Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC VPO BAILLY TEHSIL DALHOUSIE DISTT CHAMBA HP PIN 176303 | CHAMBA | HIMACHAL PRADESH | 176303 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹8.5 L+₹47,635 (5.96%)Rejected-Finance H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹8.6 L+₹64,571 (8.08%)Rejected-Finance NEAR CIVIL HOSPITAL WARD NO 07 VPO CHOWARI DISTT CHAMBA HP 176302 | CHOWARI | CHAMBA | HP | 176302 | L3 | Rejected-Finance Being Not L1 | |
| 4 | L4₹9.1 L+₹1.1 L (13.4%)Rejected-Finance 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Being Not L1 | |
| 5 | L5₹9.1 L+₹1.1 L (13.8%)Rejected-Finance | L5 | Rejected-Finance Being Not L1 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
21 Aug 2021, 6:00 pmClosed
AGE(I) Dalhousie
AGE(I) Dalhousie PIN-176305
CERTAIN REPAIRS AND REPLACEMENT TO ROOF FALSE CEILING WALL PLASTER AND MISC WORKS AT MES INSTALLATIONS UNDER AGE I DALHOUSIE
2021_MES_461784_1
8798/2021-22/E8
Open Tender
Civil Works
Item Rate
180 days
AGE(I) Dalhousie
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Dalhousie
₹16,000
Yes
AGE(I) Dalhousie
29 Sept 2021
29 Jul 2021
23 Aug 2021
29 Jul 2021
21 Aug 2021
13 Aug 2021
29 Jul 2021 - 9 Aug 2021
9 Aug 2021
Amount
Demolition of cement concrete (unreinforced) of any description not other specifically provided for etc and removal of debris to a distance not exc 50 mts and depositing where directed at a level n exc. 1.5 m above the starting point.
Demolition of wall and ceiling boards any thickness of any description including cover fillets complete all as specified and directed.
Dismantling timber scantling 40sqcm and over in section in any position in framed work all as specified.
Material and Labour for second class hard-wood (Hollock), timber framed and fixed, clean sawn, in scantlings, complete, all as specified and as directed by the Engineer-in-Charge.
M&L cover fillets of standard hard board 6mm thick, 40mm wide and fixing with screw etc, complete, all as specified and as directed by the Engineer-in-Charge.
Preparation of new wood and wood based surfaces of any description n exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Preparation of old painted wood or wooden based surfaces by rubbing with abrasive paper etc of any description over 10cm width or girth and applying one coat of synthetic enamel paint over a coat of primer (pink primer), complete all as specified.
Providing and fixing tiled false ceiling of of size 595x595 mm in true horizontal level suspended on inter locking Gyproc metal grid of hot dipped galvanized steel sections(galvanized @ 120 gms /sqm, both side inclusive) consisting of 3600mm long main & quot, T", runner size 24x32mm and0.30mm thick, 1200mm long cross & quot;T" of size 24x25mm and 0.30mm thick,600mmsecondary cross "T" of size 24x25mm and 0.30mm thick and PPGI wall angle of size 24x24mm and 0.4mm thick. Bottom exposed capping of width 24 mm of all T-sections shall be of 0.25mm thick PPGI .Wall angle is fixed along the perimeters of the ceiling to Walls, partitions or columns etc with rawl plugs and wooden screws at 300mm centers. Main"T" runners are then suspended from ceiling using GI slotted cleats of size27 x 37 x 25 x1.6 mm fixed to ceiling with 8 mm dia and 45mm long dash fasteners, 4mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at max1200mm center to center along main T, and not more than 150mm from spliced joints. The last hanger at the end of each main runner should not be greater than 600mm from the adjacent =wall. Then 1200mm long cross & quot;T & quot; is interlocked between the main "T & quot; at600mm center to center to form a grid of 1200x600 mm and then secondary cross “T & quot; of length 600mm is then interlocked at middle of the 1200x600mm grid to form grids of 600x600mm. Cross Tees at the ends having length more than 600mm are to be supported independently. Finally Gyproc 8mm thick tiles of size 595x595 having foil on back side & PVC paper on front side wrapped around edges to be placed in grid. Make :-Lafarge, Boral Gypsum Board Pvt Ltd, Shri Nepal Board Ltd, Aerolite Ceiling System Pvt, Hilux, Armstrong, Dexune or equivalent.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground
S & F in Repairs Galvanized, 2 strand, steel barbed wire 2.24 mm dia., barbed with 2 mm dia., barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel pins etc., as directed.
Restraining & resecuring existing barbed wire of any type incl making good staples etc any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc (each line wire to be measured) complete all as specified.
Excavating in post holes (or similar holes) each n.exc 0.5 Cum , getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layer n.exc 25 cm, watering, and removing surplus soil to a distance n.exc 50 mtr and making good surfaces in soft/loose soil.
Cement concrete type C-2 1:3:6 (Using 40mm graded stone aggt) in foundation filling and mass concrete.
Mild steel work as post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc; and similar works conforming to Fe-290 Gde E-165 complete all as specified.
Preparation of new/old steel surfacesurfaces of any description, otherwise described, over 10 cm width or girth and applying two coat of Synthetic enamel paint (Ordinary tint) over a coat of pink primer.
Dismantling of fencing wire mesh any type
Supply only Chain link fencing 3.8 mm mm dia galvanized PVC coating wire (50x50) mm mesh made upto matress lapped wire and laid on position / fixed on poles complete.
Fixing only chain link fencing including line wires, any mesh , size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire.
Dismantling Plain or corrugated teel sheeting any gauge, thickness, including nainital or similar pattern roof coverings.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles.
Brick work with sub class "B" bricks straight or curved on plan exceeding 6 metre mean radius in cement mortar 1:6, all as specified .
75 mm thick plain cement concrete 1:3:6, type C2, using 20 mm graded stone aggregate) as in plinth protection, path etc laid in alternate bays not exc 3 m in length, and finishing the surface even and fair without using extra cement all as specified and directed.
75 mm thick PCC 1:4:8, type D2 as in subbase using 40 mm graded aggregate .
40 mm thick plain cement concrete 1:2:4. type B-1 (20mm graded aggregate) as in floor including finishing top even & smooth without using extra cement.
Taking down cement plaster of any description on brick walls/ ceiling etc including racking out joints, hacking for key, scrubbing down with water complete.
M & L for 15 mm thick rendering in CM 1:6 on brick work or concrete/ stone surfaces including finishing plaster surface even and smooth without using extra cement all as specified and directed.
M & L for 15 mm thick rendering in CM 1:4 on brick or concrete/ Stone surface including finishing plaster surface even and smooth without using extra cement all as specified and directed.
Preparation of newly plastered surface of walls and applying three coats of white wash complete all as directed.
Preparation of newly plastered wall surface and applying two coats of cement base paint complete all as directed.
Preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of alkali resistant & primer complete all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding, removing serviceable tiles to store and rubbish off the premises complete all as specified.
M & L for non - skid coloured ceramic tiles 6 to 7 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors and including 15mm thick screed bed or bedding layer of CM (1:6) etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match.
M & L Coloured glazed ceramic tiles of size 450 X 350 X 7 mm thick as in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match,and including 10mm thick screed bed or bedding layer of CM (1:4) complete all as specified and directed.
Chequered cement concrete tiles 30 cm x 30cm x 25 mm thick, set jointed and pointed in neat cement slurry with grey cement and no pigment in floors over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade (with grey cement and pigment) complete all as specified and directed
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with tinned tacks, or stainless steel wire staples including etc complete all as specified and
Hacking out old broken glass (any thickness) and size from metal frame glazed with putty or fixed with wooden beads and removal of debris to a distance n.exc 100 mtr and depositing where directed.
3 mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc 0.5 Sqm in each pane complete all as directed.
Taking down carefully existing copper/aluminium point wiring of any type (light/fan/socket or power) complete fixture and fittings such as switches ,ceiling rose, regulators,sockets etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per sch of credit) and making good disturbed surfaces of wall, floor, ceiling etc.
Point wiring in replacement with copper conductor cable multistrand, PVC sheathed 1.5 Sqmm size FRLS for one light point / fan point or bell point controlled by one switch including one run of 1.5 Sqmm multistrand FRLS PVC sheathed copper conductor cable for earth continuity in and including PVC casing and capping of approved size,make and quality ISI marked, including providing suitable size of copper lugs and all other required accessories as specified in Preamble 1(a) to (q) of section 19 of SSR Part-II under heading 'Point wiring' fixed on walls/ceiling including sunk cast iron boxes concealing on wall for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified and directed. Make of wire :- Havells / Polycab/ finolex / Plaza/Grandlay
All as per Srl item No 42 here in before but for one 5 amps socket out let on same board.
All as per Srl item No 42 here in before but for one 5 amps socket out let on independent board,
All as per item No 42 above but for power point 3 pin switch socket 15 Amp with PVC insulated copper conductor cable multistrand unsheathed 2.5 Sqmm FRLS on independent board including one run of 1.5 Sqmm multistrand FRLS PVC sheathed copper conductor cable for earth continuity in and including PVC casing and capping of appropriate size makes and best quality ISI marked, including CI/Pressed steel sunk box and providing suitable size of copper lugs and all other required accessories as specified in preamble 1(a) to (q) of Section-19 of SSR Part-II under heading "Point wiring" fixed on wall including sunk cast iron boxes concealing on wall for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified and as directed. Make of wire :- Havells / Polycab/ finolex / Plaza/Grandlay
Supply & Fixing in replacement Switch piano, flush button, single pole one way 5 amps. Make :-Anchor/Cona/Plaza/SSK
Supply & Fixing in replacement Socket outlet 2 in 1, 3 pin, 5 amps flush type. Make :-Anchor/Cona/Plaza/SSK
Supply & Fixing in replacement Switch piano, flush button, 15 amps single pole one way.Make :-Anchor/Cona/Plaza/SSK
Supply & Fixing in replacement Socket outlet 2 in 1,3 pin 5 and 15 amps flush type.Make :-Anchor/Cona/Plaza/SSK
Supply and fix in replacement ceiling rose 65X50 mm three terminals with back plate complete all as specified. Make :- Anchor / Cona / Plaza / SSK
Supply and fixing in replacement lamp holder PVC/Polycarbonate type with back plate for batten/angle fitting. Make :- Anchor / Cona / Plaza / SSK
S & F in replacement of unserviceable Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder includingLED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete. Make- Crompton/Havells/Wipro
Supply and fixing in replacement LED street light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make- Havells/Wipro/Crompton
Supply & Fixing in replacement Sheet metal enclosure for DB,s, double door (when MCB,s to be used) single pole & neutral 4 way with 200 amps rated bus bar 240 volts with fixing arrangements. Make- C&S/Havells/Indoasian/Legrand
Supply and fixing inreplacement MCB single pole and neutral 6 to 32 Amps, 240 volts complete all as specified and directed. Make :- C&S/Havells/Indoasian/Legrand
Supply and fixing inreplacement MCB single pole 6 to 32 Amps, 240 volts all as specified and directed. Make:- C&S/Havells/Indoasian/Legrand
M&L for PCC Type B1 1:2:4 (using 20mm graded stone aggregate) in landings, cover slabs (for man holesetc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces all as specified
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, ncluding cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M/s Shakti Electric Works
m/S Varun Gupta
malghotra construction co
Pathania Builders
Roshan Lal Thakur
M/s. Rishav Sood
M/S Ajay Kumar Mahajan
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .