Garrison Engineer St Thomas Mount
Garrison Engineer, St.Thomas Mount, Old MH Complex, Rudra Road, Chennai-600 016
REPAIRS TO LOW TENSION EXTERNAL ELECTRIFICATION,DG SET AND ALLIED WORKS AT INSIDE OTA CHENNAI UNDER GE STM
2021_MES_473832_1
8247-REPAIRS TO LOW TENSION EXTERNAL ELECTRIFICA
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
St Thomas Mount
As per Tender Documents
6 documents required · 6 mandatory
₹500
Garrison Engineer, St.Thomas Mount
₹90,000
Yes
24 Nov 2021
8 Sept 2021
8 Oct 2021
8 Sept 2021
6 Oct 2021
22 Sept 2021
8 Sept 2021 - 16 Sept 2021
Amount
Excavation in trenches n.exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose soil for laying cables / GI pipe, foundation of pole, stay etc complete all as specified and as directed by Engr - in - Charge.
Removing surplus excavated soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engr - in - Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and as directed by Engr - in - Charge.
M&L for sub class 'B' brick for protection of UG cable in tranches of old size brick all as specified and directed by Engineer-in-charge.
Supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed. Note: Punned thickess i.e 18 cm shall be measured for paymeny purpose.
Taking out from trenches/poles/wall etc LT XLPE UG Cable /PVC Sheathed aluminium conductor armoured and relaying after fault rectification duly tested in trenches/Poles/Wall of LT UG Cable size of following sizes :Note: Rate including Earth Work. Jointing Kit will be measured and paid separately under relevant Item
LT UG Cable 2/ 3.5/ 4 core 6 Sqmm to 3.5 core 50 Sqmm
LT UG Cable 3.5 core 70 Sqmm to 3.5 core 300 Sqmm
Taking down old UNSV UG Cables and taking as schedule of credit including, Supplying, laying, jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed of following sizes:
LT UG Cable 3.5 core 50 sqmm .
LT UG Cable 3.5 core 70 sqmm .
LT UG Cable 3.5 core 95 sqmm .
LT UG Cable 3.5 core 120 sqmm .
LT UG Cable 3.5 core 150 sqmm .
LT UG Cable 3.5 core 185 sqmm .
LT UG Cable 3.5 core 240 sqmm .
LT UG Cable 3.5 Core 300 Sqmm
LT UG Cable 3.5 Core 400 Sqmm
Supply and Fix Straight through joints Heat Strink insulations and sealing system for underground cable including joint kits and labour complete for making joints suitable for LT XLPE/ PVC sheathed/ armoured heavy duty cables with aluminium conductor all as specified and as directed of following sizes:-
3.5/ 4 core 70 Sqmm Make: Raychem/3M or equivalent
3.5/ 4 core 95 Sqmm Make: Raychem/3M or equivalent
3.5/ 4 core 120 Sqmm Make: Raychem/3M or equivalent
3.5/ 4 core 150 Sqmm Make: Raychem/3M or equivalent
3.5/ 4 core 185 Sqmm Make: Raychem/3M or equivalent
3.5/ 4 core 240 Sqmm Make: Raychem/3M or equivalent
3.5/ 4 core 300 Sqmm Make: Raychem/3M or equivalent
3.5/ 4 core 400 Sqmm Make: Raychem/3M or equivalent
Taking down old UNSV Main switch/ Switch fuse Unit and taking as schedule of credit including Supply & Fix following MCCBs Thermal magnetic release type directly fixing to main board/panel /walls including new alteration to panel with all necessary accessories all as specified and directed. Make: ABB/Siemens/Standard/L&T
MCCB 63A , 4 pole , 16 KA
MCCB 100A , 4 pole , 16 KA
MCCB 125A , 4 pole , 16 KA
MCCB 160A , 4 pole , 35 KA
MCCB 200A , 4 pole , 35KA
MCCB 250A , 4 pole , 35 KA
M & L inreplacement for factory made sheet metal encloser (junction panel) made out of 14 SWG CRCA sheet powder coated weather proof out door type with 60cm long legs 4 Nos made out of 40X40X6mm equal angle size of encloser not less than 75X60X30cm depth with front and rear openable double door with locking arrangement including 4 strip aluminium bus bar of rating 600 Amps suitable for one incoming and 5 out going feeders, mounted on insulators including disconnection of cable from the burnt bus bar and connection in the new chamber with bolts and nuts, including thimbles of suitable sizes, neccessary earth work and PCC foundation for grouting of four legs all as per existing Make: Standard/L&T/Havells
Supply only aluminium tube terminals (cable lugs) of size 70 Sqmm Make- Dowells/Eqvt
Supply only aluminium tube terminals(cable lugs) of size 95 Sqmm Make- Dowells/Eqvt
Supply only aluminium tube terminals (cable lugs) of size 120 Sqmm Make- Dowells/Eqvt
Supply only aluminium tube terminals (cable lugs) of size 150 Sqmm Make- Dowells/Eqvt
Supply only aluminium tube terminals (cable lugs) of size 185 Sqmm Make- Dowells/Eqvt
Supply only aluminium tube terminals (cable lugs) of size 240 Sqmm Make- Dowells/Eqvt
Supply only aluminium tube terminals (cable lugs) of size 300 Sqmm Make- Dowells/Eqvt
Supply only aluminium tube terminals (cable lugs) of size 400 Sqmm Make- Dowells/Eqvt
Complete servicing, overhauling, repairing, cleaning, oiling with setting of tripping mechanism of following Air Circuit Breaker(ACB) 415 volts of capacity 630 amps to 1000 Amps 50Hz any type or make or all as per existing including submission of service & test reports. The servicing to be done by authorised service provider of manufacturer. The details are placed at "Scope of work" as given under.Note :Minimum spares/lubricants and tools required for the job should be included in the coated rates .
SCOPE OF WORK all as per item No.19 (i) Moving arcing contacts shall be checked. Cleaning of breaker with CRC-226 (ii) Removal of old grease and re-greasing the same with recommended grease. (iii) Check condition of arcing contact and gap between fixed and (iv) Checking the reset mechanism, tripping of breaker through push button (v) Checking tripping of ACB through protection release (vi) Tripping of ACB manually through volt metric release. (vii) Checking and adjust freeness of DN and volt metric release trip rod (viii) Checking presence and proper tightening of hardware. (ix) Checking presence of all circlips (x) Checking condition and alignment of jaw contact with cradle terminals (xi) Checking condition of ACB wiring and replace if required (xii) Checking and adjusting gap between hylam sheet and side plate (xiii) Checking proper closing of all poles together (xiv) Checking working of anti pumping device. (xv) Checking alignment of SIC and it’s operation (xvi) Checking scrapping earth alignment (xvii) Checking condition of arc chutes (xviii) Checking U/V release pick up and drop off (xix) Checking ACB tripping through shunt release (xx) Checking continuity and proper changeover of aux contact block (xxi) Checking of release by secondary injection for O/L, S/C, E/F (xxii) Setting of release as per the load (xxiii) Checking the healthiness of CTs
Supply and fixing by replacement of following items of Air Circuit Breaker (ACB) 415 volts 630 to 1000 Amps 50Hz,any type or make or all as per existing
Closing Relay
Terminal Adaptors (4 terminals per Phase)
Relay Module
Shunt trip Release
Auxiliary Switch
Arc Chutes
Trip Push Buttons
ACB Position Indicator
Checking of APFC panels/capacitors bank panels, servicing of the same, cleaning of the switch gears, busbars with CTC to remove the carbon deposits, checking the connections, functioning of the components such as capacitors, contactors, switch gears etc., disconnecting and removing of burnt out cable end portions, crimping with new suitable lugs, removing of burnt out thyristors reconnecting back and testing complete for maintaining efficient power factor at the sub station all as directed. Note: Inspection of APFC panel shall be carried by the representative of OEMs of L&T/Neptune/Epcos only.
Dismantling unserviceable power factor improvement capacitor of various capacities and Supply and fix heavy duty Cylindrical capacitors AC 440 volts, 50 Hz, Delta connection new power factor improvement capacitor of following capacities complete all as specified and directed. Make : havells, ABB ,Epcos or equivalent
25 KVAR Capacity
20 KVAR Capacity
15 KVAR Capacity
10 KVAR Capacity
5 KVAR Capacity
Supply and in replacement of MCB Four pole 40 to 63 Amps 10 KA C curve series ISI marked including necessary connections compete all as specified and as directed. Make : L&T / Siemens / ABB
Supply and in replacement Contactor suitable for 25 KVAR 415 Volt, 3 phase including necessary connections compete all as specified and as directed. Make : L&T / Siemens / ABB
Supply and in replacement Contactor suitable for 15 KVAR 415 Volt, 3 phase including necessary connections compete all as specified and as directed. Make : L&T / Siemens / ABB
Supply in replacement Contactor suitable for 5 to 10 KVAR 415 Volt, 3 phase including necessary connections compete all as specified and as directed. Make : L&T / Siemens / ABB
S&F, power factor control relay (APFC) 12 step including necessary electric connections and testing including dismantling unserviceable power factor control relay from the panel boards, complete all as specified and directed. Make: L&T/Neptune/EPCOS
Supply and fix inreplacement of 230 Volt Control relay ,all as directed. Make : L&T / Siemens / ABB
Supply and fix inreplacement of LED type three phase Voltmeter ,all as directed.
Supply and fix inreplacement of LED type three phase Amper meter with CTs ,all as directed.
Supply and fix inreplacement of MCB, SP, 6 Amps, having breaking capacity 10 kA, dual termination, isolation function with visual indication complete all as specified.
Supply and fix inreplacement of push buttons with 1 NO / 1 NC, screw type for operation of capacitors all as per sample available at sub stations including necessary electric connections and testing including dismantling unserviceable push buttons (start/stop button) from the power factor capacitor panel boards complete all as specified and directed.
Supply and fix in repairs, LED indicating lamps of red/yellow/ blue/green /amber with bulbs including connection and testing complete all as specified and directed. Make : AEI/IMP/MECO/L&T/SIEMENS/C&S
Supply only first-aid box with suitable medicine (As per medical norms).
Dismantling unserviceable/ burnt electric wiring from the power factor capacitor panel boards, cleaning the panel with CTC to remove the carbon deposits, rewiring of control circuit of the panel boards with suitable size of PVC insulated, sheathed, stranded copper cable of suitable size, including provision of suitable copper lugs, bolts, nuts, washers etc., complete including electric connections and testing complete all as specified and directed.
S&F in repairs, medium duty copper lugs suitable for 35 Sqmm size cable complete all as directed. Make:DOWELLS/JOHNSON/COMET
S&F Reflector adhishive tape 25 mm with suitable for fixing in street light pole, colour of paint as decided by Engr in charge.
Supply and spread stone metal graded aggregate of size 40 mm in transformer yard at various locations complete all as directed by Engr-in-Charge.
M&L for Broken stone or Boulders hardcore of gauge not exc. 63mm, deposited, spread and levelled in layer not exc. 150mm thick, watered and rammed to a true surface, complete all as spacified and directed.
S&F of tubes light grade of size 80 mm dia galvanised with all fittings and fixed complete to walls and ceiling or laid in treanches, fixed on pole /under road crossing or passing through gutters etc including necessary road cutting and making good with PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) complete, including taking down old u/s GI tubing all as specified and as directed. Make : TATA/JINDAL/Prakash Surya
S&F of tubes light grade of size 50 mm dia galvanised with all fittings and fixed complete to walls and ceiling or laid in treanches, fixed on pole /under road crossing or passing through gutters etc including necessary road cutting and making good with PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) complete, including taking down old u/s GI tubing all as specified and as directed. Make : TATA/JINDAL/Prakash Surya
S&F of tubes light grade of size 40 mm dia galvanised with all fittings and fixed complete to walls and ceiling or laid in treanches, fixed on pole /under road crossing or passing through gutters etc including necessary road cutting and making good with PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) complete, including taking down old u/s GI tubing all as specified and as directed. Make : TATA/JINDAL/Prakash Surya
Supply and laying inreplacement of 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed twin core 4 sq. mm nominal cross section in service connections incl necessary connection etc complete all as specified and directed.
Supply and laying inreplacement of 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed twin core 6 sq. mm nominal cross section in service connections etc complete all as specified and directed.
Supply and fixing in replacement Danger notice plate of 1.6 mm thick mild stell sheet, vitreous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with MS clamps , bolts and nuts of approved size for LT 20x15 cm size all as specified and directed. Note :- Instruction shall be written in three lauguage Hindi, English and Tamil on notice board.
Supply only Synthetic insulating mat of size 2Mx1Mx10mm thick ISI marked complete as sepecified and directed by Engr-in-Charge.
Supply and fix /erect/ ground LT cable route indicator made out of GI plate 3 mm thick and 6 inches dia duly marked with working voltage, size of cable and route indicator fixed with angle iron of size 25 x25 x3 mm thick, 50 cm long embedded in PCC 1:2:4 type B1 of size 30 x 30 x 30 cm in ground all as specified and as directed
M&L for load balancing of Single/three phase system at LT Panel upto Distribution box of any size and capacity complete including disconnecting of existing cables and refixing the same as per load balance requirement including replacement of burnt/carbonized aluminium tube terminal of any size and capacity all as specified and as directed by Engr-in-charge. Note : (i) Necessary eqpt and safety mesures reqd for load balancing arranged by the contractor without any extra cost. (ii) Cost of New aluminium tube terminal of any size as per site reqmt change under the job deemed to be included in the quoted rate
M&L for surface dressing and proper laying of XLPE electrical cable of any size and capacity nearby the LT Panel after disconnecting all incoming and outgoing connection complete , necessary earthwork as required all as specified and as directed by Engr-in-charge. (Note : Rate of necessary earthwork as required at site are deemed to be included in the quoted rate)
M&L for road cutting for laying of cable/pipe and making good the disturbed/excavated surface as per existing road including refilling the excavated material, compacting, WBM and black top carpeting with bitumen & aggregate following the stone/sand on top complete all as specified by Engr-in-Charge.
M&L for painting to two pole structure after removing /scraping/ bruses/ cleaning to old paint on external surface in one coat of paint primer by using synthetic enamel aluminium paint on steel tubular and cement on PCC pole structure in any height/ length/ dia etc ,including cross arms/ angles, nut, bolt , washers etc marking as direction using diffrent colour of paint complete for bothincoming and Outgoing all as per site requirement and directed by Engr-in-Charge. Note : Colour of paint shall be approved by Engr-in-charge.
M&L for painting to Four pole structure after removing /scraping/ bruses/ cleaning to old paint on external surface in one coat of paint primer by using synthetic enamel aluminium paint on steel tubular and cement on PCC pole structure in any height/ length/ dia etc ,including cross arms/ angles, nut, bolt , washers etc marking as direction using diffrent colour of paint complete for bothincoming and Outgoing all as per site requirement and directed by Engr-in-Charge. Note : Colour of paint shall be approved by Engr-in-charge.
Supply and fix in replacement of Air termination, single pointed copper rod 12 mm dia and 300 mm along with saddles and screws including taking down old complete all as specified and as directed.
Supply and fix in replacement of Aluminium strip 25 x 3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground level including taking down old complete all as specified and as directed.
Supply and fix in replacement of Test point terminal block made of gun metal or phosphorus bronze size 75x75 x25 mm drilled and screwed along with saddles incuding 3 Nos 8 mm dia 25 mm long hex head screw complete all as specified and as directed
Supply Fabricate, install, connect, test and commission CPRI Approved LT electrical Feeder Piller panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, IP 65 outdoor weather proof type, fabricated with 3.00 mm thick mild steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates,front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars of suitable capacity as per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including painting of panel board with two coats of synthetic enamel paint over one coat of red oxide primer and Existing cable of any size / type to be connected with proper termination complete all as specified and comprising of the followings:-
INCOMING :- (i) ON LOAD Change over Switch 320 Amps - 01 No OUTGOING :- (i) MCCB 4 Pole, 415 V, Thermal Magnetic type, 200 Amps with breaking capacity 16 KA. - 03 Nos (ii) Multi function Meter with CT & PTs-01 No (iii) Phase indication lamps - 3 Nos. Note: All Changeover Switch/MCCBs should be front handle operated.
M&L for prepartion of old painted surfaces of LT panel/feeder piller box of any type outdoor/indoor including removing old paint with scrubing and applying one coat of synthetic emanel paint of shade as per existing over a coat of red oxide primer,with electrically operated spray machine , complete all as specified and directed.
Material and labour for earth pit chamber of size 0.6mx0.6mx0.6m made with PCC 1:2:4 type B-2 including HDPE earthing pit cover inspection chember of size 200 mm depth, 300mm length and 300mm width, complete all as specified and as directed.
Material & Labour for Earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to steel strip 25X4 mm dia by means of bolts, nuts, washers and check nuts made out of galvanised iron, protected by GI pipe light grade 15 mm bore dia and connected to main control board all as shown in Electrical plate No 5 of MES SSR Part I including necessary excavation and earth work in any type of soil, salt, charcoad dust, PCC 1:2:4 type B1 in chamber, RCC 1:2:4 chamber cover with 6 mm dia MS bar at 100 mm centre to centre both ways and MS 6 mm dia hook complete all as specified and directed.
M & L for Earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to earth wire 4 mm dia by means of bolts, nuts, washers and check nuts made out of galvanised iron, protected by GI pipe light grade 15 mm bore dia and connected to main control board all as shown in Electrical plate No 5 of MES SSR Part I including necessary excavation and earth work in any type of soil, salt, charcoal dust, PCC 1:2:4 type B1 in chamber, RCC 1:2:4 chamber cover with 6 mm dia MS bar at 100 mm centre to centre both ways and MS 6 mm dia hook complete all as specified and directed.
Finding and rectification of electrical fault by Checking of external/internal elect supply feeder, street light feeder,OH conductors /under ground cables using elect tools, equipments and safty devices after arranging elect shut down of feeders from sub station to remove elect faults like tightning of loose connection,removing of any electric short,meggring of cable,excavation of soil for removing of faulty cable on a particular span and relaying of cables after removing of fault, re-tightning of cable lugs etc all as required at site and as directed by Engr in Charge. Note:- (i) The electrician employed for the purpose will be highly skilled along with one mate and should have all necessary tools and saftey devices. (ii) Any major materials used for rectification of faults like Cables,MCB/MCCB/cable jointing kits/cables of any type etc will be measured and paid seperately or supplied by department.
EVEREST ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .