| 1 | L1₹7.3 LAccepted-Finance PASCHIM KHILKAPUR G P BARASAT BLOCK 1 | PASCHIM BARDHAMAN | WEST BENGAL | 713148 | L1 | Accepted-Finance 1st lowest | |
| 2 | L2₹7.3 L+₹7,403 (1.02%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹7.4 L+₹14,727 (2.03%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹18,170
Closing Date
20 Jan 2026, 12:30 pmClosed
Executive Engineer, PWDte
Bankura
Establishment of a Computer Assisted Learning Laboratory (CAL) at Pharmacology Department at Natun Bhawan under Bankura Sammilani Medical College , Bankura.-------Electrical Renovation work
2026_WBPWD_984308_1
WBPWDTE/EE/BED/NIQ_48/Q of 2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Wise
45 days
Pharmacology Department at Natun Bhawan
Please refer Tender documents.
3 documents required · 3 mandatory
₹18,170
30 Jan 2026
6 Jan 2026
27 Jan 2026
10 Jan 2026
20 Jan 2026
10 Jan 2026
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make: Legrand/Seimens/Schneider/L&T) as to GS 8-way Enclosure.
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection as to GS. (Make: Legrand/Seimens/Schneider/L&T) 415 V, 63A FP
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection as to GS. (Make: Legrand/Seimens/Schneider/L&T) 6A - 32A SP MCB
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 10 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. On board
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works 25 mm
Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(For Single Phase AC)
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections (For Single Phase AC)
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 x 4 sq mm + 1 x 2.5 sq mm (For AC Machine & Power Board)
Supplying of 1.1 KV Grade following sizes Al. Armoured PVC/ XLPE Cable ( Make: Havells/ RR Kable/Polycab/Gloster ) as per the direction of EIC 4 core 35 sq mm ( from VTPN to HTPN DB )
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. Up to 50 sqmm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 35sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials . 4 core 35sqmm
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 2.5 sq mm
Supply & Delivery of twin LED Tube light fittings (Make- Signify (Philips), Cat No. TMC-502 2XT-LED 22W or equivalent model of CG Fittings- IGP162 LT8-16 2 x T8 with 02 Nos LED TUBE Philips Cat No- Mas LEDTube 1200mm 18W 865 T8 I – 2100lm /Crompton- Cat No- LTB-20-865-(2) or equivalent model of Surya/Bajaj)
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply and Fixing of Timer DB (concealed in wall or Surfaced as per the site condition) 1) 230V, Upto 16 A capacity 24 Hrs Analog Electromechanical Time Switch (Make-Lauritz Knudsen (L&T) Cat No:- AUTS03ANA00/Siemens/Schneider) 2) 2 Pole Power Contrcator (L&T-MNX 25-2P Cat No-CS90240/Siemens/Schneider ), 3) 20A SP MCB. [Make-Siemens/Schneider/Lauritz Knudsen (L&T)] 4) 32A DP Isolator. (Make-Siemens/Schneider/Lauritz Knudsen (L&T) ) 5) Toggle Switch. (Make-Siemens/Schneider/Lauritz Knudsen (L&T) or equivalent make) 6) (2+12 Way) SPNDB (Make-Siemens/Schneider/Lauritz Knudsen (L&T) 7) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar etc with this box for termination of power. 7) The complete arrangement must be wiring by 1/2.5/4/6 Sq mm PVC insulated Cu wire(Make:- Gloster/Polycab/Havells) with suitable length incl socketing /lugs etc as per requirement & direction of EIC. (Make-Siemens/Schneider/Lauritz Knudsen (L&T)/Legrand)
Supply & Fixing of 250V 50 HZ OLP- single phase A.C Starter (Make -Electron, / PWD Appvd ) suitable for 1.5 / 2.0 /2.5 TR Airconditioner Machine incl S & F suitable size G I box (16 SWG) flushed in wall with voltage check, Amp check, Time check incl. making connection as per direction of EIC. 30 A
Supply , Delivery , Installation & Commissioning of 230V, 50Hz 2.0TR capacity Non-inverter (Fixed Speed) type Hi Wall Split Air-Condition Mcahine (Make-O General Extreme Cooling series Model no ASGA24BMWA-B(R-32) or equvalent model of Hitachi /Daikin/ Mitsubishi Heavy/Mitsubishi Electric) with Remote, fitting accessories etc.
Supply andlLaying of 5/8” or 1/2"& 1/4" dia (Soft drawn) Cu. Pipes (As per standard) with tube thickness 0.6mm incl. 9mm thick nitrile rubber insulation, , insulation tape, fastner, etc as necessary as per direction of EIC. Copper Pipe Make: Hitachi Ryoku/Mandev/Rajco) & Nitrile Rubber Insulation Make: Armacel/Accoflex/K-flex) (extra length for distance of ODU & IDU exceed 3 mtr.)
S& Laying 3 core 2.5 sqmm PVC insulated & unarmoured copper wire (make-- Finolex/Havells/KEI) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr distance as per direction of EIC. (Make-Gloster/ Ploycab/Finolex / RR Cable.)
Supply & laying Drain Water piping work by PVC / HDPE hard pipe of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors. (Make- Oriplast / Supreme) 25mm dia
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.24 MB
BOQ_2401712.xls
BOQ • 0.37 MB
2911.pdf
Additional Documents • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .