| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.2 LAccepted-AOC FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L1 | Accepted-AOC OK | |
| 2 | L2₹92.8 L+₹13.5 L (17.1%)Rejected-AOC H 8 NO 15 SCHOOL KE SAMNE OUTSIDE JASSUSAR GATE BIKANER | BIKANER | BIKANER | RAJASTHAN | L2 | Rejected-AOC OK | |
| 3 | L3₹94.9 L+₹15.6 L (19.7%)Rejected-AOC | L3 | Rejected-AOC OK | |
| 4 | L4₹95.5 L+₹16.3 L (20.5%)Rejected-AOC GALI BAWARI WALI NOHARIA BAZAAR SIRSA 125055 HARYANA | SIRSA | HARYANA | 125055 | L4 | Rejected-AOC OK | |
| 5 | L5₹96.4 L+₹17.2 L (21.7%)Rejected-AOC | L5 | Rejected-AOC OK |
Tender Value
₹1 Cr
EMD Value
₹1.8 L
Closing Date
29 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF Bhisiana
HQ CWE AF BHISIANA
CWE(BHI)/SIR-27/2022-23
2022_MES_541106_1
CWE(BHI)/SIR-27/2022-23
Open Tender
Civil Works
Item Rate
180 days
AF Sirsa
AS PER COVER 1
6 documents required · 6 mandatory
₹1,000
Yes
GE AF Sirsa
₹1.8 L
Yes
29 Sept 2022
26 Jul 2022
31 Aug 2022
26 Jul 2022
29 Aug 2022
17 Aug 2022
26 Jul 2022 - 2 Aug 2022
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out, complete all as specified and as directed.
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil, for foundations and getting out in soft loose soil, complete all as specified and as directed.
M & L for returning filling in including spreading, levelling, watering and ramming in layers not exceeding 25 cm thick with earth obtained from excavation, complete all as specified and as directed.
M & L for removal of surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed.
M & L for removal of surplus soil to a distance exceeding 250 mtrs but not exceeding 500 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed.
M & L for removal of surplus soil to a distance exceeding 1.50 KM but not exceeding 5 KM and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed.
M & L Cement concrete 1:4:8 type D2 using 40mm graded aggregate as in foundations, filling and mass concrete, complete all as specified and as directed.
M&L,Reinforced cement concrete (design mix) M-25 ( 20mm graded aggregate) in foundation beams, plinth beams, bases for columns, etc, basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed.
M&L,Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L,Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter on flat rough finished surfaces of concrete,complete all as specified and as directed.
M&L,Formwork for fair finished surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and as directed.
M&L,Formwork on curved surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and as directed.
S & F steel work for in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS 11611979 grade St-240, complete all as specified and as directed.
S& F plates (Plain or chequered) channels, Fe 410-W (Gde E-250) quality A, square cut or notched (ordinary and counter sunk) forming holes without any attachment, complete all as specified and as directed.
M & L for mild steel bolts, purpose made with hexagonal or square head on end and screwed the other or screwed both ends exc 20 mm dia but n exc 25 mm dia each screwed end to be fitted with washers and one end hexagonal or square but n exc 30 cm long, complete all as specified and as directed.
S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5 mm thick coloured having pitch 190 mm, depth 29 mm and tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with aluminium self tapping screwed of size 50/75 mm and aluminium washers of suitable size, complete all as specified and as directed.
Material and labour for preparation of new steel surfaces of any description not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint of approved colour / tint over a coat of red oxide primer exposed to view surfaces, complete all as specified and as directed.
Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 15 cm, complete all as specified and as directed.
M&L,150 mm thick, Cement concrete type B- 2, 1:4:8 (40mm graded aggregate),as in sub base,complete all as specified and as directed.
Brickwork with sub class ‘B’ bricks with cement mortar 1:6, straight or curved on plan exc 6m mean radius built in, complete all as specified and as directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in 1:4 cement mortar, complete all as specified and as directed.
Reinforced cement concrete M-25 (design mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like type B-1 (20mm graded aggregate),complete all as specified and as directed.
M&L,Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter on flat rough finished surfaces of concrete,complete all as specified and as directed.
M&L Finishing Surfaces of Concrete Roads, Pavements, etc. by brooming, complete all as specified and as directed.
M&L Forming 12mm thick Expansion Joint by using diamond cutter after setting of PCC as directed, filled with pre-formed bitumens filler and top 30mm primed and sealed with sealing complound grade 'A' for 150mm thick Concrete Slab, complete all as specified and as directed.
Forming Contraction (Dummy) joints 65 mm deep x 10mm wide,filled with sealing compound, filled with pre-formed bitumens filler and top 30mm primed and sealed with sealing complound grade 'A' for 150mm thick Concrete Slab, complete all as specified and as directed.
M&L Forming Construction joint 10mm wide by full depth by cutter after setting of PCC as directed, filled with pre-formed bitumens filler and top 30mm primed and sealed with sealing complound grade 'A' for 150mm thick Concrete Slab, complete all as specified and as directed.
M&L,Reinforced concrete pipes, class NP 3 with one collar per length of pipe , complete all as specified and as directed.
M&L for Cement concrete 1:4:8 type D-2, Concrete bed to drain pipes,250mm dia, including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and as directed.
M & L for 150mm thick Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed.
M&L,Reinforced cement concrete (design mix) M-35 in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc., basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed.
M&L,Reinforced cement concrete (design mix) M-35 but as in pavements, complete all as specified and as directed.
M&L Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
S&F,Standard wall pvc pipe, schedule 40 of 10 inch nominal dia, complete all as specified and as directed.
M&L Finishing walls with Acrylic Smooth exterior paint of required shade, new work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and as directed.
Supplying, laying, jointing and testing, fixing to wall using clamps/ pole / floor or in air or passing through pipes/ducts/road/drain laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened, PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 4 core 25 Sq mm confirming to IS-7098 Part-I and its latest amendments, complete all as specified and as directed.
Supplying, laying, jointing and testing, fixing to wall using clamps/ pole / floor or in air or passing through pipes/ducts/road/drain laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened, PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 4 core 25 Sq mm confirming to IS-7098 Part-I and its latest amendments, complete all as specified and as directed.
M&L for sand cushioning to underground cable with dry sand locally available 8 CM thick before laying of the cable and 15 CM thick after laying and stretching the cable below the bricks / PCC cover, punning of sand using suitable T & P as per site condition, complete all as specified and as directed. Note :- Punned thickness of sand to be considered for measurement purpose.
Supply and laying un-reinforced pre-cast concrete cable cover confirming to IS : 5820 with minimum average breking load capacity 200 bags for unreinforced covers, class LV type 1, flat, size 250mm x 150mm x 40 mm, complete all as specified and as directed.
S & F GI pipe light grade 80 mm dia as protection to cable along the pole / across road crossing/ through culvert/ passing through ceiling/ walls with necessary clamps-02 nos (Flat iron 50 x 6 mm) with nuts and bolts for fixing on pole, complete all as specified and as directed.
S & F GI pipe light grade 40 mm dia as protection to cable along the pole / across road crossing/ through culvert/ passing through ceiling/ walls with necessary clamps-02 nos (Flat iron 50 x 6 mm) with nuts and bolts for fixing on pole, complete all as specified and as directed.
Material and labour for earth continuity conductor or main earthing lead/strip fixed to wall or burried in ground or drawn in conduit (pipe/fixed to poles) of any other suitable for loop earthing etc with GI strip of size 25 x 4mm, complete all as specified and as directed.
S&F of double door Distribution box of 4 way with 200amp bus bar, 240 volt, complete all as specified and as directed.
Supply and fixing SPN 40 to 63 Aqmp rating 240V, 10KA 'C' curv miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and directed.
Supply and fix LED Street light 35 watt, for operating voltage between 110 V to 320v system efficiency not less than 120 lumen/ watt, PF-0.95 minimum, IP66 protection 5700CCT(K), CRI between 80-85 confirming to LM79 and LM 80 standards or as per IS-16104 : 2012 and IS-16106 : 2012 for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated electronic driver circuits, low THD, PMMA grade high quality transmittance lens, epoxy powder coated Die cast Aluminium housing with LED Street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, complete all as specified and directed.
Supply and fix PVC insulated multistranded FRLS copper cable of size 1.5 sq mm in and including PVC non metallic rigid conduit 15 mm dia with necessary fittings such as elbows, sockets, tee, bends etc for connection to light fitting from junction box, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iorn strip of size 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and directed.
Removal of existing elevated AGL fittings i.e Runway Edge, any type and any wattage, complete all as specified and directed.
Dismantling and Taking out carefully Isolating transformer housing box/shallow base of existing elevated/inset lights, with all other necessory accesories like isolating transformer, secondery cable and stacking in to departmental store etc complete all as specified.
Supply, installation,testing and commissioning of Inset Runway Edge light with shallow base at 23 end by cutting the PCC manually or with the core cutting machine for suitable size shallow base and fixing with suitable compound with side cable entry and all assemblies of the fitting in order as per ICAO norms including making necessary conections with secondary lead, plug and sockets and sealing with rubber/PVC tape etc. complete as required. Note :- (i) Runway edge light make should be as per Approved make from Zonal/Command level. (ii) If any minor/major unserveceability found, contractor will liable to change entire in quoted rate. (iii) All the testing certificate pertaining to Runway light will be submitted by contractor prior to installation of lights.
Supply, installation,testing and commissioning of Transformer housing box received from item above, complete all as specified and directed.
Supply and Laying of GI earth wire, Size: 8 SWG, complete all as specified and directed.
Supply and laying of cable duct of size ID-34 mm & OD-41mm including trenching and laying of following sizes outer dia PVC pipe in the soil by excavation upto 600 mm and refilling the earth and make good including coupling, splicing, jointing of pipe etc, complete all as specified and directed.
Supply of following size outer dia. PVC pipe, Size: ID-34 mm & OD-41mm, complete all as specified and directed.
Trenching and laying of following sizes outer dia. PVC pipe in the soil by excavation up to 600 mm and refilling the earth and make good including coupling, splicing, jointing of pipe etc, complete all as specified and directed.
Supply of 1 x 6 sq.mm, 5 KV grade copper conductor XLPE insulated, polyethylene sheathed, single core, complete all as specified and directed.
Supply and laying of one number PVC insulated and PVC sheathed/XLPE runway cable upto 5KV grade in the existing pvc pipe etc, complete all as specified and directed.
Supply and fixing of Primary AFLS cable connector 5KV rating for Primary cable, complete all as specified and directed.
Supply and fixing of 6 sq.mm copper conductor AFL cables with ESNA connector i/c crimping & fixing, including making field connections of 5 KV grade, applying HT tape, complete all as specified and directed.
Supply of 1core X 4 sq.mm AFL secondary lead made out of annealed tinned copper conductor, EPR insulalted PCP sheathed,unarmoured,anti termite & anti rodent treated 600V/1100V grade cable for connection between isolating transformer and airfield light fixtures as specified in particular specification etc, complete all as specified and directed.
Supply and laying of secondary cable by Cutting of surface with kerf cutting machine of suitable size & depth for laying Secondary cable in bituminous/PQC area of runway i/c kerfing, chiseling, cleaning and refilling the groove with suitable PCC and sealant material as required and making good including primer etc, complete all as specified and directed.
Removing of OFC cable from soil by excavation ,reming and coiling of cable refiiling the excavated trench etc, complete all as specified and directed.
Supply of 24 Core, Single Mode,OS2, armoured optical Fibre cable, external rodent resistant with as per standard specification, complete all as specified and directed.
Design, manufacturing, supply, installation, testing and commissioning of outdoor type cubical distribution panel double door,weather and vermin proof, powder coated paiting,Duly fabricated with 2mm thick CRCA Sheet Steel, 3mm thick sheet steel for gland plate, Degree of Protection of Enclossure shall be IP~54.suitable for operation on 3 phase and neutral, 415 V,50 HZ AC system.Entire panel shall have a common GI earth bar of size 50mmx5mm at the rear with two number earth stud. Cable entry will be from bottom. Control Wiring should be done by FRLS PVC insulated 2.5 Sq.mm solid copper conductor cable. The feeder pillar shall consist of following swich gears, Bus Bar and other acessories complete as required and as per technical specification attached with tender document. Note :- (i) LT panel shall be CPRI approved (ii) Contractor shall submit the following test repot i.e. IP Test report and verification of short circuit withstand test report issued by CPRI in respect of LT panel (iii) Contractor shall submit drawing for approval prior to place order. Incomer (a) 63A, 4P MCCB, 25 kA, 415 V - 01 nos (b) 1 Set of 100 Amp TPN busbars of high conductivity electrolytic grade aluminium with 100% neutral size & Heat shrinkable colour coded insulation sleeves.
Outgoing (i) Power Contactor(32A,4P,3Ph,415V,50 Hz) with Auxilary contactor with 2 NO + 2 NC necessary timer(auto-manual- bypass),control MCB etc-01 Nos. (ii) Power Contactor(9A,2P,1Ph,230V,50 Hz) with Auxilary contactor with 2 NC ,necessary timer(auto-manual-bypass), control MCB etc-03 Nos (iii) MCCB of 32 Amps, 415 V, breaking capacity 25 kA(Ics=100%Icu),4 Pole, Adjustable Thermal magnetic releases-2 Nos. (iv)Rotary switch for auto & manual syastem and ON- OFF LED Indication lamp : 06 Nos. (v) 10 A, 10 kA, DP MCB - 10 nos
Note :- (i) Aircraft arresting Gears work are specialised type work and will be required more accuracy and engineering. All work should be done under the supervision of specialised person (ii) Contractor will ensure that runway lights/OFC cabling work / AFLS cable work / HT work will be done by specialised agency. (iii) Contractor will provide CPM chart and ground action line diagram, before commencement of work on ground. (iv) Transportation cost for all type store/all items shifting from store to site and vice-versa, deemed to be in quoted rate. (v) Issueing of gate passes will be sole responsibility of contractor and all workman should be double vaccinated as per GOI guidlines. (vi) Contractor further acknowledges and agrees that due to the uncertainties with respect to the pademic, cost of performance with respect to an order increase particularly as it relates to, without limitation, shipping and freight costs, department shall not be entitled to an equitable adjustment to the order price. (vii) In light of the uncertainties surroundings the impact of the COVID-19 pandemic, if any delay in the delivery of the items or delivery is delayed due to the fault of the vendors/OEM and Runway work hampers, whem penalty will be imposed as per IAFW-2249 of contract greement. (viii) Damage caused by failure of any items supplied by Vendor and than items is not under warranty or by any hardware or software not supplied by Vendor/OEM, will be sole responsibility to contractor to change entire items including in quoted rate. (ix) All materials offered and workmanship should be guaranteed against defect and malfunction for minimum period of 12 months from the date of delivery at site. Vendor will have full responsibility under this warranty, Vendor will be liable under the section ("Warranty") if the Equipment or Software has been exposed or subjected to any circumstances.
M/S GODARA CONSTRUCTION CO.
RISHABH BUILDERS
YESH BUILDERS
SARAOGI BUILDERS LIMITED
shiv shanker enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .