown in electrical plate No 1 of SSR Part-I consisting of stay rod 20mm dia, 1.80 mtr long stay plate 230 x 230 x 6 mm with nuts, bolts, insulator stay clamps etc.,complete all as shown on drawing and as directed. NOTE:-Excavation, stay wire, loop type insulator, stay clamps, excavation and concrete shall be measured separately.
Galvanized stay wire stranded 7/4 mm complete all as specified and as directed.
Loop type insulator, vitreous porcelain, white, brown or green with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as shown on drawing and as directed.
Galvinised iron tubing, light grade, 50mm bore with all accessories for cable protection fixed on poles/buildings or laid in trenches including necessary MS clamps, bolts and nuts etc., including taking down the existing complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr, connected to galvanized strip 25 x 4 mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No. 3 of SSR Part-I 2010 and as specified or indicated including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast RCC slab 40mm thick in Reinforced Cement Concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways including funnel with watering pipe wire mesh and lugs, including test point and testing on completion and taking down the existing unserviceable earthing complete all as specified and as directed.
MCCB, 25 to 100 Amps, 16 KA, four pole, 415 Volts, 50Hz with fixed thermal and magnetic setting with complete connections with incoming cable and out going cable with suitable thimbles, crimping the thimbles with crimping tools insulating the naked portion with insulation tape and including taking down the existing unserviceable MCCB complete all as specified and as directed.
MCCB, 200 Amps, 25 KA, four pole, 415 Volts, 50Hz with fixed thermal and magnetic setting with complete connections with incoming cable and out going cable with suitable thimbles, crimping the thimbles with crimping tools insulating the naked portion with insulation tape and including taking down the existing unserviceable MCCB complete all as specified and as directed.
MCCB, 250 Amps, 36 KA, four pole, 415 Volts, 50Hz with thermal and magnetic setting with complete connections with incoming cable and out going cable with suitable thimbles, crimping the thimbles with crimping tools insulating the naked portion with insulation tape and including taking down the existing unserviceable MCCB complete all as specified and as directed.
MCCB, 400 Amps, 36 KA, four pole, 415 Volts, 50Hz with adjustable type with thermal and magentic settig with complete connections with incoming cable and out going cable with suitable thimbles, crimping the thimbles with crimping tools insulating the naked portion with insulation tape and including taking down the existing unserviceable MCCB complete all as specified and as directed.
LT 2 line separator, 230 volts, 50 Hz including dismantling the existing complete all as specified as directed
LT 4 line separator, 415 volts, 50 Hz including dismantling the existing complete all as specified as directed
Cable jointing kit suitable for 1.1KV grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core / 4core XLPE armoured aluminium conductor cable including taking down the existing for following sizes:- (a) 3.5 core x 25 to 35 sq.mm.
(b) 3.5 core x 50 sq.mm.
(c) 3.5 core x 70 sq.mm.
(d) 3.5 core x 95 sq.mm.
(e) 3.5 core x 120 x 150 sq.mm.
Painting of steel tubular poles of any height and type, including security light mounting brackets with one coat of aluminium paint with painting black and white strip or as ordered by Engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering with writing letters or figures(Block), height not exc. 30 cm & letters or figures n.exc. 10 Nos complete all specified and as directed.
Painting of PCC poles of any height and type with two coat of cement based paint with painting black and white strip or as ordered by Engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering with writing letters or figures(Block), height not exc. 30 cm & letters or figures n.exc. 10 Nos complete all specified and as directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including provision of HDPE pipe of 150 mm dia bore suitable for 0.4 Mpa working pressure all as specified and as directed.
Dismantling of ACSR (Aluminium conductor steel reinforced) conductors of any type complete all as specified and as directed.
Brackets made out of GI tubing medium grade 40mm bore of 1.50 mtr length bent to required shape and pattern to mount the street light, including 2 Nos of MS clamps made out of MS flat iron 25 x 6mm, nuts, bolts, washers etc and applying two coats of alumium paint over a coat of red oxide primer complete all as specified and as directed.
ACSR (Aluminium conductor steel reinforced) conductor of any size on poles including binding wire of appropriate size complete including clearing of path and branch cutting of trees etc., all as specified and as directed
Refixing of existing ACSR conductors in between the poles, tightening, restringing the same in between poles / insulators and connected with new binding wire, tightening to insulator including line clearence by pruning of tree branch approx 1 mtr apart from conductor and tightening the sides complete all as specified and as directed.
Dismantling the damaged steel / concrete poles / struts any size complete all as specified and as directed.
Steel tubular poles complete with cast iron plate, finial tapper plug, bolts nuts & screws as per type 410 SP -31 ,9 mtr long complete all as specified and as directed.
Moulded (FRP) junction box with IP 65 protection of size 300x200x80mm with 32 Amp 4 way heavy duty terminal block with 6 Amp MCB SP and two number of cable entry gland of standard size with suitable MS bracket to fix with pole complete including taking down the existing all as specified and as directed.
LED street light fitting 60 watt, with pressure die cast housing along with prismatic polycarbonate modular secondary lens optics with IP 66 ingress protection and impact resistance of IK 08, 0.4 KV inbuilt and 10 KV external surge protection with top opening driver cover for easy maintenance .including taking down old unserviceable street light fittings from pole complete as per Bajaj Cat No. ENXT P 72 L WH CR PC SD or techno commercially equivalent makes specified in PS complete all as specified and as directed.
LED driver 90 watt suitable for existing unserviceable LED street light fittings of any type including dismanling and taking down old fitting from Pole, repacing the unserviceable driver and refixing the fittting in existing / new location all as specified and as directed.
LED driver 60 watt suitable for existing unserviceable LED street light fittings of any type including dismanling and taking down old fitting from Pole, repacing the unserviceable driver and refixing the fittting in existing / new location all as specified and as directed.
LED driver 40/45 watt suitable for existing unserviceable LED street light fittings of any type including dismanling and taking down old fitting from Pole, repacing the unserviceable driver and refixing the fittting in existing / new location all as specified and as directed.
LED driver 30/25 watt suitable for existing unserviceable LED street light fittings of any type including dismanling and taking down old fitting from Pole, repacing the unserviceable driver and refixing the fittting in existing / new location all as specified and as directed.
Plain Cement Concrete, (1:2:4), type C1, using 20mm graded stone aggregate, for coping of pole,filling and mass concrete of pole, make good to road surface , hard standing etc including necessary form work all as specified and as directed.
Plain Cement Concrete, (1:4:8), type D2, using 40mm graded stone aggregate, as in foundation of poles complete all as specified and as directed.
Repair to APFC panels by opening of the panel, disconnecting all electric supply, replacing of the damaged wiring, including rewiring and replacement of un serviceable parts complete all as specified and directed.
Power capacitor heavy duty can type, 440 Volts of 5 KVAR capacity including taking down existing complete all as specified and as directed.
Power capacitor heavy duty can type, 440 Volts of 12.5 KVAR capacity including taking down existing complete all as specified and as directed.
Power capacitor heavy duty can type, 440 Volts of 10 KVAR capacity including taking down existing complete all as specified and as directed.
Power capacitor heavy duty can type, 440 Volts of 20 KVAR capacity including taking down existing complete all as specified and as directed.
Power contactor three phase of 18 Amps with 2 NO + 2 NC integrated aux contacts, 3 phase including taking down the existing complete all as specified and as directed.
Power contactor three phase of 32 Amps with 2 NO + 2 NC integrated aux contacts, 3 phase including taking down the existing complete all as specified and as directed.
Power contactor three phase of 50 Amps with 2 NO + 2 NC integrated aux contacts, 3 phase including taking down the existing complete all as specified and as directed.
APFC unit for auto power factor correction digital type, 8/6 stage, 440 Volts including taking down the existing complete all as specified and as directed.
NO / NC contact /Add on block of various capacities complete all as specified and as directed .
CT 200A/5 including taking down the existing complete all as specified and as directed.
Ammeter range 0 - 200 Amps including taking down the existing complete all as specified and as directed.
Volt meter range 0 -500 Volts including taking down the existing complete all as specified and as directed.
Indicator lamp RYB/RRR-set of 03 -01 No including taking down the existing complete all as specified and as directed.
PVC insulated Sheahed copper cable of size 2 core 2.5 sq.mm all as specified and as directed.
LED post top of 40 Watts made in die-cast aluminium housing with decorative opal polycarbonate diffuser with IP-65 protection complete including PCC (1:2:4) as in foundation work all as per Bajaj Cat No. BGCL 40W LED WH or techno commercially equivalent makes specified in PS complete all as as specified and as directed.
LED lamps suitable for batten / pendent holder of luminous efficiency 90/100 lm /watt , CRI ≥ 80, power factor above 0.95 suitable for indoor and out door application of capacity 40 watt complete all as specified and as directed.
LED flood light liminaries of 150 watt made out of pressure die cast aluminum housing with toughened glass, high pressure LEDs and secondary lenses with IP-66 protection, 4 KV in built and 10 kV external surge protection etc complete all as per Bajaj Cat no.: BJFL 150 W LED / Crompton Cat no. LFLN-150CDL / 60M / Halonix Cat No. HLFLDML-15-150CWL-R all as specified and as directed.
Repairs to high mast light of any capacity and height by operating the control gear, repair / replacement of unserviceable flood lights, rising the flood lights to the original position, testing and commissioning etc complete all as specified and directed. NOTE:- (i) Flood lights replaced will be measured and paid separately. (ii) Tools and equipment's required for the repair of high mast lights shall be provided by the contractor and the cost of the same shall be included in the quoted rate.
Repairs to load change over switch of 100 Amps capacity three phase 415 volts, 50 Hz any make and type complete all as specified and directed.
Vasavi Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .