| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹60.5 LAccepted-AOC | 1 | Accepted-AOC lowest | |
| 2 | 2₹74.1 L+₹13.6 L (22.5%)Rejected-AOC | 2 | Rejected-AOC higher rates | |
| 3 | 3₹1.0 Cr+₹39.7 L (65.7%)Rejected-AOC 11 7 PARMAL COLONY LAKKARPUR RAILWAY CROSSING LAKKARPUR FARIDABAD FARIDABAD HARYANA 121003 UDYAM DL 09 0001967 06AABCI9677H1Z6 R M MSME STATUS AS VERIFIED | FARIDABAD | HARYANA | 121003 | 3 | Rejected-AOC higher rates | |
| 4 | Rejected-Technical | - | Rejected-Technical Disqualified as the firm has not deposited EMD Amount as per PQR of e-NIT. | |
| 5 | Rejected-Technical 2 KALKAJI INDUSTRIAL AREA KALKAJI KALKAJI SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | - | Rejected-Technical Disqualified as the HEW Portal Login ID / Certificate was created after the opening of Part 1 of the tender. |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
20 Aug 2024, 1:00 pmClosed
RAKESH HARSH
CE RGTPP Khedar Hisar
Thermal Insulation works pertaining to Boiler and its auxiliaries and Thermal Insulation works on Turbine and its auxiliaries during forthcoming overhauling of unit 1 of 2x600 MW, RGTPP, Hisar
2024_HBC_389376_1
20246D3DB42C 20AF 4E54 85E8 F5151ACD6767712PGC
Open Tender
Civil Works
Works
90 days
KHEDAR
as per attached tender documents
3 documents required · 3 mandatory
₹1,180
₹1.3 L
Yes
4 Dec 2024
12 Jul 2024
22 Aug 2024
12 Jul 2024
20 Aug 2024
12 Jul 2024
Amount
Thermal Insulation works pertaining to Boiler and its auxiliaries
Providing new Insulation with refixing of old cladding in Boiler Furnace Area. Insulation (Type: Rock Wool Felt, Thickness-200mm) Netting: GI, Cladding (Old Corrugated sheet)
Providing new Insulation with new cladding in Boiler Furnace Area. Insulation (Type: Rock Wool Felt, Thickness-200mm) Netting: GI, Cladding (Corrugated Al. Sheet, Thickness: 1.2 mm)
Providing New Insulation with refixing of old cladding in Boiler Furnace Wind Box and APH Area. Insulation (Type: Rock Wool Felt, Thickness-200mm) Netting: GI, Cladding (Old Corrugated sheet)
Providing New Insulation with New Cladding in Boiler Furnace Wind Box and APH Area. Insulation (Type: Rock Wool Felt, Thickness-190 mm) Netting: GI, Cladding (Corrugated Al. Sheet, Thickness: 1.2 mm)
Providing New Insulation with refixing of old cladding in Drum DownComers pipers 24 to 80 m elevation, ring header including man holes of ring header at 9 meter elevation, main steam to PRDS line, main steam line and ID fan area. Insulation (Type: Rock Wool Felt, Thickness-150 mm) Netting: GI, Cladding (Old plain sheet)
Providing New Insulation with new cladding in Drum Down-Comers pipers 24 to 80 m elevation, ring header including man holes of ring header at 9 meter elevation, main steam to PRDS line, main steam line and ID fan area. Insulation (Type: Rock Wool Felt, Thickness-150 mm) Netting: GI, Cladding (Al. Sheet, Thickness: 0.56 mm)
Providing New Insulation with refixing of old Cladding in Bottom of Zpanel at 9 meter elevation and ESP Hopper area. Insulation (Type: Rock Wool Felt, Thickness-150 mm) Netting: GI, Cladding (Old Corrugated sheet)
Providing New Insulation with new cladding in Bottom of Z-panel at 9 meter elevation and ESP Hopper area. Insulation (Type: Rock Wool Felt, Thickness-190 mm) Netting: GI, Cladding (Corrugated Al. Sheet, Thickness: 1.2 mm)
Providing New Insulation with new cladding in Fuel Oil Lines/after Vent/Drain line valve i.e. Drum Vent, CBD Drain (Left and Right) and Vent, LTSH Drain line and Ring Header Drain Valve area. Insulation (Type: Rock Wool Felt, Thickness-50 mm) Netting: GI, Cladding (Al. Sheet, Thickness: 0.56 mm)
Filling Inside Cover Plates. Providing only new Insulation in Burner Panel area. Insulation (Type: Rock Wool Felt, Thickness-120 mm) Netting: GI.
Providing New Insulation with New Cladding in Vent/Drain i.e. Drum Vent, CBD Drain (Left and Right), SH Spray Line and Vent, LTSH Drain line and Ring Header Drain Valve area. Insulation (Type: Rock Wool Felt, Thickness-100 mm) Netting: GI. Cladding (Al. Sheet, Thickness: 0.56 mm)
Providing New Insulation with New Cladding in Primary and secondary Hot Air Duct at, 6 M to 30 M elevation area. Insulation (Type: Rock Wool Felt, Thickness-170 mm) Netting: GI. Cladding (Corrugated Al. Sheet Thickness: 1.2 mm)
Providing New Insulation with refixing of old cladding in Primary and secondary Hot Air Duct at , 6 M to 30 M elevation area. Insulation (Type: Rock Wool Felt, Thickness-170 mm) Netting: GI. Cladding (Old Corrugated Sheet)
Providing New Insulation with New Cladding in Flue Gas Duct area. Insulation (Type: Rock Wool Felt, Thickness-40 mm) Netting: GI. Cladding (Corrugated Al. Sheet Thickness-1.2 mm )
Providing New Insulation with refixing of old cladding in Flue Gas Duct area. Insulation (Type: Rock Wool Felt, Thickness-40 mm) Netting: GI. Cladding (Old Corrugated Sheet)
Providing New Cladding sheet on existing insulation in any area boiler/ hot duct/cold duct/wind box/ ESP hopper /ESP duct. Cladding (Corrugated Sheet Al Thickness: 1.2 mm)
Providing New Cladding sheet on existing insulation in Any area line of vent/drain/main steam line/ bottom Ring Header line. Cladding (Al. Sheet Thickness: 0.56 mm)
Refixing of Old cladding Sheet in any of the area pertaining to Boiler and its auxiliaries. Cladding (Old Corrugated/ plain sheet)
Thermal Insulation works pertaining to Turbine and its auxiliaries
Alumina silicate fibre block insulation with bottom plaster, Thickness: 70x3mm, Area: HIP turbine (Cylinder cover) Main Turbine Site.
Alumina silicate fibre block type insulation with bottom plaster, Thickness: 60x3mm, Area: HIP turbine (Cylinder base) Main Turbine Site
Alumina silicate fibre type insulation , Thickness: 80x2mm, Area: steam inlet sleeve, HIP turbine Main Turbine Site
Alumina silicate fibre type, Thickness: 40x2mm, Area: Dum Ring balance piping, HIP turbine Main Turbine Site.
Alumina silicate fibre block type insulation with bottom plaster, Thickness: 80x2mm, Area: MSV body Main Turbine Site
Alumina silicate fibre pipe type insulation with bottom plaster, Thickness: F340x70 and F480x50, Area: GV piping and flanges Main Turbine Site
Alumina silicate fibre block type insulation with bottom plaster, Thickness: 80x2mm, Area: RSV and RIV body and cover Main Turbine Site
Alumina silicate fibre pipe type insulation with bottom plaster, Thickness: 80x2mm, Area: RSV piping and flanges Main Turbine Site
Alumina silicate fibre block type insulation, Thickness: 60 +40mm, Area: cross-over piping and flanges Main Turbine Site
Alumina silicate Felt, Insulation Thickness-160 mm for TDBFP in r/o TGM-I, RGTPP
Alumina silicate Felt ,Thickness 120 mm in r/o TGM-I, RGTPP
Alumina silicate Felt ,Thickness 100 mm in r/o TGM-I, RGTPP
Alumina silicate Felt ,Thickness 50 mm in r/o TGM-I, RGTPP
Rock Wool felt ,Insulation Thickness 160 mm in r/o TGM-I, RGTPP
Rock Wool felt ,Insulation Thickness120 mm in r/o TGM-I, RGTPP
Rock Wool felt,Insulation Thickness 100 mm in r/o TGM-I, RGTPP
Rock Wool felt ,Insulation Thickness 80 mm in r/o TGM-I, RGTPP
Rock Wool felt , Insulation Thickness 50 mm in r/o TGM-I, RGTPP
Cladding in r/o TGM-I, RGTPP
Adarsh Insulations (BID ID -1137019)
INDO STAR INSULATION PRIVATE LIMITED (BID ID -1130801)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .