| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹13.6 L+₹18,370 (1.37%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L2 | Rejected-Finance 2ND LOWEST BIDDER | |
| 3 | L3₹15.2 L+₹1.7 L (12.8%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L3 | Rejected-Finance 3RD LOWEST BIDDER | |
| 4 | Rejected-Technical A 8 SAKHARAM GANESH DAUSKAR SARANI KOLKATA 700 025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | - | Rejected-Technical Insufficient documents. |
Tender Value
Refer Docs
EMD Value
₹30,415
Closing Date
27 Jul 2024, 4:00 pmClosed
OFFICE OF THE SUPERINTENDING ENGINEER,SWEC,PWD
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.D) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
Repair /Replacement of the Air Conditioning System in the Prenatal Intensive Care Unit at Matrima Building, Midnapore Medical College and Hospital, Paschim Medinipur.
2024_WBPWD_711931_1
WBPWD/SE/SWEC/NIQ19/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
20 days
PASCHIM MEDINIPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹30,415
OFFICE OF THE SUPERINTENDING ENGINEER,SWEC,PWD
17 Sept 2025
11 Jul 2024
25 Nov 2025
11 Jul 2024
27 Jul 2024
16 Jul 2024
15 Jul 2024
Amount
Supply,Insallation Testing and Commisioning of Microprocessor based air cooled ceiling suspended Ducted Split AC machines having following specification. a) Nominal Cooling Capacity : Minimum 21 TR or 22TR /25000 BTU or 264000 BTU/Hr / 66503 KCal 66528 KCal per Hr or Higher Capacity. b) Nominal Air Flow : 8800 CFM or Higher c) Operating Ambient Temperature : 45⁰C-50⁰C d) Refrigerant : R410A e) Controller : Intelligent Microprocessor based with LCD Display, capable of Fault display, Auto restart after power failure, Single-phasing and phase reversal protection, having Provision for fire alarm input etc standard feature. f) Compressor : Hermetically Sealed Scroll compressor 02 (two) nos at ODU. g) Power Supply : For IDU - 380-420 V , 3 Ph, 50 Hz AC or 230V AC Single phase 2 Wire AC Supply & for 02 nos ODU 415V, Three Phase, 50 Hz, AC Supply The system should give non-stop cooling at 48-52 degrees of outside ambient temperature and provide test certificate. (Make: Blue Star (Set Model : DSA2642R3)/Voltas (Set Model:- ACADS21023) / Carrier)
Supply, Installation & commissioning of suitable size 16SWG hard/soft drwan refrigeration copper pipe (Make-Ryoku/Rajco/Nippon), with 9 mm nitrile rubber tube Insulation on following sizes of suction line & Liquid Line copper pipe with proper insulation tape.(Make-Accoflex/ Armacell/K-Flex,) complete with fittings, elbows, bends, supporting arrangement on walls.
Drain Water piping work out of PVC / HDPE hared pipes with Insulation, fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors. (make-- Finolex/ Supreme) a) 32mm.Dia
Supply and fixing of double canvas connection between IDU and existing duct as per direction of the E.I.C.
S & D of 4 core 50 sqmm. 1.1KV grade XLPE insulated Al/A cable. (Make- Polycab/ Havells/ Gloster/ RR Kabel) Incoming Cable for air conditioner.
S & laying of 4 core 2.5 sqmm. 1.1Kv grade XLPE insulated Al/A cable. (Make- Polycab/ Havells/ Gloster/ RR Kabel/KEI) For communication between ODU and IDU.
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.
a) Up to 50 sqmm
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting.
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. A) 125A (Make:- Legrand/ABB/L&T)
Supplying and fixing MCCB Weather proof enclosure with IP-65 protection, pwder coated provision for housing Four pole (4P) MCCB, concealed in wall after cutting the wall & mending good the damages to original finish / on flat iron frame incl. painting, connection & provision for earthing attachment.(Make: Syntax or As per choice of EIC)
Dismantalling existing IDU/OUD, refrigeramt lines, Indoor unit and carring to suitable places of hospital campus as per direction of the EIC. [After one dismantalled and installation of new one, another unit will be allowed for dismantalling] (Existing 18 TR ductable split)
Charges for dismantalling of false ceiling for AC IDU installation, Temporary block of rest part of false ceiling by APC board for functioning of other machines IDU, refixing of dismalted false ceiling after work as per direction of the EIC
SKY DECORATIONS PRIVATE LIMITED
Lyric International
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .