Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-AOC 29 GANDHI NAGAR VETERINARY COLLEGE ROAD BIKANER 334001 RAJ | BIKANER | RAJASTHAN | 334001 | L1 | Accepted-AOC Lowest BIdder | |
| 2 | L2₹16.5 L+₹16,642.35 (1.02%)Rejected-Finance 2788 FOURTH FLOOR GALI RAJPUTANA ARYA PURA SABZI MANDI NEW DELHI KAMLA NAGAR NORTH DELHI DELHI 110007 UDYAM DL 01 0057966 | NORTH DELHI | DELHI | 110007 | L2 | Rejected-Finance Other than Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
22 Sept 2022, 6:00 pmClosed
GE NASIRABAD
GE NASIRABAD Pin 305601 (Raj)
ADDN/ALTN AND SPL REPAIR OF BLDG NO T-15 PROVN OF STORE ROOM FOR JCOS CLUB ADDN/ALTN TO FALSE CEILING OF BLDG NO TA05 AND TA06, PROVN OF MODULAR KITCHEN OF BLDG NO AFI1 OF 316 MED REGT AND ADDN/ALTN OF IRON GRILL DOOR AND WINDOWS IN BLDG NO T-02
2022_MES_547694_1
8259/E8
Open Tender
Civil Works
Item Rate
183 days
NASIRABAD
AS PER NIT
6 documents required · 6 mandatory
₹500
GE NASIRABAD
₹40,000
Yes
10 Nov 2022
25 Aug 2022
24 Sept 2022
25 Aug 2022
22 Sept 2022
10 Sept 2022
25 Aug 2022 - 31 Aug 2022
Amount
Excavation in trenched n exc 1.50 m in width and n exc 1.50m in depth for foundation , manholes , cesspits, etc n exc 10 sqm on plan and getting out in hard/dense soil complete all as specified and directed
M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in foundation filling and mass concrete complete all as specified and directed.
M&L for brick work with old size fly ash bricks bricks staright or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
All as per description of serial item no. 3.00 above but except brick.
M&L for brick work with old size fly ash bricks staright or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M&L for 40mm thick PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in damp proof course on horizontal surface using water proofing compound including necessary formwork complete all as specified and directed. Note : - Supply only water proofing compound shall be measured and paid for separately.
M&L for broken stone hard core of gauge n exc 63mm deposited spread and levelled in layers n exc 15 cm watered and rammed to a true surfaces complete all as specified and directed
M&L for 75 mm thick PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified & directed. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
Returning filling in including spreading levelling watering and well ramming in layers n exc 25 cm thick complete all as specified and directed.
Filling under floor including spreading levelling watering and well ramming in layers n exc 25 cm thick complete all as specified and directed
Removel of surplus soil to a distance n exc 50m and depositing where directed at a level n exc 1.5m above from the starting point complete all as specified and directed.
M & L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M & L for mild steel TMT bars 5mm dia and over upto including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M & L for RCC M-25 grade (design mix) using 20mm graded aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and beams, sides and soffits (if any) of foundation and plinth beams , and similar work, vertical or to batter, flat surfaces of concrete , surface is required to be fair finished complete all as specified and as directed by the Engineer-in-Charge
M & L for M-25 grade (design mix) using 20mm graded aggregates as in columns, pillars, piers, posts and struts complete all as specified and as directed by the Engineer-in-Charge.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions, rectangular or polygonal surfaces of concrete , surface is required to be fair finished. complete all as specified and as directed by the Engineer-in-Charge.
M & L for RCC M-25 (design mix) using 20mm graded aggregates as in roof beams, lintel beams/bands, cantilevers, bressummers, lintels over 1.5m span, chajjas etc complete all as specified and as directed by the Engineer-in-Charge.
M & L for formwork to sides and soffits of floor or roof beams, soffits of lintel beams/ bands, chajjas, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc, also splays between floors and beams, etc., flat surfaces of concrete , surface is required to be fair finished. complete all as specified and as directed by the Engineer-in-Charge.
M & L for RCC M-25 (design mix) using 20mm graded aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), flat surfaces of concrete , surface is required to be fair finished. complete all as specified and as directed by the Engineer-in-Charge
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, as roughed finished surface of concrete complete all as specified and as directed by the Engineer-in-Charge
M&L 15mm thick rendering on brick /concrete work surfaces in CM 1:4 finished fair and even without using extra cement using WPC as per manufactuere instructions (WPC is to be measured and paid separately)
M&L 10mm thick redering on brick work surfaces in CM 1:6 finished fair and even without using extra cement complete all as specified and directed
M&L for rendering on brick work or concrete surface in cement mortar (1:4) 10mm thick as in ceiling surfaces finished fair and even complete all as specified & directed.
M&L for preparation of new plaster surfaces and applying three coats of lime/ white wash on ceiling complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper of approved shade over a coat of primer over a finished coat of white putty complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer, complete, all as specified and directed.
M&L for machine cut Kota stone slab flooring of size not less than 550X550mmX20-25mm thick over and including 15mm thick screed bed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified & directed.
M&L for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over and including cement screed 10mm thick in CM (1:4) & jointed with grey cement slurry mixed with pigment to match the smooth of the slab incl rubbing & polishing complete all as specified & directed.
S & F second class HW 35mm thick, factory made, plain framed, paneled shutter (Two panels) with panels of 9mm thick BWP grade ply wood bonded with high quality liquid phenol formal dehyde synthetic resin adhesive conforming to IS-710. The size of rails & style shall be as per IS-1003 (part-I) kiln seasoned & chemically pressure treated complete all as specified and directed.
Supply and fixing for 2nd class HW 35 mm thick, gauged and skeleton shutters (Thwo Panels), factory made open rebated and prepare to receive glass, gauge etc (with sash bar), edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass etc. Size of members of shutter shall be as specified in SSR 2009 Part-I, section 8 clause Member shall be kiln seasoned & chemically pressure treated complete all as specified and directed.
M & L for rolled mild steel work angle iron as in door frame and other similar work confirming to Grade E-165 (Fe 290) including fixing lugs/MS bars, complete all as specified and directed.
S & F Steel ventilator factory made, out of MS hollow section 79mm x 39mmx1.6mm thick frame with double shutter (glazed & wiregauged shutters) made out of Z section using flush butt welding and tennon riveting all as per IS 1038/83, dobby hinges shall be provided to both shutters, Locking arrangements, 25mm aluminium knobs to shutter, aluminium hook & eye, 10mm MS square bars in grill, 04 Nos lugs welded to frame Z section handle 100mm inculding necessary flat iron beading for securing wire gauge etc including holes, cutting holes for hold fast and making good in PCC 1:2:4 type B-1 including synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and directed. Note :Wire mesh and sheet glass shall be measured & paid separately under respective items.
S&F sheet glass , ordinary quality 3mm thick fixed with oil putty size of glass n exc 0.50 Sqm in each pane complete all as specified and directed.
S&F for aluminium anodised barrel tower bolt 150mm long of extruded section complete all as specified and directed.
S&F for aluminium anodised handle 150mm long fabricated type complete all as specified and directed.
S&F MS butt hinges medium weight cold rolled ISI marked of size 100mm complete all as specified and directed.
M&L for preparation of steel surfaces over 10 cm width or girth & applying two coats of synthetic enamel paint of 1st quality over a coat of red oxide primer complete all as specified and directed.
Supply only integral water proofing compound, ISI marked.
M & L for 20 to 25 mm thick machine cut kota stone shelves including rubbing & polishing and set in CM (1:4) including cutting, inserting into wall not less than 50mm deep and making good to disturbed surfaces complete all as specified and directed.
M&L for factory made 60mm thick machine pressed precast cement concrete coloured interlocking paver blocks of Grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and pigment laid over & including 50mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified & directed.
M & L for 75 mm thick PCC 1:3:6 type C-2, using 40 mm graded stone aggregates as in sub base etc complete all as specified and directed.
M&L for screeding 10mm thick in CM 1:4 on fair faces of RCC /stone patti roof surface finished fair & even to receive roof treatment, complete all as spescified and directed.
M & L for five layered roof treatment with APP modified polymeric water proofing membrane, 2mm thick having centre core not less than 100 micron high molecular high density polythylene film (HMHDPE) protected on both sides with high polymeric asphaltic mix and 20 micron HMHDPE film weight not less than 3 Kg/ Sqm applied with bonding material using belown type bitumen conforming to IS-702 Grade 85/25 @ 1.20 Kg/ Sqm over bitumen primer conforming to IS- 3384 @ 0.40 Kg/ Sqm with final coat of bonding bitumen grade 85/25 @ 1.20 Kg/ Sqm over APP membrane with all overlaps complete all as specified and directed.
M&L for 40mm thick (average consolidated thickness) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate laid in slope as in padding, finished even and smooth on existing slope including provision of 'V' shaped groove 6mm wide and 10mm deep at 1.20 metre interval or parts thereof, both ways on top of PCC padding and filled with mastic bitumen of (1:1) proportion complete all as specified and directed.
M&L for coved fillet in PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate at junction of roof & parapet wall and other vertical surfaces and surface painted with a hot paving bitumen grade 30/40 conforming to IS-73 @0.70 Kg/Sqm over a coat of bituminous primer conforming to IS-3384 @ 0.30 Ltr Sqm complete all as specified and directed
Taking out of old grill & M & L for framed work such as grills, gratings, etc, with ends of bars shouledered and /or reiveted ,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of watertanks and similar work coforming to Fe 290m Gde E-165 complete all as spd and directed.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
M&L for rendering 15mm thick in cement mortar 1:6 on stone masonry surfaces or surfaces other than fair face of brick work of walls, finished even & smooth without using extra cement complete all as specified.
M&L for rendering 15mm thick in CM 1:4 on stone masonry, external surfaces, finished even & smooth without using extra cement complete all as specified.
M&L for preparation of old white washed surfaces of ceiling and applying two coats of white wash complete all as specified and directed
M&L for preparation of new plastered surfaces and applying three coats of white wash on wall complete all as specified and directed
M&L for preparation of old white washed surfaces and applying two coats of white wash on wall complete all as specified and directed
M&L for 50 mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
Taking down unserviceable chowkhats or frame with shutters (without taking off shuters from the frames) of any description exc 1.50 Sqm and removing from site and making good disturbed surfaces of wall in CM 1:3 complete all as specified & directed. (For windows and ventilators)
Demolition of stone/brick masonry built in cement or cement lime mortar all as specified and directed.
Supply and fixing of 30mm thick factory made solid panel PVC door shutter (style) consisting of frame made out of MS tubes for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded. sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement, complete all as specified and directed.
S&F in repairs vitreous china wash down water closet squatting pattern ( Urissa pattern) with trap including connection to existing out joint pipe, flushing pipe or Cistern, antisyphonage pipe, including making, etc complete including making goood to floor etc complete all as specified and as directed.
Taking out old unserviceable wash down water closet and S & F vitreous china wash down water closet pan (pedestal pattern), white, including plastic white cover closed pattern with flat bottom and mild steel chromium plated hinge device including connections to drain (or outgoing pipe ) and to flushing pipe anti syphonage pipe etc complete all as specified and directed
S&F in repairs PVC low level flushing cistern syphonic action type white with inlet ball valve, handle including brackets 10 ltrs capacity etc complete all as spcified and directed.
S & F in repairs PVC connections 15mm size with PTMT nuts and bolts of length 450mm etc complete all as specified and directed
S&F in repairs 15mm bore cast copper alloy chromium plated bib tap with crutch or butterfly handle, screwed down, screwed for iron pipe complete all as specified.
S&F in repairs 15 mm Stop valves, cast copper alloy, chromimum plated, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions.
Disconnecting & taking down the existing unserviceable water tank and S&F new 1000 Litre capacity Rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top), hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I. Note :- The unit rate quoted by tenderer shall be deemed to included water tank with GI pipe medium grade 10cm long projected inside and outside of tank with bore suitable for inlet and outlet, GI pipe 20mm bore medium grade projecting 10cm inside and outside of the tank for over flow, GI pipe 20mm bore medium grade projected 10cm inside and outside of tank for vent & mosquito cover for vent/overflow pipe.
Taking up or down steel tubing and connection 15 mm bore and removing the same from site/keeping aside for reuse complete all as specified and directed.
All as per srl item No. 66.00 above above but 20 mm bore pipe.
S & F water tubing 15 mm bore, medium weight, ISI marked galvanized with all fittings and fixed to walls, ceiling or laid in floors complete all as specified and directed.
All as per srl item No. 68 above but 20 mm bore pipe.
Fixing only 15mm bore old GI tubing to walls, ceiling or laid on floor including necessary cleanig, cutting, screwing and new fittings such as elbow, Tee, union, socket, reducer etc.
All as per srl item No. 70.00 above but 20 mm bore pipe.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks etc, including removal to store complete all as specified and directed.
S&F 110mm dia PVC pipe fixed on wall under walls as spout complete all as specified and directed.
Supply only stack clamp out of 50mm by 3mm flat iron and 16 mm dia round iron stays fixed to pipe of bore 110mm complete all as specified.
S&F PVC bend/ shoe of dia. 110mm complete all as specified including taking down old unserviceable complete all as specified.
S&F in repair Soap dish any type, fixed to plugs with chromium plated brass screws embedded in the wall complete all as sped & directed.
Taking out old un serviceable tubular towel rail & S&F tubular towel rail aluminium anodised 20mm dia 'D' type 60cm long between flanges complete all as specified & directed.
S&F Steel window/ ventilator glazed and gauged (combination) with side hung/ top hung shutters incl box type / projecting type hinges, and steel peg stay, handle & locking arrangement and frame made out of 1.25mm thick pressed steel frame complete incl necessary AC/Cooler arrangement in window & guard bars complete all as as specified and directed.
M & L for non-skid ceramic coloured tiles (joint free), 7 to 8 mm thick ( square/rectangular), area of each tile exc 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match the shade of tile laid over and including screed bed 15 mm thick in CM (1:6) laid over and including 25mm thick, PCC (1:2:4) type B-0 using 12.5 graded stone aggregate complete all as speciied and directed.
M & L for glazed ceramic coloured tiles, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, on vertical surfaces of wall such as dados, skirtings etc set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match with the shade of tile over and including 10mm thick screed plaster in CM (1:4) complete all as specified and directed.
S&F in repair brass chromium plated shower rose of 125mm size with swivel joints, including Fixing to steel pipe or union of 15mm bore complete all as specified and directed.
Demolition of cement concrete (unreinforeced) in floors and paving n.exc 15cm thickness (above or below ground level) complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregare for packing under & haunching against the sides of drain pipe after they are laid and tested for 150mm bore pipe complete all as specified and directed.
M&L for 150mm bore salt glazed stone ware drain pipe grade 'A' laid in trenches and jointed in CM(1:1) tested complete all as specified and directed.
M&L for 50 mm thick rough dressed sand stone slab for manhole covers jointed and pointed in CM(1:4) complete all as specified and directed.
Fabrication & fitting of modular kitchen with cabinet / shelves & wardrobe / cupboard made out nof 18mm thick (one side decorative lamination & other side balancing lamination ) PVC sheet with piano hinges including providing cabinet for keeping baskets / cutlery basket with handles door shutters all as specified and directed. Note : PVC sheet, fittings & fixture will be measured and paid separately.
Supply only 18mm thick (one side decorative lamination & other side balancing lamination sheet) solid PVC board of make : Rajshree or equivalent all as specified and approved by Accepting Officer with cement solvent adhesive for shutter / kitchen cabinet / cup boards / partition wall / wall cabinet and similar work complete all as specified and directed.
Supply only soft close clip on hinge bright finish complete all as specified and directed.
Supply only 125mm dia oval shape brass handle fancy type bright finish complete all as specified and directed.
S&F Stainless steel basket (plain) of approved quality of size 520 x485x 100mm complete all as specified and directed. Make: Godrej SS 304
S&F Stainless steel plate basket of approved quality of size 520 x 485 x 150 mm complete all as specified and directed. Make: Godrej SS 304
S&F Stainless steel cup & saucer basket of approved quality of size 520 x 485 x 100 mm complete all as specified and ditected. Make : Godrej SS 304
Supply & fix Stainless steel glass basket of approved quality of size 520 x 485 x100 mm complete all as specified and directed. Make : Godrej SS 304
Supply & fix Stainless steel two shelf pull out basket of approved quality of size 520 x 485 x 150mm complete all as spd and directed. Make :Godrej SS 304
Supply only basket / trolly channel 50cm long extruded MS galvanised over roller complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation old treated concrete surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Dismantling of ceiling board/lathing any thickness including frame work complete all as specified and directed.
Providing & Fixing false ceiling with Fibre Cement Designer tile Ivory painted (High Pressure Steam Cured) of 4mm thickness (as per IS:14862) of size 595x595 mm and any one of the design (oceanic, lake & hill, cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and 15x32 mm made from 0.30 mm thick sheet, spaced at 1200 mm c/c and cross "T" of size 15x32 mm made of 0.30 mm sheet, 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size15x32 mm made of 0.30 mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 15x20 mm made of 0.30 mm thick sheet and laying false ceiling tiles in the grid including , required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15mm of all T -sections shall be centra black pre-painted with polyester paint, and having a load bearing capacity of 12 kg/sqm, all complete at all heights as per direction of Engineer-in-charge.
Dismantling asbestos Cement (corrugated, semi corrugated, etc) sheets in roof covering complete all as specified & directed.
S&F 6mm thick asbestos cement corrugated or semi corrugated sheets in roof fixed with L-type or J-type or cranked hook bolts complete all as specified & directed.
All as per srl item No. 101.00 above but except sheets.
M&L for asbestos cement two piece adjustable plain wing ridge 6 mm thick complete all as specified & directed.
Taking down shutters of any description exc 1.00 Sqm but n. exc 2.00 sqm each leaf and refixing in same opening complete all as specified and directed
M&L for PCC 1:2:4 Type B-1 (using 20mm stone crushed agg.) as in fixing of hold fast and other similar work complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, holders, regulators, sockets etc., removing materials from site and making good disturbed surface of walls, floors etc.
Taking down MCB DB's complete with MCB's/Isolator etc removing materials from site and making good disturbed surface of walls, floors etc complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm, PVC insulated, unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit 20mm dia or higher complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and sunk type pressed steel anodised terminal box 1.2 mm thick with bakelite laminated sheet top cover 3 mm thick, brass screws and cup washers including 1.5 Sqmm stranded copper conductor PVC insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories for:-
One light point controlled by one, one way switch.
One ceiling fan/exhaust fan point controlled by one, one way switch.
One three pin 5 Amp socket on same board with other switches.
One 3 pin 5 Amp socket on independent board.
All as per item No. 108.00 here-in-before but with 2.5 Sqmm, for one 5 pin 5/15 Amp socket on independent board including 2.5 Sqmm stranded copper conductor (FRLS) PVC insulated green in colour as continous earth conductor connected to common earth.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed multistranded (FRLS) copper conductor cable of size 4.00 Sqmm LT, 1100 volts grade, drawn through and including 25 mm dia or higher PVC non metallic concealed conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 4 sqmm single core multistranded copper conductor cable green colour as earth continuity conductor.
S&F switch piano flush type 5 amps, single pole one way 240 volts.
S&F switch piano flush type 15 amps, single pole one way 240 volts.
S&F Socket outlet 3 Pin 5/6 Amp flush type.
S&F socket out let 2 in 1,multipurpose 3 pin 15/16 Amp flush type ISI marked complete.
S&F ceiling fan regulator electronic flush , steped (four step) 230 Volts AC
S&F ceiling rose surface bakelite 3 terminals 63.5 x 17 mm.
S&F of lamp holder PVC/polycarbonate type with back plate complete all as specified and directed.
S&F LED tube light fitting in acrylic linear tube (1x 18 watt),230V for single LED tube light including 1 x 18 W LED retrofit bar professional CW 6500 K cover channel, bipin holders,LED power driver, connector block, etc complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable with suitable size for connection of fitting from ceiling rose complete all as specified and directed. Make :- Havells Cat part No PHOTONULTRA2.01212T8SSTL20WLED 865SPC (for tube) REGALBATTENT8UPTO1X22WDSBSWH (for batten)/ Bajaj Cat Part No BLRB 18W CWc for tube & BLRB - DB 118 for batten or equivalent model from Philips/Crompton
S & F LED light fitting 1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Bajaj/Havells/CG
Supply and fixing testing and commissioning energy saving street light luminaire 35 watt LED , pressure die cast housing with epoxy powder coated with colour finish and prismatic poly carbonate coverlic cover complete, IP 66 protection incl connecting with three core copper flexible wire from ceiling rose to connector of light fitting complete all as specified and directed by Engr-in-Charge. Make- Havells Cat Part No ENDURACITYLITEPLAT PLUSSL35WLED757SASYBOPC or equivalent model from Surya/Control& Switchgear/Bajaj
Supply and fixing street light bracket made of 32 mm GI pipe , 1.2 mtr lenght fixed with two nos of clamp , nut and bolts for fixing of street light complete all as specified and directed by Engr-in-Charge.
S & F MCB SP, 240 volt, 6 Amp to 40 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
S&F MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door IP-43 DB's , made out of sheet steel enclosure, recessed type, factory made powder coated 4 way, 240 volts suitable for housing MCB's including blanking plate complete all as specified and directed.
S & F MCB SPN, 240 volt, 32 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
S&F exhaust fans AC single phase 230V of size 300mm sweep with louver including connecting with three core flexible copper wire from ceiling rose to connector of fan complete all as specified and directed. Make: Havells/Bajaj/Crompton
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end of earth wire connected to main switch board and protected by galvanised iron pipe light grade 15mm bore and water pipe 20 mm bore GI med grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover with handle all as specified and shown in elect plate No 3 of SSR Part-I of 2009 incl dismantling of old unsv existing earthing complete all as specified and directed.
S&F LED lamp 9/10 watt., B-22 base for fixing in lamp holder complete all as specified and directed. Make: Havells/Bajaj/Crompton
Supply & fixing ceiling fan 1200 mm sweep , 230 Volts, AC , 50 Hz, copper winded motor, BEE 5 star rated white colour complete with motor, blade set of three nos , down rod, canopy, shackle assy, complete, all as directed by Engr-In-Charge. Make: crompton/Havells/Usha.
Taking down existing ceiling fan, dismantling blades and refixing after cleaning including connecting up with three core flexible cable from ceiling rose to fan, complete, all as directed.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than one metre apart including 4 mm dia suspension wire one twin core cable 2 core flat of 10 Sqmm size, all as directed.
M/s AKASH CONSTRUCTION CO.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .