Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC 1ST FLOOR P R COMPLEX AT ROAD GUWAHATI 781 001 | KAMRUP METRO | ASSAM | 781001 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹32.9 L+₹2.3 L (7.42%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹34.1 L+₹3.5 L (11.3%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹35.1 L+₹4.5 L (14.6%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹35.3 L+₹4.6 L (15.1%)Rejected-Finance AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
24 Jul 2021, 6:00 pmClosed
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati-15, Assam, Pin- 781015 Tele 0361 - 2840127
REPAIR/MAINTENCE/PREVENTIVE MAITENANCE AND SERVICES OF DG SET AT AF STATION BORJHAR UNDER GE(AF) BORJHAR
2021_MES_459110_1
8220/BOR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (AF) Borjhar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹60,000
Yes
18 Aug 2021
12 Jul 2021
26 Jul 2021
12 Jul 2021
24 Jul 2021
19 Jul 2021
Amount
M & L for Maintenance and servicing of DG Sets of following capacity complete all as specified and as directed. NOTE: (a) One servicing of DG Set shall be measured & paid as "Each Job ".(b) Minor Spare parts like as rubber gasket , pins, seal, key lock & replace to old engine oil etc shall be replaced under servicing without any cost and major parts likes eingine oil filter,diesel oil filter, air filter & engine oil shall be measured & paid seprately under respective item of this schedule as supply only and fixing charge shall be deemed to be included in the unit rate of this of schedule'A'.
(a) DG Set of capacity 10/15 KVA (Kiloskar/CG/Mahindra)
(b) DG Set of capacity 25/30/40/45 KVA (Kiloskar/CG/Mahindra)
(c )DG Set of capacity 63/82.50 KVA (Kiloskar/CG/Mahindra)
(d) DG Set of capacity 100/125 KVA (Kiloskar/CG/Mahindra)
M & L for Maintenance and servicing of DG Sets of following capacity complete all as specified and as directed. NOTE: (a) Servicing of DG Set shall be done through OEM M/s KEOL or authorised dealer (as per MOU) for the complete DG set by servicing/replacing any type of spare parts as and when required. (b) Minor Spare parts like as rubber gasket, pins, seal, key lock & replace to old engine oil etc shall be replaced under servicing without any cost and major parts likes eingine oil filter,diesel oil filter, air filter & engine oil shall be measured & paid seprately under respective item of this schedule as supply only and fixing charge shall be deemed to be included in the unit rate of this of schedule'A'.
(a) DG Set of capacity 750 KVA ( Make: KOEL)
(d) DG Set of capacity 320 KVA (Make: KOEL)
Material & Labour only for repair and calibration of FIP of following DG Sets including replace to unserviceable plunger, washer manifold, injection nozzles etc. all as required and testing after repair work & setting to rated RPM and fixed on staging complete all as specified and as directed. NOTE: Spare parts shall be measured and paid as "Supply only " separately under respective items. (ii) Fixing charges shall be deemed to be included in the unit rate of this item .No thing extra shall be admissible on this account .
(a ) DG Set of capacity - 125 /100 KVA (Kiloskar/CG/Mahindra/Cummins)
(b ) DG Set of capacity – 63/82.50 KVA (Kiloskar/CG/Mahindra/Cummins))
(c ) DG Set of capacity – 45/35/30/25 KVA (Kiloskar/CG/Mahindra/Cummins))
(d) DG Set of capacity – 10/15 KVA(Kiloskar/CG/Mahindra)
Material & Labour for overhauling of injector including replace to unserviceable nozzles, washers, timing shaft with coupling etc. and setting of pressure as required for DG Sets of following capacities complete all as specified and as directed. NOTE: Spare parts shall be measured and paid as "Supply only " separately under respective items. (ii) Fixing charges shall be deemed to be included in the unit rate of this item .Nothing extra shall be admissible on this account .
(a) DG Set of capacity - 125 /100 KVA
(b) DG Set of capacity – 63/82.50 KVA
(c ) DG Set of capacity – 45/35/30/25 KVA
(d) DG Set of capacity – 10/15 KVA
Material & Labour for complete overhauling of self starter and replace to unserviceable carbon, armature coil, field coil, bush and bendex pinion and other related components to the following capacities DG sets NOTE: Spare parts shall be measured and paid as "Supply only " separately under respective items. (ii) Fixing charges shall be deemed to be included in the unit rate of this item . No-thing extra shall be admissible on this account .
(a) DG Set of capacity - 125 /100 KVA
(b) DG Set of capacity – 63/82.50 KVA
(c ) DG Set of capacity – 45/35/30/25 KVA
(d) DG Set of capacity – 10/15 KVA
(e) DG Set of capacity – 750 KVA
(f) DG Set of capacity – 320 KVA
Material & Labour only repair and overhauling of battery charging Alternator including replace to unserviceable armature coil, carbon set, field coil, clutch plate, bearing etc and other related items as required after repair work re-fixing the same on mountings and tested complete for following capacities DG sets. NOTE: Spare parts shall be measured and paid as "Supply only " separately under respective items. (ii) Fixing charges shall be deemed to be included in the unit rate of this item .No thing extra shall be admissible on this account .
(a) DG Set of capacity - 125 /100 KVA
(b) DG Set of capacity – 63/82.50 KVA
(c )DG Set of capacity – 45/35/30 KVA
(d) DG Set of capacity – 10/15 KVA
(e) DG Set of capacity – 750 KVA
(f) DG Set of capacity – 320 KVA
Material Labour for replace to unserviceable automatic voltage regulator, Diod forward and reverse, rotating rectifier accessories complete to the following capacity of DG set . NOTE: Spare parts shall be measured and paid as "Supply only " separately under respective items. (ii) Fixing charges shall be deemed to be included in the unit rate of this item .Nothing extra shall be admissible on this account .
(a) DG Set of capacity - 125 /100 KVA
(b) DG Set of capacity – 63/82.50KVA
(c ) DG Set of capacity – 45/35/30/25 KVA
(d) DG Set of capacity – 10/15 KVA
Dismantling to radiator and cleaning the same completely and detect the leakage/breakage and repair to radiator by soldering/brazing and testing complete all as specified and as directed for the following capacity of DG Sets :-
(a) DG Set of capacity - 125 /100/82.50 KVA
(b) DG Set of capacity – 63/45/35/30/25 KVA
(c )DG Set of capacity – 10/15 KVA
Supply and top up coolant "K" Cool super plus-25/75 complete all as specified and as directed. MAKE: CASTROL/SERVO.
Supply only for changing engine oil & grade as per instruction of manufacturer including drain out existing used oil complete all as specified and as directed. MAKE: CASTROL/SERVO.
Supply only the following spare part for DG Set of capacity 750 KVA
(a) Lub oil Filter (Cat Part No DV0.014.11.0.00)
(b) Engine Oil Filter element ( Final Filter cartage ) Cat part no DV8.072.108.0.00
(c) Engine Oil Filter element ( Pre Filter cartage ) Cat part no D16.507.03.0.00
(d) Air cleaner primary Element Cat Part No F6.986.11.0.00
(e) Air cleaner Safty Element Cat Part No F6.986.12.0.00
(d) Air cleaner hose pipe with clamp
(e) Flexible pipe for fuel pump to PT pump with banjo nut, bolt & washer .
(f)Flexible pipe for Disel tank to filter with banjo nut, bolt & washer.
(g) Battary Charger for Automatic Panel
(j) By pass filter
Supply only the following spare part for DG Set of capacity 320 KVA
(a) Diesel filter element
(b) Engine Oil Filter element
(c ) Safety control valve
(d) Air cleaner hose pipe with clamp
(e) Flexible pipe for fuel pump to PT pump with banjo nut, bolt & washer .
(f)Flexible pipe for Disel tank to filter with banjo nut, bolt & washer.
(g) Air cleaner Filter
(h) By pass filter
Supply only the following spare part for DG Set of capacity 125/100KVA
(a) Diesel filter element
(b) Engine Oil Filter element
(c )Water pump assy
(d) Air cleaner hose pipe with clamp
(e) Radiator hose pipe with clamp
(f) Safety control valve
g) Flexible pipe for fuel pump to PT pump with banjo nut, bolt & washer .
(h)Flexible pipe for Disel tank to filter with banjo nut, bolt & washer.
(j) Bateery Charger for Automatic Panel
(k) Air cleaner Filter
(l) Oil pump
(m) By pass filter
Supply only the following spare part for DG Set of capacity 63/82.50KVA
(a) Diesel filter element
(b) Engine Oil Filter element
(c )Air cleaner hose pipe with clamp
(d) Radiator hose pipe with clamp
(e) Flexible pipe for fuel pump to PT pump with banjo nut, bolt & washer .
(f) Flexible pipe for Disel tank to filter with banjo nut, bolt & washer.
(g) By pass filter
(h) Automatic Voltage Regulator
(j) Oil Pump
(k) Air cleaner Filter
Supply only the following spare part for DG Set of capacity of 45/40/35/30KVA
(a) Diesel filter element
(b) Engine Oil Filter element
(c ) Air cleaner hose pipe with clamp
(d) Radiator hose pipe with clamp
(e) Flexible pipe for fuel pump to PT pump with banjo nut, bolt & washer .
(f) Flexible pipe for Disel tank to filter with banjo nut, bolt & washer.
(g) By pass filter
(h) Automatic Voltage Regulator
(j) Oil Pump
(k) Air cleaner Filter
Supply only the following spare part for DG Set of capacity 45KVA of Make :- JAKSON DG Set
(a) Diesel filter element
(b) Engine Oil Filter element
(c )Air cleaner Filter
Supply only the following spare part for DG Set of capacity 15/10 KVA
(a) Diesel filter element
(b) Engine Oil Filter element
(c )Radiator hose pipe with clamp
(d )Flexible pipe for fuel pump to PT pump with banjo washer , nut bolt
(e) Flexible pipe for Disel tank to filter with banjo washer , nut bolt
(f) Automatic voltage regulator
(e) Air cleaner Filter
Supply only following spare parts of self starter for DG Set of capacity 63/100/125 KVA as per existing make and cat part No:--
(a) Self clutch assembly
(b) Self pinion assembly
(c ) Self solenoid switch assembly
(d) Self Bandex Assembly
(e) Self carbon rocker assembly
(f) Self carbon brush (set of 4 pcs)
Supply only following spare parts of Battery charging Alternator for DG Set of capacity 125/100/63 KVA as per existing make and cat part No. :--
(a) Rectifier assembly
(b) Cut-out assembly
(c ) Rotor assembly
(d) Plate set (set of two pcs)
(e) Carbon (Set of 2 Pcs)
(f) Stator assembly
Supply only following spare parts of Battery charging Alternator for DG Set of capacity 35/30/45/40 KVA as per existing make and cat part No. :--
(a) Rectifier assembly
(b) Cut-out assembly
(c ) Rotor assembly
(d) Plate set (set of two pcs)
(e) Carbon (Set of 2 Pcs)
(f) Stator assembly
(g) Bearing No.6211ZZ
Supply only following spare parts of Battery charging Alternator for DG Set of capacity 10/15 KVA as per existing make and cat part No. :--
(a) Rectifier assembly
(b) Cut-out assembly
(c ) Rotor assembly
(d) Plate set (set of two pcs)
(e) Carbon (Set of 2 Pcs)
(f) Stator assembly
(g) Bearing No.6211ZZ
Supply only following spare parts of self starter for DG Set of capacity 45/35/30 KVA as per existing make and cat part No. :--
(a) Self clutch assembly
(b) Self pinion assembly
(c )Self solenoid switch assembly
(d) Self Bandex Assembly
(e) Self carbon brush (set of 4 pcs)
(f) Self carbon rocker assy
Supply only following spare parts of self starter for DG Set of capacity 15/10 KVA as per existing make and cat part No. :--
(a) Self clutch assembly
(b) Self pinion assembly
(c ) Self solenoid switch assembly
(d) Self Bandex Assembly
(e) Self carbon brush (set of 4 pcs)
(f) Self carbon rocker assy
Supply only following spare parts of FIP for DG Set of capacity 125/100/63 KVA as per existing :--
(a) Element
(b) Delievery valve
(c ) FIP Repair kit
Supply only following spare parts of INJECTOR for DG Set of capacity 125/100/63 KVA as per existing :--
(a) Injector nozzle
(b) Injector washer
Supply only following spare parts of FIP for DG Set of capacity 45/40/35/30KVA as per existing :--
(a) Element
(b) Delievery valve
(c ) FIP Plunger
(d) FIP Repair kit
Supply only following spare parts of FIP for DG Set of capacity 45/40/35/30KVA as per existing :--
(a) Element
(b) Delievery valve
Supply only following spare parts of FIP for DG Set of capacity 15/10KVA as per existing :--
(a) Element
(b) Delievery valve
(c ) FIP Repair kit
Supply only following spare parts of INJECTOR for DG Set of capacity 15/10 KVA as per existing :--
(a) Injector nozzle
(b) Injector washer
Supply and fixing for Engine stop solined switch for DG set of capacity 45/35/30 as per existing make and Cat No :-
Supply and fixing for Engine stop solined switch for DG set of capacity 125/100/63 as per existing make and Cat No :-
Supply and fixing for Alternator fly wheel ring gear for DG set of capacity 125/100/63 as per existing make and Cat No :-
S &F for battery lead with terminal cable of copper conductor size 19SWG and 90Cm long as in repair complete all as specified and as directed by Engineer-in-Charge.
Material & Labour for servicing & replacement wornout parts ( relays,metering equipments, control circuits etc.) of AMF pannel to the following capacity of DG set :- NOTE: Spare parts shall be measured and paid as "Supply only " separately under respective items. (ii) Fixing charges shall be deemed to be included in the unit rate of this item . No-thing extra shall be admissible on this account .
(a) DG Set of capacity – 125/100 KVA
(b) DG Set of capacity - 63 KVA
(c )DG Set of capacity - 30/35/45 KVA
Supply only power contactor 4 pole for 30/35/45 KVA DG AMF Panel.Make :- L&T Cat No CS97017/ Suchnieder / Seimens
Supply and fixing for battery of capacity 150 AH complete all as specified and as directed.Make: EXIDE new express Cat Part No.FXPO-MHD 1500 or Equivalent
Supply and fixing for battery of capacity 180 AH complete all as specified and as directed. Make: EXIDE new express Cat Part No.FXPO-MHD 1800 or Equivalent
Supply and fixing for battery of capacity 120 AH complete all as specified and as directed. Make: EXIDE new express Cat Part No.FXPO-MHD 1200 or Equivalent
Supply and fixing for Turbo charger repair kit for DG set of capacity 125/100/63 as per existing make and Cat No :-
Supply and fixing for Turbo charger repair kit for DG set of capacity 45/40/35 as per existing make and Cat No :-
KUNDAN ENGINEERS AND BUILDERS
Purbanchal Construction Co
M/s Capital Traders
Ms N D Enterpise
M/s Rawat Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .