Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹14.8 LAdmitted-Finance | -4.00% | ₹14.8 L | L1 | Admitted-Finance |
| 2 | L2₹15.4 LAdmitted-Finance | +0.00% | ₹15.4 L | L2 | Admitted-Finance |
| 3 | L3₹15.7 LAdmitted-Finance | +2.10% | ₹15.7 L | L3 | Admitted-Finance |
| 4 | L4₹16.0 LAdmitted-Finance MU GHOTA PO POGAT TA MANGRULPIR DIST WASHIM MAHARASHTRA | MANGRULPIR | WASHIM | MAHARASHTRA | +3.80% | ₹16.0 L | L4 | Admitted-Finance |
Tender Value
₹15.4 L
EMD Value
₹15,393
Closing Date
16 Jan 2026, 5:00 pmClosed
Add CEO Z P Washim
Zilla Parishad Washim
Construction Of Bhakta Niwas For Sant Gajanan Maharaj Sansthan at Tamsi Tq. Washim Dist Washim
2026_WASHI_1267118_2
ZPWASHIM/WORKS/Tender NIT No.16/2025-2026/1stcall
Open Tender
Civil Works
30 days
WASHIM
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,180
₹15,393
Works Division z p Washim
16 Jun 2026
8 Jan 2026
19 Jan 2026
8 Jan 2026
16 Jan 2026
8 Jan 2026
12 Jan 2026
Construction Of Bhakta Niwas For Sant Gajanan Maharaj Sansthan at Tamsi Tq. Washim Dist Washim
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means [Bd.A.1 P.No. 259] (S.S.R. I.No. 21.02)
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation & necessary back filling, ramming, watering including shoring & strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means [Bd.A.2 P.No. 259] (S.S.R. I.No. 21.06)
Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical Means [Bd.A.2 P.No. 259] (S.S.R. I.No. 21.08)
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. [As directed by Engineer in charge.] (S.S.R. I.No. 21.40)
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) [Bd. E. 1 P.No. 287] (S.S.R.I.No. 24.01)
Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) [Bd.F.3 P.No. 298 and B.7, P.No.38] (S.S.R.I.No. 25.11)
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) [Bd.F.5 Page No. 300 and B.7, Page.No. 38] (S.S.R.I.No. 25.31)
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) [Bd.F.6/Page No.300/I.S. 456 (2000)]
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. [Bd.A.11 P.No.263 ] (S.S.R. I.No. 21.37)
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete [Spec.No. :Bd.G.5 Page No. 315] (S.S.R.I.No. 27.05)
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete [Spec.No. :Bd.G.5 Page No. 315] (S.S.R.I.No. 27.05)
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/granite/quartzite/gneiss metal for R.C.C. slabs and landings as per detailed designs & drawings including steel centering formwork cover blocks laying/pumping compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth & even surface or roughening if special finish is to be provided & curing etc. complete,(Excluding reinforcement & structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc complete With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) [BdF8 P.No. 302 & B7 P.No.38] (S.S.R.I.No. 25.70)
Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) [Bd.F.9 Page No. 303 and B.7, Page No.38] (S.S.R.I.No. 26.05)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Bd.F.17, Page No. 306
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Bd.L.7 Page No. 369 (SSR I.No. 32.11)
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Bd. L.2 Page No. 368
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. [As directed by Engineer in charge.] (S.S.R.I.No. 32.34)
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. [As directed by Engineer in charge.] (S.S.R.I.No. 35.25)
Providing and applying plastic emulsion paint of approved quality, colour and shade to new surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. [Bd.P.6 Page No. 414 ] (S.S.R.I.No. 36.14)
Providing and laying Rough Shahabad Stone Flooring 25mm to 30mm thick and of required width in plain/ diamond pattern on a bed of 1:6 C.M. including cement float, striking joints, pointing in cement mortar 1:3 curing and cleaning etc. complete. [Bd.M.1 Page No. 379] (S.S.R.I.No. 33.01)
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. [Bd.U.1 Page No. 537] (S.S.R.I.No. 40.01)
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating without box [As directed by Engineer in charge.] (S.S.R.I.No. 39.44)
Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kg/Smt. [Bd.W.6 Page No.585] (S.S.R.I.No. 44.10)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.76 MB
BOQ_2182946.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid