| 1.00 | Repairs to 250kVA, oil immersed, manually operated, 3-phase voltage stabilizer by way of :
A. Preliminary Work:-
1. Disconnecting of all electrical connections of voltage stabilizer.
2. Opening and removal of the top lid of the stabilizer to enable retrieval of the voltage regulator and core assembly.
3. Carefully dismantling internal components of the voltage stabilizer as required.
B. Temporary Gantry Arrangement:-
1. Arranging and fabricating a temporary gantry to retrieve the voltage regulator and core assembly of the stabilizer which includes:-
i. Manual dragging of 150mm dia MS pipe from the premises of WSS Zazna 1st into the pump house.
ii. Drilling/making two holes of 200mm dia on the top opposite sides of the pump house wall for accommodation and fixing of the 150mm dia MS pipe.
iii. Fixing the 150mm dia pipe to act as a gantry beam for lifting heavy machinery.
(Note: - The 150mm dia pipe MS pipe will be provided by the department and is available at site.)
2. Fitting of the 150mm dia MS pipe into the already drilled holes at the top of the walls of pump house manually and closing the holes with cement and sand mix, complete in all respects.
3. Fixing of the available 2 ton capacity CP Block on the 150mm dia MS pipe, which shall act as gantry for lifting purpose.
C. Dismantling and Fault Rectification:-
1. Dismantling of the voltage regulator and core assembly from the voltage stabilizer.
2. Inspection and diagnosis of faults, if any in the core assembly.
D. Replacement and Re-installation:-
1. Replacement of damaged 250 amp, 3-phase, single plate voltage regulator assembly by new voltage regulator assembly.
2. Re-installation of the voltage regulator and core assembly back into the 250Kva voltage stabilizer.
3. Testing of the stabilizer on full load
Note:- Old scrap to be retained at site | 1 | Complete Job | 17,990 ₹17,990 Lowest | 19,500 ₹19,500 |
Tender Value
₹18,000
Closing Date
14 Jan 2026, 11:30 amClosed
Executive Engineer JS PHE Mech. Rural Div. Sgr.
Executive Engineer JS PHE Mech. Rural Div. Sgr.
Repairs to 250KVA oil immersed, manually operated, 3-phase voltage stabilizer at Water Supply Scheme Zazna 1st.
2026_PHE_300144_1
PHE/MRD/TS 60 OF 01/2026
Open Tender
Miscellaneous Works
Item Rate
5 days
Srinagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹50
Executive Engineer JS PHE Mech. Rural Div. Sgr.
10 Feb 2026
8 Jan 2026
14 Jan 2026
8 Jan 2026
14 Jan 2026
8 Jan 2026
Repairs to 250kVA, oil immersed, manually operated, 3-phase voltage stabilizer by way of : A. Preliminary Work:- 1. Disconnecting of all electrical connections of voltage stabilizer. 2. Opening and removal of the top lid of the stabilizer to enable retrieval of the voltage regulator and core assembly. 3. Carefully dismantling internal components of the voltage stabilizer as required. B. Temporary Gantry Arrangement:- 1. Arranging and fabricating a temporary gantry to retrieve the voltage regulator and core assembly of the stabilizer which includes:- i. Manual dragging of 150mm dia MS pipe from the premises of WSS Zazna 1st into the pump house. ii. Drilling/making two holes of 200mm dia on the top opposite sides of the pump house wall for accommodation and fixing of the 150mm dia MS pipe. iii. Fixing the 150mm dia pipe to act as a gantry beam for lifting heavy machinery. (Note: - The 150mm dia pipe MS pipe will be provided by the department and is available at site.) 2. Fitting of the 150mm dia MS pipe into the already drilled holes at the top of the walls of pump house manually and closing the holes with cement and sand mix, complete in all respects. 3. Fixing of the available 2 ton capacity CP Block on the 150mm dia MS pipe, which shall act as gantry for lifting purpose. C. Dismantling and Fault Rectification:- 1. Dismantling of the voltage regulator and core assembly from the voltage stabilizer. 2. Inspection and diagnosis of faults, if any in the core assembly. D. Replacement and Re-installation:- 1. Replacement of damaged 250 amp, 3-phase, single plate voltage regulator assembly by new voltage regulator assembly. 2. Re-installation of the voltage regulator and core assembly back into the 250Kva voltage stabilizer. 3. Testing of the stabilizer on full load Note:- Old scrap to be retained at site
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
BOQ_973769.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .