Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance G 1 1154A MANSAROVER PARK SHAHDARA DELHI DELHI 110032 | SHAHDARA | DELHI | 110032 | Admitted-Finance |
| 4 | Admitted-Finance NONE | Admitted-Finance |
| 5 | Admitted-Finance 975 E LOHIYA GALI NO 4 BABARPUR DELHI 110032 | DELHI | SHAHDARA | DELHI | 110032 | Admitted-Finance |
Tender Value
₹10.1 L
EMD Value
₹20,190
Closing Date
2 Apr 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (E)
O/o EE (E), PWD NES/ M-251, LM Bund Road, Ramesh Park, Delhi-92
1 EOR to EI and Fans at SKV No-1, MS Park, Delhi. (School ID- 1106020) 2 EOR to EI and Fans at G.G.S.S.S, Sunder Nagri, Delhi (School ID- 1106264)
2022_PWD_219701_1
122/EE (E)/PWD NE and Shah. Elect. Divn./2021-22
Open Tender
Electrical Works
Item Rate
30 days
SKV MS Park
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹20,190
6 Apr 2022
26 Mar 2022
2 Apr 2022
26 Mar 2022
2 Apr 2022
26 Mar 2022
30 days
Amount
Rewiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in the existing surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. GROUP C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. GROUP C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 4 sq. mm
6 x 4 sq. mm
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6-way, Double door
12-way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Single Pole and neutral
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying, Installation, Testing & Commissioning 18 to 20 watt 1200 mm long high efficiency LED linear batten Luminaries having aluminium extruded housing and polycarbonate diffuser within built APFC driver having efficiency of driver 85% power factor > 0.90, THD <20% with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency 120 luman per watt and colour temperature of 6000 K, CRI >80 including connect ion with 1 5 sq. mm PVC insulated copper conductor FRLS cable i/c dismantling of existing old fitting if any etc. complete as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, ISI marked, energy saving ceiling fan B, 3 Nos. blades, 30 cm long down rod, 2 Nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CMM/W) minimum 26.85 Air delivery minimum 215 CMM, 350 RPM THD less than 10%, and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc. complete as required.
Supplying and fixing LED bulk head fitting 10 to 12 Watt energy saving new generation 10 W LED IP 65 bulkhead luminaire with opal diffuser, decorative bulk head LED luminaire comprising of high brightness complete with accessories etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying, installation, testing and commissioning of Following Capacity Split AC suitable for operation on 230 Volt, 50 Hz Single Phase AC supply with capable to perform cooling, dehumidification, filtering with cooper pipe 3 mtr. Copper tubes & connecting wires/cables with outdoor stand etc. complete as required. 1.5 T R Nominal 3-star Rating
Supply, Installation of 5 KVA Automatic Line voltage correctors and wall mounted type for domestic use, copper wound completes with the voltmeter etc. complete as required.
Supplying, Installation, Testing and Commissioning of Water dispenser with hot and cold i/c testing commissioning etc. as required.
Supplying, Installation, Testing and Commissioning of stainless-steel storage type water cooler 150/150 Ltr. capacity, fully stainless steel suitable for operation on 230 V+10% 50 Hz single phase AC supply i/c making water line and electrical connection i/c dismantling the existing as required. etc. as required.
Supplying, Installation, Testing and Commissioning of Reverse Osmosis (R.O. System) water Purification unit as per Technical specification attached i/c Providing suitable wall/floor mounting bracket, water connection from the available water inlet point with suitable C.P. angle valve and outlet upto the nearest drain with suitable PVC pipe, complete etc. as required. Capacity: - 50 LPH Capacity Membrane: - 75/100 GPD (4 Nos) Input Power Rating: - 230 Volt AC, 50 Hz % of Rejection in TDS - 90% (Approx.) Indicator: - TD level of output water Tank full indication Audio Beep and No water Auto Flush Timer Dry Run Protection U.V. Sterilization
Less on account of buy back of dismantle material. Assorted Fitting Batten/Box type/2x2 fitting/bulkhead
Assorted Switch Socket, DP, TP, FP, SPN MC, Wire, M.S Box, XLPE Cable, GI wire, Pole Box
Assorted Ceiling fan
Krishna Electreical Works
Shri Bankey Bihari Electricals
V A Associates
DRP Air Conditioning Work
M/s Bhagwat Associates
A K Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .