Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.4 LAccepted-AOC NO 198 MAHATMA GANDHI ROAD MUTHIALPET PUDUCHERRY 605 003 | PONDICHERRY | PUDUCHERRY | 605003 | 1 | Accepted-AOC L1 Bidder | |
| 2 | 2₹21.1 L+₹2.6 L (14.2%)Rejected-Finance NO 46 PERUMAL KOIL STREET MISSION STREET CUTTING PUDUCHERRY 605 001 | PONDICHERRY | PUDUCHERRY | 605001 | 2 | Rejected-Finance L2 Bidder. Hence rejected | |
| 3 | 3₹41.4 L+₹23.0 L (124.7%)Rejected-Finance | 3 | Rejected-Finance L3 Bidder. Hence rejected | |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
| Sl No | Description | Qty | Unit | MECHELEIN ENGINEERS L2 | Mani Electrical Service L1 | KARTHIK ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply of G.I pipe Ø 125 mm as per the specification. | 70 | Mts | 1,61,000 ₹1,89,980 | 70,000 ₹82,600 Lowest | 84,000 ₹15,96,000 |
| 2.00 | Supply of G.I pipe Ø 80 mm as per the specification. | 180 | Mts | 2,34,000 ₹2,76,120 | 90,000 ₹1,06,200 Lowest | 1,44,000 ₹27,36,000 |
| 3.00 | Supply of street light control box (SMC) with 4 pole connectors and 1 No. 16 A Porcelain Fuse | 36 | Nos. | 54,000 ₹63,720 Lowest | 61,200 ₹72,216 | 28,800 ₹5,47,200 |
| 4.00 | Laying of One run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 4 X 16 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.35 X 0.75 X 1Mts). | 243 | Mts | 1,70,100 ₹2,00,718 | 60,750 ₹71,685 Lowest | 77,760 ₹14,77,440 |
| 5.00 | Laying of One run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 4 X 50 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.35 X 0.75 X 1Mts). | 63 | Mts | 44,100 ₹52,038 | 18,900 ₹22,302 Lowest | 20,160 ₹3,83,040 |
| 6.00 | Laying of One run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 95 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.35 X 0.75 X 1 mt) | 1,202 | Mts | 8,41,400 ₹9,92,852 | 3,60,600 ₹4,25,508 Lowest | 3,84,640 ₹73,08,160 |
| 7.00 | Laying of One run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.35 X 0.75 X 1 mt) | 60 | Mts | 42,000 ₹49,560 | 18,000 ₹21,240 Lowest | 19,200 ₹3,64,800 |
| 8.00 | Laying of Two run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300, 4 X 16 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.55 X 0.75 X 1 mt) | 138 | Mts | 1,10,400 ₹1,30,272 | 48,300 ₹56,994 Lowest | 48,300 ₹9,17,700 |
| 9.00 | Laying of Two run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 95, 4 X 16 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.55 X 0.75 X 1Mts). | 508 | Mts | 4,06,400 ₹4,79,552 | 1,77,800 ₹2,09,804 Lowest | 1,77,800 ₹33,78,200 |
| 10.00 | Laying of Two run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 95, 3½ X 95 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.55 X 0.75 X 1Mts). | 136 | Mts | 1,08,800 ₹1,28,384 | 47,600 ₹56,168 Lowest | 47,600 ₹9,04,400 |
Tender Value
₹17.5 L
EMD Value
₹43,805
Closing Date
19 Sept 2025, 11:00 amClosed
The Superintending Engineer - MP ORs
Electricity Department, No. 137, NSC Bose Salai, Puducherry - 605001
Labour contract for laying of Main cable, Distribution cable, Street light cable and its allied works including supply of certain materials in the Subbiah Nagar area, Thattanchavady, Puducherry
2025_CCPOW_19649_1
No. 01/ED/EE-CTTC/F-40/2025-26
Open Tender
Electrical Works
Works
120 days
Subbiah Nagar, Gorimedu
Please refer to tender documents
3 documents required · 3 mandatory
₹590
Yes
₹43,805
Yes
19 Dec 2025
28 Aug 2025
22 Sept 2025
28 Aug 2025
19 Sept 2025
28 Aug 2025
28 Aug 2025 - 12 Sept 2025
Supply of G.I pipe Ø 125 mm as per the specification.
Supply of G.I pipe Ø 80 mm as per the specification.
Supply of street light control box (SMC) with 4 pole connectors and 1 No. 16 A Porcelain Fuse
Laying of One run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 4 X 16 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.35 X 0.75 X 1Mts).
Laying of One run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 4 X 50 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.35 X 0.75 X 1Mts).
Laying of One run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 95 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.35 X 0.75 X 1 mt)
Laying of One run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.35 X 0.75 X 1 mt)
Laying of Two run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300, 4 X 16 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.55 X 0.75 X 1 mt)
Laying of Two run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 95, 4 X 16 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.55 X 0.75 X 1Mts).
Laying of Two run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 95, 3½ X 95 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.55 X 0.75 X 1Mts).
Laying of Two run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300, 3½ X 95 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.55 X 0.75 X 1Mts).
Laying of two run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300, 3½ X 300 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.55 X 0.75 X 1Mts).
Laying of Three run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300 Sq.mm, 3½ X 95 Sq.mm, 3½ X 95 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.75 X 0.75 X 1Mts).
Laying of Three run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300 Sq.mm, 3½ X 95 Sq.mm, 4 X 16 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.75 X 0.75 X 1Mts).
Laying of Three run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 95, 3½ X 95, 3½ X 95 Sq.mm cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.75 X 0.75 X 1Mts).
Laying of Four run of PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300, 3½ X 95, 3½ X 95, 3½ X 95 Sq.mm including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.95 X 0.75 X 1Mts).
Laying of Four run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300 Sq.mm, 3½ X 300 Sq.mm, 3½ X 95 Sq.mm, 4 X 16 Sq.mm, cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.95 X 0.75 X 1 mt).
Laying of Four run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300 Sq.mm, 3½ X 300 Sq.mm, 3½ X 95 Sq.mm, 3½ X 95 Sq.mm, cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.95 X 0.75 X 1 mt).
Laying of Four run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 95 Sq.mm, 3½ X 95 Sq.mm, 3½ X 95 Sq.mm, 3½ X 95 Sq.mm, cable direct in ground including excavation of cement concrete road, sand cushioning, brick protective covering and refilling the trench etc., as required (0.95 X 0.75 X 1 mt).
Laying of One run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300 Sq.mm in 125 mm dia metal pipe including excavation of all types, along/across the road up to 30 cm depth and refilling the trench as required (0.35 X 0.75 X 1 mt).
Laying of One run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 95 Sq.mm in 80 mm dia metal pipe including excavation of all types, along/across the road up to 30 cm depth and refilling the trench as required (0.35 X 0.75 X 1 mt).
Laying of One run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 4 X 50 Sq.mm in 80 mm dia metal pipe including excavation of all types, along/across the road up to 30 cm depth and refilling the trench as required (0.35 X 0.75 X 1 mt).
Laying of One run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 4 X 16 Sq.mm in 50 mm dia metal pipe including excavation of all types, along/across the road up to 30 cm depth and refilling the trench as required (0.35 X 0.75 X 1 mt).
Laying of Two run of PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade ISI standard of size 3½ X 95 Sq.mm, 3½ X 95 Sq.mm in 80mm dia metal pipe including excavation of all types, along/across the road up to 30 cm depth and refilling the trench as required (0.55 X 0.75 X 1 mt).
Laying of Two run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300 Sq.mm, 4x16 Sq.mm in 125 mm, 50 mm dia metal pipe including excavation of all types, along/across the road up to 30 cm depth and refilling the trench as required (0.55 X 0.75 X 1 mt).
Laying of Two run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300 Sq.mm, 3½ X 95 Sq.mm in 125 mm, 80 mm dia metal pipe including excavation of all types, along/across the road up to 30 cm depth and refilling the trench as required (0.55 X 0.75 X 1 mt).
Laying of Three run of PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade ISI standard of size 3½ X 95 Sq.mm, 3½ X 95 Sq.mm, 3½ X 95 Sq.mm in 80 mm dia metal pipe including excavation of all types, along/across the road up to 30 cm depth and refilling the trench as required (0.75 X 0.75 X 1 mt).
Laying of Three run of PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300 Sq.mm, 3½ X 95 Sq.mm 4x16 sq.mm in 125 mm, 80 mm, 50mm dia metal pipe including excavation of all types, along/across the road up to 30 cm depth and refilling the trench as required (0.75 X 0.75 X 1 mt).
Laying of Four run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size3½ X 95 Sq.mm, 3½ X 95 Sq.mm, 3½ X 95 Sq.mm 3½ X 95 sq.mm in 80 mm dia metal pipe including excavation of all types, along/across the road up to 30 cm depth and refilling the trench as required (0.95 X 0.7 X 1 mt).
Laying of Four run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 95 Sq.mm, 3½ X 95 Sq.mm, 3½ X 95 Sq.mm 4x16 sq.mm in 80 mm, 50 mm dia metal pipe including excavation of all types, along/across the road up to 30 cm depth and refilling the trench as required (0.95 X 0.75 X 1 mt).
Laying of Four run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300 Sq.mm, 3½ X 95 Sq.mm 4x50 sq.mm, 4x16 sq.mm in 125 mm, 80 mm, 50 mm dia metal pipe including excavation of all types, along/across the road up to 30 cm depth and refilling the trench as required (0.95 X 0.75 X 1 mt).
Laying of Five run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size 3½ X 300 Sq.mm, 3½ X 95 Sq.mm, 3½ X 95 Sq.mm, 3½ X 95 Sq.mm, 3½ X 95 Sq.mm in 125 mm, 80 mm dia metal pipe including excavation of all types, along/across the road up to 30 cm depth and refilling the trench as required (1.15 X 0.75 X 1 mt).
Laying of One run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size exceeding 125 Sq.mm not exceeding 3 ½ X 300 Sq.mm cable in open space/under ground (end loose and termination)
Laying of One run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size exceeding 4x25 sq.mm not exceeding 125 Sq.mm cable in open space/under ground (end loose and termination)
Laying of One run of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade ISI standard of size exceeding 2x10 sq.mm not exceeding 4x25 Sq.mm cable in open space/under ground (end loose and termination)
Construction of pillar box plinth for erection of 6 Way 600 Amps SS Pillar and 8 Way 400 Amps Distribution Pillar along with erection of the Distribution Pillar including required concrete materials, refilling under floor of pillar plinth with river sand, removal of excess earth and as per the direction of the Engineer - in - charge
Earthing of SS/Distribution pillar box
Carriage of GI Pipe and LT UG cable laying involving crane including loading, unloading and stocking at site as per the direction of engineer-in-charge.
Transport charges for materials
MECHELEIN ENGINEERS (BID ID -63755)
KARTHIK ENTERPRISES (BID ID -63770)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_20001.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .