Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-AOC LANE NO 05 HNO 56 SHIV VIHAR TALAB TILLO JAMMU | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹2.7 L+₹6,890 (2.66%)Rejected-Finance NEAR SURAJ ICE FACTORY TALAB TILLO JAMMU | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹2.7 L+₹9,008 (3.47%)Rejected-Finance LANE NO 5 HNO 560 SHAM VIHAR TALAB TILLO JAMMU | L3 | Rejected-Finance Being L3 |
Tender Value
₹2.7 L
EMD Value
₹5,340
Closing Date
17 Dec 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer University works department Uni
Executive Engineer University works department University of Jammu
Electric repair to be carried out for the renovation of the rooms allotted to the office of the Dean Planning and development Adam II at New University campus
2022_UDJK_198559_1
enit 693 dated 28-11-22
Open Tender
Electrical Works
Item Rate
90 days
University of Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Executive Engineer University works department Uni
₹5,340
4 Feb 2025
5 Dec 2022
20 Dec 2022
5 Dec 2022
17 Dec 2022
5 Dec 2022
Amount
Wiring for light point/fan point/ceiling fan point/exhaust fan point/call bell point with 1.5 Sq. mm FRLS PVC insulated, copper conductor cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic, laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq mm. FRLS PVC insulated copper conductor single core cable etc. as required. Wire Make ISI Marked Havells/Anchor /HPL Conduit Make - ISI Marked Anchor/High Power /AKG Group ‘A’
Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. (Wire Make ISI Marked Havells/Anchor/HPL) 2 x 1.5 + 1 x 1.5 Sqmm
--------------------do---------------------- 2 x 2.5 + 1 x 2.5 Sqmm
--------------------do---------------------- 4 x 6 + 2 x 6 Sqmm
Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required- ISI Marked Anchor/High Power /AKG) 25 mm dia
Supplying and fixing 5 amp to 32 amps rating, 240/415 volts, 10 KA C curve miniature circuit breaker of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make Havells /Anchor/HPL) Single pole
Supplying & fixing D.P. sheet steel enclosure on the surface/ recess along with 25/32 Amp 240 volts ‘C’ curve DP MCB complete with Connection testing and commissioning etc.as reqd. (Make Havells/HPL /Anchor)
Supply and fixing of metal Box of following size on the surface/recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200mm x 125mm x 60mm deep
Supply & fixing 15/16 amp piano type switch on the existing switch box or cover including connection as required. (Make: Anchor/Havells /HPL/Sanchi major)
Supply & fixing 6 pin 15/16 amp socket outlet on the existing switch box or cover including connection as required (Make: Havells/ Anchor/Sanchi major)
Supply & fixing 5/6 amp piano type switch on the existing switch box or cover including connection as required (Make :Havells/ Anchor /Sanchi major)
Supply & fixing 3 pin 5/6 amp socket outlet on the existing switch box or cover including connection as required(Make: Havells/ Anchor /Sanchi major)
Supplying and fixing following ways and three pole and neutral, plain/horizontal sheet steel MCB Distribution Board on surface/in recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections including powder painted earthing etc. as required (But without MCB/RCCB/Isolators) Havells/Anchor /I.A /HPL) 6 way(4+18), Double Door
Supply & fixing two module stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. as required. (Make Havells/ HPL / Anchor /Sanchi Major)
Supplying and fixing brass batten/Angle holder including connection etc. as required. (Make Havells/ HPL / Anchor / Sanchi Major)
Providing and fixing following rating and breaking capacity MCCB with Thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make Anchor /Havells /HPL/I.A) 200 A, 16 KA, TPMCCB
Supplying and fixing of 63 A rating Four Pole, 415 V Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required (Make Havells /Legrand /Anchor/ C&S/L&T/ Siemen/IA/HPL/Standard)
Supply and drawing UTP 4 Pair Cat 6 LAN Cable in the existing surface/recessed steel/PVC conduit as required (Make Legrand /Havells / Anchor/D Link /HPL/L&T) 1 run of cable
Supply & fixing piano type Telephone socket outlet on the existing Switch Box or cover including connection as required. (Make Havells/HPL/Anchor)
Supplying & drawing 2 pair (0.50)sq mm FR PVC insulated annealed copper conductor un armoured telephone cables in the existing surface/recessed steel or PVC Conduit as required (Make ISI Marked Havells/Anchor/ KEI/HPL)
Supply &Installation of following type of surface mounted/recessed mounted decorative Indoor Linear energy saving , energy efficient LED Lumainiers complete with connection testing and commissioning. Make (Halonix/ Havells/Bajaj/HPL/Compact) 4 feet 18 to 22 watt ,230 volts LED batten type tube light fitting complete
-----do------- 18 To 22 Watt LED recessed/surface mounting 6500 K, 240 Volts as per cat : Slim Panel down light fittings/luminaries square or round (225x225mm) to (300x300mm) Dimensions.
Supply, testing and commissioning of PVC sheathed Aluminum conductor 1100 volts graded PVC AA Armoured/unarmoured XLPE Cable including end termination, crimping, cost of thimbles, nuts bolts, glands, connection, testing and commissioning complete job. (Make: Havells / General/Polycab / Gloster) 3 ½ core 35 sq mm armoured cable
Supply, installation, testing, commissioning of 1200 mm sweep ceiling fans complete with blades BEE 3 to 5 star rated energy efficient. (Make: Havells /Anchor/Bajaj /Compact)
Supply, installation, testing, commissioning of heavy duty 300 mm sweep BEE 3 to 5 star rated energy efficient exhaust fan. Make: ( Anchor/Havellls/Bajaj/Crompton)
P/F following rating 230 volts energy saver LED Lamps and LED Tubes 4’ long (Make :Philip /Havells/Anchor) 18 to 25 Watt LED
Providing & fixing 40 amp rating , 230 volts SPN MCB in the existing MCB DB or enclose complete with connection testing and commissing complete Job. (Havells/Anchor/HPL make)
Providing & fixing Ding Dong wall bell including connection as required (Anchor/ HPL/Klick)
Design, manufacture, testing at works & supply, installation, testing & commissioning cubicle panel floor mounted (on base frame) totally enclosed and extensible type . The general construction shall comprise to IS 8623-93. The design shall include all provisions for safety of operating and maintenance personal. IP 42 for indoor and IP54 for outdoor, shall be compartmentalized type having space and arrangements for I/C. cable/bus ducting/incoming switch gears, bus couplers, insulated and properly supported compartmentalized switch gear, outgoing compartmentalized switch gear, bus bar support and terminations, interconnection between bus bars & switch gear with auxiliary bus bars/insulated conductors/strips etc. The panel shall be fabricated out of CRCA not less than 2.00 mm thick for the load bearing members and 1.6mm for doors of L.T Panels. The frame work may be Agle Iron/Channel/Bolted type construction should be arrangement for I/C/O/G. Cable termination with 2 Each. 20x5mm cu. Strip fixed all around the panel connected to 2 Each. earth bars cu-strips connected to incoming earth conductor. (Make Electric Field/ Bharti Engineers/Gupta & Friends/ Gaytri) MAIN CONTROL PANEL a. INCOMING Space for 1 No. 200 Amp TPN Al. Bus bar of equal cross section for Main Power connection to Main MCCB. Space for 1 No. 200 Amp 4 pole MCCB of 50KA b. INDICATING PANEL The indicating panel of the incomer shall be provided with the following: i. Ammeter of required range with ASS, CT's. ii.Voltmeter of required range with VSS. c. OUTGOING Space for 1 No. 600 Amp TPN Al. Bus bar of equal cross section for power load/light load connection to the new and the existing building. Dimensions = 2’ x 1’6” x 1
Harjeet Singh
M/s Guru Nanak Electricals
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .