Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance NO 15 PULAVAR GOVINDAN STREET GANDHI NAGAR AVADI CHENNAI 600 054 | AVADI | CHENNAI | TAMIL NADU | 600054 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance NO 4 SRIRAMULU VILLA MULLAI STREET KANDAN NAGAR TIRUTTANI 631209 | TIRUTTANI | THIRUVALLUR | TAMIL NADU | 631209 | Admitted-Finance |
| 5 | Admitted-Finance NO 6 1 ALAGAR PERUMAL KOIL MAIN STREET VADAPALANI CHENNAI 600 026 | CHENNAI | CHENNAI | TAMIL NADU | 600026 | Admitted-Finance |
Tender Value
₹8.4 L
EMD Value
₹16,900
Closing Date
9 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I RD AVADI
AGE I RD AVADI, AVADI CHENNAI 600054
PROVISION OF POWER SUPPLY BACKUP TO MI ROOM IN TECHNICAL AREA AT CVRDE AVADI
2022_MES_506141_2
8468/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AVADI
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹16,900
Yes
18 May 2022
18 Apr 2022
11 May 2022
18 Apr 2022
9 May 2022
25 Apr 2022
18 Apr 2022 - 25 Apr 2022
60 days
Amount
Excavation in trenches in Hard / dense soil not exceeding 1.5 meter wide and not exc 1.5 m depth for taking out / laying of UG cables and getting out all as specified and directed.
Returning filling, including spreading leveling, watering and well ramming in layers not exc 25 cms thick of soil complete all as specified and directed.
Removing the surplus excavated material/soil to a distance not exc 50 miters and depositing, where directed at a level not exceeding 1.5 meters above the starting point all as specified and directed.
Dry river sand cushioning / sand covering for underground cable protection complete all as specified. Note : Punned down thickness only shall be measured complete all as specified and directed
Supply and laying old size brick, size 230x115x75mm burnt clay building brick sub class (B) for protecting LT U/G cable complete.
M&L double Wall Corrugated (DWC) pipe 90mm outer diameter size conforming to IS 16205 Part 24 round shape with necessary fitting complete as per site requirment laid in trenches / floor for UG cable protection complete all as specified and directed.
Cutting of road to a width of 30cm and depth not exceeding 90cm for laying of protection pipe / cable including returning and filling, spreading levelling, watering and well ramming in layers and making good with PCC 1:2:4 type B1 for top 100mm thick complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth strip lead 32 x 6 mm size not more than 7.5meter length connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, including provision of GI earth strip protected by 40 mm dia GI pipe 'light grade not more than 7.5meter length and watering pipe 20 mm dia GI 'medium grade and GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, including provision PCC chamber, cast iron frame with cover 10mm thick hinged, lifting hook shall be suitably embedded in the PCC/masonry enclosure, finished flush with Ground level including all necessary excavation & earth work, earth strip connected to main test point length not more than 7.5m, including provision of test point terminal, testing earthing after completion all as per dimension ,specification shown in electric plate No 3 of MES SSR Part-I 2009 all as specifed as directed.
M & L for MCCB 4P, 200Amps, 415V, 36 KA breaking capacity with fixed thermal magnetic release including sheet metal enclosure (2mm thick CRCA Sheet) for MCCB flushed on wall surface duly powder coated and connection complete all as specified and directed.
Supply and lay cable XLPE insulated PVC Bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 V grade with stranded aluminium conductor of size 120 Sqmm 3.5 Core complete with suitable lugs, glands complete all as specifed and directed.
Supply and lay cable XLPE insulated PVC Bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 V grade with stranded aluminium conductor of size 50 Sqmm 3.5 Core with suitable lugs, glands complete all as specifed and directed.
Supply, install, commissioning & testing LT panel outdoor type factory made out of 3mm thick CRCA steel double door weather/ dust/ vermin proof, IP 65 protection, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one No lock with duplicate key duly painted with power coated paint including connection of all incoming and outgoing cables using suitable size lugs and glands, danger notice board, panel to be mounted on PCC block/brick pillar complete in all respect all as specified & directed by EIC including comprising of following items :- (i) BUS BAR: High conductivity aluminium alloy, 3 Nos for phase (R,Y,B) rating 240 amp rating and 1 No for neutral rating 120 amp, mounted on DMC support with heat shrink sleeve - 01 set. (ii) INCOMER : MCCB 160 Amps, 4 Pole, 25KA fixed thermal magnetic release - 1 Nos. (iii) Outgoing: MCCB 63 Amp 4 Pole 16KA fixed thermal magnetic release -03 Nos. (iv) Digital multifunction meter with suitable CT's complete. (v) On load change over switch 160 Amps, 4 Pole. (vi) Voltmeter for three phase, digital type suitable 415V 3 phase 50Hz with Indication lamp (R,Y,B), LED type, with toggle switches set of 3 complete.
Supply and laying GI tubing “light Grade” 80 mm dia bore in trenches / under floors / road crossing for protection of cables duly sealed at both ends after drawing cable complete all as specified and as directed.
SREE VENKATESWARAS CONSTRUCTIONS
Veera Electrical
EASHWAR ELECTRICALS
CHARAN ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .