| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.6 L+₹1.6 L (12.9%)Rejected-AOC CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | L2 | Rejected-AOC L2 | |
| 3 | L3₹14.0 L+₹1.9 L (16.0%)Rejected-AOC WARD NO 4 NEAR MASZID BHATTAGAON DISTT JHANSI 284001 UTTAR PRADESH | JHANSI | UTTAR PRADESH | 284001 | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
Closing Date
25 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I TALBEHAT
LAKEVIEW CAMP MIL STN TALBEHAT 284125
SPL REPAIR TO BLDGS NO TP-74/1, TP-74/2, TP-81/2, TP-82/1 AND TP-82/2 IN ZONE 9B AT TALBEHAT MIL STN
2021_MES_434612_3
AGE(I)/TBT/TOK-06/2021-22
Open Tender
Civil Works
Item Rate
180 days
MILITARY STATION TALBEHAT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I TALBEHAT
Exempted
14 Jun 2021
8 May 2021
31 May 2021
8 May 2021
25 May 2021
13 May 2021
60 days
Amount
Taking down cement or cement lime plaster on brick wall, ceiling incl. Raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L15mm thick plaster in CM 1:6 on fair surfaces of walls finished even and smooth w/o using extra cement complete all as specified and directed.
M&L for 15mm thick external plastering in CM 1:4 on fair faces of brick work or concrete surface finished even and smooth w/o using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall over a coat of primer on surface and applying two coats of oil bound distemper complete all as specified and directed.
M & L preparation new plastered surfaces of walls and providing two coat of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation of old plastered surfaces of wall and applying one coat of white wash complete all as specified and directed
M&L for complete removal of existing treatment of old wall and applying two coats of oil bound distemper complete all as specified and directed.
M & L complete removal of existing treatment of old wall and providing two coat of cement base paint over a coat of primer complete all as specified and directed.
M & L preparation old decorated surfaces of walls and providing one coat of cement base paint complete all as specified and directed.
M&L for preparation of surface 1mm thick wall care putty complete all as specified and directed.
Demolition of cement concrete (unreinforeced) in floors and paving n.exc 15cm thickness (above or below ground level) complete all as specified and directed.
Demolition of stone/ brick masonry built in cement or cement lime mortar as in portion ordered and directed.
M&L for brick work with old size sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
Ditto above item except brick complete all as specified and directed.
M&L for PCC 1:2:4 Type B-0 (using 12.5 mm stone crushed agg.) as in coping, rounded or chamfered on edges in any description complete all as specified directed.
M&L PCC (1:3:6) type C-1 using 20mm graded stone aggregate 50mm thick as in plinth protection finished fair even laid in alternate bays n.exc 2m in length all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n exc 1.50 sqm each and removing from site spd and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm and n.exc 4.00 Sqm each and removing from site completeall as specified and directed.
Taking down shutters of any description exc. 1 Sqm and nexc. 2 Sqm each .
M & L for rolled mild steel work angle iron as in door frame (Chowkhats) & cooler stand and one two coat tar and sanding newly tarred surfaces with clean sharp sand complete all as specified and directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with M S square tube, supplying and fixing in opening as per specification and drawing complete all as specified and directed
S & F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded. sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawings on page 146 of SSR Part - II 2004 complete all as specified and directed.
S & F second class HW Hollock/Bonsum/Sal 35mm thick, factory made, plain framed, panelled shutter with panels of 9mm thick BWP grade ply wood bonded with high quality liquid phenol formal dehyde synthetic resin adhesive conforming to IS-710. The size of rails & style shall be as per IS-1003 (part-I) kiln seasoned as per IS-1141 & chemically pressure treated as per IS-401 complete all as per specified and directed.
S & F for 2nd class HW 35 mm thick, gauged and skeleton shutters (Three Panels), factory made open rebated and prepare to receive glass, gauge etc (with sash bar), edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass etc. Size of members of shutter shall be as specified in SSR 2009 Part-I, section 8 clause Member shall be kiln seasoned as per IS-1141 & chemically pressure treated as per IS-401 complete all as specified and directed.
S&F powder coated anodized aluminium frames for door, window , ventilators with one or more rebates including joining cleats for fixing etc complete all as specified and as directed by Engr-in-charge
S&F powder coated aluminium anodized sliding/side hung type window/ventilators shutter without sash bars section weight not less than 0.55Kg/RM with extruded built up standard tubular and other sections of approved make according to IS(thickness of powder coating not less than 50micron including necessary glazing clips weight not less than 0.124Kg/Rm for fixing sheet glass anodized aluminium fittings/fixtures such as required number of roller of suitable size interlocking cleats/ plates etc as required for complete fixing window shutters complete all as specified and as directed by Engr-in-charge. Note:- Only aluminium shutters for the window shall be measured in sqm sheet glass and hardware such as rubber beading,handles,locking arrangement etc shall be measured and paid in respective items
S&F powder coated aluminium anodized fixed type window/ventilators shutter without sash bars section weight not less than 0.55Kg/RM with extruded built up standard tubular and other sections of approved make according to IS(thickness of powder coating not less than 50micron including necessary glazing clips weight not less than 0.124Kg/Rm for fixing sheet glass anodized aluminium fittings/fixtures such as required number of roller of suitable size interlocking cleats/ plates etc as required for complete fixing window shutters complete all as specified and as directed by Engr-in-charge. Note:- Only aluminium shutters for the window shall be measured in sqm sheet glass and hrd ware such as rubber beading,handles,locking arrangement etc shall be measured and paid in respective items
S&F rubber beading, handle, locking arrangement for each window complete all as specified and as directed by Engr-in-charge
S&F in position 4.8 to 5mm thick clear float glass of ordinary quality and glazing with glazing clips including necessary rubber packing to aluminium frame exc 0.5 sqm in each pane complete all as specified and as directed.
S&F steel window/Ventilator with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete but with glazing bars, complete all as specified and directed.
S&F steel window/Ventilator with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete but without glazing bars, complete all as specified and directed.
M&L for MS framed work such as 10mm square guard bars conforming to Fe 290-0 or Fe 330-0 welded to ventilator/window complete all as specified and directed
S & F 150 mm long floor door stopper of Aluminium alloy body tongue, anodised, with hard drawn steel spring fixed to door.
S&F mild steel butt hinges, medium weight, cold rolled, ISI marked of size 100 mm, complete all as specified and directed.
S&F butt hinges 100mm extruded aluminium alloy with galvanised mild steel hinges pin anodised and fixed.
S&F 125mm size aluminium alloy handles, fabricated type extruded section, ISI marked all as specified.
S&F 100mm size aluminium alloy handles, fabricated type extruded section, ISI marked all as specified.
S&F aluminium, anodised, barrel tower bolt of extruded section, ISI marked, 150 mm long complete all as specified and directed.
S & F 125mm single action spring hinges, mild steel with steel wire spring, stove enamelled black, complete all as specified and directed.
S&F 250mm long alumn. alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section all as specified
M & L for preparation of new wooden surface over 10cm width or girth and applying two coats of synthetic enamel paint of Ist quality over a coat of pink primer complete all as specified and directed.
M&L for preparation of old painted wooden surface of any description and applying one coat of synthetic enamelled complete all as specified and as directed by Engr-in-Charge
M&L for preparation of new steel surface over 10cm width or girth & applying two coats of synthetic enamel paint of 1st quality over a coat of red oxide primer complete all as spd & directed.
M&L for preparation of old painted steel surface of any description and applying one coat of synthetic enamelled paint complete all as specified and as directed by Engr-in-Charge
S&F 3.00 mm thick sheet glass, ordinary / figured quality & glazing with oil putty not exc 0.50 Sqm each pane complete all as spd & directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm completed all as spd & directed.
S&F in repair fancy type 20mm dia aluminium curtain rods powder coated fixed to bracket completed all as spd & directed.
S&F decorative type knobs with bracket of MS powder coated fixing at end of pelmet rod complete al as spd & directed.
Dismantling of ceiling board/lathing any thickness including frame work complete all as specified and directed.
Providing & Fixing false ceiling with Everest Fibre Cement Designer tile Ivory painted (High Pressure Steam Cured) of 4mm thickness (as per IS:14862) of size 595x595 mm and any one of the design (oceanic, lake & hill, cascade or Electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and 15x32 mm made from 0.30 mm thick sheet, spaced at 1200 mm c/c and cross "T" of size 15x32 mm made of 0.30 mm sheet, 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size15x32 mm made of 0.30 mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 15x20 mm made of 0.30 mm thick sheet and laying false ceiling tiles in the grid including , required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15mm of all T -sections shall be centra black pre-painted with polyester paint, and having a load bearing capacity of 12 kg/sqm, all complete at all heights as per direction of Engineer-in-charge.
Cutting holes into or through brick wall built in cement lime mortar and walls of cement concrete of superficial area exc 150 sqcm but n exc 400 sqcm and making good in CM 1:3 or cement concrete 1:2:4 type B-1 as required.
S&F rolled mild steel section work as in main and cross beam, hip and jack rafters purlins where connected to common rafters and running rails and guides for sliding door fixed with angle cleats or other connecting plates confirming to Fe 410W(Gde E-250 quality A)complete all as specified
Dismantling Asbestos Cement (corrugated, semi corrugated, etc) sheets in roof covering complete all as specified & directed.
M&L for 6mm thick asbestos cement corrugated or semi corrugated sheets in roof, wall etc fixed with L-type or cranked hood bolts complete all as specified and as directed by Engr-in-Charge
All as per srl item above but except sheets.
M&L for 6mm thick asbestos cement two piece adjustable plain wing ridge fixed with L-type or J-type or cranked hook bolt complete all as specified and directed by Engr-in-Charge
Dismantling of timber scantling 40Sqcm and over in section in any position such as in rafter, purlins etc in unframed work complete all as specified and as directed
Dismantling in unframed fillets, rails, posts, rafter, purlins etc under 40 sqcm in section complete all as specified and directed
M&L for 2nd class hard wood exc 13 & n exc 25Sqcm plain fillets, square, rectangular in section, clean sawn, secured with nails or brads complete all as specified and directed
Dismantling floor, hearth or wall tilling including cement mortar bedding, and rubbish off premises etc complete all as specified and directed.
M & L for Non-skid Ceramic tiles 7 to 8 mm thick ( square /Rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured in white or coloured cement to match with tile laid over and including screed bed or bedding layer of 15 mm thick in CM (1:6), complete all as specified and directed.
M&L for Non-Skid ceramic coloured tile 7 to 8 mm thick (square/rectangular) area of each tile exc. 0.11 sqm but n.exc. 0.18 sqm on vertical surfaces of wall such as dados, skirting etc set & jointed in neat slurry and pointed in white or colour cement to match over 10mm thick cement plaster in CM 1:4 complete.
M&L for coloured ceramic tiles 450 x 300 x 7mm thick tiles on walls, set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile over and including cement mortar 1:4, 10mm thick complete all as spd & directed.
M&L for form work, fair finished to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works flat n exc 200mm thick (Horizontal or slopping) etc complete all as specified and directed.
M&L for form work fair finished to edges of concrete flats, treads floor and roofs n exc 20 cm wide and sides of RCC/PCC bends in walls (horizontal or slopping) and similar works exc 10 cm but n exc 20 cm wide complete all as specified and directed.
S&F steel reinforcement of TMT Bars of size 8mm dia and over cut to length bent to shape as required including cranking hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed.
M & L for RCC 1:1.5:3 (Nominal Mix), type B 1, using 20mm graded crushed stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc .complete all as specified and directed.
M & L for 20mm thick granite on kitchen platform and similar work over & including 15mm thick screed bed in CM 1:6 laid over sand stone slab machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing complete all as specified & directed.
Dismantling of existing unserviceable water tank of any description capacity exc 250 Ltr but n.exc 500trs capacity each complete all as specified and directed
S& F rotational moulded synthetic (HDPE) water storage tank 500litre capacity hoisted & fixed in position all as specified in SSR Part-I complete all as spd & directed.
S&F ball valves PTMT high pressure with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe, 20mm bore compete (Minimum weight 210 gm) complete all as spd & directed.
S&F in repairs gun metal globe or gate valve, wheel head cast copper alloy screwed down light pressure with crutch or butterfly handle screwed both ends for iron pipe or for union 20 mm dia, ISI marked complete all as spd & directed.
Taking up or down steel tubing and connection 15 mm bore and removing the same from site/keeping aside for reuse complete all as specified and directed.
All as per srl item above but 20 mm bore
S & F water tubing 15 mm bore, medium weight, ISI marked galvanized with all fittings and fixed to walls, ceiling or laid in floors complete all as specified and directed.
All as per srl item above but 20 mm bore
M & L for refixing 15mm bore old GI tubing to walls, ceiling or laid on floor including necessary cleaning, cutting, screwing and new fittings such as elbow, Tee, union, socket, reducer etc.
All as per srl item above but 20 mm bore
S&F in repairs wash hand basin vitreous china white / ivory colour flat size 550 x 400mm fixed including waste coupling, waste pipe & connection pipe complete all as specified and directed
Taking out old unserviceable water closet (squatt pattern) and S & F Vitreous China, Squatting pan Orissa pattern size 580 x 440mm, white with integral foot rests (excluding flushing cistern and flush pipe ) with Vitreous China ‘P’ or ‘S’ trap, front or back inlet including connection to trap and to flushing pipe, anti syphonage pipe , including PCC (1:2:4) type B-1 for fixing of WC and making good the floor to match the existing complete all as specified and directed.
Taking down old unserviceable flushing cistern S&F PVC valveless syphonic action type low level flushing cistern, 10 Ltrs capacity . White, with inlet ball valve, float, handle with 32mm PVC flush pipe, fixed on walls by driling holes and using PVC rawl plug of suitable size complete all as specified and directed.
Taking down old unserviceable PVC connection and S & F PVC connection, heavy duty 15 mm bore, 45 cm long with two Nos PTMT nuts at both ends of approved quality complete all as specified and directed.
S&F in repairs 32mm bore PVC waste pipe any length with one end socketed complete all as spd & directed.
S&F in repairs pillar taps fancy type cast copper allloy capston headed, chromium plated, screwed down, high pressure with long screwed shank and fly nut, screwed for 15mm bore iron pipe complete al as spd & directed.
S&F in repairs PVC (SWR) 75mm dia single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed. .
S&F PVC floor trap with grating 75mm dia fixed with cement joint complete all as specified and directed.
S&F in repairs grating square 125mm size of PTMT with centre hole movable or side hole for fix to waste pipe complete al as spd & directed. (Min Wt- 100 gms)
S&F in repair Soap dish any type, fixed to plugs with chromium plated brass screws embedded in the wall complete all as sped & directed.
Taking out old un serviceable tubular towel rail & S&F tubular towel rail aluminium anodised 20mm dia 'D' type 60cm long between flanges complete all as sped & directed.
S&F in repairs Chromium plated Angle cock 15 mm dia screwed down light pressure screwed both ends for iron pipe or for union complete all as spd & directed
S&F in repairs Chromium plated bib taps, with capstan heads, screwed down for iron pipe or for brass ferrule & fixed for 15 mm bore pipe complete all as specified & directed.
Taking down old unserviceable Chinaware sink and S&F steel made of stain less steel 1mm thick kitchen or laboratory with plugs, washers and waste pipe including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union overall size not less than 495x429mm, bowl size 410x330x 160mm complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. Note: All debris obtained from demolition shall be removed 1.5 km to 2km complete all as specified and as directed.
M&L for PCC 1:4:8, type D-2 using 40mm graded stone aggregate as in foundations, fillings, mass concreting complete all as specified and directed.
M & L for PCC inter locking tiles, coloured, reflective type/rubber moulded, conforming to IS-15658-2006 of 60mm thick , M-35 grade of approved quality, laid over and incl 50 mm thick sand cushion vibrated with mechanical vibrator complete all as specified and directed.
Taking down carefully copper/Aluminium point wiring (light/fan/socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors etc complete all as directed.
Taking down Distribution Boards along with MCB's incl removing the same from site and making good to the disturbed surface complete.
M/L for point wiring concealed type with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl FRLS PVC rigid conduit not less than 20 mm dia with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: Wire: Make -Mescab/Polycab/KEI PVC conduit: Make -Polycab/Precision/Plaza Note:- On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit/PVC Casing caping and its accessories.
One light/fan/bell point controlled by one No. piano type switch 5 Amp single pole one way
One socket outlet 5/3 pin 6 Amp controlled by one switch on the same board.
One socket outlet 5/3 pin 6 Amp controlled by one switch on independent board.
All as per item NO 99.00 above but 3 pin socket out let 15/16 Amp on the independent Board all as spfd with single core unsheathed PVC insulated cable multistranded copper conductor of size 4 sq mm for phase & neutral & 4 sq mm for earth continuity conductor.
S&F Switch Piano Flush button single pole one way 5/6 Amp. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Switch Piano Flush button single pole one way 15/16 Amp. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F socket outlet 2 in 1, 3 pin & 2 pin, 5/6 Amp, 240 volt. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F socket outlet 2 in 1 , 3 pin & 2 pin, 5/6 Amp and 15/16 Amp, 240 volt. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F ceiling rose three phase PVC/Polycarbonate. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Lamp hoder/Batten holder PVC/Polycarbonate insulated body with metal ring and back plate for batten fitting. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Bell Ding Dong type, AC 230 Volts, Single pole. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Bell Push, flush type, 5 Amp, AC-230 Volts, single pole. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F steped type, electronic fan regulater on the exisiting phenolic laminated sheet. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way with bus bar 240 volts double door (Metallic) type. Make:- Hager/IndoAsian/Siemens.
S&F MCB SP 5 to 32 Amp 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
S&F MCB SPN 20 to 40 Amp 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab framed with 50X30X4 mm MS angle (reinforced with 6 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and magnesium sulphate in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect., GI earth wire protected by 40 mm bore (light grade) galvanized iron pipe and other end connected to the earth bar (test point) made of MS flat (400X32X6 mm) bend in ‘D’ shape and fixed to wall by means of fast nut or bolt grouted in to wall at 1 mtr from plinth height. 4sqmm PVC insulated (colour green) copper conductor single run as earth continuity conductor along with 15 mm PVC conduit grouted in wall or fixed on wall surface to be continued up to main switch board and fix with common earth dolly as directed by EIC . Disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete all as specified and as directed.
S&F in replacement of tube light fitting LED 20 Watt, 6000K, 230 Volt, LED batten complete with high brightness LED tube rod in opal finish and connection with PVC insulated multi stranded copper flexible wire twin core of suitable size from nearest source complete all as specified and as directed by Engineer-in-Charge. Make : Bajaj/ Havells/ Philips.
S&F exhaust fan metallic body size 300mm, 1400 RPM, including louver complete all as specified and as directed by Engineer-in-Charge. Make- Havells, Orient, Crompton Greaves, USHA
S & F LED Bulb 7 Watt cool day light for fixing on holder. Make : Havells / Bajaj/ CG/Surya/Philips
Supply and laying or fixing or passing through pipe in replacement, 1100 volt grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1.00 metre apart including 4 mm dia suspension wire one twin core cable flat or circular of size 10 sq mm 2 core complete all as specified and directed by Engineer-in-charge. Make:- Havells/ Finolex/RPG
S & F house service braket hook type complete with 3.0m long GI pipe 40mm dia med grade 2 Nos 90 degree bends MS hook and stay or guy.
S & F LED bulk head 12 Watt energy saving & environmental friendly long life IP-65 with high power LED as light source, seperate driver compartment complete all as specified and as directed by Engineer-in-Charge. Make : Havells / Bajaj/ CG/Surya.
HARNAM SINGH ANIL SINGH
M/s JS Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .