Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 CrAccepted-AOC | ₹13.6 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹13.9 CrRejected-Finance | ₹13.9 Cr | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹14.8 CrRejected-Finance | ₹14.8 Cr | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹15.5 CrRejected-Finance | ₹15.5 Cr | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹15.9 CrRejected-Finance | ₹15.9 Cr | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹14.8 Cr
EMD Value
₹10.6 L
Closing Date
19 Jun 2023, 6:00 pmClosed
CE Bathinda Zone
HQ Chief Engineer Bathinda Zone Bathinda Mil Stn - 151004
PROVN OF OTM ACCN (PHASE-I) UNDER GE SRI GANGANAGAR
2023_MES_588203_1
CE BTZ/SGNR/TOKEN-01 OF 2023-24
Open Tender
Civil Works
730 days
SRI GANGANAGAR
As per NIT
9 documents required · 9 mandatory
₹3,000
GE SRI GANGANAGAR
₹10.6 L
Yes
13 Jul 2023
5 Apr 2023
21 Jun 2023
5 Apr 2023
19 Jun 2023
5 Jun 2023
Amount
Lump sum price worked out by the tenderer for “BUILDING /STRUCTURE WORKS" as listed in Schedule ‘A’ Section - I
Lump sum price worked out by the tenderer for “INTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Section - II (Part-I)
Sch 'A' Sec - II (Part-II), (INTERNAL ELECTRIFICATION WORKS)
Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green etc colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ/Sch 'A').
All as per above Srl item No. 04 but for one socket out let 5 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ/Sch A).
All as per above Srl item No. 04 but for one socket out let 5 Amps point controlled by one switch (on independent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ/Sch A).
Material and labour for concealed Point wiring for one light point controlled by two Nos- two way switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket, including provn of 4 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ).
Supply and fixing switch piano flush type (ISI marked), 5/6Amps, single pole, two way, fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. Note :- Cost of laminated sheet cover for mounting of switch is included under respective item of BOQ (point wiring)
Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 11 but for one socket out let 5 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ/Sch A).
All as per above Srl item No. 11 but for one socket out let 5 Amps point controlled by one switch (on independent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ/Sch A).
Material and labour for concealed Point wiring for one light point controlled by two Nos- two way switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switch, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 25mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ).
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, minimum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50Hz, 900RPM, size 300mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement in wall and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50 Hz, 900RPM, size 450mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement in wall and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure (AC Box) with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge.
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 250 Amp rated bus bar) VTPN, 4 Way 415V, suitable for mounting MCCB/MCB, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCCB/MCB shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) TPN, 4 Way 415V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 12 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 4 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 2 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing MCCB of capacity 100 Amp, FP, 415 volt, short circuit breaking capacity 16KA , fixed thermal magnetic trip, setting 80-100%, Icu-100% Ics confirming to IEC-947, IS-13947, including thimbles, nuts, bolts, washers etc, including making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge .
Supply and fixing MCB ‘B’ curve suitable for 415 volts AC supply, 63 Amps, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘B’ curve suitable for 415 volts AC supply, 40 Amps, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 63 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 40 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 32 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 20 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 40 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing blanking plate suitable for any type of DB complete all as specified and as directed by Engineer-in-charge.
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 10 Sqmm single core (05 run i.e 4 runs for main 3 phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Five runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 6 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 4 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
Supply and fixing LED lamp minimum 3 star rated 9W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) CRI : More than 70
Supply and fixing LED complete fitting batten and rod, T-8 Retro LED tube polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear LED lighting fixture with CRCA housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, including taking down old unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with coloured plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED light fitting 1 x 10 Watt, appx 2 feet long with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, including taking down old Unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED Bulkhead fitting 1 x 10 Watt, complete with Standard LED lighting fixture with extruded polycarbonate housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : <15%. (f) IP rating : IP-65. (g) CCT : Minimum 5400K (h) Polycarbonate housing white coloured (j) LED Driver of the same make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection minimum 2.5 kV. (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing energy efficient LED security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 2 core flexible copper conductor cable 1Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Material and labour for concealed wiring for TV antenna connection complete with coaxial RG-6 heavy duty PVC insulated sheathed cable with copper conductor having single strand of 0.7 mm dia and a aluminium wire net drawn through and including PVC conduit 25mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (TV antenna connection socket outlet, terminal box shall be measured and paid separately under appropriate item of BOQ).
Material and labour for Pressed steel powder coated sunken terminal box of size 100mm x100mmx50mm concealed in wall, including inner and outer plates (cover plate) suitable for fixing and including modular type (1 module) 2 pin TV antenna connection socket outlet round flush type duly marked with symbol of TV and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed.
Material and labour for concealed wiring for telephone connection complete with PVC insulated sheathed cable with copper conductor having single strand of 0.4 mm dia two pair taped for telephone wiring drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (Telephone connection socket outlet and terminal box shall be measured and paid separately under appropriate item of BOQ).
Material and labour for Pressed steel powder coated sunken terminal box of size 100mm x100mmx50mm concealed in wall, including inner and outer plates (cover plate) suitable for fixing and including modular type (1 module) telephone connection socket outlet flush type duly marked with symbol of telephone and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed.
Material and labour for concealed Flame proof Point wiring (using red, black and green colour wires as colour coding for single phase circuits) complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) for main point and for continues as earth wire connected to earth dolly etc. (Phase, netural and earth wire) drawn through and including ERW rigid conduit stove enamelled conduit with all flame proof fittings and all accessories (duly tested by CMRI) i.e. pipe bend, union socket, reducer, elbow, pipe hook, connectors etc , for light/fan points including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. Note :- (i) One light point circuit of 02 lights controled by one MCB (ii) MCB and DB shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Flame proof Point wiring (using red, black and green colour wires as colour coding for single phase circuits) complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) for main point and for continues as earth wire connected to earth dolly etc. (Phase, netural and earth wire) drawn through and including ERW rigid conduit stove enamelled conduit with all flame proof fittings and all accessories (duly tested by CMRI) i.e. pipe bend, union socket, reducer, elbow, pipe hook, connectors etc , for light/fan points including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. Note :- (i) One light point circuit of 03 lights controled by one MCB (ii) MCB and DB shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Flame proof Point wiring (using red, black and green colour wires as colour coding for single phase circuits) complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) for main point and for continues as earth wire connected to earth dolly etc. (Phase, netural and earth wire) drawn through and including ERW rigid conduit stove enamelled conduit with all flame proof fittings and all accessories (duly tested by CMRI) i.e. pipe bend, union socket, reducer, elbow, pipe hook, connectors etc , for light/fan points including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. Note :- (i) One light point circuit of 04 lights controled by one MCB (ii) MCB and DB shall be measured and paid separately under appropriate item of BOQ).
Supply and fixing CMRI certified flameproof/weather proof 1x20 Watt LED tube light fitting, well glass luminaire suitable for RF LED lamp, recommended for Gas/Vapour group of IIA & IIB and zone 1 & 2, IP65 protection, Epoxy finish LM6 die cast aluminium housing with heat resistant toughened glass, including inbuilt electronic driver, 2 kv surge protection, internally pre-wired, LED lamp, connector block etc complete with all other accessories and including making electric connection connecting with 2 x 1.5 Sqmm single core FRLSH copper conductor cable and connector block and making good disturbed surfaces of walls/ceiling etc. complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Flameproof flexible metalic hose conduit pipe of size 20mm x 300mm long, heavy duty complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing flame proof weather proof DB SPN 240 Volts 4 way with bus bar in cast aluminium LM-6 encloser operated externally spring type knob complete with M-25 cable entry to suit incomming cable and 2 Nos M-20 cable entries for out going cable cable from bottom with cable glands suitable for hazardous area and confirming to IS-2147/62 neoprene gasket degree of protection IP-65 including flame proof MCB as under complete all as specified and as directed. (a) MCB single pole & neutral 16 Amps, 10 KA rupturing capacity, curve 'B' - 01 No (Incoming) (b) MCB single pole 2.5 Amps, 10 KA, curve 'B'- 02 Nos (Outgoing)
Supply and fixing flame proof weather proof DB SPN 240 Volts 6 way with bus bar in cast aluminium LM-6 encloser operated externally spring type knob complete with M-25 cable entry to suit incomming cable and 2 Nos M-20 cable entries for out going cable cable from bottom with cable glands suitable for hazardous area and confirming to IS-2147/62 neoprene gasket degree of protection IP-65 including flame proof MCB as under complete all as specified and as directed. (a) MCB single pole & neutral 16 Amps, 10 KA rupturing capacity, curve 'B' - 01 No (Incoming) (b) MCB single pole 2.5 Amps, 10 KA, curve 'B'- 04 Nos (Outgoing)
Supply and fixing flame proof weather proof DB SPN 240 Volts 8 way with bus bar in cast aluminium LM-6 encloser operated externally spring type knob complete with M-25 cable entry to suit incomming cable and 2 Nos M-20 cable entries for out going cable cable from bottom with cable glands suitable for hazardous area and confirming to IS-2147/62 neoprene gasket degree of protection IP-65 including flame proof MCB as under complete all as specified and as directed. (a) MCB single pole & neutral 20 Amps, 10 KA rupturing capacity, curve 'B' - 01 No (Incoming) (b) MCB single pole 2.5 Amps, 10 KA, curve 'B'- 06 Nos (Outgoing)
Subtotal
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - III (Part-I)
Sch 'A' Sec - III (Part-II), (INTERNAL WATER SUPPLY WORKS)
Supply and fixing hand shower (health faucet) fancy type, CP including 1.2 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by Engineer-in-charge.
Supply & fixing CP connection 15 mm size with CP nuts of length 450 mm and fixed complete all as specified and as directed by Engineer-in-charge.
Subtotal
Lump sum price worked out by the tenderer for “ROAD, PATH & CULVERT WORK" as listed in Schedule ‘A’ Section -IV (Part-I)
Sch 'A' Sec - IV (Part-II), (ROAD, PATH & CULVERT WORK)
Material and labour for 150mm thick WMM in two layers (75mm thick each layer) (compacted thickness) Wet mix macadam manufactured in WMM plant., with crushed stone aggregates specified grading, spreading using sensor paver and consolidated to reqd gradient and camber complete all as specified and directed.
Supply and laying/fixing 80 mm thick (M-40 grade) precast interlocking tile/paving block factory casted (made by using PVC/ Rubber moulds on Vibrating Table Machine) using grey cement and no pigment, any shape haxagon / trigular / zigzag / I-shaped etc, as directed, confirming to relevant IS, laid over and including 25mm thick layer of sand cushining and filling the interstices etc with sand complete all as specified and as directed.
Supply and laying factory made kerb stone of M-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed.
Material and labour for Thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “AREA DRAINAGE ENVIRONMENTAL POND WORK)" as listed in Schedule ‘A’ Section -V (Part-I)
Sch 'A' Sec - V (Part-II), (AREA DRAINAGE ENVIRONMENTAL POND WORK)
Material and labour for Pre-cast factory made RCC drain of size and shape as directed by GE alongwith male and female ends for proper joining, made of 75mm thick RCC M-30 using 20mm graded aggregate, duly embeded two Nos socket for hoisting including form work etc, hosting and placing at site and jointed in CM (1:4) to form uniform length and fair finish to drain upto 80cm girth (width measured @ Avg of inner and outer girth) complete all as specified and as directed by Engineer-in-Charge. Note : Reinforcement shall be measured and paid separately under appropriate item of this Sch.
Supply and laying Loose filling with stone aggregates of gauge 20 mm in recharge pit complete all as specified and as directed by Engineer-in-Charge
Supply and laying Loose filling with stone aggregates of gauge 40 mm in recharge pit complete all as specified and as directed by Engineer-in-Charge
Supply and laying Loose filling with stone aggregates of gauge 80 mm in recharge pit complete all as specified and as directed by Engineer-in-Charge
Supply and filling the coarse sand interstices in aggregate and as directed in recharge pit complete all as specified and as directed by Engineer-in-Charge
Subtotal
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORK" as listed in Schedule ‘A’ Section - VI (Part-I)
Sch 'A' Sec - VI (Part-II), (SEWAGE DISPOSAL WORK)
Supply and laying DWCPE (SN8) drain pipes 150mm nominal dia as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thhick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under appropriate item of BOQ/Sch A.
Supply and laying DWCPE (SN8) drain pipes 200mm nominal dia as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thhick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under appropriate item of BOQ/Sch A.
Supply and fixing LLDPE septic tank of capacity 5 users (minimum 2000 ltr) designed to carry sewage and sludge water, including excavation and earth work in any type of soil, installed over and including 100mm thick PCC (1:4:8) type D-2 including all necessary fittings for connecting to inlet and out let, complete all as specified and as directed.
Supply and fixing LLDPE septic tank of capacity 20 users (minimum 8000 ltr) designed to carry sewage and sludge water, including excavation and earth work in any type of soil, installed over and including 100mm thick PCC (1:4:8) type D-2 including all necessary fittings for connecting to inlet and out let, complete all as specified and as directed.
Soakage well of size 1.20 m dia and 3.00 m effective depth, excavation in any type of soil, foundation in PCC 1:3:6, walls of random rubble dry and coursed stone block masonry with top ring of M25 concrete including RCC cover slab in M25, inlet pipes of RCC/DWC, complete filled with brick bats, complete all as shown on drawing, specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “SECURITY FENCING, COMPOUND WALL AND GATE WORKS" as listed in Schedule ‘A’ Section - VII
Lump sum price worked out by the tenderer for “ EXTERNAL WATER SUPPLY AND SUPPLY FOR DESERT COOLER WORKS" as listed in Schedule ‘A’ Section - VIII (Part-I)
Sch 'A' Sec - VIII (Part-II), ( EXTERNAL WATER SUPPLY AND SUPPLY FOR DESERT COOLER WORKS)
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 100mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed. Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.
Supply and fixing cast iron sluice valve 80 mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, steel spindle, CI gate with brass ring, iron wheel handle, suitable for CI/DI pipe line, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve 100 mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, steel spindle, CI gate with brass ring, iron wheel handle, suitable for CI/DI pipe line, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.
Material and labour for Construction of brick masonary valve pit chamber size 90 X90 X90 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.
Material and labour for Construction of brick masonary valve pit chamber size 60 X60 X60 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.
Supply and fixing DI fitting upto 200 mm bore pipe line for reducing/bends (any type radius and angle) tapers any type, straight, bend, increasing decreasing or double socket extra Tee pieces single branch Y 'Junction' double branch cross collers cap etc complete all as specified and as directed. Note:- Make of DI fittings shall be same make as DI pipe or as per recommendation of DI pipe manufacturer.
Subtotal
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION, HIGH MAST LIGHT AND LIGHTNING PROTECTION WORKS" as listed in Schedule ‘A’ Section - IX (Part-I)
Sch 'A' Sec - IX (Part-II), (EXTERNAL ELECTRIFICATION, HIGH MAST LIGHT AND LIGHTNING PROTECTION WORKS)
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board, HT/LT equipments, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and fixing energy efficient LED street light fitting of 45W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection with suitable size of wire from junction box to street light fitting, fixing the light fitting with and including bracket made out of GI tubing light grade 32mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 105 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : Minimum IP65. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Sand cushioning, with dry and clean river fine sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. Note:- (i) Punned thickness shall be considered for payment purpose (ii) Approved river sand free from vegetations, grass and other deleterious substances shall be used.
Supply and fixing three core core (3x1.5sqmm) flexible flat/round cable, copper conductor multistranded, PVC insulated and overall PVC sheathed, 1100 volt, drawn through LT steel tubular poles for connection to street light from junction box to light complete all as specified and as directed.
Supplying, erecting, testing and commissioning Raising and Lowering type (16 metre height high mast system hot dip galvanised inside and outside) in single dip, suitable for wind velocity as per IS 875 part 3 with only one longitudinal seam weld per section but without circumferential weld including accessories viz head frame, 2 point suspension system with steel wire rope 6 mm dia 7/ 19 gauge, double drum winch, galvanised lantern carriage arrangement suitable for and with 8 nos Luminaires symetrically lightening finial, LED aviation obstruction light,lightening arrestor spikes,foundation bolts,nuts, anchor plates, templates, trailing cable and intergral power tool for raising and lowering operation of high mast with and including following technical specification:-
(a) HIGH MAST SYSTEM Height of Mast - 16 m No of sections - two Material construction - S355 grade as per BS-ENI00025 Base dia and top diameter (A/F) - 360 mm and 150 mm respectively Plate thickness 3mm minimum Cross section of Mast - 20 sidde polygon standard for of galvanisation - As per BS EN ISO 1461/BS729/IS2629 Size of opening and door at base - 1200 mm X 250 mm Diameter of base plate - 520 mm minimum Thickness of base plate - 25 mm Lightning protection finial - GI single spike Maximum Wind speed - 50 m/s as per IS 875 (Part-III) Number of foundation bolts - 6 Nos minimum PCD of foundation bolts - 445 mm minimum Type/diametre/length of foundation bolts - TS 600/24 mm dia/750 mm long minimum
(b) LUMINAIRES CARRIAGE Material of construction - 50 NB ERW Class 'B' MS pipe Diameter of carriage ring (mm) - 535 mm (ID) minimum Construction - 8 arm welded 2 sections Load carrying capacity 8 Luminarie (c) WINCH / POWER TOOL Type/SWL of winch - Double Drum /350 Kg minimum Method of operation - Integral Motor or manual Motor Capacity - 0.75 HP to 1 HP Three Phase No of Speed - 6 Pole, Single Speed
(d) STAINLESSS STEEL WIRE ROPE Grade/Construction - AISI304, 7/I9 Construction No of Ropes - Two Diameter (mm) - 6 mm Braking load capacity (minimum) - 2150 Kg x 2
(e)FEEDER PILLAR Powder coated CRCA steel sheet feeder piller housing 3.15 mm thick (minimum) suitable for outdoor application with 63 amp four pole MCB incomer, Nature switch, 16 amp, 420 volts suitable for automatic switching ON and OFF of the luminaries, 9 Amp two contactors and raise lower push buttons for motor operation, incoming terminals of 50 Sqmm and outgoing terminals of 16 sqmm for power cable and 2.5 sqmm for motor mounted on suitable foundation (f) FOUNDATION Construction of suitable shallow foundation with M20 grade concrete for high mast considering the safe soil bearing capacity at site as 10T/sqm at 2 m depth
(g) TRAILING CABLE PVC insulated PVC scheathed 1100 volt grade ISI marked multistranded copper conductor cable 6 core 2.5 sqmm (h) FLOOD LIGHT LUMINAIRE Eight number LED flood light luminaires 200 W IP 66 LED Flood light luminaire comprising of epoxy powder Die-cast aluminium housing with weather proof gasket for lamp & driver compartment with system wattage of 120 W . The LED must be of 120 degree view angle, > 100 lumen/ watt, lumen maintenace > 70% at 50000 hrs, color temperature of 5000-6500K, >70 color rendering and LM 80 test compliance. The driver must be integral APFC and constant current type having CRI > 80% THD<10% and power factor >0.95 with short circuit protection, open circuit protection, reverse polarity protection, high voltage protection, protection against 5 kV high surges and comply to IEC 60598-1, IEC 61000-3-2, IEC 61547 including PVC insulated three core 1.0 Sqmm FRLS multistranded Copper conductor cable for connection of fitting from gd installed junction box to top hight of pole. The luminaire must have secondary optics with perfectly matched lens for better light control.
Supply and fix FRP box of size 210mm x 155mm x 92 mm suitable for LT cable 10 to 16 Sqmm 4 core, Hinged (L0 with 4 way connector mounted on epoxy insulators for looping of cable for 3 phase and 1 Nutral fixed on pole with the help of MS nuts bolts and MS clamps -2 Nos of size 40 mm X 4 mm thick with one No MCB SP 2.5 Amp capacity mounted on din rail inside box . work also includes making suitable hole in pole to take out connections to fitting if required at site complete all as specified and as directed by Engineer-in-charge.
Material and labour for boring of holes under main road pavement, hard standing or any other situation by manual mean for accommodate 50mm bore GI tube (light grade) in the drilled holes, including returning, filling in the end working space including removal of surplus soil and making good the surface complete all as specified and as directed. Note ; (GL pipe and cable shall be measured and paid separately)
Supply, installation, commissioning and testing of factory made cubical type LT panel duly powder coated of suitable size outdoor cubical type factory made, weather & vermin proof made out of CRCA sheet 3.15mm (outdoor type) thick machine pressed with bottom frame made out of angle iron 40 mm x 40 mm x 6 mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body complete and suitable for 415 Volt AC 3 phase, 4 strip having insulated Copper bus bar 315 Amps from pole with openable double shutter on both sides (rear and front side) with locking arrangment duly pre-wired with suitable size of copper conductor cable fitted with Incomingproper size copper lugs/thimbless and connecting the incoming and outgoing MCCBs with suitable size strip duly bended and drilled and fixed with nuts, bolts & washers from bus bar to MCCBs etc duly fitted with and including the following accesories & all connected items complete. (FP-1)
MCCB 200 Amps, four pole with fixed thermal magnetic release, 415 V AC supply, having rupturing capacity 36 KA - 01 No (Incoming)
MCCB 63 Amps, Four pole with fixed thermal magnetic release, 415 volts having rupturing capacity 16 KA - 2 Nos (Outgoing)
MCCB 40 Amps, Four pole with fixed thermal magnetic release, 415 volts having rupturing capacity 16 KA - 2 Nos (Outgoing)
(a) MCB 20 Amp TPN - 02 Nos (b) MCB 10 Amp TPN- 02 Nos (c) MCB 25 Amp SPN - 03 Nos (all Outgoing)
Indicating lamps set RYB - 01 Set
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Supply, installation, commissioning and testing of factory made cubical type LT panel duly powder coated of suitable size outdoor cubical type factory made, weather & vermin proof made out of CRCA sheet 3.15mm (outdoor type) thick machine pressed with bottom frame made out of angle iron 40 mm x 40 mm x 6 mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body complete and suitable for 415 Volt AC 3 phase, 4 strip having insulated Copper bus bar 100 Amps from pole with openable double shutter on both sides (rear and front side) with locking arrangment duly pre-wired with suitable size of copper conductor cable fitted with Incomingproper size copper lugs/thimbless and connecting the incoming and outgoing MCCBs with suitable size strip duly bended and drilled and fixed with nuts, bolts & washers from bus bar to MCCBs etc duly fitted with and including the following accesories& all connected items complete:-
MCCB 63 Amps, four pole with fixed thermal magnetic release, 415 V AC supply, having rupturing capacity 16 KA -01 No (Incoming)
MCB TPN 32 Amp -01 No (Outgoing)
MCB TPN 16 Amp -01 No (Outgoing)
MCB TPN 6 Amp -05 Nos (Outgoing)
Indicating lamps set RYB - 01 Set
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Supply, installation, commissioning and testing of factory made cubical type LT panel duly powder coated of suitable size outdoor cubical type factory made, weather & vermin proof made out of CRCA sheet 3.15mm (outdoor type) thick machine pressed with bottom frame made out of angle iron 40 mm x 40 mm x 6 mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body complete and suitable for 415 Volt AC 3 phase, 4 strip having insulated Copper bus bar 100 Amps from pole with openable double shutter on both sides (rear and front side) with locking arrangment duly pre-wired with suitable size of copper conductor cable fitted with Incomingproper size copper lugs/thimbless and connecting the incoming and outgoing MCCBs with suitable size strip duly bended and drilled and fixed with nuts, bolts & washers from bus bar to MCCBs etc duly fitted with and including the following accesories & all connected items complete FP No 2 :-
MCCB 63 Amps, four pole with fixed thermal magnetic release, 415 V AC supply, having rupturing capacity 16 KA -01 No (Incoming)
MCB TPN 32 Amps-01 No (Outgoing)
MCB TPN 10 Amp -03 Nos (Outgoing)
MCB TPN 6 Amp-02Nos (Outgoing)
MCB SPN 10 Amp -02 Nos (Outgoing)
Indicating lamps set RYB - 01 Set
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Supply and fixing on pole/wal/in panel, Sheet metal enclosure Bus bar chamber made out of CRCA sheet 3.15 mm thick powder coated consisting 04 pole 32 Amp 415 volts copper bus bar Each Set suitable for connecting cable as a (junction incoming & outgoing total No 4 ways) including connecting of existing cables with suitable sizes aluminum thimbles complete all as specified and as directed by Engineer-in-charge.
Subtotal
Sch 'A' Sec - X , (SUMMER APPLIANCES AND WALK IN COLD STORAGE WORK)
Supply, installing, commissioning and testing frost free refrigerator electric driven single phase 220 volts, AC 50 Hz, 310 ltrs or next higher capacity with BEE approved, minimum 3 star rating double door, stablizer free operation, Inverter Technology, R600a Refrigerant,LED display, tempered glass self, deodorizer and with fruit & vegitable drawer complete all as specified and as directed.
Supply, installing, commissioning and testing frost free refrigerator electric driven single phase 220 volts, AC 50 Hz, 195 ltrs or next higher capacity with BEE approved, minimum 3 star rating double door, stablizer free operation, Inverter Technology, R600a Refrigerant,LED display, tempered glass self, deodorizer and with fruit & vegitable drawer complete all as specified and as directed.
Supply, installing, commissioning and testing Water Cooler fully stainless steel, electric driven single phase having approx storage capacity of 80 Ltr and nominal cooling capacity of 40 Ltr per hour with inlet PVC connection pipe of size 15 mm dia and 600 mm long of good quality complete with both ends CP nuts including electric connection through Voltage stablizer complete all as specified and as directed.
Supply & installing of Voltage stabilizer for automatic operation having input & output voltage, Amps, Over & low voltage cutout and timer delay function etc digital display single phase naturally air cooled indoor type & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA with wall mounting bracket complete all as specified and as directed.
Supply and Installation of Desert cooler electric driven single phase 230 volts steel body having nominal air flow capacity of 4000 Cu M per hours factory made GI sheet body 18 SWG and side panells of 22 SWG, water sump capacity not less than 40 ltrs, including water pump submesible type of suitable capacity ISI marked, with and including of fixing float valve of size 15 mm dia , PVC connection of suitable size and GI union of same size, complete including electric connection complete all as specified and as directed. Note (a) : Sufficient length of 3 core PVC sheathed round copper cable size 23/.0076 to enable fixing in to plug point shall be provided by contractor. (b) Arrangement of power connections and water connections to the desert cooler will be included in installation. (c) No extra payment shall be made for float valve, nut, wahser PVC connection, leakproof joints etc and making connection from GI pipe 15 mm dia to desert cooler in this regards, union for GI pipe ball valves brass complete (d) GI Pipes shall be measured and paid seperately under respective item.
Supply, installing, commissioning and testing of walk in freezer of size 10 feet x 10 feet x 8 feet (external size) with minimum 100 mm thick Cyclopentane panels and accessories (Lights, Flashing internal and external, U profile, Silicon Sealants etc), 02 Nos of CFC Free Refrigeration machines of capacity 8786 BTUH (1 No working + 1 No standby) for desired temp of -18 degree Celsius to - 20 degree Celsius including temp control panels with display and 1 No of door with interconnecting circuit of Copper piping max 20 Ft complete all as specified and as directed.
Supply, installing, commissioning and testing of ante room of freezer of size 10 feet x 5 feet x 8 feet (external size) with minimum 60 mm thick Cyclopentane panels and accessories (Lights, Flashing internal and external, U profile, Silicon Sealants etc) with 1 No of door for Ante Room and with interconnecting circuit of Copper piping max 20 Ft complete all as specified and as directed.
Supply, installing, commissioning and testing interconnecting circuit between one set of Evaporating and Condensing Unit for refrigeration system above 20 Ft complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “SOLAR WATER HEATER AND HOT WATER SUPPLY WORK" as listed in Schedule ‘A’ Section - XI (Part-I)
Sch 'A' Sec - XI (Part-II), (SOLAR WATER HEATER AND HOT WATER SUPPLY WORK)
Supply, installing, commissioning and testing of Solar Water Heating system (Flat Plate Collector) based on indirect transfer of heat of capacity 200 Ltrs Per Day including electric backup stainless steel hot water tank suitable for inlet water with chlorine and fluoride content up to 100 PPM and comprising of solar flat plate collector, collector stand assembly with collector 'A' Size aluminium box collector comprising of following :-
Insulated stainless steel Hot water storage tank non pressure type made of stainless steel grade 04 Cr 18 NI or 07 Cr 18 NI of IS 1570 (Part-3)-1985, TIG Welded of 200 Ltrs capacity, non-magnetic tank with stainless steel fittings with following specification -01 No shall be insulated with 40 mm thermal grade PU insulation with FRP Cladding Tank stand assembly shall be made of Size 38 x38 x 4 mm duly pre-treated and stove enamelled with black colour paint.
Provisions of electrical back up with min 3 KW heating element - One Job Solar water heating system shall be provided on roof of single / double storey building. The electrical back up connection shall be tapped from sub main board provided at ground floor.
Heat exchanger shall be cage type and made of stainless steel tube of grade 04 Cr 18 NI or 0718 NI of IS 1570 (Part-2) 1885
All other pipe /civil work, steel staging work for PVC tank, electrical work, outlet and inlet thermometer, air release valves, check valves, gate valves, controls and instruments etc. all as required shall be deemed to be included in unit rate quoted by the contractor for this item. System internal piping shall be ISI Marked GI pipe medium class of IS: 1239 duly insulated with 50 mm thick rock wool of 48 Kg/M3 Density and 26 SWG AI Cladding.
Supply, installing, commissioning and testing of electric water heater (Geyser) storage type ABS body of capacity 25 litre, BEE approved 5 Star rating, 230 V , single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as safety valve, thermostate, NRV, connection piece PVC connection for HOt and cold water, three core PVC insulated PVC Sheathed copper conductor flexible cable including 15 Amp plug suitable for existing socket and fixing material, 04 no Nut bolt grouting in wall in PCC (1:2:4) using 12.5mm graded stone aggregate for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge.
Subtotal
Lump sum price worked out by the tenderer for “EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORK" as listed in Schedule ‘A’ Section - XIII (Part-I)
Sch 'A' Sec - XII (Part-II), (EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORK)
Material and labour for supplying approved earth from outside MOD land (irrespective of any lead) and Forming Embankments incl raising (or lowering) earth, spreading in layers not exceeding 30 mm thick, watering, ramming/rolling and finishing to required size, shape not exceeding 1.5 metre high from base complete all as specified and as directed. (a) Only consolidated thickness of earth will be measured and paid. (b) Quality of earth shall b approved by GE in writing prior to execution.
Subtotal
Lump sum price worked out by the tenderer for “DISMANTLING AND DEMOLITION WORK" as listed in Schedule ‘A’ Section - XIII (Part-I)
Sch 'A' Sec - XIII (Part-II), (DISMANTLING AND DEMOLITION WORK)
Disconnecting and taking down PVC water tank 500 ltr capacity any condition and removing from site complete all as specified and as directed by Engineer-in- charge.
Dismantling existing galvanised barbed wire of any type, size and thickness complete all as specified and as directed by Engineer-in-Charge. (each line wire to be measured)
Taking down existing point wiring any type (light/fan/sockets/bell/power point etc) complete with all accessories such as switch socket with sheet, ceiling rose, lamp holder including conduit, junction and sunken boxes etc and removing dismantled material complete all as specified and as directed by Engineer-in-Charge.
Disconnecting and taking down electrical lights, tube lights etc (internal fttings any type) and removing from site complete all as specified and as directed by Engineer-in- charge.
Disconnecting and taking down old Street light any type along with bracket from from pole and removing from site complete all as specified and as directed by Engineer-in- charge.
Subtotal
GAURI SHANKAR AGGARWAL
M/s Jatindra Construction Company
A.V BUILDERS
Dasmesh Buildcon
A S CONSTRUCTION COMPANY
M/S Shiv Shakti Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid