| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹34.9 L+₹1.6 L (4.50%)Accepted-AOC 0 CIVIL LINES TETARI BAZAR TETARI BAZAR NAUGARH SIDDHARTHNAGAR UTTAR PRADESH 272207 | SIDDHARTH NAGAR | UTTAR PRADESH | 272207 | L2 | Accepted-AOC M/s Deeksha Construction AOC Rs 3486504.67 Being L1 and reasonable | |
| 2 | L1₹35.5 LRejected-Finance | L1 | Rejected-Finance Other than L1 | |
| 3 | L3₹37.4 L+₹2.0 L (5.53%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹38.2 L+₹2.7 L (7.73%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Approved for opening of financial bid as documents are not completed as per NIT and also email reply is not receipt |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
21 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR PIN-273008
PROVISION OF TOILETS AT ASSEMBLY AREA AND OTHER SANCTIONED WORKS AT 4AFSB VARANASI UNDER GE (AF) GORKHPUR
2021_MES_481490_3
8861/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) GORAKHPUR
As per tender Documents
8 documents required · 8 mandatory
₹500
GE(AF) GORAKHPUR
₹82,000
Yes
24 Jan 2022
2 Dec 2021
22 Dec 2021
2 Dec 2021
21 Dec 2021
9 Dec 2021
60 days
Amount
Demolition of brick work masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide & not exceeding 1.5 metre depth for foundation etc and getting out, complete all as specified and directed.
M&L PCC type D-2 1:4:8 (40 mm graded aggregate) as in foundation filling, sub base and mass concrete complete all as specified and directed.
S&F mild steel TMT bar 10 mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for foundations, columns, beams and slabs hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
S&F mild steel TMT bar 8 to 10 mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping for stirrups hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
M&L for RCC (1:1 1/2:3) type A-1 using (20mm graded stone aggregate) as in column footing, plinth beam etc compete all as specified and directed.
M&L for use and waste form work to sides of concrete columns and similar works in vertical or to batter of fair finished surfaces complete all as specified and directed.
M&L for use and waste form work to sides of concrete foundation, footing, bases of columns and similar works in vertical or to batter of fair finished surfaces complete all as specified and directed.
M&L for use and waste form work to sides of concrete beam, side and soffits of plinth beam and similar works or to batter of fair finished surfaces complete all as specified and directed.
M&L for use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs, landings, Chhajja, and similar work n. exc. 200 mm thick, rough finished surface of complete all as specified and directed.
M&L for RCC (1:1 1/2:3) type A1 using 20 mm graded stone aggregate in Slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves etc complete all as specified and directed.
M&L for RCC (1:1 1/2:3 ) type A1 using 20 mm graded stone aggregate as in chajjas complete all as specified and directed.
M&L for RCC (1:1 1/2:3) type A1 using 20 mm graded stone aggregate as in columns, pillars, piers, posts and struts etc. complete all as specified and directed.
M&L for RCC (1:1 1/2:3) type A1 using 20 mm graded stone aggregate as in beams, cantilevers, bressumers, lintel over 1.5 m span etc. complete all as specified and directed.
M&L for brick work with sub class 'B' bricks old size straight or curved on plan exceeding 6 metre mean radius built in CM 1:6 complete all as specified and directed.
M&L for brick work with sub class B bricks old size laid straight or curved in plan any radius half brick thick wall built in cement mortar 1:4 complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces and of brick work or concrete surface finishing the surface even and smooth without extra cement complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:4 mixed with water proofing compound, finished even and smooth without using extra cement complete all as specified and directed. Note:- Water proofing compound shall be measured and paid separately as supply only.
M&L 5 mm thick rendering on concrete surfaces such as sides of roof beams, soffits of roof slab (ceiling) etc in CM 1:3, finished fair & smooth without using extra cement all as specified and directed .
M&L for rendering 5mm thick in CM 1:4 on ceiling surface and finishing the surface even and smooth without extra cement complete all as specified and directed.
M&L 75mm thick cement concrete type D2 (1:4:8) using 40 mm stone aggregate as in sub base of floor all as specified and directed.
M&L 30 mm thick cement concrete type B-0 (1:2:4) using 12.5 mm stone aggregate as in sub base of floor tile all as specified and directed.
M&L 20mm thick screed bed or bedding layer of mortar in CM 1:6 for laying floor finishes neat cement slurry with 3.00 kg of cement per sqm complete all as specified and directed.
S&F non-skid ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles size (300mmX 300mm), in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for glazed tiles as in vertical surfaces size (450 x 300x7mm) thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and directed.
S&F in 150 mm long aluminum anodized barrel tower bolt of extrude section ISI marked fixed with screw complete all as specified and directed.
S&F aluminum handles, cast type anodized (size of handle 125mm) fixed with screw complete all as specified and directed.
S&F Factory made PVC single door frame of size 50x47 mm with a wall thickness of 5 mm thick sheet moulded teak face colour sheet reinforced with 19mmx19mm square tube having wall thickness 19 gauge complete all as shown in sketch on page 160 of SSR 2010 Part-II.The door frame to be fixed to the wall using MS screw 75 mm long with PVC fastener complete as per manufacturer's and as specified.
S&F factory made solid panel PVC door shutters 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with 5 mm thick pvc sheet strip 20 mm wide struck inside with solvent cement for stiles and 5 mm thick PVC sheet for top rail, lock rail, bottom rail on either side and 10 mm (5mmx2mm)thik,20 mm wide cross PVC sheet as gap insert for top and bottom rail paneling of 5 mm thick teak face colour PVC sheet to be fixed in MS frame welded/sealed to the stiles and rails with 5mmx30mm PVC sheet beading and jointed together with solvent cement complete all as shown in drawings complete all as specified and directed.
M&L for 10 mm thick rendering on fair faces of brick or on concrete surface in CM 1:3 finished surface even and smooth without using extra cement mixed with liquid water proofing compound @ 200 ml per 50 kg of cement bag complete all as specified and directed. Note : WPC will be measured and paid separately.
M&L for roof treatment for in accessible / accessible roof including cleaning the roof surface and applying bituminous primer @ 0.20 kg per sqm , providing and laying 3 mm thick APP water modified water proofing membrane not less than 4 kg per sqm reinforced with non woven polyster mat weighing not less than 800 N per sqcm trearing not of 180 N (by torch application method) with minimum of 10 cm side laps and 15 cm end laps by application of torch applying a coat of blown grade hot bitumen 90/15 grade over the membrane @ 1.20 kg /per sqm complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and apply two coats of oil bound distemper with putty Birla white complete all as specified and directed.
M&L for preparation of newly plastered ceiling surfaces and apply three coats of white lime wash complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and apply two coats of Cement base paint with 1mm thick Birla putty white complete all as specified and directed.
Supply only integral liquid water proofing compound complete all as specified and directed. Make:- Dr Fixit Pidiproof LW+ or equivalent in specified make.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc. 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material to a distance exc 250 mtrs and n.exc. 500 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for concrete bed to drain pipes laid in trenches including packing under and hunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) for 150mm bore pipe complete all as specified and as directed.
M&L for 150 mm bore reinforced concrete pipes, class NP-2 laid and jointed complete with collars complete all as specified and as directed .
M&L for brick work with sub class 'B' bricks old size straight or curved on plan exceeding 6 metre mean radius built in CM 1:4 complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) in benching and the like including weathering, slightly rounded or chamfered angles and throating as directed and necessary formwork complete all as specified and as directed .
M&L for providing, precast reinforced cement concrete as in manholes covers 1:2:4 type B-1 (using 20mm graded crushed stone aggregate )set in cement mortar 1:4 complete all as specified and as directed . (Reinforcement shall be measured and paid for separately) .
M&L for mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for mild steel framed work as in framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., n exc 10 kg each brackets, conforming to Fe 290-0 grade E-165 complete all as specified .
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20mm crushed stone aggregate) surface smooth finished and reforming benching as required for internal dia of pipe 150mm complete all as specified and as directed.
S&F GI tubing, 15 mm bore 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F GI tubing, 20 mm bore 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F PVC (SWR) pipes 110mm external dia double socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) pipes single scoketed in any length with rubber ring joints fixed to walls of 110 mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius for 110 mm bore provided complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or unequal of 110mm dia complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or unequal of 75mm dia complete all as specified and directed.
S&F PVC(SWR) bends suitable for 75 mm external dia complete all as specified and directed.
S&F PVC(SWR) pipes, 75 mm external dia double socketed in any length with rubber joints, fixed to walls/floor complete all as specified and directed.
S&F PVC waste pipe 32mm dia, 60 cm long for WHB/ Urinal with long screw shanks and fly nuts, flanges end bedded in red lead cement and other fixed complete all as specified and directed.
S&F 10 Ltrs capacity PVC flushing cistern valveless, syphonic action type, low level, white, with inlet, ball wall, float and handle including brackets and connecting to pipes and fixing of chain and pull or lever complete all as specified and directed.
S&F grating doom of size 125mm dia with waste hole of PTMT (min weight 50grams) complete all as specified and directed.
S&F rotational molded polyethylene water storage tanks (cylindrical vertical with threaded lead) hoisted and fixed in position all as specified in SSR Part-I of Capacity 1000 litres complete all as specified and directed.
S&F in 20mm PVC Nipple suitable for HDPE Water tank (Min Wt 15mm-38gms) complete all as specified and directed.
S&F in 15mm PVC Nipple suitable for HDPE Water tank (Min Wt 15mm-38gms) complete all as specified and directed.
S&F ball brass valves high pressure with polyethylene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to 20 mm bore complete all as specified and directed.
S&F vitreous China wash basin, angle back, size 600x480mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed.
S&F vitreous China bowl urinal flat back, size of 465x 355x265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed.
M&L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete alll as specified and directed.
M&L PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified.
S&F 15mm dia bib taps chromium plated fancy type with crutch or butter fly handle, screwed down screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F vitreous china squatting pan 'Orissa' pattern size 580x440 mm white integral foot rest(excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F vitreous china wash down water closet pan (pedestal pattern with including trap, seat cover, including connection to trap /drain and to flushing pipe anti syphonage pipe etc complete including making good floor complete all as specified and directed.
S&F concealed stop valves 15mm bore dia fancy type, chromium plated, with long shank and cup, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F stop valves 15mm bore dia fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F stop valves 20 mm bore dia fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F PVC connections 15 mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F 15mm bore pillar taps, CP bras with chromium plated type screwed down high pressure, with chromium plated screwed shanks and fly nuts complete scewed for iron pipe and fixed complete all as specified and directed.
S&F looking mirror of 600x450 mm with PVC moulded frame with 6mm thick hard board backing complete all as specified and directed.
S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L PCC (1:2:4) type B2 using (40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for steel work in tubular post / trusses (square/ rectangular) rafter/ purlin including special shaped washer, hollow section, angle iron, flat iron for fixed independently connecting purlin, rafters, MS plate as reqd forming holes bolted and welded attachment and curved shaped by welding making joint less by filling including cutting etc complete all as specified and directed.
M&L for 0.50mm total coated thickness (0.45 mm base metal thickness) pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet having tensile strength of 550 Mpa as an roof covering /cladding to wall fixed with self tapping screws as specified complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L applying 2 coats of black Japan paint over a coat of red oxide zinc chrome primer on steel surfaces over 10 cm girth including preparation of surface complete all as specified and directed.
M&L 100 mm thick cement concrete type D2 (1:4:8) using 40 mm stone aggregate as in sub base of floor all complete all as specified and directed.
M&L 30 mm thick cement concrete type B0 (1:2:4) using 12.5 mm stone aggregate as in sub base of floor tile complete all as specified and directed.
M&L for heavy duty full body paving tiles 300x300x 10mm thick, (for external use as in parking) of approved pattern & design confirming to IS 4457: 2007, set, jointed and pointed in neat cement slurry in floors over and including 15mm thick screed bed in cement and sand mortar (1:4) complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and directed.
Dismantling asbestos cement plain or corrugated sheeting incl ridges any gauge/ thickness nainital or similar pattern as in roof covering complete all as specified and directed.
M&L for 0.50 mm total coated thickness (0.45 mm base metal thickness) pre-painted galvalume aluminum zinc coating GI based plain steel sheet having tensile strength of 550 Mpa as in valley gutter, ridge of roof covering /cladding to wall fixed & fascia of roof etc. with self tapping screws as specified complete all as specified and directed.
S&F rolled mild steel section in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde E-250) quality-A complete all as specified and directed.
S&F Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks(stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chins hand made sliding bolts, clamps. Hold fast wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or faters knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe.290, Gde-E-165.
M&L for preparation of old painted steel surface over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F steel almirah fixed on wall with 4 Nos 10mm dia 100 mm long fasteners, Almirah shall be of size 760mm long, 440 mm wide and 900 mm high made of 1mm thick mild steel, front shutter shall have two levers, 100mm CP handles shall be provided on shutter, three way locking device shall be front shutters, two coat synthetic enamel paint over one coat of primer and all specification shall be as per FD-1032 and as per sample kept in AGE(AF) varanasi complete all as specified and directed.
S&F anodised aluminium frame for windows Ventilators and cupboards with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S&F anodised aluminium window and ventilator/ cupboard shutter with lock, fixed type without sash bar, aluminium section weighing 0.55Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed.
S&F 4mm Sheet glass in metal frame, ordinary quality n exc 0.5 sqm in each pane complete all as specified and directed.
Roughening surfaces of old concrete floor by sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 Kg of cement per Sqm complete all as specified & directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate complete all as specified and directed.
M&L for 30mm thick PCC 1:2:4 type B-0 using 12.5mm graded mechanically crushed stone aggregate as in floor finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying three coat of white wash complete all as specified and directed.
Dismantling of timber scantling n.ecx 40sqcm in section in any position framed work complete all as directed.
Dismantling wrought iron or MS work of any description not otherwise provided for complete.
Taking down cement or cement lime plaster of any description on brick or stone/concrete walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
Demolition of cement concrete un-reinforced of any position not otherwise specially provided or portion to be ordered complete all as specified and directed.
Demolition of reinforced concrete of any description & in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Taking down chawkhats or frame with shutter (without taking out shutter from the frame n.exc 1.50 Sqm each and removing from site complete all as specified and directed.
Taking down chawkhats or frame with shutter (without taking out shutter from the frame exc. 1.50 Sqm but n.exc 4.00 Sqm each and removing from site complete all as specified and directed.
Excavation in post holes (or similar holes) each n.exc 0.5cum getting out, returning, filling in watering and ramming earth or broken rubble mixed with earth around in layers n.exc 25cm thick in soft/ loose soil, making good surface and disposal of surfaces spoil to a distance not exc 50 Mtrs complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregate as in benching, padding, coping etc including necessary form work complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces and of brick work or concrete surface finishing the surface even and smooth without extra cement complete all as specified and directed.
Material and labour for machine cut Pre Polished Kota stone slab 18 to 20mm thick (minimum size 30cmx 45cm) as in flooring, laid over and including cement screed bed 20 mm thick in cement mortar 1:4, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite polishing complete all as specified and as directed.
M&L for machine cut pre polished Kota stone slab 18 to 20mm thick (minimum size 30cmx 45cm) as in skirting/ dado or on vertical surfaces laid over and including cement screed bed 10 mm thick in cement mortar 1:4, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite polishing complete all as specified and as directed.
S&F steel windows, ventilator with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded complete all as specified and directed.
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square n. exc 0.50 Sqm in each panes complete all as specified and directed.
Roughening surfaces of old concrete roof by sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 Kg of cement per Sqm complete all as specified & directed.
M&L for 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded mechanically crushed stone aggregate as in roof surface, surface finished even and fair, mixed with liquid water proofing compound @100 ml per 50 Kg of cement bag complete all as specified and directed. Note: WPC will be measured and paid separately.
M&L for 10 mm thick rendering on fair faces of brick work or on concrete surface in CM 1:3 finished surface even and smooth without using extra cement mixed with liquid water proofing compound @100 ml per 50 Kg of cement bag complete all as specified and directed. Note: WPC will be measured and paid separately.
M&L for cutting out cracks of roof in V-Section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
Resecuring or easing & adjusting without taking down shutters of any description exc 1 sqm and n.exc 2sqm each complete all as specified and directed.
M&L for water proofing treatment to roof surface complete all as specified and directed with the followings:- (a) Applying bituminous based primer confirming to IS:3384-1965 @ 0.30 litre per sqm (b) Applying a tack coat of hot blown bitumen grade 85/25 confirming to IS:702 @ 1.20 Kg per sqm (c) Applying APP modified polymeric membrane of weight not less than 3.6Kg per sqm laid and bonded to the sub strata by heat process, over laps of 100mm shall be sealed/fused by flame torch application as per manufacturer instructions. (d) Blinding with coarse sand dry @ 0.50 to 1.00 Kg/sqmts dusted over bitumen and applying one coat of aluminium paint.
M&L concealed wiring for one light/fan point controlled by one switch point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken including provision for modular Sunken box, cover plate with frame, including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete all as specified and directed. Note :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
All as per item No. 119 above but for one socket outlet 3/5 pin 5/6 amps independent controlled by one switch on same board.
All as per item No. 119 above but for one socket outlet 3/5 pin 5/6 amps independent controlled by one switch.
S&F modular switch single pole 1 way, 1 module, 6 Amp complete all as specified and directed.
S&F modular socket out let multipurpose 6A -2/3 pin, SP 1 way 2 module complete all as specified and directed.
S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed.
S&F factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
S&F MCB, SP, 6 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, SPN, 40 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F 10 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:-Havells Cat part No. ENDURA LINE ARNE OBS 10W LED865SPCWH or equivalent in Bajaj/ Philips/ CG/ WIPRO
S&F 20 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No. ENDURA LINE ARNE OBS20WLED865S PCWH or equivalent in Bajaj / CG.
S&F 10 watt LED 6000K bulk head light fitting complete all as specified and as directed. Make:- Havells Cat part No. LHEXCFP7PN5W010 or equivalent in Bajaj /CG.
S&F exhaust fan single phase 230/240 volt AC 400mm sweep, with painted louvers, metal body, including cutting holes of suitable size in wall, grouting of nuts and bolt etc if required for fixing fan and making good to match the existing surface and making connection with twisted copper flexible wire 23/0.0076mm including taking down old fan and deposited in MES store complete all as specified and directed. Make: Havells/Bajaj/CG.
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for cable trench complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note: Punned thickness shall be measured for the purpose of payments.
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
Boring of holes horizontally for laying of 40/50 mm dia pipe (minimum depth 1200mm from top level) under road, Pavement, hard standing complete all as specified and directed.
S&F 40mm bore GI pipe, light grade with all fittings laid in trenches, road crossing and fixed to walls, on poles etc for cable protection complete all as specified and directed.
Supply, laying and testing 10Sqmm, 2.0 Core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve complete all as specified and directed Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items.
M&L for concealed point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision for modular Sunken box, cover plate with frame including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note:- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Sunken box, cover plate with frame, Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
S&F modular switch single pole 1 way, 1 module, 16 Amp complete all as specified and directed.
S&F modular socket out let multipurpose 6A/16A-2/3 pin, SP 1 way 2 module complete all as specified and directed.
M&L for concealed sub main wiring with 2 Nos single core PVC insulated unsheathed 6.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 4.0 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 6.0 sqmm conductor cable, 1 No 4.0 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
S&F air circulator fans complete of metal body and copper winding fan motor, 230 volts, 50Hz, single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified and directed. Make:-Bajaj Model Supreme plus or equivalent in other specified makes
Supply, laying and testing 16Sqmm, 2.0 Core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve complete all as specified and directed. Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items.
S&F factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
Taking down carefully copper/aluminium point wiring light/ fan/ bell/ socket or power complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc are to be measured separately) and/or drawing out from existing conduit/ batten and making good disturbed surfaces of walls/ floors/ ceilings complete all as specified and directed.
M&L for concealed point wiring for one light/fan point controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed. Note:- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
All as per item No. 148 above but for one socket outlet 3/5 pin 5/6 amps independent controlled by one switch on same board.
All as per item No. 148 above but for one socket outlet 3/5 pin 5/6 amps independent controlled by one switch.
M&L for point wiring with (FRLS) Fire retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of GI terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Fire retardant low smoke PVC insulated copper earth conductor 1.50 sqmm connected to common earth and earth dolly complete for 3/6 pin 15 Amps socket outlet on independent board complete all as specified and directed. Note:-(i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii) Switches, Socket outlet, shall be measured and paid separately.
S&F switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed.
S&F switch piano, flush type 15 amp, single pole, one way 240 volt complete all as specified and directed.
S&F socket outlet, 3/5 pin, 5/6 amps flush type 240 volt complete all as specified and directed.
S&F socket outlet, flush type, 2 in 1, 3 pin 5 & 15 Amps, 230 Volts, multipurpose complete all as specified.
S&F fan regulator electronic step up type, SP 230 volt complete all as specified and as directed.
S&F lamp holder polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and directed.
S&F LED lamps 12 watts complete all as specified and directed. Make:- Havells Cat part No. LHLDEUEEMC8R012 or equivalent in Bajaj / CG.
S&F ceiling fan complete with all accessories of capacity 230V, 1200 mm sweep, BEE 5 star rating complete all as specified and directed. Make: Havells, Model No. ES 50 Premium 5 or equivalent in Bajaj/ Crompton.
Taking down old unserviceable light fittings conventional type from wall surface / ceiling or any position and making good the disturbed surfaces all as specified and directed.
Taking down old unserviceable MCB DB complete all as specified and directed. Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces.
Taking down old unserviceable MCB complete all as specified and directed.
PANDEY TRADERS
Sudularush Construction
Saraswati Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .