| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹23.3 L+₹4.3 L (22.4%)Rejected-AOC LEKSHMI NIVAS TELANG ROAD NANDANGADDA KARWAR 581 304 | KARWAR | UTTARA KANNADA | KARNATAKA | 581304 | L2 | Rejected-AOC not L1 | |
| 3 | L3₹23.5 L+₹4.4 L (23.3%)Rejected-AOC 201 CHAURANG HEIGHTS CHS PLOT NO 117 SECTOR 13 KHARGHAR NAVI MUMBAI 410210 | NAVI MUMBAI | RAIGAD | MAHARASHTRA | 410210 | L3 | Rejected-AOC not L1 | |
| 4 | L4₹25.3 L+₹6.2 L (32.7%)Rejected-AOC 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L4 | Rejected-AOC not L1 |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
27 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sr DDG and CE
Sr DDG and CE , DGNP BUILDING, NAVAL DOCKYARD,SBS MARG, MUMBAI 400005
AUGMENTATION OF HULL STRUCTURAL FACILITIES FOR REPAIRS AT NSRY KARWAR
2020_MES_382220_1
8502
Open Tender
Civil Works
Item Rate
180 days
NSRY KARWAR
MES OR DGNP ENLISTED CONTRACTORS OF E CLASS CATEGORIES a i OR OTHER CONTRACTORS MEETING ENLISTMENT CRITERIA OF E CLASS
8 documents required · 8 mandatory
₹500
DGNP Mumbai
₹47,000
Yes
22 Jan 2021
13 Oct 2020
4 Dec 2020
13 Oct 2020
27 Nov 2020
13 Nov 2020
14 Oct 2020 - 29 Oct 2020
90 days
Amount
SCHEDULE 'A' PART-I (Building WORKS) Demolition of cement Concrete (Unreinforced) in ground floors and pavings n exc 15 cm thickness(below or above ground level)all as specified and directed..
M&L for cement concrete type C2(1:3:6) (using 40mm graded stone aggregate) as in foundations, filling and mass concreteall as specified and directed..
M&L RCC (1:2:4) type B-1 nominal Mix concrete, using 20 mm graded aggregate as in beams, cantilevers, lintels, over 1.5 m span all as specified and directed.
M & L formwork to sides and soffits of lintels,lintel band, beams etc finished rough surfaces of concrete complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F TMT bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F HIT-V anchor bolt of Hilti make of size M24x750mm long, including drilling or boring and grouting with cementious grout for 250mm length in soil and with anchor grout RE 500SD of Hilti make for 500mm in concrete and hardcore with necessary grouting tools etc complete all as specified and as directed.
S&F mild steel plate girder or single stanchions confirming to Fe 410-W(Gde-E- 250) quality-A, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections and including cutting to required length, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts etc. and fixing/erecting in true position and painted with one shop coat of zinc chromate primer paint (incl preparation of surface) at contractors workshop before fabrication complete all as specified and directed.
S&F of Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe 410-W (Gde-E- 250)quality-A and including cutting to required length, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts etc. and fixing/erecting in true position etc complete all as specified and as directed.
S&F mild steel rolled section confirming to Fe-410-W (Gde-E-250) quality-A in Roof trusses (framed), trussed,purlins, crane grantries, rails and fastenings and heavy bracket framing (Beam,tee, angle, channel or flat sections) and including distance pieces, cleats etc and cutting to required length, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts etc. and fixing/erecting in true position and painted with one shop coat of zinc chromate primer paint (including preparation of surface) at contractor's workshop before fabrication complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.
M&L for 40mm thick PCC 1:2:4 type B1(using 20mm graded stone aggregate) as flooring finished even and smooth without using extra cement etc complete all as specified and directed..
M&L for providing glass dividing strip (38mm in width and 3mm thick) as in flooring complete all as specified and directed..
M&L precast cement concrete block masonry with solid blocks type C 1 1:3:6 ( 20mm graded agg ), exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed.
S&F 1.6mm thick GI sheet as in roofing/ceiling fixed to angle iron frame by self drilling screws and 50mm anchored in existing wall at existing wall side etc complete all as specified and as directed.
M & L for rendering 15mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparing newly plastered wall surfaces, preparing surface even and smooth with a thin layer of putty (avg 3mm thick) to obtain desired finish and applying two coats of oil emulsion distemper over one coat of primer as per manufacturers instruction all as specified and as directed..
M & L applying two coats of Anti Corrosive Paint over a coat of Red oxide zinc chromate primer including preparation on Steel Surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and as directed.
M&L powder coated aluminium snap grid frame work for false ceiling all as specified and as directed (grid of size 605x605mm) (thickness of powder coating not less than 50 micron).
M&L for 16mm thick Perforated particle board/tiles for insulation and accoustic purposes,60x60 cm in size, fixed laid/inserted into aluminium powder coated snap grid as in ceiling flat or sloping etc all as specified and as directed.
Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and as directed
M&L for Screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in cement mortar 1:6 etc complete all as specified and as directed.
S&F for powder coated (min thickness of powder coating 50 micron) aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed.
S&F powder coated Anodised aluminium three track sliding windows with standard sections as directed by Engr-in-charge including powder coated aluminium shutters with 5.5mm thick sheet glass ordinary quality and glazing with oil putty, window frames, handle, cleat rubber packing, aluminium beading, screws, locking, fixing arrangement etc complete as per drawing and manufacturers instructions etc. complete all as specified and as directed.
S&F for aluminium grill of ALDG 02 of make Deco grill or equivalent to aluminium windows including necessary arrangement etc. complete as per drawing etc. pattern/drawing all as specified and directed.
S&F Aluminium mortice lock vertical type 75mm 4 levers all as specified and as directed.
S&F Aluminium (extruded section) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg all as specified and as directed.
SCHEDULE 'A' PART-II (Internal Elecrification) Material and labour for point wiring for one light point controlled by one switch with 1100 Volt grade single core ISI marked confirming to IS 694 (1990) PVC insulated unsheathed 1.5 Sq mm multi stranded copper conductor cable (FRLSH) with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) ISI marked PVC insulated-unsheathed, drawn in and including rigid, non metallic, PVC heavy duty concealed conduit (ISI marked ) not less than 20 mm dia { color coding of wires shall be for Phase , neutral and earth wire all as specified } sunken MS/ pressed steel boxes thickness not less than 1.6mm painted with black bituminous paint outside and two coat of aluminum paint inside for housing switches, socket, fan regulator etc covered with 2.8 mm thick hylem laminated sheet ( ISI Marked ) with screws, including making good disturbed surfaces of wall/ ceiling/floor complete all as specified and as directed by Engineer-in-charge. Note:Cost of cutting /leaving forming chases for conduits,sinking for boxes and making good shall deemed to be included in quoted rate.
All as mentioned in item No 30.00 above but for one socket outlet 6 amps on same switch board..
All as mentioned in item No 30.00 above but for one switch socket outlet 6 amps on independent.
. Material and labour for point wiring for one 16 Amps socket outlet point on independent board , controlled by one switch with 1100 Volt grade single core confirming to IS 694 (1990) PVC insulated unsheathed 2.5 Sq mm multi stranded copper conductor cable (FRLSH) for phase and neutral, ISI marked with continuous earth wire of 2.5 Sqmm stranded copper conductor cable (FRLSH) ISI marked PVC insulated-unsheathed with proper colour coding of Phase, Neutral & Earth, drawn in and including rigid, non metallic, PVC heavy duty concealed conduit (ISI) marked not less than 20 mm dia with concealed sunken MS/ pressed steel boxes thickness not less than 1.6 mm painted with black bituminous paint from outside and two coat of aluminum paint inside for housing socket covered with 2.8 mm thick hylam laminated sheet ( ISI Marked ) complete all as specified and as directed by Engineer-in-charge.
S&F switch socket combination 2 in 1, 3 pin 6 Amp and 3 pin 16 Amp, single pole ,one way 230V, 50Hz, ISI marked complete all as specified and directed by Engineer in charge.
S&F switch socket combination 2 in 1, 2 & 3 pin 6 amp Flush type complete all as specified and directed by Engineer in charge.
S&F socket outlet 2 in 1, 2 & 3 pin 6 amp Flush type complete all as specified and directed by Engineer in charge.
S&F piano switch 6A, SP, flush type, ISI marked complete all as specified and directed by Engineer in charge.
Supply & fix LED 24 watt down light square recess mounted light fitting with opaque diffused acrylic cover with all accessories having High lumen output, driver PF >0.98, having over voltage protection upto 400volts, surge protection level 7-10kv, thermal short circuit protection THD <10%, made up of long life LED chips(SMD) in modular with Ra >70 and LED lumen efficiency >120 lumen per watt, and connected with surface mounted square Back lit panel LED luminaire with diffuser 3 core flexible copper cable PVC insulated of size 1.5 Sqmm, with connector complete all as specified and directed by Engineer in charge. Make:- Shakti, Model No. SZRDSMX024 or equivalent model in Havells/ CG/ Wipro Note: The firm has to give warranty for light fitting including driver minimum for 3 years for any defects developed during the period.
S&F air circulator wall mounted fan, 450 mm sweep ,single phase, 230 volts AC,50 Hz,oscillating type including PVC insulated three core flexible copper conductor 1.5 sq mm drawn through flexible pipe connecting with ceiling rose complete all as specified and as directed by Engineer-in-charge.Model :Havells (Turbo force SP) or equivallent model in USHA/Crompton Greaves.
S&F sheet metal enclosure for 8 way VTPN DB doubel door 415/230V with 100 amps rated bus bar suitable for MCB TPN as incomer and TPN, TP, DP, SP MCB's as outgoing complete all as specified and directed by Engr-In-Charge. Note : (i) Incomer, outgoing TPN, TP, DP, SP MCB's shall be measured & paid seperately under respective item. (ii) MCBs shall be of same make.
S&F MCB SP 6-32A, 10KA, 230V, "C" curve, ISI marked complete all as specified and directed by Engineer in charge.
Supply and fix MCB TPN, 415 volts AC, 32 Amps ,"C" curve, 10 KA, 50 Hz, ISI marked all as specified and as directed by Engineer in charge.( Incomer)
Supply and fix MCB TPN, 415 volts AC, 16 Amps ,"C" curve, 10 KA, 50 Hz, ISI marked all as specified and as directed by Engineer in charge. .
Supply and Fix sheet metal enclosure for provision & including of 16 Amps 05 pin Plug & socket, MCB TPN 16 Amps, 415 volts, "C" curve, ISI Marked including all accessories complete all as specified and as directed by Engineer in charge.
M&L for ceiling rose, 3 terminal polycarbonate complete all as specified and directed by Engineer-in-charge.
Material and labour for sub main wiring with 4 single core 2.5 Sq mm nominal area with 1100 Volt grade confirming to IS 694 (1990) PVC insulated unsheathed with 2 runs of 2.5 Sq mm multi stranded copper conductor cable (FRLSH) ISI Marked for continuous earth wire drawn in and including rigid, non metallic, PVC heavy duty concealed conduit (ISI marked) not less than 20 mm dia with fittings including cutting, chasing, for conduit and making good of walls etc complete all as specified and as directed by Engineer-in-charge. (for 03 plugs & sockets) Note : Four runs of cable and two runs of earth cable in PVC conduit shall be measured as one length.
SCHEDULE 'A' PART-III (EXternal Elecrification) Material and Labour for Design,Supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, Indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts,3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded Copper conductor FRLS cable of adequate size (minimum 1.5 sq mm ), required civil works/anchoring bolts for grouting, PCC foundation etc with and including following:-
OUTGOING: (i) MCCB 125 Amps, 25 KA 4 pole, thermal magnetic release, Ics=100% Icu, with adjustable thermal setting, adjustable magnetic setting, quantity - 02 Nos ( 01 for SAW machine, 01 for 03 No 63 Amps plug & socket ) (ii) MCCB 100 Amps, 16 KA 4 pole, thermal magnetic release, Ics=100% Icu, with adjustable thermal setting, adjustable magnetic setting, quantity - 01 No (Frame bending machine) (iii) MCB TPN, 415 volts AC, 63 Amps ,"C" curve, 10 KA, 50 Hz, ISI marked quantity - 02 Nos (01 for weld pre heating m/c & 01 for 2 number plasma cutting m/c) (iv) MCB TPN, 415 volts AC, 32 Amps ,"C" curve, 10 KA, 50 Hz, ISI marked quantity - 01 Nos ( for 6 way VTPN DB).
Notes: 1. All MCCBs shall have spreader link, phase separator and adjustable rotary handle and MCB shall be of 'C' Series. 2. Panel manufacturers should have in house powder coating plant with minimum 8 tanks pre-treatment of MS sheet facilities, dust free spray paint booth. 3. Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with LT panel. 4. The panel manufacturer should have following certification: (i) CPRI certification, Degree of protection IP-54 (should have IEC:6143 (ii) CPRI certification short circuit withstand strength should be 50 KA rms for 1 sec with initial peak of 105 KA. (iii) CPRI certification rated current for short circuit not less than 5000 A with rated insulation voltage 660v. 5.Drawing of panel board should be got approved from GE before fabrication .
S&F plug in Box for rising main/Busbar trunking to branch out connection of 400Amps rated with MCCB 35KA, 4 pole, 50 Hz complete with all accessories complete all as specified and directed by Engineer in charge.
Supply and Fix sheet metal enclosure for provision & including of 32 Amps 05 pin Plug & socket, MCB TPN 32 Amps, 'C' curve, 415 volts, ISI Marked including all accessories complete all as specified and as directed by Engineer in charge.
Supply and Fix sheet metal enclosure for provision & including of 63 Amps 05 pin Plug & socket, MCB TPN 63 Amps, 'C' curve, 415 volts, ISI Marked including all accessories complete all as specified and as directed by Engineer in charge.
Supply and Fix sheet metal enclosure for provision & including of 125 Amps 05 pin Plug & socket, MCCB 125 Amps, 25 KA, 4 pole, thermal magnetic release, Ics=100% Icu, with adjustable thermal setting, adjustable magnetic setting, ISI Marked including all accessories complete all as specified and as directed by Engineer in charge.
Supply,laying,connecting and testing of XLPE Insulated Screened PVC bedded galvanized steel strip or wire armoured,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 Sqmm, 3.5 Core, confirming to IS-7098(part-I) laid in cable trenches / Duct / Wall / surfaces/Pipe including termination with brass compression glands and copper lugs as required at site complete all as specified and directed by Engr-In-Charge. Notes : (i) Testing for IR and continuity shall be recorded before and after laying of cable. (ii) Suitable glands and copper lugs for end termination of cables shall be provided by the contractor without any extra cost to the dept. (iii) No straight through joint shall be permitted.
Supply,laying,connecting and testing of XLPE Insulated Screened PVC bedded galvanized steel strip or wire armoured,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm, 3.5 Core, confirming to IS-7098(part-I) laid in cable trenches / Duct / Wall / surfaces/Pipe including termination with brass compression glands and copper lugs as required at site complete all as specified and directed by Engr-In-Charge. (10 mtr for frame bending machine & 45 mtr for SAW m/c) Notes : (i) Testing for IR and continuity shall be recorded before and after laying of cable. (ii) Suitable glands and copper lugs for end termination of cables shall be provided by the contractor without any extra cost to the dept. (iii) No straight through joint shall be permitted.
Material and labour for sub main wiring with 4 single core 10 Sq mm nominal area with 1100 Volt grade confirming to IS 694 (1990) PVC insulated unsheathed with 2 runs of 10 Sq mm multi stranded copper conductor cable (FRLSH) ISI Marked for continuous earth wire drawn in and including rigid, non metallic, PVC heavy duty concealed conduit (ISI marked) not less than 20 mm dia with fittings including cutting, chasing, for conduit and making good of walls etc complete all as specified and as directed. Note : Four runs of cable and two runs of earth cable in PVC conduit shall be measured as one length.
Material and labour for sub main wiring with 4 single core 06 Sq mm nominal area with 1100 Volt grade confirming to IS 694 (1990) PVC insulated unsheathed with 2 runs of 06 Sq mm multi stranded copper conductor cable (FRLSH) ISI Marked for continuous earth wire drawn in and including rigid, non metallic, PVC heavy duty concealed conduit (ISI marked) not less than 20 mm dia with fittings including cutting, chasing, for conduit and making good of walls etc complete all as specified and as directed. Note : Four runs of cable and two runs of earth cable in PVC conduit shall be measured as one length.
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level at any type of strata) with top edge of earth plate not less than 1.5 meters below ground level connected by 32 X 6 mm GI strip as earth lead by means of brass nuts and bolt,thimbles, check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20 mm graded stone aggregate,with fair finish,internal surface of concrete chamber shall be given internal dia 300mm x 300 mm ,15 mm thick plaster in CM 1:4,funnel with wire mesh ,RCC pit cover of 320 x 320 x 80 mm size (1:2:4) Type B1 using 20 mm graded stone aggregate reinforced with XPM and charcoal ,dust and common salt all as shown in electrical plate No 3 of MES SSR Part -1 (2009) and specified including and provision of GI strip upto 7.5 mtr long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade ,including all excavation and earth work and connecting the earthing strip to panel including testing on completion complete all as specified and directed. by Engr-In-Charge.
Note: (1) RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 kg/Sqm in lieu of CI cover. (2) Cost of additional GI strip more than 7.5 meter will be measured and paid seperately under relevant item
Supply and fix GI strip 32 x 6 mm buried in ground /wall above ground or any other indicated situation for loop earthing etc. as required all as specified and as directed by Engr- In- Charge.
Supply and Fix Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specified and directed by Engineer-in-charge.
Supply and Fixing Galvanised pipe ,100 mm bore dia light grade ISI Marked including all fitting like long bend ,sockets etc ,for cable protection laid in trenches /wall/roof all as specified and directed by Engineer-in-charge.
LEKSHMI ENGINEERS
Modern Engineering Co
VIJAY ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .