Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAdmitted-Finance AT SHRI RAMADHAR YADAV WEST ABHIYANTA NAGAR BAILEY ROAD DANAPUR PATNA BIHAR 801503 | DANAPUR | PATNA | BIHAR | 801503 | ₹36.7 L | L1 | Admitted-Finance |
| 2 | L2₹41.1 LAdmitted-Finance 6 9 GRAND SQUARE DANAPUR CANTT PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | ₹41.1 L | L2 | Admitted-Finance |
| 3 | L3₹43.6 LAdmitted-Finance | ₹43.6 L | L3 | Admitted-Finance |
| 4 | L4₹44.4 LAdmitted-Finance | ₹44.4 L | L4 | Admitted-Finance |
| 5 | L5₹44.7 LAdmitted-Finance KAGZI MOHALLA DANAPUR CANTT PATNA 801503 | PATNA | PATNA | BIHAR | 801503 | ₹44.7 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SINHA CONSTRUCTION L5 | M/s Naresh Chand Agrawal L2 | RAJ AND SONS L6 | ANAHITAS INFOSOLUTIONS PRIVATE LIMITED L1 | VAISHNAVI CONSTRUCTION L4 | M/S SAROJ KUMAR SINGH L7 | HARINANDAN RAI SONS L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply & Fixing in replacement split type air conditioner of capacity 2.0 TR 4 star rating and EER 3.2 with cordless remote control unit and in built air ioniser ,plasma filter for better indoor air quality, suitable for wall mounted,single phase, 230/250 volt AC including making necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing after commissioning as required at site, making necessary connections and M & L for unplasticised PVC pipes medium duty 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer,testing of AC complete all as specified and directed. | 14 | Each | 1,25,000 ₹17.5 L | 1,10,000 ₹15.4 L | 1,22,000 ₹17.1 L | 81,000 ₹11.3 L | 1,17,650 ₹16.5 L | 1,20,000 ₹16.8 L | 1,20,000 ₹16.8 L |
| 2.00 | Supply & Fixing in replacement split type air conditioner of capacity 1.5 TR 5 star rating and EER 3.2 with cordless remote control unit and in built air ioniser ,plasma filter for better indoor air quality, suitable for wall mounted,single phase, 230/250 volt AC including making necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing after commissioning as required at site, making necessary connections and M & L for unplasticised PVC pipes medium duty 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer,testing of AC complete all as specified and directed. | 23 | Each | 71,000 ₹16.3 L | 80,000 ₹18.4 L | 75,200 ₹17.3 L | 70,800 ₹16.3 L | 72,450 ₹16.7 L | 75,000 ₹17.3 L | 69,000 ₹15.9 L |
| 3.00 | Supply and fixing wall mounting voltage stabilizer for automatic operation single phase naturally air cooled indooor type and designed for input voltage between 130 volt to 280 volts with output voltage stabilized at 230 V +/- 2.5% with time delay relay and suitable for fixing / mounting on wall of capacity 4 KVA copper wound complete all as specified and directed. | 23 | Each | 7,900 ₹1.8 L | 8,000 ₹1.8 L | 7,650 ₹1.8 L | 6,608 ₹1.5 L | 8,200 ₹1.9 L | 8,000 ₹1.8 L | 8,000 ₹1.8 L |
| 4.00 | Supply and fixing wall mounting voltage stabilizer for automatic operation single phase naturally air cooled indooor type and designed for input voltage between 130 volt to 280 volts with output voltage stabilized at 230 V +/- 2.5% with time delay relay and suitable for fixing / mounting on wall of capacity 5 KVA complete all as specified and directed. | 14 | Each | 9,000 ₹1.3 L | 9,000 ₹1.3 L | 9,250 ₹1.3 L | 7,434 ₹1.0 L | 9,200 ₹1.3 L | 9,000 ₹1.3 L | 8,800 ₹1.2 L |
| 5.00 | Supply & fixing factory made,universal bracket / wall mounting stand ,made with galvanized structural steel,high strenth,weather proof,powder coated,modular construction and weight not less than 5 Kg and suitable for upto 2 TR capacity split type AC. | 37 | Each | 1,725 ₹63,825 | 1,200 ₹44,400 | 1,600 ₹59,200 | 1,321 ₹48,877 | 1,625 ₹60,125 | 1,600 ₹59,200 | 1,600 ₹59,200 |
| 6.00 | S & F copper connection pipe with union at both ends as required (for suction & discharge ) with insulation and PVC insulated FRLS multi strand copper conductor cable of size 4.0 Sqmm three core ( R,B,G) between FCU unit and indoor unit for extension or as required for installation of split AC in any length suitable for 1.5/2 TR Split type AC, making connection & testing complete all as specified. ( Note - One run of suction and one run of discharge pipe with insulation & PVC insulated FRLS multi strand copper conductor cable of size 4.0 Sqmm three core ( R,B,G) will be measured as one unit length | 42 | RM | 2,350 ₹98,700 | 2,300 ₹96,600 | 2,200 ₹92,400 | 2,020 ₹84,840 | 2,420 ₹1.0 L | 2,500 ₹1.1 L | 2,200 ₹92,400 |
| 7.00 | M & L in repair for power/sub main wiring with two runs of single core 10 sqmm size and one run of single core 10.0 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed.( Note - two runs of 10 sq mm single core copper conductor and one runs of 10.0 Sq mm copper conductor shall be measured as one unit length.) | 150 | RM | 1,470 ₹2.2 L | 800 ₹1.2 L | 1,500 ₹2.3 L | 1,321 ₹2.0 L | 1,615 ₹2.4 L | 1,600 ₹2.4 L | 1,600 ₹2.4 L |
| 8.00 | M & L in repair for power/sub main wiring with two runs of single core 4 sqmm size and one run of single core 4.0 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed. Note : two runs of 4 sqmm single core copper conductor and one runs of 4.0 Sq mm copper conductor shall be measured as one unit length.) | 255 | RM | 1,200 ₹3.1 L | 300 ₹76,500 | 1,200 ₹3.1 L | 991 ₹2.5 L | 1,235 ₹3.1 L | 1,400 ₹3.6 L | 1,200 ₹3.1 L |
| 9.00 | Supply & fixing in repair earth plug enclosure (plug and socket ) with and including one MCB, SP 20 Amps. | 37 | Each | 1,700 ₹62,900 | 1,400 ₹51,800 | 1,600 ₹59,200 | 1,321 ₹48,877 | 1,640 ₹60,680 | 2,000 ₹74,000 | 1,600 ₹59,200 |
| 10.00 | Supply & fixing in repair sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail SPN 8 way. | 5 | Each | 1,800 ₹9,000 | 2,500 ₹12,500 | 2,000 ₹10,000 | 1,652 ₹8,260 | 2,125 ₹10,625 | 2,000 ₹10,000 | 1,800 ₹9,000 |
Updated dates
Tender Value
₹35.0 L
EMD Value
₹69,900
Closing Date
2 Jun 2026, 6:00 pmClosed
GE DANAPUR CANTT
GE DANAPUR CANTT
SPL REPAIR/REPLACEMENT OF BER SUMMER APPLIANCES AT GE DANAPUR CANTT
2026_MES_764249_1
CA NO GE/DNR/T-06 of 2026-27
Open Tender
Civil Works
180 days
DANAPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE DANAPUR CANTT
₹69,900
Yes
16 Jun 2026
8 May 2026
5 Jun 2026
8 May 2026
2 Jun 2026
22 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply & Fixing in replacement split type air conditioner of capacity 2.0 TR 4 star rating and EER 3.2 with cordless remote control unit and in built air ioniser ,plasma filter for better indoor air quality, suitable for wall mounted,single phase, 230/250 volt AC including making necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing after commissioning as required at site, making necessary connections and M & L for unplasticised PVC pipes medium duty 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer,testing of AC complete all as specified and directed. | 14 | Each | - | - |
| 2 | Supply & Fixing in replacement split type air conditioner of capacity 1.5 TR 5 star rating and EER 3.2 with cordless remote control unit and in built air ioniser ,plasma filter for better indoor air quality, suitable for wall mounted,single phase, 230/250 volt AC including making necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing after commissioning as required at site, making necessary connections and M & L for unplasticised PVC pipes medium duty 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer,testing of AC complete all as specified and directed. | 23 | Each | - | - |
| 3 | Supply and fixing wall mounting voltage stabilizer for automatic operation single phase naturally air cooled indooor type and designed for input voltage between 130 volt to 280 volts with output voltage stabilized at 230 V +/- 2.5% with time delay relay and suitable for fixing / mounting on wall of capacity 4 KVA copper wound complete all as specified and directed. | 23 | Each | - | - |
| 4 | Supply and fixing wall mounting voltage stabilizer for automatic operation single phase naturally air cooled indooor type and designed for input voltage between 130 volt to 280 volts with output voltage stabilized at 230 V +/- 2.5% with time delay relay and suitable for fixing / mounting on wall of capacity 5 KVA complete all as specified and directed. | 14 | Each | - | - |
| 5 | Supply & fixing factory made,universal bracket / wall mounting stand ,made with galvanized structural steel,high strenth,weather proof,powder coated,modular construction and weight not less than 5 Kg and suitable for upto 2 TR capacity split type AC. | 37 | Each | - | - |
| 6 | S & F copper connection pipe with union at both ends as required (for suction & discharge ) with insulation and PVC insulated FRLS multi strand copper conductor cable of size 4.0 Sqmm three core ( R,B,G) between FCU unit and indoor unit for extension or as required for installation of split AC in any length suitable for 1.5/2 TR Split type AC, making connection & testing complete all as specified. ( Note - One run of suction and one run of discharge pipe with insulation & PVC insulated FRLS multi strand copper conductor cable of size 4.0 Sqmm three core ( R,B,G) will be measured as one unit length | 42 | RM | - | - |
| 7 | M & L in repair for power/sub main wiring with two runs of single core 10 sqmm size and one run of single core 10.0 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed.( Note - two runs of 10 sq mm single core copper conductor and one runs of 10.0 Sq mm copper conductor shall be measured as one unit length.) | 150 | RM | - | - |
| 8 | M & L in repair for power/sub main wiring with two runs of single core 4 sqmm size and one run of single core 4.0 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed. Note : two runs of 4 sqmm single core copper conductor and one runs of 4.0 Sq mm copper conductor shall be measured as one unit length.) | 255 | RM | - | - |
| 9 | Supply & fixing in repair earth plug enclosure (plug and socket ) with and including one MCB, SP 20 Amps. | 37 | Each | - | - |
| 10 | Supply & fixing in repair sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail SPN 8 way. | 5 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Tender9042.pdf
Tender Documents • 0.62 MB
BOQ_856010.xls
BOQ • 7.92 MB
ParticularSpecification9042.pdf
Additional Documents • 0.31 MB
Credit9042.pdf
Additional Documents • 0.05 MB
Download all tender documents and submit your bid