Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC 1ST FLOOR GURJEET MARKET DHANGU ROAD | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39.6 L+₹2.4 L (6.33%)Rejected-Finance FRIENDS COLONY STREET A DHANGU ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹41.2 L+₹4.0 L (10.6%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹42.8 L+₹5.5 L (14.8%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | dadwal engineers L4 | Vijay Kumar Contractor and Engineers L1 | M/S SINGH AND ASSOCIATES L2 | JAGDISH SINGH ASSOCIATES L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out of any type of soil complete all as specified and directed by Engineer-in-Charge. | 177.25 | Cum | 150 ₹26,587.5 | 150 ₹26,587.5 | 100 ₹17,725 Lowest | 130 ₹23,042.5 |
| 2.00 | Excavating in trenches, n exc 1.5m wide and exc 1.5m and n exc 3.0m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out of any type of soil complete all as specified and directed by Engineer-in-Charge. | 81 | Cum | 120 ₹9,720 Lowest | 200 ₹16,200 | 150 ₹12,150 | 150 ₹12,150 |
| 3.00 | Excavating in trenches, n exc 1.5m wide and exc 3.0m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out of any type of soil complete all as specified and directed by Engineer-in-Charge. | 72 | Cum | 120 ₹8,640 Lowest | 300 ₹21,600 | 200 ₹14,400 | 130 ₹9,360 |
| 4.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in any type of soil complete all as specified and directed by Engineer-in-Charge. | 265.25 | Cum | 100 ₹26,525 | 30 ₹7,957.5 Lowest | 50 ₹13,262.5 | 55 ₹14,588.75 |
| 5.00 | Removing excavated material and depositing where as directed and spreading and levelling in layers n exc 25 cm thick complete all as specified and directed by Engineer-in-charge. | 65 | Cum | 100 ₹6,500 | 60 ₹3,900 | 50 ₹3,250 Lowest | 60 ₹3,900 |
| 6.00 | Material and labour for bringing extra earth if required from outside ministry of defence (MOD) land for filling and raising (or lowering) earth, spreading in layer not exc 25 cm thick, watering, compacting and finishing to required gradient/ shape and deposited where complete all as specified and directed by Engineer-in-Charge. | 55 | Cum | 320 ₹17,600 | 500 ₹27,500 | 100 ₹5,500 Lowest | 500 ₹27,500 |
| 7.00 | Plain Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundations,filling and mass concrete, complete all as specified and directed by Engineer-in-Charge. | 16 | Cum | 3,200 ₹51,200 | 3,000 ₹48,000 Lowest | 3,500 ₹56,000 | 3,200 ₹51,200 |
| 8.00 | Material and labour Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in Cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. | 140 | Cum | 5,400 ₹7,56,000 | 3,500 ₹4,90,000 Lowest | 5,500 ₹7,70,000 | 6,000 ₹8,40,000 |
| 9.00 | Reinforced cement concrete (Type B1 1:2:4, 20mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles complete all as specified and directed by Engineer-in-Charge. | 17 | Cum | 4,100 ₹69,700 Lowest | 6,000 ₹1,02,000 | 5,500 ₹93,500 | 6,200 ₹1,05,400 |
| 10.00 | Supply and fixing Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-W (Gde E 250) Quality A or Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-Charge. | 2,000 | Kg | 105 ₹2,10,000 | 90 ₹1,80,000 | 100 ₹2,00,000 | 85 ₹1,70,000 Lowest |
Tender Value
₹43.6 L
EMD Value
₹87,300
Closing Date
1 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Mahajan Singh
GE (AF) Pathankot
ADDITION ALTERATION TO SINGLE LIVING ACCN P 372 FOR AGNIVEER WOMEN AT AIR FORCE STATION PATHANKOT
2025_MES_712075_1
GE/PAF-19/2025-26
Open Tender
Civil Works
Item Rate
120 days
GE (AF) Pathankot
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Pathankot
₹87,300
Yes
22 Aug 2025
3 Jun 2025
3 Jul 2025
3 Jun 2025
1 Jul 2025
17 Jun 2025
Amount
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out of any type of soil complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5m wide and exc 1.5m and n exc 3.0m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out of any type of soil complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5m wide and exc 3.0m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out of any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in any type of soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material and depositing where as directed and spreading and levelling in layers n exc 25 cm thick complete all as specified and directed by Engineer-in-charge.
Material and labour for bringing extra earth if required from outside ministry of defence (MOD) land for filling and raising (or lowering) earth, spreading in layer not exc 25 cm thick, watering, compacting and finishing to required gradient/ shape and deposited where complete all as specified and directed by Engineer-in-Charge.
Plain Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundations,filling and mass concrete, complete all as specified and directed by Engineer-in-Charge.
Material and labour Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in Cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete (Type B1 1:2:4, 20mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-W (Gde E 250) Quality A or Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required etc., quality conforming to Fe-410-W (Gde E 250) Quality A or Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-Charge.
Precast cement concrete louvres and jallies 35mm thick(measured solid ) (1:2:4) type B0(12.5mm graded crushed stone aggregate) set in cement mortar 1:4, including all moulding complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick work or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer-in-Charge.
Material and labour 15 mm thick plastering in cement mortar 1:4 on brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Supply only Liquid Water proofing compound complete all as specified and directed by Engineer-in-Charge.
GI wire netting 0.90mm dia and 12mm mesh lathing( in repair in patches n exc 5 sqm each) to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste including taking down old and jointing new to old as required complete all as specified and directed by Engineer-in-Charge.
Applying 3mm thick white putty on wall surfaces and rubbing the surface even and smooth complete all as specified and directed by Engineer-in-Charge.
Material and labour Preparation of old surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot , moulds moss and efflorosent salts , trading oil and greasy spots and applying two coats of weather proof acrylic exterior emulsion paint as approved of any shade/colour complete all as specified and directed by Engineer-in-Charge.
Material and labour applying two coats of weather proof acrylic exterior emulsion paint as approved of any shade/colour over a coat of primer including preparation of newly plastered surfaces as per manufacture instructions complete all as specified and directed by Engineer-in-Charge.
Material and labour Complete removal of existing treatment on surfaces of wall/ceiling by brooming down or steel wire brushing, scrapping down smoke soot , moulds moss and efflorosent salts , trading oil and greasy spots and applying Two coats of oil bound distemper complete all as specified and directed by Engineer-in-Charge.
Preparaption of old wooden surfaces of any description not otherwise described, over 10 cm width or girth and providing One coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Preparaption of old painted surfaces of any description not otherwise described, over 10 cm width or girth and providing one coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Taking out old serviceable glass of any description, from old wooden or metal frames, or stone, concrete or brick sur- rounds, any thickness or size; hacking out old putty or removing beads etc, including making good breakages in taking out and handling removing to store or stacking for reuse complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 3mm frosted glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed by engineer-in-charge.
Powder coating aluminium frame(minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer-in-Charge.
Powder coating aluminium door shutters of any colour (Thickness or powder coating not less than 50 micron), aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, aluminum snap beading screws etc. complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 10mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and directed by Engineer-in-Charge.
Double action floor spring hydraulically regulated madeup of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for heavy duty angle door locks with set of three keys of premium quality of design and color as approved to be fixed in doors and locking assembly in chowkhat complete all as specified and directed by Engineer-in-Charge.
Material and labour pressed steel frame made out of MS sheet 1.25mm thick of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including filling of concrete 1:3:6 type C-1 back of chowkats,with two coats of synthetic enamel paint over one coat of red oxide primer including taking down with existing one complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 35mm thick plain framed panelled door shutters of 2nd class hard wood two panel with lock rail and panel of 9mm thick BWP commercial ply ,the size of rail and style as per IS : 1003 Part-I, Kiln seasoned and chemically pressure treatedfactory made shutters wood is to be incorporated complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 2nd class hard wood 35 mm thick made glazed and skeleton shutters open rebated and prepared to rceieve glass, gauze,etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, size of members of shutters as specified in SSR Part-1, Section 8, clause 8.24 (a) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stailess steel wire staples complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 100mm long (12Gauge) butt hinges stainless steel anodised and fixed complete all as specified and directed by Engineer-in-Charge. NOTE :- All screws shall be self tapping chrome plated and length of screw not less 38 mm
Supply and fixing Stainless steel sliding door bolts, plate type, , with bright bolt not lesss than 10mm dia with and incl a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate 300mm long complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Stainless steel Tower Bolt of 200 mm long fixed with Self Tapping screws complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Stainless steel Tower Bolt of 150 mm long fixed with Self Tapping screws complete all as specified and directed by Engineer-in-Charge.
Preparaption of new wooden surfaces of any description not otherwise described, over 10 cm width or girth and providing two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Providing solid PVC SHEET WALL PANELLING of thickness 5mm ( ±0.25 ) consisting of panels of desired size stuck on inner frame work of 50mm wide strips of 5mm (±0.25 ) thick Prelam PVC sheet. The panel & strips shall be Density of 600 Kg /Cbm Manufactured by an ISO-9001-2015 certified Company. The strips should have in their center a grove of 6mm width and 1mm depth for sinking the head of the screw used to fix the strips to the wall vertically at an equal interval of 10” between two PVC strips. The PVC strips shall be fixed to the wall using 65mm long M.S. screws through the groove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200mm. A groove of 2mm may be left at the joint of two panels for aesthetic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. Optionally a strips of 5mm (±0.25) thick PVC sheet of width 75mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cement complete all as specified and directed by Engineer-in-Charge.
Surface dressing n exc15 cm deep in any type of soil complete all as specified and directed by Engineer-in-Charge.
Material and labour Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
Material and labour for Cement concrete type C-2, 1:3:6 (40mm graded crushed stone aggregate) as in sub base of flooring, plinth protection etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
Machine pressed precast concrete rubber moulded glossy interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and directed by Engineer-in-Charge.
Filleting in any position and to any shape in cement mortar 1:4 including all mitres, stops, etc n exc. 25 sq cm complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel works of any description not otherwise provided complete all as specified and directed by Engineer-in-Charge
Dismantling plain or corrugatd steel sheeting any gauge, thickness any type including Nanital or similar pattern roof covering complete all as specified and directed by Engineer-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu.m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in any type of soil complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Fe410-W(GdeE-250) quality A Rolled steel in Joist, channel, angle, or tee sections, GI pipes as in post, rafter, purlin gate etc., fixed independently, without connecting plates, etc. complete all as specified and directed by engineer in charge.
Plates (plain or chequered) channels, square cut or notched of Fe410-W(GdeE-250) quality B (ordinary and counter sunk)forming holes, without any attachment complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed by Engineer-in-Charge.
Painting two coats with synthetic enamel paint on new steel or iron surfaces of any description exceeding 10 cm width/girth including preparation of surfaces and over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.
Material and labour for grinding and polishing of existing kota stone floor (grinding to be done at least twice) to achieve desired finish including fixing of kota stone in pieces if any piece or pieces are to be replaced to match the existing shade complete all as specified and directed by Engineer-in-Charge.
Material and labour Position suspended false ceiling system using T-grid suspended ceiling grid system. The size of grid shall be 600 x 600mm with GI frame work main runner 38 x 24mm x 3600 mm, cross tee 25 x 24 x 600mm / 25 x 24 x 1200mm and wall angle 24 x 24 x 2540mm ( thickness of the material of 0.30 mm), using 9mm thick ceiling panel laminated with PVC film on front face and foil back available in due drop texture as per IS-2095, part-I-1996, fixed in the grid of T-grid suspended ceiling grid system duly suspended by 4mm dig GI bar hanger from the purlins of the roof with butter fly clips complete all as specified and directed by Engineer-in-Charge.
Material and labour for 75 mm thick Cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection, floor,etc, finished even and smooth without using extra cement, including demolition of existing cement concret complete all as specified and directed by Engineer-in-Charge.
Cutting in to existing manholes 150mm dia for connecting new drains,making good to pipe and rendering,cutting out existing benching for and forming branch channel(1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished,and reforming benching as required complete all as specified and directed by Engineer-in-Charge.
Taking down old damaged SGSW/UPVC/RCC pipes from existing line Supply and fixing HDPE DWC (Double wall corrugated) pipes confirming to IS-16098 of 152mm & 180mm internal & external dia respectively, pressure rating SN-8 fixed with rubber seal and copler required with and including suitable bends 90/60/45 degree etc, single Y junction, complete as required fixed as per manufacturer instruction laid in trenches for sewage lines complete all as specified and directed by Engineer-in-Charge. Note:- Rated included for pipes, bends any size and any types, Y junction copler/adaptor etc required and net total length of pipe with fitting shall be measured for payment purpose. Rate quoted by the contractor shall also include (a) Removal of broken pipes, concrete bed and any other material upto 50m (b) Making surface under sewage pipe to required gradient for smooth flow of sewage (c) Filling and proper ramming of earth under, around and above the pipe after pipe is laid and tested and providing smooth/ levelled finish as already existing.
Supply and fixing HDPE DWC (Double wall corrugated) pipes confirming to IS-16098 of 260mm & 300mm internal & external dia respectively, pressure rating SN-8 fixed with rubber seal and copler required with and including suitable bends 90/60/45 degree etc, single Y junction, complete as required fixed as per manufacturer instruction laid in trenches for sewage lines complete all as specified and directed by Engineer-in-Charge. Note:- Rated included for pipes, bends any size and any types, Y junction copler/adaptor etc required and net total length of pipe with fitting shall be measured for payment purpose. Rate quoted by the contractor shall also include (a) Removal of broken pipes, concrete bed and any other material upto 50m (b) Making surface under sewage pipe to required gradient for smooth flow of sewage (c) Filling and proper ramming of earth under, around and above the pipe after pipe is laid and tested and providing smooth/ levelled finish as already existing.
Supply and fixing 70mm thick factory made precast RCC manhole covers including precast frame of any size & shape(Squre/rectangular/circuler), light duty,conforming to IS - 12592, fixed at site etc complete all as specified and directed by Engineer-in charge. Note:- Contractor to deposit the full quantity to the MES store yard within 1 month of issuing of work order. The same will be placed at designated site by contractor labour. Rates for shifting of manhole covers from MES store yard to site deems to be included in the quoted rates and no separate payment will be considered on this account.
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator light fittings etc and removing from site and making good disturbed surfaces of walls floors etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for point wiring with two single core 1.5 sqmm cable (nominal area) stranded copper conductor, PVC insulated unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia with sunken type pressed steel terninal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes including all accessories and using single core 1.5 Sqmm (nominal area) stranded copper conductor, PVC insulated unsheathed cable as in earth wire (green colour) connected to common earth dolly complete all as specified and directed by Engineer-in-Charge for following :- (a) One light point controlled by one switch.
(b) One 3 pin switch socket outlet point 5 Amps on independent board.
(c) One 3 pin switch socket outlet point 5 Amps on same board.
All as per item srl No 63 above here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size complete all as specified and directed by Engineer-in-Charge.
Material and labour Switch piano flush type single pole, one way 5 Amps 230 Volts AC circuit complete all as specified and directed by Engineer-in-Charge.
Supply and fixing switch piano flush type,15 Amps, Single pole, two way complete all as specified and directed by Engineer-in-Charge.
Material and labour for socket outlet 5 Amps, 5 Pin flush type multipurpose, 230 Volts AC circuit complete all as specified and directed by Engineer-in-Charge.
Material and labour for socket outlet 2 in 1, 3 Pin 5 & 15 Amps, 230 Volts AC circuit complete all as specified and directed by Engr-in-Charge.
Supply and fixingix ceiling rose surface backlite 65x50mm 3 terminals complete all as specified and directed by Engineer-in-Charge.
Supply only Bell electric AC 230 Volts single pole complete all as specified and directed by Engineer-in-Charge.
Supply only Bell push, flush type, 5 amp complete all as specified and directed by Engineer-in-Charge.
Taking down old and unserviceable sub main wiring of 2/3 runs of any sizes from any position including, making good disturbed surface of wall ceiling etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed sub main wiring using single core four run PVC insulated, unseathed stranded copper conductor cable of size 10.0 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 10.00 Sqmm (green colour) as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. Note : Three runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Material and labour for concealed sub main wiring using single core four run PVC insulated, unseathed stranded copper conductor cable of size 6.0 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm (green colour) as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. Note : Three runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Material and labour for concealed sub main wiring using single core four run PVC insulated, unseathed stranded copper conductor cable of size 2.5 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 2.5 Sqmm (green colour) as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. Note : Three runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with hree core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED street light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing study table LED lamp 9 watt of body material plastic complete all as specified and directed by Engineer-in-Charge.
Supply and fixing cone round milky post top lantern 9 watt complete all as specified and directed by Engineer-in-Charge.
Servicing/overhauling the ceiling fan/exhaust fan of any sweep and make by throughly cleaning the bearing, shaft stator, rotor and applying the lubricant/ grease to the bearing including applying one coat of super enamelled varnish over the winding to improve the insulation value complete all as specified and directed by Engineer-in-Charge.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed by Engineer-in-Charge.
Taking down carefully unserviceable DB any type/size disconnecting and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
Sheet metal enclosure VTPN MCCB DB 4 Way, 415 V (vertical type) with bus bar double door type IP 43 - IK 09 as per IEC 61439-3 suitable for flush mounting complete with 250 A copper bus bar for each phase with 2 neutral and 2 earth bus bars with cable ties for cable management for DB's when MCBs & MCCB 100 Amps (as incomer) to be used, fixed properly in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and directed by Engineer-in-Charge.
Sheet metal enclosure Double door metallic for DB when MCBs to be used SPN 8 ways, 240 V with 200 Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed by Engr-In-Charge.
Taking down carefully unserviceable MCB SP/SPN/Isolator of any rating/size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement MCB SP 240 volt 6 Amp to 32 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed by Engineer-in-Charge.
All as per item srl No 89 above but SPN 40-63 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCCB 100 Amps, 3 Pole, 415 V, 16 KA thermal magnetic adjustable type with short circuit and overload protection complete all as specified and directed by Engineer-in-Charge.
Material and labour for earthing complete with galvanised steel plate electrode 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel earth wire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with 6mm dia M.S. round bar placed 75mm c/c and handle of 10mm dia, MS bar made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom, 1.75 meter long placed on top edge of earth plate, common salt & charcoal filling, funnel, wire mesh and earth work not exceeding 50 meters all as per electrical plate No 3 of SSR Part I (2009) and connected to earth test points all as specified and directed including testing on completion complete all as specified and directed by Engineer-in-Charge.
M/S SINGH AND ASSOCIATES (BID ID -3339058)
JAGDISH SINGH ASSOCIATES (BID ID -3335019)
dadwal engineers (BID ID -3332618)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .