Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹19.9 LAccepted-AOC | 1 | Accepted-AOC LOWEST BIDDER | |
| 2 | 2₹20 L+₹8,700 (0.44%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹20.9 L+₹1.0 L (5.04%)Rejected-Finance 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | 3 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹46,600
Closing Date
23 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE North Patiala
Military Engineer Services, Garrison Engineer (N) Patiala, Sangrur road, Patiala Cantt
As per tender documents
2021_MES_408667_1
GE(N)/PAT-37/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
Patiala Cantt
Please refer Tender Documents
6 documents required · 6 mandatory
₹500
Yes
GE (N) Patiala
₹46,600
Yes
13 Feb 2021
1 Jan 2021
25 Jan 2021
1 Jan 2021
23 Jan 2021
9 Jan 2021
1 Jan 2021 - 8 Jan 2021
60 days
Amount
Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA compatible with 1.5 Ton AC Complete all as specified and directed.
Supplying & fixing of Aesthetically Designed LED flood light luminaires of 120 watts System wattage for energy saving having IP-66 degree of protection ,With minimum system efficiency as > 85 % ,made of Pressure die cast aluminum housing powder coated in graphite grey and heat resistant thoughned glass with excellent thermal management including PVC cable connector. LED's should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light. Fitting should have operating voltage range of 120 - 270 VAC , THD <10% , P.F >.95, System Efficacy > 90 lm/W and IP65 Class-I protection. The fitting should have in built surge protector of 5 KV and CRI > 70 with CCT 5700 K complete all as specified and directed
M&L for frame work with 32 mm dia GI pipe suitable for symmetrically fitting of 4 Nos of 120 Watts LED flood light fitting on 360 degree angle complete with MS clamp bolts and nuts, internal dia of frame is 100cm including nencessary mounting arrangement on 10 mtr long steel tubular swaged pole complete all as specified and directed by Engr-in-Charge
Supply & fix steel tublar pole 10 mts long with cast iron base plate ,final taper plug, bolts nut and screw all as specified type 410 SP-44 (10 metres long) including painting with two coats aluminium paint over a coat of red oxide primer complete all as specified and directed
S&F in trenches through pipe under culvert or in air XLPE cable insulated PVC sheathed heavy duty 1100 volts grade stranded aluminum conductor of 10 Sqmm, 4 core complete all as specified and directed.
Excavation in trenches soil n.exe 1.5 mtr wide and 1.5 mtr deep for laying of cables including taking down complete all as specefied and directed.
Excavation in trenches soft/loose soil n.exe 1.5 mtr wide and exc 1.5 mtr deep up to 3.0 mtr for laying of cables/poles including taking down complete all as specefied and directed.
Returning filling of layers including spreading, leveling complete all as specefied and directed.
Removing surplus spoil to a distance not exceeding 50 m and depositing where it is directed complete all as specefied and directed.
M & L for precast concrete cable covers type 2 flat, size 250mmx150mmx40mm laid dry in trenches for cable protection all as specified and directed by Engineer in Charge.
Sand bedding for coushing of cables complete all as specefied and directed.
Supply and fix PVC insulated round/flat copper cable of size 3 core 1.5 sq mm for connection of LED lights from FRP junction box to street light fittings complete all as specified and directed.
Supply and fix junction box made out of PVC 30cmx20cmx10.5cm complete including aluminium busbar of suitable size three phase and neutral with insulators and 4XMCB SP of 16 Amps complete all as specified and directed.
Material and labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate for foundation of pole all as specified and directed.
Material and labour for PCC 1:3:6 type C-2 using 20 mm graded stone aggregate for copping around the pole strut above ground level, foundation of stay etc. including neccassory form work and finishing the surface fair and even without using extra cement all as directed and specified
S&F GI pipe light grade 40 mm passing through cables, walls , across the roads with proper clamps, nut & bolts including taking down complete all as specefied and directed.
Supply and fixing of automatic street light control switch single phase 5-8 KW 40 Amps using infrared sensor based nature switch for automatic switching of street lights. Nature switch operation should be based on Natural light lux level. The sensor along with suitable power contactors and incoming out going MCBs should be enclosed pole/wall mounted thermo plastic polycarbonate enclosure conforming to IP 66 protection class 2. Make: Nature switch: Kakatiya Energy systems/BAJAJ/Healer Contactors: BCH/L&T/Schneider MCBs: Hager/Schneider/L&T Enclosure: Hensel/GE or equivalent Circuit wiring: Polycab/ Finolex or equivalent
Earthing complete with Galvanized steel earth plate 600 x 600 x 6.0 mm buried directly in ground (earth pit not less then 2.25 Mtr deep below ground level) with top edge of the plate not less then 1.5 Mtr below normal ground level connected togalvanized earth lead wire 4.0 mm dia by means of bolts ,nuts ,check nuts and galvanized iron or steel incl excavation and earth work, GI pipe light grade 25mm/40 mm bore for protection of GI wire /strip from earth electrode to and incl the earth test point of gun metal or phosphorus bronze size of size 75 X 75 X 25mm drilled and screwed including, 3 NOS, 8mm dia 25mm long hex, head screw supplying and lying charcoal dust, common salt, PCC 1:3:6 type CI (using 20 mm graded crushed stone aggregate) as in chamber and MS angle iron frame 40 x 40 x 3mm and RCC cover 40 mm thick 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia. TMT bars @ 75mm c/c both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No. 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed
Suppy and fix Rigid non-metallic PVC conduit 20 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers,lock nuts,saddles,pipe hooks etc.
S&F MCB DB TPN 4ways VTPN series double door 415 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete all as specified and directed.
S&F MCCB,4 Pole ,415 volts, 125 amp, 16 KA rupturing capacity for fixing in DBs of including proper thimble connections complete all as specefied and directed.
Supply & laying cable XLPE insulated screened PVC bedded , galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core
Fixing only water heater storage type of capacity 25 including all necessary required acessiories like necessary nut bolts, washers, screws etc complete all as specefied and directed.(NOTE : Geyser will be issued in sch B for fixing .)
Supply and fix as in replacement brass chromium plated connection pipe 450 mm long with two adopter and rubber washers suitable for 15 mm bore pipe suitable for hot water/cold water complete all as specified and directed
S & fixing GI tubing 'medium grade' 15 mm bore with all necessary fittings like elbow, reducer, T-joint, nipple and passing through brick walls, ceilling orlaying in floors, tapping from existing lines and necessary cutting, caushing of walls etc complete all as specefied and directed.
S & F gun metal gate valve, suitable for 15mm bore GI pipe with iron wheel head, screwed both end for GI pipe with all necessary fittings complte all as specefied and directed.
S & F gun metal non return valve, suitable for 15mm bore GI pipe with screwed both end for GI pipe with all necessary fittings complte all as specefied and directed.
Supply and Fixing Bib tap cast copper alloy with butter fly handle suitable for 15mm GI pipe with necessary fittings complete all as specefied and directed.
S&F MCB, single pole 240 volts 20 to 40 Amp, 10 KA capacity fixing in DB’s including proper thimble connections complete all as specefied and directed. Make:- Indo Asian,standard, havells.
Supply and fix earth metal plug including mcb 20 amp complete all as specified and directed.
M&L for sub main wiring with two single core 6 Sqmm PVC insulated and unsheathed FR ,stranded copper conductor cable drawn in and incl PVC rigid non metallic concealed conduit 25 mm dia incl 4.0 Sqmm PVC insulated unsheathed FR stranded copper conductor cable as earth wire all as specified and directed. (NOTE: Cutting chasis and conduit pipe ISI marked included in this item alongwith repairing the surfaces in CM 1:3 and finishing the surface as per exisiting treatment all as specified and directed)
Arneja Builders
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .