Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC VILL SAROT PALLY PO SANKRAIL DIST HOWRAH PIN 711313 WB | SANKRAIL | HOWRAH | WEST BENGAL | 711313 | L1 | Accepted-AOC BEING L1 BID | |
| 2 | L2₹9.7 L+₹2,680 (0.28%)Rejected-Finance 41 BIDHANGARH SOUTH KOLKATA 700066 | KOLKATA | KOLKATA | WEST BENGAL | 700066 | L2 | Rejected-Finance BEING L2 BID | |
| 3 | L3₹10.7 L+₹1.1 L (11.0%)Rejected-Finance | L3 | Rejected-Finance BEING L3 BID | |
| 4 | L4₹15.9 L+₹6.3 L (64.8%)Rejected-Finance VILL GHARGA PO DWARNARI DIST PURBA BARDHAMAN PIN 713403 WB | PURBA BARDHAMAN | WEST BENGAL | 713403 | L4 | Rejected-Finance BEING L4 BID |
Tender Value
₹12 L
EMD Value
₹50,000
Closing Date
31 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) (CGN) KOLKATA
GE (I) (Coast Guard Navy) Military Engineer Services Damodar Complex Naval Transit Accommodation Hastings, Kolkata700 023
REPAIR AND MAINTENANCE TO INTERNAL FITTINGS, FIXTURES INCLUDING FAN GEYSER ACS, AND CONNECTED ITEM AT DIAMOND HARBOUR UNDER GE (I) (CGN) KOLKATA
2023_MES_606973_1
NIT No 8701/24/2023-2024/03/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
DIAMOND HARBOUR
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GE (I) (CGN) Kolkata
₹50,000
Yes
12 Aug 2023
30 Jun 2023
2 Aug 2023
30 Jun 2023
31 Jul 2023
17 Jul 2023
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Material and labour for concelaed type point wiring including necessary chase cutting of wall for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit and making good the distrubed surfaces as per the existing complete all as specified and as directed. Note: A. Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. B. The Rate of point wiring includes the following :- (i) Copper wire (ii) PVC Conduit with accessoreis (iii) Chase cutting
All as per item No 2 above but for one light point controlled by two 2 -way switches complete all as specified and directed.
All as per item No 2 above but for one three pin socket outlet on same board all complete all as specified and directed.
All as per item No 2 above but for one three pin socket out let 5 amps on independent board complete all as specified and directed.
M & L for concealed type point wiring with 2.5 sqmm (Nominal Area) FRLS PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC conduit medium duty (ISI marked) not less than 20 mm dia with accessories such as bends, cross, elbow, tees etc. of suitable size including continuous earth wire FRLS PVC insulated unsheathed 2.5 Sqmm(nominal area) copper multi-stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly for 16 Amp socket complete all as specified and as directed.
All as per above item No 6 but point wiring with cable size 4Sqmm copper conductor cable complete all as specified and as directed.
M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
All as per item No 8 above but for one light point controlled by two 2 -way switches complete all as specified and directed.
All as per item No 8 above but for one three pin socket outlet on same board all complete all as specified and directed.
All as per item No 8 above but for one three pin socket out let 5 amps on independent board complete all as specified and directed.
M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
All as per above item No 12 but pouint wiring with 4.0 Sqmm copper conductor cable complete all as specified and as directed.
Supply and fixed in repairs switch piano flush type single pole one way 5A SP 230 Volts complete all as specified and as directed.
Supply and fixed in repairs switch piano 5A SP 230 Volts 2 way complete all as specified and as directed.
Supply and fixed in repairs switch socket combination outlet 2 in 1 3/5 pin 5 and 15 Amps flush type complete all as specified and as directed.
Supply and fixed in repairs switch socket combination outlet 2 in 1 3 pin 5 Amps Flush type complete all as specified and as directed.
Supply and fixed in repairs socket outlet 2 in 1, 2/3 pin, 5 Amps Flush type complete all as specified and as directed.
Supply and fixed in repairs Socket outlet 2 in 1, 5/6 pin, 15 Amps Flush type complete all as specified and as directed.
Supply and fixed in repairs ceiling rose PVC surface type 3 terminals complete all as specified and as directed.
Supply and fixed in repairs fan regulator electronic stepped type, 230 volts complete all as specified and as directed.
Supply and fixed in repairs Lamp holder PVC/Polycarbonate type complete all as specified and as directed.
Supply and fixed in repairs call bell, multi music type and connection complete all as specified and as directed.
Supply and fixed in repairs bell push switch piano flush type 5 Amp SP one way complete all as specified and as directed.
Supply and fixed in repairs bell push for calling bell 5 amps flush modular type complete all as specified and as directed.
Supply and fixed in repairs fan regulator step type electronic flush 2 modular type complete all as specified and as directed.
Supply and fixed in repairs modular metal box 1 way all as specified and as directed.
Supply and fixed in repairs modular metal box 2 way complete all as specified and as directed.
Supply and fixed in repairs modular metal box 3 way complete all as specified and as directed.
Supply and fixed in repairs modular metal box 4 way complete all as specified and as directed.
Supply and fixed in repairs modular metal box 6 way complete all as specified and as directed.
Supply and fixed in repairs modular metal box 8 way complete all as specified and as directed.
Supply and fixed in repairs modular white cover plate with frame 1 way complete all as specified and as directed.
Supply and fixed in repairs modular white cover plate with frame 2 way complete all as specified and as directed.
Supply and fixed in repairs modular white cover plate with frame 3 way complete all as specified and as directed.
Supply and fixed in repairs modular white cover plate with frame 4 way complete all as specified and as directed.
Supply and fixed in repairs modular white cover plate with frame 6 way complete all as specified and as directed.
Supply and fixed in repairs modular white cover plate with frame 8 way complete all as specified and as directed.
Supply and fixed in repairs 6 Amps one way single pole switch modular type complete all as specified and as directed.
Supply and fixed in repairs 16 Amps one way single pole switch modular type complete all as specified and as directed.
Supply and fixed in repairs fan regulator step type electronic flush 2 modular type complete all as specified and as directed.
Supply and fixed in repairs switch socket combination 6/16 Amps 5 in one flush modular type complete all as specified and as directed.
Supply and fixed in repairs switch socket combination 3 pin 5 amp' flush modular type complete all as specified and as directed.
Supply and fixed in repairs socket outlet 6A - 2/3 pin combined 2 module, modular type complete all as specified and as directed.
Supply and fixed in repairs socket outlet 6A/16A - 2/3 pin combined 2 module, modular type complete all as specified and as directed.
Supply and fixed in repairs power unit 6 module flush type with starter, DP MCB & Plug top with indicator complete all as specified and as directed.
Supply and fixed in repairs LED Bulb type 12 Watt in warm white/natural white complete all as specified and as directed.
Supply and fixed in repairs LED tube light fittings 20 W Polycarbonate housing, operational voltage of 140 volts to 270 volts, frequency of 50 Hz,lumen efficacy of minimum 110 lumens per watt, integral electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, CRI greater than 80%, CW available CCT of 6500K, power factor of minimum 0.95, life span of minimum 50000 working hours complete all as specified and as directed.
Supply and fixed in repairs LED tube light fittings nominal power 10 Watt LED , LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 110 lumens per watt, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2 KV, protection grade IP 20, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95, Polycarbonate housing, life span of minimum 50000 working hours complete all as specified and as directed.
Supply and fixed in repairs LED surface mounted, glare free uniform illumination with longer life and less maintenance, 18 W with minimum lumen capacity 110 Lum/W complete all all as specified and as directed.
Supply and fixed in repairs LED recessed/surface mounted full open 2 ft x 2 ft tile, glare free uniform illumination with longer life and less maintenance, 24 W with minimum lumen capacity 110 Lum/W complete all as specified and as directed.
Supply and fixed in repairs LED light 35 W made up of pressure die cast housing with IP 66 protection with system efficacy 110 lumen/W for security purpose all as specified and as directed.
Material and labour in repairs for any type sub main wiring with two single core PVC insulated unsheathed , 1100 Volts grade, (FR-LS) copper cable 2 X 4 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 1 X 4 sqmm copper conductor and connected to common earth dolly complete all as specified and as directed . Note :-(i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit. (ii) Quoted rate is incluive of chase cutting, laying of conduit and making good the surface with proper plaster all as directed.
Material and labour in repairs for any type sub main wiring with two single core PVC insulated unsheathed , 1100 Volts grade, (FR-LS) copper cable 2 X 2.5 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 1 X 2.5 sqmm copper conductor and connected to common earth dolly complete all as specified and as directed. Note :-(i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit. (ii) Quoted rate is incluive of chase cutting, laying of conduit and making good the surface with proper plaster all as directed.
Supply and fixed in repairs air circulator fans 1200 mm sweep complete with motor & blades and all required accessories for fixing/hanging, BEE 5 star rating complete all as specified and as directed. Note: Unservicable fan shall be deposited to MES store.
Taking down ceiling fan of any make/model and sweep for ovehauling/ servicing, cleaning and lubricating movable parts with suitable lubricating oil/grease and refixing at site and connection complete from ceiling rose to connector with new flexible cord of suitable size, testing after completion of the work all as specified and as directed. Note : The accessories such as bearing and capacitor will be measured and paid seperately under relevent item.
Supply only capacitor 2.5 mfd suitable for ceiling fan of any make/model and sweep all as specified and as directed .
Supply only Lower and Upper Ball bearing No 6201/6202/6203 suitable for ceiling fan of 1200 mm sweep all as specified and as directed .
Material and labour for preparation of the surface ceilings fan by scaping the old paint and apply one coat of synthetic enamel paint of approved quality and colour with using spray refixing at same/ different location complete all as specified and as directed.
M&L for rewinding of ceiling fan of any make/ model/ sweep including removal of existing burnt winding carefully from slots, cleaning the slots throughly with suitable cleaning agent, applying slot insulation and rewinding with super enamelled copper conductor of same gauge/ same number of turns as that of existing and connecting the coil suitable to operate on 230 V, single phase, AC supply, permanent capacitor type, tying the winding and applying air drying the winding throughly and all as specified and directed.
Taking down exhaust fan of any make/ model and sweep for ovehauling/ servicing, cleaning and lubricating movable parts with suitable lubricating oil/grease and refixing at site at sam/ different location and connection complete from ceiling rose to connector with new flexible chord of copper of suitable size, testing commissioning after completion of the work. Note : The accessories such as bearing and capacitor will be measured as supply only.
Supplu only capacitor 2.5 MFD 230 Volt suitable for exhaust fan of any make/model and sweep all as specified and as directed .
Supply only ball bearing suitable for exhaust fan of any sweep all as specified and as directed .
Material and labour preparation of the old surface exhaust fan and apply one coat of synthetic enamel paint of approved quality and colour by using spray and refixing at same/ different location complete all as specified and as directed.
Supply and fixed in repairs Louver for exhaust fan of existing type all as specified and as directed.
Material and labour for rewinding of exhaust fan of 250/ 300mm including removal of existing burnt winding carefully from slots, cleaning the slots throughly with suitable cleaning agent, applying slot insulation and rewinding with suer enamelled copper conductor of same gauge/same number of turns as that of existing and connecting the coil suitable to operate on 230 V, single phase, AC supply, permanent capacitor type, tying the winding and applying air drying the winding throughly and all as specified and directed.
Supply & fixed in repairs air ventilating equipment heavy duty AC single phase 230/ 240 V of size 300 mm with with bird screen incl connecting up with provision of cable 0.5 sqmm twin core PVC insulated from ceiling rose/connector to fan of including fixing the fan frame to wall opening with suitable size rag bolts after drilling, making hole to wall as per size and making good including louver and shutter complete all as specified and as directed. Note: Old unserviceable fan shall be deposited to store of AGE E/M.
Material and labour in repairs for MCB FP 'B' series 63 Amps complete all as specified and as directed.
Material and labour in repairs for MCB FP 'B' series 40 Amps complete all as specified and as directed.
Material and labour in repairs for MCB FP 'C' series 6-32 Amps complete all as specified and as directed.
Material and labour in repairs for MCB DP 'C' series 6-32 Amps complete all as specified and as directed.
Material and labour in repairs for MCB SP 'C' series 6-32 Amps complete all as specified and as directed.
Material and labour in repairs for sheet steel enclosure 4 way TPN DB with bus bar with provision for TPN MCB as incomer, double door type all as specified and as directed.
Material and labour in repairs for sheet metal DB 12 way double door with bus bar triple pole with neutral complete all as specified and as directed.
Material and labour in repairs for sheet metal DB 8 way double door with 200 Amps rated bus bar single pole with neutral complete all as specified and as directed.
Material and labour in repairs for sheet metal DB 4 way double door with 200 Amps rated bus bar Single pole with neutral complete all as specified and as directed.
Material and labour in repairs for PVC Pole/ Junction box of existing size with suitable size of cable connector and provision of fitting for MCB all complete all as specified and as directed.
Taking down water heater (geyser) 25 ltrs capacity for servicing and scraping, cleaning including brazing of inner vessel of the geyser at leakage point to made it leak proof including testing pressure and assembling of all component refixing complete including supply and fixing of minor spare parts all as specified and as directed.
Supply and fixed in repair heating element 1000-2000 Watt ISI marked for geyser as per existing size with all connecting accessories complete all as specified and as directed.
Supply and fixed in repair thermostat switch of geyser 230V, 30 degree to 90 degree centigrade temp range to be set at 70 degree to 50 degree centigrade suitable for water heater complete all as specified and as directed
Supply and fixed in repair connecting pipe set for geyser of best quality of suitable size and length complete all as specified and directed.
Supply and fixed in repair air release valve 15 mm dia for geyser all as specified and directed.
Supply and fixed in repair Water warmer storage type, electric, capacity 25 litres. BEE 5 star rated complete all as specified and as directed.
Supply and fixed in repair PVC insulated unsheathed three core flexible copper cable of size 2.5 sq mm complete all as specified and as directed
Supply and fixed in repair 15 Amp plug top for geyser complete all as specified and as directed.
Supply and fixed in repair copper inner shell of electric geyser of cap 25 ltr 2 mm thick sheet all as specified and as directed
Servicing of Split/window type AC unit of capacity 1.5/2.0 TR that includes cleaning of air filters, indoor un it grilss & filters through air blower, cleaning of indoor unit body by wiping out dust etc. with wet cloth, cleaning of blower and condensor fan, cleaning of evaporator & condenser coils, graseing/oiling of motors and all moving marts and checking various parts of AC for proper functioning. Note: (i) All major parts or spares as mentioned below will be measured separately. (ii) Charging of gas to be measured separately. (iii) Rate of all minor spares deemed included in the rate.
Supply and charging R-134A / R-410A refrigerant gas complete all as specified and as directed.
Supply and fixed in repair Hermeatically sealed unit of DC compressor for AC of 1.5/2.0 TR capacity including charging gas R-134A/ R-410A complete all as specified and as directed.
Supply and fixed in repair inverter Electronic circuit board as existing type for 1.5 TR/2.0 TR capacity split type AC complete all as specified and as directed.
Supply and fixed in repair display board as existing type for 1.5 TR / 2.0 TR capacity Split / window type AC complete all as specified and as directed.
Supply and fixed in repair capacitor combined type 50 MFD capacity for 1.5 TR / 2.0 TR split/window type AC complete all as specified and as directed.
Supply and fixed in repair running capacitor for 1.5 TR/2.0 TR window/ split type AC as per existing type complete all as specified and as directed.
Supply and fixed in repair capilary tube copper 1.5 TR/2.0 TR window/ split type AC as per existing type complete all as specified and as directed.
Supply and fixed in repair electrical terminal for outer unit PVC/polycarbonate all as specified and as directed.
Supply and fixed in repair blower fan motor for indoor unit 1.5 TR/2.0 TR window/ split type AC as per existing type complete all as specified and as directed.
Supply and fixed in repair outer fan motor for outdoor unit 1.5 TR/2.0 TR window/ split type AC as per existing type complete all as specified and as directed.
Supply and fixed in repair swing motor for indoor unit 1.5 TR/2.0 TR window/ split type AC as per existing type complete all as specified and as directed.
Supply and fixed in repair 3 core copper cable 4.0 sqmm for connection outer to inner unit of split type AC complete all as specified and as directed
Supply and fixed in repair copper tube 3/8" or 5/8" size thickness 0.7 mm for connection to outer to inner unit for 1.5 TR / 2.0 TR capacity split type AC complete all as specified and as directed.
Supply and fixed in repair insulation cover for thermally insulated copper tube for 1.5 TR / 2.0 TR capacity complete all as specified and directed
Supply and fixed in repair medium grade PVC Conduit for drain water of size 15 mm dia complete all as specified and as directed.
Supply and fixed in repair fan blade existing type for window / split type AC complete all as specified and as directed.
Supply only remote for spilit/window type AC as per site/ordered model complete all as specified and as directed by Engr-in-Charge.
Supply and fixed in repairs for filter of existing AC unit any type/ any capacity to any location within the area with testing all as specified and as directed.
Repair/maintenance and fitment of existing water Cooler of 120 ltr capacity with suitable length of UPVC inlet and oulet pipe of suitable dia along with control valv including repair/replacement of spares with proper cleaning of water storage space, cooling coil, supply and charging of refrigerent, maintenance of compressor etc for proper functioning complete all as specified and as directed.
Supply and fixed in repairs single phase Energy meter with LCD display, 5-40A with box, including connection wire and grouting of nut, bolts, complete all as specified and directed.
Repair and maintenance of solar water heater 100 ltrs/exisiting capacity including repairing of water storage, connecting pipe and valve as per existing, solar collector etc with proper cleaning and fitted properly complete all as specified and directed .
Supply and fixed in repairs hermeatically sealed unit of compressor for Water cooler of 120 Ltr capacity including charging gas R-22 complete all as specified and as directed.
Material and labour in repairs mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes for cover plates of valve pit, earth pit, and misc plat forms including Fabricated Structural Mild steel in flat, round or square bars, steel, rolled section such as joist, beam, channel, angle, tee,in available lengths Fe 410-W(Gde-E-250) quality-A in E/M installations complete all as specified and directed .
Supply and fixed in repairs uninterrupted current supply instrument 800 watts single phase , 230 volts 50 Hz complete all as specified and directed.
Supply and fixed in repairs surface PVC box of suitable suitable size for mounting of switches ,sockets ,regulators MCB's etc complete all as Specified and directed.
Supply and fixed in repairs LED under water lights, 9 watts with incl clamps, nuts, bolts, pre wired submersible cable 3 core etc complete all as specified and as directed.
Supply and fixed in repairs machine history sheet / chart /netwrok diagram with details on acrylic sandwich sheet board for display with 6 mm thickness and of suitable size as directed complete with suitable fixing arrangement all as specified and as directed . Note: Subject material to be provided by the department.
SPECIAL CONCRETE AND CONSTRUCTION CO.
HARSH ENGINEERING
HIGH HILLS ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .