| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC 2ND FLOOR SHAGUN PLAZA SHYAMPUR RISHIKESH DEHRADUN UTTARAKHAND | RISHIKESH | DEHRADUN | UTTARAKHAND | 249204 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹10.2 L+₹77,810 (8.26%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹10.3 L+₹87,150 (9.25%)Rejected-Finance | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹10.3 L+₹92,950 (9.87%)Rejected-Finance H NO 496 SECTOR 10 GURGAON 122001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹10.8 L+₹1.4 L (15.1%)Rejected-Finance H NO 82 C BLOCK NO CC SHALIMAR BAGH DELHI 110088 | DELHI | NORTH DELHI | DELHI | 110088 | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
5 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
PROVN OF SEWAGE SYSTEM OF 180 OR MD ACCN AT MAHIPALPUR UNDER AGE B/R-II (S) OF GE (SOUTH) DELHI CANTT-10
2021_MES_449277_1
GE/DS-26/2021-22
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
Garrison Engineer South Delhi Cantt 110010
₹28,000
Yes
7 Aug 2021
7 Jun 2021
7 Jul 2021
7 Jun 2021
5 Jul 2021
21 Jun 2021
8 Jun 2021 - 19 Jun 2021
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc for manholes, pipes, wells etc not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out in any type of soil, complete all as specified and directed by Engineer-in-Charge.
All as per Ser item No 01 above but exc 1.5m depth but n. exc. 3.00m depth, complete all as specified and directed by Engineer-in-charge.
All as per Ser item No 01 above but exc 3.00m depth but n. exc. 4.50m depth, complete all as specified and directed by Engineer-in-charge.
Returning, filling in, inluding spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25cm thick in trenches, after the pipes have been laid and tested, complete all as specified and directed by Engineer-in-Charge.
Removing excavated material any type of soil exc 50 m but not exc 250 m deposited where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete, complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' bricks strainght or curved on plan not exceeding 6m mean radius built in cement mortor 1:6, complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brickwork/ concrete surface, finished even and smooh without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Supply only integral water proofing compound, complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping and similar work etc. including weathering, slightly rounded or chamferred angles and throating and provision of necessary formwork, complete all as specified and directed by Engineer-in-Charge.
S&F SFRC manhole cover 70mm thick of any size and shape with frame set in CM 1:4, complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete (1:3:6) , type C-2, using 40mm grade stone aggregate as in concrete bed to drain pipes laid to falls in trenches in any depth including packing under and haunching against the sides for 150mm bore pipes with concrete after the pipes are laid and tested, complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete (1:3:6) , type C-2, using 40mm grade stone aggregate as in concrete bed to drain pipes laid to falls in trenches in any depth including packing under and haunching against the sides for 200mm bore pipes with concrete after the pipes are laid and tested, complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete (1:3:6) , type C-2, using 40mm grade stone aggregate as in concrete bed to drain pipes laid to falls in trenches in any depth including packing under and haunching against the sides for 300mm bore pipes with concrete after the pipes are laid and tested, complete all as specified and directed by Engineer-in-Charge.
M&L for SGSW drain pipes 150mm dia laid in trenches and jointed in CM (1:3), complete all as specified and directed by Engineer-in-Charge.
M&L for SGSW drain pipes 200mm dia laid in trenches and jointed in CM (1:3), complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced concrete pipes, class NP2 laid intrenches and jointed in CM (1:3) with collars complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete(1:2:4) type B-2 using 20mm graded stone aggregate as surface channel/drains inside the manholes and like including weathering, slightly rounded or chamfered angles and throating as directed and provision of necessary formwork to any extent and finished exposed surface even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Dismantling of cast iron or reinforced concrete drain pipes up to 100mm bore, jointed in cement mortar and taking out of trenches, if required, complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm dia cast iron (sand cast ) soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floor, complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm dia cast iron (sand cast ) soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to wall, complete all as specified and directed by Engineer-in-Charge.
S&F 75 mm dia cast iron (sand cast ) soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to wall, complete all as specified and directed by Engineer-in-Charge.
S&F cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, bore of pipe 100mm, complete all as specified and directed by Engineer-in-Charge.
S&F cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, bore of pipe 75mm, complete all as specified and directed by Engineer-in-Charge.
S&F cast iron bends (any radius), diminishing pieces or tapers (larger bore measured), bore of pipe 100mm jointed with polymer based jointing material without oval access door, complete all as specified and directed by Engineer-in-Charge.
All as per Ser Item No. 25 above but here in before but 75mm bore of pipe, complete all as specified and directed by Engineer-in-Charge.
S&F holder bat clamps 100mm bore out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, complete all as specified and directed by Engineer-in-Charge.
All as per Ser Item No. 27 above but here-in-before but 75mm bore, complete all as specified and directed by Engineer-in-Charge.
Taking down rain eaves gutter rain water pipe (any size) or pattern incl all fittings, head shoes, bends swan necks etc incl cleaning or re-fixing or removal to store (measured overall as fixed along the centre line over fittings and accessories, complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) pipes, 110mm dia single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) bends/ Tee any radius, 100mm bore, complete all as specified and directed by Engineer-in-Charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
Chaudhary Constructions
M/S.M.S.Devi.Const.Co
P R Constructions
M/S GOPAL JEE SINGH
Vipul Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .