Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹30.6 L+₹1.7 L (5.84%)Rejected-Finance | L2 | Rejected-Finance Not Lowset | |
| 3 | L3₹33.6 L+₹4.7 L (16.3%)Rejected-Finance | L3 | Rejected-Finance Not Lowset | |
| 4 | L4₹35.8 L+₹7.0 L (24.1%)Rejected-Finance | L4 | Rejected-Finance Not Lowset | |
| 5 | L5₹37.3 L+₹8.4 L (29.3%)Rejected-Finance | L5 | Rejected-Finance Not Lowset |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
12 Oct 2021, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIRS/ MAINTENANCE REPLACEMENT OF UNSERVICEABLE INTERNAL ELECTRICAL FITTINGS MCBS DBS, MCCBS, SPLIT/ WINDOW ACS, COOLERS AND ITS ACCESORICES REWIRING AND RENEWAL OF UNSERVICEABLE E/M ITEMS AND OTHER ALLIED WORKS AT DLRL AND ADJOINING AREA HYDERABAD
2021_MES_474898_1
GE I KBAGH TOKEN 46 OF 2021 2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹98,000
Yes
12 Nov 2021
13 Sept 2021
14 Oct 2021
13 Sept 2021
12 Oct 2021
27 Sept 2021
14 Sept 2021 - 22 Sept 2021
Amount
Taking down carefully of any type point wiring light fans socket or power complete fitting such as switch ceiling roses, pendent, regulator, sockets etc removing material and making good disturb surface of wall floor etc complete all as directed.
M&L for point wiring complete with 1.5 Sqmm PVC insulated unsheathed single core multi standard copper conductor 1100 V grade drawn through in and including 20 mm dia in stove enamelled steel conduit concealed on walls/ in existing Conduit on Ceiling and Terminated to sunken box of modular type including white cover plates suitable for fixing switches, sockets etc including 1.5 Sqmm PVC insulated Copper conductor cable as earth continuity conductor and connecting to common earth dolly and taking down old one complete all as specified and directed for the following:-
One light point controlled by one way modular switch 6 Amps
One ceiling fan point /Exh fan point controlled by one 5 Amps one way switch and regulator
One 3 pin 5 Amps switch socket outlet point on independent board
One 3 pin socket outlet 5 Amps on the same board with other switches.
M&L for point wiring complete with 2.5 Sqmm PVC insulated unsheathed single core multi standard copper conductor 1100 V grade drawn through in and including 20 mm dia PVC conduit concealed on walls/ in existing Conduit on Ceiling and Terminated to sunken box of modular type including white cover plates suitable for fixing switches, sockets etc including 2.5 Sqmm PVC insulated Copper conductor cable as earth continuity conductor and connecting to common earth dolly and taking down old one complete all as specified and directed for 3 in one 3 pin socket outlet 15 amps, independent:- Make:- Conductor: Finolex/Finecab/Polycab/Plaza PVC Conduit: Sudhar/Diamond/Avon
S&F modular switch one way 6 amps 1 module
S&F modular switch one way 16 amps 1 module
S&F modular fan step type regular two module
S&F modular socket out let 6 Amps 230 volts AC 3 pin multipurpose type complete all as directed.
S&F modular socket out let 6/16 Amps multipurpose complete all as directed.
S&F Lamp holders insulated body card grip pattern suitable for batten/angular complete all as specified and directed.
S&F ceiling rose two to three terminal surface backallite type AC 50Hz 230 volts complete all as specified and directed
Supply & Fixing LED fitting indoor tube light batten type,18/20W, Lumen output 2000 Lm, 230v Energy efficient, with Drive, connector block, etc. complete with all accessories internally pre-wired and including connecting up 3 core sheathed copper flexible cable 1.5 sqmm up to light fitting. Make: Philips /Crompton/jaguar
M&L for sub main wiring complete with 4 runs of 4 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawn through surface or concealed in and including PVC conduit of appropriate size and connecting terminal ends including provision of 2 runs of 4 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor for earth continuity conductor and connecting to earth dolly including taking down old unserviceable sub main wiring complete all as directed. Note: 6 runs of 4 Sqmm cable and one run PVC conduit shall be measured as one length.
All as per srl item No.12 here-in-before but with 4 runs of 6 sqmm and 2 runs of 6 sqmm, complete all as directed. Note : 6 runs of 6 Sqmm cable and one run PVC conduit shall be measured as one length.
All as per srl item No. 12 here-in-before but with 4 runs of 10 sqmm and 2 runs of 10 sqmm, complete all as directed. Note: 6 runs of 10 Sqmm cable and one run PVC conduit shall be measured as one length.
M&L for sub main wiring complete with 2 runs of 4 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawn through surface or concealed in and including PVC conduit of appropriate size and connecting terminal ends including provision of 1 run of 4 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor for earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring complete all as directed. Note: 2 runs of 4 Sqmm cable, 1 run of 4 Sqmm earth continuity conductor and one run PVC conduit shall be measured as one length.
Dismantling of existing unserviceable MCB distribution board and S&F sheet metal enclosure DB concealed with wall having facility to fix MCCB as incomer and MCBs in outgoing, TP vertical type 8 way of double door, complete fitted with bus bars, neutral links, G frame including S&F 3 pole MCCB 125 Amp capacity, 50 Hz, 16 KA Breaking capacity, blanking plates including making good disturbed surfaces complete all as specified and directed.
Dismantling of existing unserviceable MCB distribution board and S&F sheet metal enclosure DB concealed with wall having facility to fix MCCB as incomer and MCBs in outgoing, TP vertical type 4 way of double door, complete fitted with bus bars, neutral links, G frame including S&F 3 pole MCCB 100 Amp capacity, 50 Hz, 16 KA Breaking capacity, blanking plates including making good disturbed surfaces complete all as specified and directed.
S&F electronic Ballast choke suitable for 36/40 watts fluorescent tube light fittings including taking down old defective choke and refixing in same position, complete all as directed.
S&F of LED 36 watts, 4 pin, L type lamp by taking down unserviceable lamp from the fitting of any height and fixing new one complete all as directed.
Earthing with GI earth plate electrode 600x600x6 mm buried directly in ground vertically to a depth of not less than 2.25 mtrs below ground level with the top edge not less than 1.5 mtrs below ground level connected to GI earth strip of size 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by40mm dia GI pipe light grade including necessary excavation and earthwork, PCC 1:3:6 type C2 (using 40mm graded stone aggregate) for earth pit and RCC covers 1:2:4 type B1 (using 20mm graded stone aggregate) with 8mm dia TMT bars @ 100mm C/C both way, 20mm dia GI watering pipe medium grade, funnel, mesh, salt, charcoal complete and frame work complete all as shown in electrical plate No. 3 of MES Sch `A' Part - I complete all as directed. Note :- GI strip beyond 7.5M length shall be measured and paid separately.
S&Fsheet metal AC earth plug and socket of 3 pin with MCB SP 5 to 20 Amps 240 Volts, including taking down old one, complete all as directed.
S&F sheet metal AC 3 Phase earth plug and socket of 3 pin with neutral with and including MCB TPN 32Amps operating on 415V, 50Hz AC supply, including taking down old one, complete all as directed.
S&F of MCB SP 5-20 Amps capacity including taking down unserviceable one complete all as directed
S&F of MCB SPN of 40Amps capacity complete all as directed.
S&F isolator 4 pole 100 Amps 415 Volts including taking down existing unserviceable Isolator complete all as directed.
S&F in repairs MCB TPN 63 Amps 415 Volts complete all as directed.
S&F in repairs MCB TP 40 Amps 415 Volts complete all as directed.
S&F of MCB DB SPN 4 way double door type with 200 Amps rating Busbar and suitable arrangement for mounting MCB's including taking down old one complete all as directed by Engr-in-charge.
S&F of MCB DB SPN 8 way double door type with 200 Amps rating Busbar and suitable arrangement for mounting MCB's including taking down old one complete all as directed by Engr-in-charge.
S&F of MCB DB SPN 12 way double door type with 200 Amps rating Busbar and suitable arrangement for mounting MCB' including taking down old one complete all as directed by Engr-in-charge.
S&F LED 2'x2' type recess mounted lumniaire 35/36 Watt, Lumen Output -6500 lm , with Drive, connector block, etc. complete with all accessories internally pre-wired and including connecting up 3 core sheathed copper flexible cable 1.5 sqmm up to light fitting and connecting testing complete fixed on false ceiling complete. Make: Philips /Crompton/jaguar
S&F LED Street light fitting with IP66 type protection, 90W, CCT (K) not less than 5700 Lm , 50 Hz and housing epoxy powder coated dia casted aluminuim housing with bright anodised reflector and enclosed with heat resistant and toughened glass front visor including constant current driver suitable for 140-270V AC , fixing on pole/Wall/bldg (including adjustment for up or down in pole or wall) side mounitng suitable for 40-60mm OD pipe and provn of 3 core PVC insulated PVC sheathed copper conductor multistranded wire upto fitting complete all as specified and directed. Make: Philips /Crompton/jaguar
Supply & Fixing LED fitting.indoor type 35W (1'x 4'), 230v Energy efficient, Recess/ Surface mounted ,with Drive , connecter block, etc. complete with all accessories internally pre-wired and including connecting up with twin core hvisted flexible copper conductor cable with suitable size. Make:- Wipro Model NO CRCO13R038HP57 or equivalent in Philips.
Supply and lay XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade cross sectional area 25Sqmm 3.5 Core including takingdown existing unserviceable LT cable complete all as directed by Engineer-in-Charge
Supply and lay cable XLPE of size 16 Sqmm, 4 core multistranded aluminium conductor Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade including taking down existing XLPE cable complete all as directed.
Supply and lay cable XLPE of size 10 Sqmm, 2 core multistranded aluminium conductor Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade including taking down existing XLPE cable complete all as directed.
Excavation in trenches n.exc 1.5m wide and n. exc 1.5m in depth; for pole foundation or for cable laying, etc. n exc 10 sqm on plan and n exc 1.5m in depth and getting out in any type soil complete all as specified and directed.
M&L Returning, filling in including spreading, levelling watering and well ramming in layers not exc 25 cm thick, using soil complete all as directed.
Removing excavated material to a distance n. exc 50 m and depositing where directed at a level n. exc 1.5M above the starting point complete all as specified and directed.
M & L for laying of bricks common burnt clay building bricks, sub class 'B' designation 75 complete all as specified and directed.
Supply and spread approved natural, clean dry river sand for cushioning of cable laid in trenches complete all as specified and directed.
S&F of GI tubing of light grade with necessary fitings of size 50mm bore laying in trenches,floor/fixing on wall or roof complete all as specified and directed.
Servicing of capacitor panel upto 400 KVAR and checking of capacitance of capacitor including control & power wiring complete cleaning of spares parts including testing of relay & contactor, tighting of nuts/bolts etc of any capacity after taking shutdown as per electrical safety norms complete all as directed.
S&F in repairs capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 5 KVAR capacity Make : L& T/Neptune
Supply and fix in repairs capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 10 KVAR capacity. Make : L& T/Neptune
Supply and fix in repairs capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 20 KVAR capacity. Make : L& T/Neptune
S&F FTL starter of capacity 40W, operating on 230V, AC supply including taking down old unserviceable starter complete all as directed. Make :- ANCHOR/ CG
S&F ceiling fan regulator electronic stepped type operating on 230V, AC supply including taking down old unserviceable regulator complete all as directed. Make: - ANCHOR/ CG/ USHA/MARU
S&F switch socket 5 pin 15 Amps multipurpose type including taking down old unserviceable switch socket, complete all as directed Make : Anchor/Maru/Leader
S&F switch socket 3 pin 5 Amps multipurpose type including taking down old unserviceable switch socket, complete all as directed Make :- ANCHOR / LEADER / MARU
S&F MCCB 100 Amps, 16KA 3-Pole type, including all arrnagement for mounting and testing, operating on 415V, 50Hz , AC supply, including taking down old unserviceable MCCB complete all as directed . Make : Standard/Havells/C&S/L&T
S&F MCCB 125 Amps, 16KA 3-Pole type, including all arrnagement for mounting and testing, operating on 415V, 50Hz , AC supply, including taking down old unserviceable MCCB complete all as directed. Make : Standard/Havells/C&S/L&T
S&F MCCB 200 Amps capacity 4 pole 25 KA breaking capacity including taking down complete all as directed. Make : Standard/Havells/C&S/L&T
S&F MCCB 250 Amps capacity 4 pole 25KA breaking capacity including taking down complete all as directed. Make : Standard/Havells/C&S/L&T
S&F MCCB of 400 Amps capacity 4 pole 35KA breaking capacity including taking down complete all as directed. Make : Standard/Havells/C&S/L&T
S&F sheet metal enclosure suitable for fixing of MCCB's, 3P/4P of any type and capacity including taking down old unserviceable sheet metal enclosure complete all as directed.
S&F Capacitor of 2.5 mfd including taking down old capacitor complete all as directed. Make: TIBCON/DADA /CAPCO/CG
S&F Capacitor of 3.15/4 mfd including taking down old capacitor complete all as directed. Make . TIBCON/DADA /CAPCO/CG
S&F for Galvanized iron strip 25 x 4 mm buried in ground/fixed on wall including taking down unserviceable GI strip complete all as directed.
Taking down FTL/HPSV/HPMV/CFL fitting of any capacity after dismantling from any height of pole/walls /any location and detecting the fault in the fitting by checking the accessories and wiring, refixing the same after repairs complete all as directed. Note :- Items like HPSV/MH ballast ,lamp, capacitor ,etc shall be measured and paid separately under relevant items of this schedule.
All as per item No.60 here-in-before but 250 Watts complete all as directed.
All as per item No.60 here-in-before but 400 Watts complete all as directed.
S & F in Replace of Lamp tubular suitable for MH 250W fitting.
S & F in Replace of Lamp Tubular suitable for MH 400W fitting.
S & F in Replace of Electronic Ignator for metal halide lamps (super imposed ignator )150/250/400 complete all as directed
S & F in Replace of LED tube (T-8) 4 feet length,20/18W including taking down unserviceable tube complete all as directed. Make: CG/Wipro/Surya
Disconnecting and taking down old exisiting Bus bar insulator from VCB after taking shutdown complete breaker removing, Supply and fixing New Bus bar insulator in position with all connection complete testing and commissioning 11000V of capacity 1250 Amps on existing aluminium bus including cleaning with CTC and solution insulation of bus bar complete all as directed.
M&L for finding cable fault by using fault Locator machine under the trench/inground/in air etc complete all as directed.
S & F in Replace of digital type volt meter suitable for Eleven KV breaker ranging (0-11KV) suitable for auxilary voltage 230 volts complete including taking down old unserviceable Voltmeter complete all as directed.
S & F in Replacement of digital type Ammeter suitable for Eleven KV breaker ranging (0-400) Amps suitable for auxilary voltage 230 volts complete including taking down old unserviceable Ammeter complete all as directed.
Supply & lay in replacement GI tubing of 40mm dia Medium grade for cable protection at hard standing/road crossing including taking out old GI tubing complete all as directed.
S & F in repairs service wire insulated PVC sheathed 2 core x 6 Sqmm aluminium conductor complete all as directed
S & F in repairs service wire insulated PVC sheathed 2 core x 4 Sqmm aluminium conductor complete all as directed.
S&F in replacement PVC Junction box of size 250x200x100mm,light weight pole mounting including MCB SP 10Amps including necessary busbar MCB mounting arrangement and necessary connector for looping in and looping out cable connection and suitable glands including taking down old unserviceable junction box complete all as directed. Make :- SINTEX or techno commercially equal in Hensil and C&S
Supply and fix in replacemen timer switch 40A, 3pole 230V, Anlog time switch type suitable for timelite distribution board including taking down old unserviceable timer switch complete all as directed. Make: Cat Ref Timeline 40 A 3 pole 230V in Indoasian or techo commercially L&T
Cutting and trimming the tree branches of any girth and of any size touching the overhead lines and clearing to a distane of 1.5 mtr length on either side of OH line with in an average span of 40 mtrs each and disposing the same and clearing the site complete all as directed.
M&L for cleaning the street light poles of any height including GI pipe for street light fitting and any description, cleaning thoroughly with cleaning agent including scrapping up of old corroded paint dirt/dust/ rust carefully and applying two coats of aluminium paint over one coat of red oxide metal primer paint before 01 Day of aluminium painting, and marking of zebra crossings up to a height of 1.5m above the coping with black and yellow strips of synthetic enamel paint including writing of pole numbers and two coats of black synthetic enamel paint on PCC coping complete all as directed. Note :- Strip size of yellow and black painting shall be as directed.
S&F in repairs Silica gel complete all as directed.
Dismantling of old unserviceable Panel and Supply & fabrication of LT Panel Board CPRI approved cubical type made of 2 mm thick sheet steel outdoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Aluminium bus bar of 600 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No, CTs of suitable ratio, and Indicating LED type lamp for Red, Yellow and Blue in incomer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations, testing and commissioning complete and consisting the following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work. (a) MCCB 4 Pole 400 Amps 35KA -01 No. (as Incoming) (b) MCCB 3 Pole 250 Amps 25KA -02 No. (as Outgoing) (c) MCCB 3 Pole 100 Amps 16KA -02 Nos. (d) MCCB 3 Pole 63 Amps 16KA -02 Nos (as Outgoing) Make for MCCB's: - L&T/Schneider/ABB/Havells
Dismantling of old unserviceable Panel and Supply & fabrication of LT Panel Board CPRI approved cubical type made of 2 mm thick sheet steel outdoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Aluminium bus bar of 600 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No, CTs of suitable ratio, and Indicating LED type lamp for Red, Yellow and Blue in incomer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations, testing and commissioning complete and consisting the following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work. (a) MCCB 4 Pole 400 Amps 35KA -01 No. (as Incoming) (b) MCCB 3 Pole 250 Amps 25KA -02 No. (as Outgoing) (c) MCCB 3 Pole 100 Amps 16KA -02 Nos. (d) MCCB 3 Pole 63 Amps 16KA -02 Nos (as Outgoing) (e) On load change over switch 4P 200Amps Make of MCCB's and COS:- L&T/Schneider/ABB/Havells
Dismantling of old unserviceable Panel and Supply & fabrication of LT Panel Board CPRI approved cubical type made of 2 mm thick sheet steel indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Aluminium bus bar of 500 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No, CTs of suitable ratio, and Indicating LED type lamp for Red, Yellow and Blue in incomer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations, testing and commissioning complete and consisting the following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work. (a) MCCB 4 Pole 400 Amps 35KA -01 No. (as Incoming) (b) MCCB 3 Pole 250 Amps 25KA -02 No. (as Outgoing) (c) MCCB 3 Pole 100 Amps 16KA -02 Nos. (d) MCCB 3 Pole 63 Amps 16KA -02 Nos (as Outgoing) Make of MCCB:- L&T/Schneider/ABB/Havells
Dismantling of old unserviceable Panel and Supply & fabrication of LT Panel Board CPRI approved cubical type made of 2 mm thick sheet steel indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Aluminium bus bar of 500 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No, CTs of suitable ratio, and Indicating LED type lamp for Red, Yellow and Blue in incomer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations, testing and commissioning complete and consisting the following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work. (a) MCCB 4 Pole 400 Amps 36KA -01 No. (as Incoming) (b) MCCB 4 Pole 160 Amps 36 KA -02 No. (as Outgoing) (c) MCCB 3 Pole 100 Amps 16KA -03 Nos. Make of MCCB:- L&T/Schneider/ABB/Havells
M&L for Cable jointing kit for HT, Eleven KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as directed.
M&L for Cable jointing kit for HT, Eleven KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 400 Sqmm complete all as directed.
M&L for cable end termination kit, heat shrinkable, outdoor type, suitable for 3 core x 120 to 185 Sqmm HT, 11 KV cable with necessary lugs including taking down jointing kit complete all as directed.
Taking down the unserviceable disc insulator and S&F new disc type porcelain insulator vitreous brown 145mm height and 255mm dia ball and socket type single disc assembly with GI clamp nuts and bolts etc suitable for 11000 V grade working pressure complete all as directed.
S & F in repairs of barrel fuse single pole 20 amps (suitable for 200 KVAR capacitor bank each of 100 KVAR capacity) complete all as directed.
S&F tinned Copper fuse wire of 30 Amp to 50 Amps capacity for replacement of fused off complete all as directed.
All as per srl item No.88 here-in-before but of Capacity 100 Amp
M&L for cement concrete 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundations, filling & mass concrete including demolition of old concrete complete all as directed.
M&L Cement concrete 1:3:6 type C2 (using 40mm graded aggregate) as in foundation, filling & mass concrete for electric pole & mass concrete type including demolition of old concrete complete all as directed.
Supply and Fixing in repairs battery cell UPST 100 for 110V or 30 V Battery Bank complete all as directed. Make :- Exide - UPST 100.
M&L for cleaning/Painting the HT poles of OH lines and six poles/four poles/two poles structure complete with cross arms any height and any description thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt/dust/rust carefully and applying two coats of aluminum paint including marking of pole numbers for the following : -
Single HT Poles
Two poles with cross Arms
Four Poles with cross Arms
Six Poles with cross Arms
S&F in repairs panel circuit board (PCB) including display unit suitable for Air cooled chiller AC plant of capacity upto 33 TR including making necessary connection, testing, complete all as directed. Make- Blue Star /Voltas
Taking down Ceiling fan/Exhaust fan/Wall mounted/Industrial fan of any type , make and sweep dismantling, cleaning greasing/ overhauling, adjustment of down rod including replacement of rubber, bolt & nuts etc including painting in two coats with existing colour and refixing in existing position with new cable wire connection complete all as directed.
M&L for rewinding of fan motor of any make/sweep of ceiling fan, exhaust fan any dia mm, including removal of existing burn't winding carefully from slots,cleaning the slots with cleaning agents,and rewinding with super enameled copper wire of same guage/type, varnishing complete all as directed .
Supply only ball bearings suitable for any type of fan/exhaust fan and testing complete all as directed . Make-NBF/NBC/TATA
Taking down unserviceable down rod of ceiling fan and replace with new down rod (Pin or Thread type) at any height, with matching painting including connected spares for mounting of fan complete all as directed .
M&L steel tubular swaged poles type 410 SP-31 (09 meter long) complete with CI base plate including errection of pole with excavation and earth work including PCC (1:4:8) type D2 for foundation base and PCC (1:3:6) type C1 for foundation and coping with PCC (1;2:4 ) and painting two coats of aluminium paint over a coat of Red oxide paint including removing of old unserviceable steel tubular pole complete all as directed by Engr-In-Charge. Note:-Crane charges for erection shall be deemed to be inclusive in quoted rate.
Removing defective fan motor from A/C and rewinding of blower motor with same gauge and turns of copper enameled wire and replacement of bearing, & refixing, testing and commissioning of 1.5 Ton window/Split type AC of any make complete all as directed.
S & F in repairs Running capacitor of 50+6 MFD for Window/Split type AC's all as directed by Engr-in-charge.
S & F in repairs Running capacitor of 36 MFD for Window/Split type AC's all as directed by Engr-in-charge.
M&L rewinding of blower motor with same guage and turns and weight of copper enameled wire and replacement of bearing, testing and commissioning of 1.5/2.0 Ton split type AC of any make, any model complete all as directed.
Taking down carefully old burnt/unserviceable compressor unit of 1.5 ton capacity window type AC of any make and model and replacing the same with Brand new Com-pressor (reciprocating /rotary) including necessary accessories and mounting materials, welding, brazing, leak testing, vaccumissing and charging the refrigerant gas to the required pressure and weight, reinstalling the AC unit on the same place including testing and commissioning complete all as directed. Make : VOLTAS/VIDEOCON/ CARRIER/ BLUESTAR/ /LG/HITACHI
Description all as per Item No.104 above but 1.5 Ton Split type AC
Servicing and overhauling the 1.5/2.0/3.0 Ton capacity (Window/Split) AC (indoor + outdoor) with water, chemical air clearner, filter and drying, checking the bolt and nut connections, filling, refixing and testing complete all as directed.
S & F in repairs evaporating coil made out of 25 SWG copper tubing having 30/34G aluminium fins per length for window /split type AC's of 1.5 Ton capacity complete all as directed
Taking out the unserviceable condensor coil and S & F new condensor coil made out of 25 SWG copper tubing having 30/34G aluminium fins per CM length for window /split type AC's of 1.5 Ton capacity .
Supply and fix in repairs copper tube of size 3/8, 5/8 inch dia includng necessary soldering , flooring and connecting and testing in between indoor to out door units of split type AC 1.5 Ton complete all as specified and directed by Engr-in-charge.
Description all as per Item No.109 above but size of copper tubing 1/2, 1/4 inch dia complete all as directed by Engr-in-charge.
S & F in repairs insulation felt for split type AC 1.5 / 2.0 Ton copper tube inlet/outlet to out door unit complete all as directed by Engr-in-charge.
Supply & charge in repairs refrigerant gas R-22 upto required level complete all as specified and directed by Engr-in-charge, Make- MAFRON/FREON
S & F in repairs indoor blower for split type AC as per existing model, sample complete all as directed by Engr-in-charge.
M&L for removing of existing 09 metre long LT Steel tubular swaged pole complete with cast iron base plate, final taper plug, bolts, nuts and screws and erecting in new location including one coat of aluminium paint for exposed surfaces and Zebra Crossing Strips from Copping (Copping Excluded) to 1.5 mtr height with Yellow and Black Strip and Copping should be painted with Black Paint, complete with excavation,earth work,PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation and coping of poles PCC 1:3:6 type C1 (using 20mm graded aggregate), including transportation from one place to another place inside Lab area, complete all as directed by Engineer-in-Charge. Note:- Rate quoted is deemed to be included excavation, earth work, foundation and coping work and painting work complete. Strip size of painting shall be directed.
Opening the compressor of Voltas Model No GSACDX RO-92-1 Air Cooled chiller Package type from its installed position by arranging dummy plates to suction and discharge lines, dismantling and removing of all internal parts, cleaning, overhauling and replacing worn out nuts, bolts, washers, springs, gaskets, shaft seal, ‘O’ rings etc., reassembling back all the internal parts, removing of dummy plates, oil charging, pressure testing, charging gas, testing and commissioning complete all as directed.. Note (A) Note:- Equipment like tripod and chain pulling block etc are required & transport this Job included in quoted rates shall be deemed to be included in unit rate. Note (B) :- Replacement of spares, Oil & Gas shall be measured and paid separately under the relevant items of this schedule.
Supply of the following items to Voltas Model No GSACDX RO-92-1 Air Cooled chiller Package (90 TR) type compressor complete all as directed by Engineer-in-charge.
Piston rings
Bearing
Oil filter
Compressor Oil
Compressor re-winding (90 TR)
MCS magnum Controller programming (PCB)
Supply and fixing and replace 36/40 Watt FTL 4 feat tube rode all as directed
Opening the compressor of Voltas up to 12 TR Air Cooled chiller Package type from its installed position by arranging dummy plates to suction and discharge lines, dismantling and removing of all internal parts (dry filters/ air filters), cleaning, overhauling and replacing worn out nuts, bolts, washers, springs, gaskets, shaft seal, ‘O’ rings etc., reassembling back all the internal parts, removing of dummy plates, oil charging, pressure testing, charging gas, testing and commissioning complete all as directed. Note (A) Replacement of spares, Oil & Gas shall be measured and paid separately under the relevant items of this schedule.
S&F including testing and commissining for scroll type compressor unit suitable up to 12 TR package type plant, compatiable to R-22/R-134a refrigerent, thermally protected, Max system test pressure low/high side: 25 bar(g)/31.9 bar (g), Maximum differential test pressure : 28 bar, 3 phase, with working voltage of 460-400V+10%, 50 Hz, full laod amp 35A, nomial flow rate : 43.4 m3h, RPM : 2900 tr/Min complete with all necessary fittings, including dismantling existing unserviceable compressor and seperate from existing refrigerant & electrical line, including brazing, leak testing, cable connections with lugs complete all as directed Make: Model CSHA150K of Trane Make or equivalent in Denfoss/Indfoss
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
SUN LIGHT HOUSE
vvcenterprises
UNITY ENGINEERING TRADERS
Bismi Engineering
Universal refrigeration and Engineering Company
M/S SRIDEVI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .