| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹29.2 L+₹28,670 (0.99%)Rejected-Finance 14 10 4TH MAIN 8TH C CROSS SRINIVASA NAGAR BSK 3RD STAGE BENGALURU 560085 | BENGALURU URBAN | KARNATAKA | 560085 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹32.1 L+₹3.2 L (11.1%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹32.5 L+₹3.6 L (12.4%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹32.6 L+₹3.7 L (12.7%)Rejected-Finance 6 A FIRST MAIN NEAR JAMIYA MASJID ISLAMPUR ANNASANDRAPALAYA HAL VIMANAPURA POST BANGALORE 560 017 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560017 | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
20 Sept 2022, 6:00 pmClosed
Garrison Engineer Central Bangalore
Military Engineer Services Garrison Engineer Central Agram Post Bangalore PIN- 560007
WELCOME MAINTENANCE TO MARRIED ACCOMMODATION AT NGV INCLUDING REPAIR AND REPLACEMENT OF INTERNAL ELECTRIFICATION ITEMS/WORKS AT VARIOUS OFFICERS MD ACCOMMODATION UNDER GE (CENTRAL) BANGALORE
2022_MES_546893_1
8215E
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Central Bangalore
Please Refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Central Bangalore
₹72,000
Yes
30 Sept 2022
22 Aug 2022
22 Sept 2022
22 Aug 2022
20 Sept 2022
7 Sept 2022
22 Aug 2022 - 3 Sept 2022
Amount
B/R PORTION : - Taking down cement plaster on brick/concrete block or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing debris outside MD land complete all as specified and directed
M & L Rendering 15mm thick on faces of stone masonry in CM 1:6 surface finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces as in ceilings (sunshed, chajja, fins etc) and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of primer over wall care putty (Twocoats of minimum 1 mm thick ) complete all as specified and directed.
M & L for preparing newly plastered surfaces of ceilings and applying two coats of distemper oil emulsion over a coat of primer over wall care putty (Twocoats of minimum 1 mm thick ) complete all as specified and directed.
M & L Preparation of Old decorated surface and applying one coat of distemper oil bound on surface of Walls complete all as specified and as directed.
M & L Preparation of Old decorated surface and applying one coat of distemper oil bound on surface of ceilings complete all as specified and as directed.
M&L complete removal of existing treatment on Walls and applying two coats of distemper oil emulsion over a coat of primer to plastered and other surfaces including providing wall care putty two coats in minimum 1mm thick on plastered surface complete all as specified.
M&L complete removal of existing treatment on ceilings and applying two coats of distemper oil emulsion over a coat of primer to plastered and other surfaces including providing wall care putty two coats in minimum 1mm thick on plastered surface complete all as specified.
M & L Preparation of old wooden surface of any description and applying one coat of synthetic enamel paint over 10cm width or girth complete all as specified and as directed.
M & L Preparation of old steel surface of any description and applying one coat of synthetic enamel paint over 10cm width or girth complete all as specified and as directed.
M & L for preparation of old treated surfaces of walls and applying one coat of white wash complete all as specified and directed.
M & L for preparation of old treated surfaces of ceilings and applying one coat of white wash complete all as specified and directed.
Grinding of Existing Mosaic Floor Surface with admixture as directed in any floor & descripition after complete removal of strains, greasy spots etc washing with caustic soda & finally wax polished with machine complete all as directed by Engineer-in-Charge. Note :- ( i ) The Grinding & Polishing work is to be caried out upto Seven Floors & Further Floors Surface including Skirting, Staircase Treads & Risers etc. ( ii ) Floor for Grinding & Polishing will not be given in full the same will be in part any number of times as ordered as such contractor to make arrangment of grinding & polishing machine as & when required, no claim what so ever will be entertained for work being carried out in piece meal. ( iii ) Quoted Rate is deeamed to be inclusive for above.
Cleaning of Existing ceramic tiles in flooring / wall with acid of suitable concentration, so that the tile joints not damaged and filling the tile joints with white cement mixed with pigments including junction of wall and floor and gratings, doorframe etc and finally cleaning with dry cloth the entire area including water supply / sanitary fiitings for entire satisfaction of Engr- in - charge.
E/M PORTION : - Taking down copper/ aluminium point wiring(light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc complete.
Re-wiring with PVC insulated and unsheathed FRLS cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in existing conduit concealed in wall/roof including replacement/provision of new MS terminal boxes fixed flush with wall surface with 3mm thick laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core (FRLS) PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for :- One light point controlled by one 5 Amps switch one way
All same as item No 17 above but one fan point controlled by one 5 Amps switch one way.
All same as item No 17 above but one light point controlled by two way switch 5 Apms
All same as item No 17 above but one call bell point controlled by one 5 Amps switch one way.
All same as item No 17 above but one 3 pin socket point 5 Amp on independent board.
All same as item No 17 above but one 3 pin socket point 5 Amp on same board with other switches.
All as per item No. 17 above but with 2.5 sqmm (Nominal area) (FRLS) cable with 2.5 Sqmm size copper earth continuity conductor (FRLS) for 3 pin 15 A socket outlet on independent board complete all as specified and directed.
Supply and fix Switch piano, flush button single pole, 5 Amps one way. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix Switch piano, flush button single pole, 5 Amps Two way. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC blocks. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix modular type sokcet combination flush type 5 /10 Amp 2/3 pin muliti purpose, 2 module. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix modular type sokcet combination flush type 16 Amp 2/3 pin muliti purpose, 2 module. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix in repair modular switch 1 way 6/10A,1 module. Make : Legrand/Standard/Cabtree
Supply and fix in repair modular switch 1 way 16/10A,1 module. Make : Legrand/Standard/Cabtree
Supply and fix in repair white cover plate with frame 1 module Make : Legrand/Standard/Cabtree
Supply and fix in repair white cover plate with frame 2 module Make : Legrand/Standard/Cabtree
Supply and fix in repair white cover plate with frame 3 module Make : Legrand/Standard/Cabtree
Supply and fix in repair modular type metal box 1 module Make:Legrand/Standard/Cabtree
Supply and fix in repair modular type metal box 2 module Make : Legrand/Standard/Cabtree
Supply and fix in repair modular type metal box 3 module Make : Legrand/Standard/Cabtree
Supply and fix in repair modular type metal box 4 module Make : Legrand/Standard/Cabtree
Supply and fix in repair modular type metal box 5 module Make : Legrand/Standard/Cabtree
Supply and fix in repair modular type metal box 6 module Make : Legrand/Standard/Cabtree
Supply and fix in repair modular type metal box 8 module Make : Legrand/Standard/Cabtree
Supply and fix modular switch 5/10 Amps two way, 1 module. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix modular type bell push, single pole, 5/10 Amps one way 1 module. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix in repair Door bell electronic, music type, 230 volt AC. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix in repair modular type Fan regulator electronic, 2 module, step & socket type upto 300 watts 230 volt, AC suitable for 1200/1400mm sweep ceiling fan. Make : Anchor/Cabtree/Legrand/Standard
S&F in replacement ULTRA SLIM square profile E-lite LED pride plus neo tube light fitting of make Havells, 9/10 watts 6500K , 230 volt, with polycarbonate channel environmental freindly, energy efficiency complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Havells Cat No LHEXACP7IN1W010 OR equivelant of make Shakti/Crompton Greaves/Bajaj
S&F in replacement Pride plus inverter batten of make Havells, LED tube light fitting of 20 watts 6500K , 230 volt, with polycarbonate channel , lithium Ion battery with charging time 8-10 hours and back up time 4 hours complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Havells Cat No LHEXACP7FN1W020 OR equivelant of make Shakti/Crompton Greaves/Bajaj
S&F in replacement new generation energy saving environmental friendly long life, with high power LED building street light/security light 1x 25 Watt LED pressure die-cast aluminium, heat resistant, toughened glass diffuser, IP65/66 protection and impact resistant of IK7 prewired with all accessories and connection up with 3 core flexible copper conductor cable 4/20 mm size, 1.5m long and testing on installation all as specified and directed. Make Havells Cat No ENDURAPEARLSL25WLED757SASYTOPCMP or equivelent of Bajaj/phillips/CG
S&F in replacement security light bracket made out of 25 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flate iron clamp of size 50mm X 6 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole including painting of mild steel flate iron surface with two coats of synthetic enamel paint over a coat of red oxide primer complete including taking down unserviceable one all as specified and directed.
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 4 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 12 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
Supply and fix in replacement MCB single pole 6 to 32 Amps 240 volts, C series, 10 kA rupturing capacity
Supply and fix in replacement MCB single pole and neutral, 6 to 32 Amps 240 volts, C series, 10 kA rupturing capacity
Supply and fix in replacement MCB single pole & neutral 40 Amps 240 volts, C series,10 kA rupturing capacity
Supply and fix in replacement MCB single pole & neutral 100 Amps 240 volts, C series,10 kA rupturing capacity
Supply and fix in replacement MCCB four pole 400 Amps 415 volts, 36 KA rupturing capacity
Supply and fix in replacement MCB Triple pole & neutral 16 to 32 Amps 415 volts, C series, 10 kA rupturing capacity providing in DB complete all as specified.
Supply and fix in replacement Sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed cable FRLS) conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in new non metallic PVC grey conduit (medium grade) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. NOTE:- Two run of wiring cable, one run of earth wire and one run of PVC conduit shall be measured as one unit RM
Supply and fix in replacement Sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed cable (FRLS) conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in new non metallic PVC grey conduit (medium grade) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. NOTE:- Two run of wiring cable, one run of earth wire and one run of PVC conduit shall be measured as one unit RM. NOTE:- Two run of wiring cable, one run of earth wire and one run of PVC conduit shall be measured as one unit RM
Cutting chases in PCC/brick work, cutting not exc 10 cm girth, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good with cement mortar, complete all as specified and directed.
Taking down of storage water heater (Geyser) of any size 50/35/25 ltrs capacity from existing position by disconnecting from water supply pipe line and electric connection mains carryout necessary repairs by replacing GI fittings, NRV, pressure release valve, brazing etc reconnecting with all fittings and acessories like heating elements, thermostat, indicator lamps including two coats of painting and refixing on same position after repair and making electric/water connections complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of 600 mm long PVC connection pipe, braided type, for HOT & COLD water supply with chromium plated brass screwed nuts at bolt ends with washers for making water connections for storage water heater(Geyser) to GI pipe 15mm complete as directed .
Taking down ceiling/exhaust fan dismantling and painting of ceiling/exhaust fan complete at site with synthetic enamel paint by spraying incl (fittings with filler) one coat after cleaning all dust etc incl connecting up. Provn of twin core cable of suitable size for ceiling rose to connector connecting of earth wire incl replacement of fan capacitor 2.5/3.15 MFD,canopy, bearing/bush, rubber bushes minor nuts bolts screws washers greassing in fan bearing & refix same complete all as directed
Rewinding of ceiling fan with appropriate size of copper enamelled wire including varnishing ,heating with proper insulation complete and testing all as specified and directed .
Rewinding of exhaust fan with appropriate size of copper enamelled wire including varnishing ,heating with proper insulation complete and testing all as specified and directed .
M&L, for taking down old unserviceable earthing and providing new Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground (earth pit depth not less than 2.25m deep below the ground level) with top edge of earth plate at a depth not less than 1.5m below ground level connected to earth using GI earth wire of 4mm dia by means of of nuts, bolts and washer and check nuts of GI or steel as shown in electrical plate No.3 of MES SSR-2009 (Part-I) and connected to earth test point all as specified or indicated including testing on completion with and including 15mm bore light grade GI protection pipe 7.5 metre long for earth including PCC (1:2:4) pit with RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hooks made out of 6mm dia MS bars, watering arrangement with 20mm dia light grade pipe, funnel, wire mesh, common salt chorcoal, necessary excavation and earth work in any type of soil complete all as specified.
Kavitha Constructions
Omkar Constructions
YUVARAJ ELECTRIC AND CO
MAA ENGINEERING SERVICERS
RK Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .