| 1 | L1₹10.0 LAccepted-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹1.1 L−₹8.9 L (89.0%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹11.2 L+₹1.3 L (12.8%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹29.4 L+₹19.5 L (195.4%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹39,000
Closing Date
24 Nov 2022, 6:00 pmClosed
GE MH and RH KIRKEE
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Kirkee Pune 411003
REPAIR MAINTENANCE OF 0.6 MLD MBBR STP AT MH KIRKEE UNDER GE MH AND RH KIRKEE
2022_MES_560268_1
8345/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE MH and RH KIRKEE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH and RH KIRKEE
₹39,000
22 Feb 2023
28 Oct 2022
26 Nov 2022
28 Oct 2022
24 Nov 2022
12 Nov 2022
28 Oct 2022 - 17 Nov 2022
Amount
Taking out of existing non clog submersible pump set from raw water sewage sump after disconecting the electric connection complete . Dismantling the pump & electric motor , cleaning of blockage sludge equalization servicing of pump , motor including necessary oiling ,greasing etc complete checking of other parts pump,motor including replacement of minor parts like bush bearing , pin nut bolts etc checking of insulation resistance of motor winding , varnishing of motor winding with "F" class insulation and reassembled the same and reinstalled to its original position complete all as specified and directed by Engineer-in-Charge of following capacities. Note: (i) winding shall be measured & paid seprately under relevent item of this BOQ (Schedule A). (ii) The rate for necessary T&P required for taking up and down of submersible pump / motor shall be deemed to be included in unit rate quoted.
3 HP Raw sewage tank ,415 volt 50HZ AC
7.5 HP 415 volt 50HZ AC Raw sewage tank
12.5 HP 415 volt 50HZ AC Raw sewage tank
3 HP 415 volt 50HZ AC Equalization tank .
Dismantling the coupling and taking out 7.5 HP pump ( make- Kirlosker) from pump motor set fixed in foundation and transport to work shop opening the pump, replacement unserviceable bearing and bushes and worn out nut and bolts gaskets, machining of shafts, over hauling & greasing of pump and reassembling the same including replacement of worn out gland packing with suitable size after fixing with motor, testing of motor and pump with full load at site complete all as specified and directed by Engineer-in- charge.
Disconnectioning of electric connection and taking out burnt electric motor from foundation /centifuge for repair in local workshop ,opening of motor for rewinding with super enamelled copper winding wire of existing gauge and varnishing, beaking and testing after rewinding upto the entire satisfaction of Engr-in-Charge rewinding, reassembling and fixing to its original location of following capcities complete all as specified and directed by Engineer-in- charge. Note: Spare parts such as bushing, bearing etc shall be deemed to be included in unit rate quoted.
3 HP, 3 Phase, 440 Volt Make- CG location Centifuge ( centifuge house).
7.5 HP, 3 Phase, 440 Volt feed pump motor. Make : CG , Location :STP MH kirkee
15 HP, 3 Phase, 440 Volt Air blower motor. Make : CG , Location : Air blower room STP MH kirkee
0.5 HP, 3 Phase, 440 Volt Screw pump and slow moving agitator motor. Make :Kirloskar
M & L for servicing of compressor with air blower of 600 Cum/hr capacity unit replacement of compressor oil, air filter, oil filter,etc complete all as specified and directed by Engineer-in- charge. Model : M5175 Note: compressor oil, air filter, oil filter etc shall be deemed to be included in unit rate quoted.
Disconnectioning of electric connection and dismantling and taking out burnt electric motor non clog submersible pump from sewage sump for repair in local workshop ,opening of motor for rewinding with super enamelled copper winding wire of existing gauge and varnishing, heating and testing after rewinding upto the entire satisfaction of Engr-in-Charge rewinding reassembling and fixing to as its original location of following capacities complete all as specified and directed by Engineer-in- charge. Raw sewage sump and equalization tank
3 HP, 3 Phase, 440 Volt
7.5 to 12.5 HP, 3 Phase, 440 Volt
Supply and fixing in repairs fan belt for compressor of SPA 1360LP Make Ecodriver or equivalent complete all as specified and directed by Engr- in -charge.
Supply and fixing in repairs fan belt for centifuge Make Ecodriver or equivalent complete all as specified and directed by Engr- in -charge.
Supply and fixing in repairs heavy duty contactor of capacity as per existing for starter panel complete all as specified and directed by Engr- in -charge. Make L&T, Siemens, or equivalent make given under list of makes.
Supply and fixing in replacement fine bubble air diffuser type 63-1000 membrane OD 63 mm length 1000 mm air flow rate 7.0 – 10.0 m3/hr including taking down complete all as specified and directed by Engineer-in- charge.
Supply and fixing in repairs cast iron butterfly valves with CI disc ‘ISI ’ marked lever operated PN-1.6 of following size including taking down complete all as specified and directed by Engineer-in- charge. Make : GM / Normak / Cair or equivalent make given under list of makes.
200 mm dia
150mm dia
100mm dia
80mm dia
50 mm dia
Supply and fixing in repairs Diaphragram valve ‘ISI ’ marked of various size including takingdown complete all as specified and directed by Engineer-in- charge. Make : GM/Normak or equivalent make given under list of makes.
80 mm dia
25 mm dia
M&L Pebbles for change of filter media pressure type in the sand filter and activated carbon filter including opening and reassebling carefully up to entire satisfaction of Engr-in-charge
Pebbles of size 25-40mm
Pebbles of size 12-25mm
Pebbles of size 6-12mm
Pebbles of size 2-6mm
Activated carbon
Quartz sand 0.3 mm to 0.5 mm
Supplying & fixing to walls and ceiling or laying in trenches/ ducts, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete of following sizes all as specified and as directed
50 mm Bore
25 mm Bore
Supply and laying in replacement UPVC Pipe grade (SCH-80) IS specification 4985/1988 sustainable pressure not less then 10 Kg/Cm2 of following size, including necessary fittings such as tees, bends elbows & reducer etc complete as specified directed Make : Supreme/SFMC or equivalent make given under list of makes.
100 mm dia
50 mm dia
Supply and lay in repairs M S Pipes B class heavy grade with all fittings,flange and nut bolts etc laid in floors or fixed to walls and ceilings etc of following size
100mm dia
150 mm dia
Taking down old unserviceable MCCB from panel and supply and fix new MCCB 3 pole of capacity 400 Amps ,415 volts ,50 Hz AC, 36 KA with thermal and magnetic release confirm to IS /IEC 60947-2 including necessary disconnecting & reconnection of existing size of cable complete all as directed by Engineer-in-Charge Make Standard/L&T/ C&S or equivalent make given under list of makes.
Taking down old unserviceable MCCB from panel and supply and fix new MCCB 3 pole of capacity 250 Amps ,415 volts ,50 hZ AC, 36 KA with thermal and magnetic release confirm to IS /IEC 60947-2 including necessary disconnecting & reconnection of existing any size of cable complete all as directed by Engineer-in-Charge Make Standard/L&T/ C&S or equivalent make given under list of makes.
Taking down old unserviceable MCCB from panel and supply and fix new MCCB 3 pole of capacity 160 Amps ,415 volts ,50 hZ AC, 25 KA with thermal and magnetic release confirm to IS /IEC 60947-2 including necessary disconnecting & reconnection of existing any size of cable complete all as directed by Engineer-in-Charge Make Standard/L&T/ C&S or equivalent make given under list of makes.
Taking down old unserviceable MCCB from panel and supply and fix new MCCB 3 pole of capacity 63 Amps ,415 volts ,50 hZ AC,16 KA with thermal and magnetic release confirm to IS /IEC 60947-2 including necessary disconnecting & reconnection of existing any size of cable complete all as directed by Engineer-in-Charge Make Standard/L&T/ C&S or equivalent make given under list of makes.
Supply and fix in repair MCB TP 415 V,63Amps, with breaking capacity 10 KA, B curve complete all as specified and directed by Engr- in -charge Make standard/L&T/ C&S or equivalent make
Taking down old unservicable fully automatic star delta starter from existing panel and supply and fix new fully automatic starter suitable for motor AC 3 duty, 415 volts, 50 HZ,3 Phase upto 7.5 H P motor capacity complete with single phase preventor ,relay ,contactor etc including necessary disconnection & reconnection of existing electric cable of any size complete all as directed Make:TC/C&S/L&T or equivalent make given under list of makes.
All as per item No 21 above but starter suitable for motor capacity 15 HP Make:TC/C&S/L&T or equivalent make given under list of makes.
All as per item No 21 above but DOL starter suitable for motor capacity to 7.5 HP Make :TC/C&S/L&T or equivalent make given under list of makes.
Decorbonising of Auto Panel / LT indoor/outdoor Panels/feeder pillar box any type by disconnecting and removing all the incoming and outgoing cable connection from MCCBs, Cleaning of dust with air blower, burnt busbar, burnt timmbles, any type of insulators, cable tray, spiral piping , necessary cable tie, reconnection after proper cleaning of contracts with CRC solution and painting of complete panels including stand and door/ back outside ( after proper scrubbing) with systhetic enamel paint one coat as per specified colour code including writing of panel/feeder panel location using black systhetic paint and reconnecting the dismantled LT cables etc. complete all as specified and as directed by Engr- in - charge. Note: (i) Cost of labour, cotton waste and T & P required for upkeeping / maint work is inclusive is deemed to be included in unit rate quoted.
Supply, laying testing in repair of PVC insulated PVC round sheathed multistranded copper, unarmoured cable round in shape for voltage grade 1100 volts as per IS 694:1990 of size 3 core 2.5 Sqmm complete all as directed .
Supply, laying testing in repair of PVC insulated PVC round sheathed multistranded copper, unarmoured cable round in shape for voltage grade 1100 volts as per IS 694:1990 of size 3 core 6 Sqmm complete all as directed.
Dismantling the unserviceable pressure guage and S&F new pressure gause with pressure range 0-10 Kg/sq cm complete all as specified and directed by Engr- in -charge
Taking down old unserviceable phase indicating lamp from existing panel and Supply & Fix new phase indicator lamp LED type with holder and bulb for R.Y.B phase indication working on 240 volts, 50 HZ AC supply.
Taking down old unserviceable change over switch from existing panel and supply and fix on load changeover switch of 100 Amps 4 pole working on 415 volts AC supply open Execution including necessary disconnection and reconnection of existing cable complete all as directed. Make : Havells / L& T/ C&S or equivelent make given under list of makes.
M&L for preparation of old painted surfaces of various sizes valves / wheels,railling , stair case and open pipes inlet/ out let etc. by removing complete existing treatment and applying two coat of epoxy paint over a coat of zinc oxide primer. Colour / shade shall be as per existing tint for following items complete all as specified and directed.
Surface area of Chamber plate, open pipes inlet/outlet etc
Activated carbon filter tank (01 No) with connected pipe lines and accessories.
Activated sand filter tank (01 No) with connected pipe lines and accessories.
Air Blowers (02 Nos) with accessories and open pipes etc.
M & L for cleaning of various type process RCC tank as per below by Dewatering the water /sludge from inside of by the help of dewatering sewage pump and clean the interior portion of tank complete bottom portion all four side portion complete with the help and side of tank) by means of coir/wire brush etc and wash the interior portion by using and clear away of all sludge, vegetation, muds off the premises all as specified and directed. Note : For bar screen chamber tank.
Bar screen chamber tank
Raw sewage collection tank no-1 of (Dia 4.5 m and depth 10.5m) appox Capacity 166 Cum
Stilling chamber (1m x 1m x 2m), fine screen chamber (1m x 0.5m x 0.45m), grid chamber (1.8m x 1.0m x 1.0m), channel upto equalization tank appox capacity 5 Cum
Equalization tank of size ( 8m x 6m x 4m) of appox capacity 192 Cum
MBBR tank ( Aerartion) of size (8m x 4m x 3.9m) of appox capacity 125 Cum .
Tube settler tank of size (8m x 2.4m x3.7m) of approx capacity 72 Cum at STP
Chlorine contact tank (CCT) of size (8m x 2.2m x 3.5m) of approx capacity 62 Cum.
Sludge sump size of (2.6m x 2.4m x 2m ) of appox capacity 13 Cum
Treated water tank of size (16.23m x 3.4m x 4.5m) of appox capacity 250 Cum
M & L for Bar screen chamber for bar screen chanmber of existing size with thickness of 6 mm complete all as specified and directed by Engineer in Charge.
Supply and laying in replacement electric cable 50 Sq mm 3.5 core XLPE armoured, LT 1100 V grade heavy duty with stranded aluminium conductor through pipes/road crossing, in ducts, on poles, trenches etc of all as specified and directed by Engineer in Charge. Note :- Excavation and earth work, sand cushion, brick cover and protection pipe shall be measured separately under respective items.
Excavation in trenches not exc.1.5 m wide and not exc 1.5 m depth (for taking out and laying of water pipe line/cable and getting out in soft/ loose soil complete all as specified and directed.
Returning filling in trenches including spreading ,levelling,watering and well ramming in layers not exc 25 cm complete all as directed.
Removing of excavated material not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed
M&L for riddled earth cushioning to under ground cable in trenches / existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engineer-in-Charge. Note:- Measurement shall be taken after gentling running.
Supply and laying reinforced precast concrete cable cover class LV, type 2, flat of size 250mm x 150mm x 40mm size for cable protection.
Servicing for mobile lifting chain pully (1 ton capacity) fixed at existing submersible pump incl taking down unserviceable complete all as specified and directed by Engineer-in-Charge all included as one job
Servicing for mobile lifting chain pully (2 ton capacity) fixted at existing submersible pump incl taking down unserviceable complete all as specified and directed by Engineer-in-Charge all included as one job
M&L for cleaning of MES electric supply installations/campus by surface dressing or trimming of natural ground to remove small unequalities not exc 15 cm deep (including removing vegetation/ shrubs/brush wood/ under growth) and carrying away the rubbish to a distance of not exc 50 mtr away complete all as specified and as directed.
Supply only Liquid Sodium hypochloride for STP in required quantity for dosing in dosing tank all as specified and directed
Supply only bactacult for culture development in STP used in controlled manner all as specified and directed
Supply and fix Centifuge Screen bag JM centifuge model 60-5 in cenrtifuge all as specified and directed
Taking down old damged bar screen supply and fix in repair Bar Screen Chamber SS 6 mm thick slit chamber as per existing size all as specified and directed
Supply and fix 15 ft x 3 ft size, 3 mm ACP sheet Recto reflective Sign board of size on frame of MS tubing 40mm x 40mm, with 4 Nos support of 40mm tubing for board including side pillar of height 8 ft mounted on RCC columb on entrance door of STP MH made out of 40 x 40 mm Angle of 6mm thick of 4 Nos angle on each column with support at interval of 2 ft all as specified and directed by Engineer-in-Charge. Note : Contain of board finalise with the concerned of JE / Engineer-in-Charge.
Supply and fix 6 Ft x 4 Ft sign board made out of 3 mm ACP Sheet LG mark vineyal pasting on 0.75 x 0.75 inch MS frame with vertical side pole of ms angle of size 40 x 40 mm, 6 mm thickness with necessary excavation, PCC and copping all included all as specified and directed by Engineer-in-Charge. Note : Content of board finalize with concerned of JE / Engineer-in-Charge.
Supply and fix Sign board of Size 2 ft x 1 ft on 3mm ACP sheet LG mark vineyal pasting board with mirror screw including fitting all included all as specified and directed by Engineer-in-Charge Note : Content of board finalize with concerned of JE / Engineer-in-Charge.
Supply and fix Sign board of Size 2 ft x 1 ft on 3mm ACP sheet LG mark vineyal pasting board mounted on angle of 25 mm x 25 mm with 5 mm thick 3 ft long srewed fixed on wall / parapet with the help of fast nut and bolt, screws and welding to the existing structure fitting all included all as specified and directed by Engineer-in-Charge Note : Content of board finalize with concerned of JE / Engineer-in-Charge.
SKS Electricals
Adinath Technical Services
Panse Consultants
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .