Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAccepted-AOC VILL PO BUNGWAN KALAN TALBEHAT LALITPUR UTTAR PRADESH 284136 | TALBEHAT | LALITPUR | UTTAR PRADESH | 284136 | L1 | Accepted-AOC Reasonable rate | |
| 2 | L2₹12.2 L+₹1.7 L (16.5%)Rejected-Finance N S T COLONY CIRCULAR ROAD HOUSE NO 04 DMC DIMAPUR 797 112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L2 | Rejected-Finance Quoted amount higher than L1 | |
| 3 | L3₹16.4 L+₹5.9 L (56.5%)Rejected-Finance NEAR RAM JANAKI HIGHER SECONDARY SCHOOL H NO 03 THAKURBAR DIMAPUR NAGALAND 797112 | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L3 | Rejected-Finance Quoted amount higher than L1 | |
| 4 | L4₹16.5 L+₹6.0 L (57.1%)Rejected-Finance | L4 | Rejected-Finance Quoted amount higher than L1 | |
| 5 | L5₹16.9 L+₹6.5 L (61.7%)Rejected-Finance | L5 | Rejected-Finance Quoted amount higher than L1 |
Tender Value
₹12.2 L
EMD Value
₹24,500
Closing Date
12 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col NK Chaudhary
HQ 137 WKS ENGR PIN 914137 CO 99 APO
PROVISION OF ONE HIGH MAST LIGHTS ALONG WITH LUMINARIES AT ZAKHAMA MILITARY STN
2022_MES_557714_1
8678/E8
Open Tender
Civil Works
Item Rate
120 days
Zakhama
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
AGE (I) Zakhama
₹24,500
2 Jan 2023
14 Oct 2022
19 Nov 2022
14 Oct 2022
12 Nov 2022
29 Oct 2022
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil etc complete all as specified and as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep in hard / dense soil and getting out complete all as specified and as directed.
Material and labour for hardcore of broken stone / boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
Material and labour for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and as directed.
Material and labour for raised pointing to random or polygonal rubble, uncoursed or brought upto courses in CM 1:4 complete all as specified and as directed.
Material and labour for PCC 1:2:4 type B0 (using 12.50 mm graded stone aggregate) as in coping of poles including weathering, slightly rounded or chamfered angles and throating including necessary use and waste of formwork complete all as specified and as directed.
Material and labour for pre-polished precast Cement Concrete chequered tiles , area exc. 0.06 Sqm but n.exc. 0.11 Sqm, 25mm thick as in floor, set and jointed in neat cement slurry and pointed with white cement mixed with colour pigment laid over and including 20mm thick screed bed in CM (1:4) complete all as specified and as directed.
Material and labour for 75 mm thick PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in sub base of floor finished the surface fair and even complete all as specified and directed.
Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed .
Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed .
Supply & installation of Raising and Lowering type (height as per requirement) high mast system hot dip galvanized system in single dip, suitable for wind velocity as per IS 875 Part-III with only one longitudinal seam weld pre section but without circumferential weld including accessories viz head frame, 2 point suspension `system with steel wire rope min 6 mm dia 7/19 gauge, double drum winch, galvanized lantern carriage arrangement suitable for and with 9 luminaries symmetrically. Lightning finial, LED aviation obstruction light, lightning arrester spike, foundation bolts, nuts anchor plates, templates, trailing cable & integral power tool for raising and lowering operation of high mast with and including following technical specification :- a) High Mast System. 1. Height of mast – 16 mtr 2. No of section – Two 3. Material construction – S 355 grade as per BS-ENI0025 4. Base dia and top diameter (A/F) – 360 mm & 150 mm respectively 5. Plate thickness & section length – top 3 mm x 5420 mm,Bottom – 4mm x 10980mm 6. Cross section of Mast – 20 side polygon 7. Standard for galvanization – As per BS EN ISO 1461 8. Size of opening and door at base - 1050 mm x 225 mm 9. Diameter of base plate – 520 mm 10. Thickness of base plate – 25 mm 11. Lighting protection finial – GI single spike 12. Maximum wind speed – 50 m/s as per IS: 875 (Part-III) or as per site conditions. 13. Number of foundation bolts – 6 Nos 14. PCD of foundation bolts – 445 mm 15. Type /diameter/length of foundation bolts – TS 600/24 mm dia/750 mm long
(b) Luminaires Carriage (i) Material of construction – 50NB ERW Class „B‟ – MS pipe (ii) Diameter of carriage ring (mm) – 535 mm (ID) (iii) Construction – 6 arm or as required for mounting 09 Luminaries, welded, 1 sections/ part (iv) Load carrying capacity – 9 Luminaries
(c) Winch / Power Tool (i) Type /SWL of winch – Double Drum/350 kg (ii) Method of operation – Integral motor/ Manual (iii) Motor capacity – 1 HP Three Phase (iv) No of speed – 6 Pole, single speed (d) Stainless Steel Wire Rope (i) Grade/construction – AISI304, 7/19 construction (ii) Number of ropes – Two (iii) Diameter (mm) – 5 mm (min) (iv) Braking load capacity – 1450 kg x 2 (v) Trailing Cable (1 sets 5 core x 2.5 sq. mm. EPR PCP Round Copper). Note : (i) Guranteed Technical parameters and foundation drawing should be prior approved by Engr-in-chage before placing the final order by the contractor. (ii) Installation of high mast to be carried out by the rep of manufacturer and the cost of foundation deemed to be included in the quoted rate.. (iii) Neccesary cable/ wire to connect the flood light luminaire from Junction box at bottom to ight mounting channel is inclusive in the quoted rates. (iv) Rate of feeder pillar is exclusive in the quoted rate. Make : Bajaj/ Crompton Greaves/ Nezone (Ntl)/ Utkarash.
Supply and fix LED Flood light 140 /150 Watt IP 65, 6KV high surge protection,Correlated Color Temperature : Cool White (5500K or more) and technical specifications as given below:- (i) Color Rendering Index: Typical 70 (+/ -5%) (ii) Lumen Maintenance : 70% of initial output (L70)@ 60,000 hrs (iii) LED Source Efficacy : 100 lumen/ W (iv) LED Luminaire Efficacy : 90 lumen/W ( As per LM79 test report) (v) Driver efficacy : > 85% (vi) Driver in- built surge voltage Protection : minimum 10 KV (vii) Luminaire Lumen Output : > 21600 lumen ( as per LM79 test report) (viii) Power Factor: > 0.95. (ix) Name of the manufacturer to be embossed (no painting / stickering) on the luminaire. (x) Optical Performance: Each LED to be provided with specially designed lens to get optimum optical performance. (xi). Driver Protection: short circuit., Over Load, Open circuit. and no load complete all as specified and directed. (xii) LM79 test report document of LED luminaire from NABL accredited lab, not more than 1 year old from the date of issue of tender (xiii) LM 80 test report document of LED source. (xiv)Type test report of LED luminaire, from NABL accredited lab, not more than 1 year old from the date of issue of tender, (xv) Warranty certificate for Min 03 Years for luminaries should be submitted by the contractor. Make : Bajaj/ Philips/ Wipro/ Syska Led/Havells/ Jaquar.
Supply, laying and testing underground cable, XLPE, Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty), 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core and complete all as specified and directed. Note : Excavation and earth work will be paid seperately under respective item of schedule.
Supply, laying and testing underground cable, XLPE, Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty), 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core and complete all as specified and directed. Note : Excavation and earth work will be paid seperately under respective item of schedule.
Supply and Fix end termination joints, indoor / outdoor type, designed to withstand exposure to extreme climatic variations & surface contamination, UV rays from sunlight and electrical stress caused due to heavy pollution & dust in external conditions. 1100 Volt, XLPE, Heat Shrinkable, suitable for cable 16 sq mm, 3.5/4 Core and complete all as specified and directed by Engr-in-Charge. Note : (i) The accessories shall be supplied in kit form. Each component of the kit shall carry the manufacturer’s mark of origin. (ii) As per the IS 13573 (Part-I&II):2011 all kits shall be marked and labeled suitably for identification.
Supply and Fix End termination joints, indoor / outdoor type, designed to withstand exposure to extreme climatic variations & surface contamination, UV rays from sunlight and electrical stress caused due to heavy pollution & dust in external conditions. 1100 Volt, XLPE, Heat Shrinkable, suitable for cable 25 sq mm, 3.5/4 Core and complete all as specified and directed by Engr-in-Charge. Note : (i) The accessories shall be supplied in kit form. Each component of the kit shall carry the manufacturer’s mark of origin. (ii) As per the IS 13573 (Part-I&II):2011 all kits shall be marked and labeled suitably for identification.
Materials and labour for earthing complete with copperearth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with copper strip of 20 x 3 mm size by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking out unserviceable earthing plate and accessories all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Supply, installation, testing and commissioning of Feeder Pillar: Powder coated CRCA steel sheet feeder pillar housing 2.0mm thick (minimum) 9 amp 2 contactors and raise lower push buttons for motors operation, incoming terminals of 25 sqmm and outgoing terminals of 16 sqmm for power cable and 2.5 sqmm for motors mounted on suitable foundation. factory made powder coated (CPRI approved) LT panel board, outdoor type, weather, dust and vermin proof (IP-64), made out of CRCA sheet 2 mm thick with base frame of angle iron 25x25x3 mm suitable for 415 volts, 3 phase,50 Hz, 4 wire system with front side openable with single shutter, hinged and locking arrangement and slanted roof. The size of panel boards shall be suitable for housing the accessories given here under. The panel board shall comprise of following items with and including necessary connection complete all specified and directed:-
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to requirred thickness complete all as specified and as directed. (Note: Thickness of sand cushioning after punning down shall be measured for payment purpose)
Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed.
SHRI VIKASHE ZHIMOMI
SHRIi Bachulal shah
satyabhama and co
commercial enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .