| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 CrAdmitted-Finance | ₹15.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹16.4 CrAdmitted-Finance | ₹16.4 Cr | L2 | Admitted-Finance |
| 3 | L3₹17.0 CrAdmitted-Finance 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA UDYAM DL 06 0048538 | NORTH WEST DELHI | DELHI | 110035 | ₹17.0 Cr | L3 | Admitted-Finance |
| 4 | L4₹17.3 CrAdmitted-Finance 11 JAMES HICKEY SARANI FORMALLY KNOWN AS DACRES LANE 2ND FLOOR KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | ₹17.3 Cr | L4 | Admitted-Finance |
| 5 | L5₹17.5 CrAdmitted-Finance | ₹17.5 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | NIRMAL SALES CORPORATION L3 | Agarwal Jagdish Construction Company Private Limited L2 | D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED L4 | CMRGS Infrastructure Projects Ltd L5 | RAVIRANJAN KUMAR RAJA L1 | SNG BUILDERS AND ENGINEERS L7 | Jasvit Constructions Private Limited L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SCHEDULE "A" Part-I (Building/Structures) (To be quoted by the tenderer) | ||||||||||
| 2.00 | Item No 01 : Design and construction of OPD COMPLEX ALONGWITH DEPARTMENT OF EMERGENCY AND TRAUMA CARE complete all as specified in soil bearing capacity report, design basis report, schedule of finishes, drawings and tender documents. | 1 | Lump sum | 9,85,22,750 ₹9.9 Cr | 9,68,00,000 ₹9.7 Cr | 8,84,00,000 ₹8.8 Cr | 10,10,00,000 ₹10.1 Cr | 9,75,00,000 ₹9.8 Cr | 15,00,00,000 ₹15 Cr | 12,00,00,000 ₹12 Cr |
| 3.00 | Item No 02 : Design and construction of AC Plant Room complete all as specified in soil bearing capacity report, design basis report,schedule of finishes, drawings and tender documents. | 1 | Lump sum | 1,08,25,600 ₹1.1 Cr | 20,00,000 ₹20 L | 1,85,30,000 ₹1.9 Cr | 1,10,50,000 ₹1.1 Cr | 30,00,000 ₹30 L | 9,00,000 ₹9 L | 10,00,000 ₹10 L |
| 4.00 | Item No 03 : Design and construction of UG Sump 100000 Gallon) complete all as specified in soil bearing capacity report, design basis report,schedule of finishes, drawings and tender documents. | 1 | Lump sum | 1,08,25,425 ₹1.1 Cr | 15,00,000 ₹15 L | 1,25,00,000 ₹1.3 Cr | 1,10,50,000 ₹1.1 Cr | 25,00,000 ₹25 L | 18,00,000 ₹18 L | 40,00,000 ₹40 L |
| 5.00 | Sch 'A' Part-II (External Water supply) Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES. | 1 | Lump sum | 1,87,200 ₹1.9 L | 2,22,128.31 ₹2.2 L | 21,872 ₹21,872 | 2,00,000 ₹2 L | 1,80,000 ₹1.8 L | 2,25,000 ₹2.3 L | 1,95,000 ₹1.9 L |
| 6.00 | Sch 'A' Part-III (External Water supply) Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES. | 1 | Lump sum | 28,35,210 ₹28.4 L | 31,79,105.31 ₹31.8 L | 31,79,105 ₹31.8 L | 28,50,000 ₹28.5 L | 26,20,000 ₹26.2 L | 3,50,000 ₹3.5 L | 30,00,000 ₹30 L |
| 7.00 | Sch 'A' Part-IV (Road Path Culvert) Lump sum price worked out by the contractor for (Road Path Culvert) as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES. | 1 | Lump sum | 6,67,525 ₹6.7 L | 7,60,652.52 ₹7.6 L | 7,28,950 ₹7.3 L | 6,75,000 ₹6.8 L | 6,50,000 ₹6.5 L | 7,00,000 ₹7 L | 6,50,000 ₹6.5 L |
| 8.00 | Sch 'A' Part-V (Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES. | 1 | Lump sum | 16,01,000 ₹16.0 L | 18,87,211.38 ₹18.9 L | 1,80,577 ₹1.8 L | 16,00,000 ₹16 L | 14,75,000 ₹14.8 L | 17,00,000 ₹17 L | 15,90,000 ₹15.9 L |
| 9.00 | Sch 'A' Part-VI (Area Drainage) Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES. | 1 | Lump sum | 39,02,100 ₹39.0 L | 52,60,760.69 ₹52.6 L | 48,39,899 ₹48.4 L | 41,25,000 ₹41.3 L | 40,00,000 ₹40 L | 45,00,000 ₹45 L | 42,00,000 ₹42 L |
| 10.00 | Sch 'A' Part-VII (Compound Wall) Lump sum price worked out by the contractor for (Compound Wall) as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES. | 1 | Lump sum | 23,41,645 ₹23.4 L | 28,19,454.94 ₹28.2 L | 27,01,977 ₹27.0 L | 25,50,000 ₹25.5 L | 25,25,000 ₹25.3 L | 27,00,000 ₹27 L | 25,00,000 ₹25 L |
Updated dates
Tender Value
₹15.0 Cr
EMD Value
₹10.7 L
Closing Date
27 Apr 2026, 6:00 pmClosed
Chief Engineer Jabalpur Zone
HQ Chief Engineer Jabalpur Zone Ridge Road Jabalpur Cantt 482001
PROVN OF OPD COMPLEX ALONGWITH DEPARTMENT OF EMERGENCY AND TRAUMA CARE AT MH GAYA
2025_MES_746714_1
753029A PROVN OF OPD COMPLEX ALONGWITH DEPARTMENT OF EMERGENCY AND TRAUMA CARE AT MH GAYA
Open Tender
Civil Works
365 days
GAYA
AS PER NIT
8 documents required · 8 mandatory
₹3,000
Yes
GE GAYA
₹10.7 L
Yes
15 May 2026
15 Jan 2026
4 May 2026
15 Feb 2026
27 Apr 2026
13 Apr 2026
Item No 01 : Design and construction of OPD COMPLEX ALONGWITH DEPARTMENT OF EMERGENCY AND TRAUMA CARE complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents.
Item No 02 : Design and construction of AC Plant Room complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents.
Item No 03 : Design and construction of UG Sump 100000 Gallon) complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents.
Sch 'A' Part-II (External Water supply) Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES.
Sch 'A' Part-III (External Water supply) Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES.
Sch 'A' Part-IV (Road Path Culvert) Lump sum price worked out by the contractor for (Road Path Culvert) as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES.
Sch 'A' Part-V (Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES.
Sch 'A' Part-VI (Area Drainage) Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES.
Sch 'A' Part-VII (Compound Wall) Lump sum price worked out by the contractor for (Compound Wall) as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES.
Sch 'A' Part-VIII (Hot water) Lump sum price worked out by the contractor for (Hot water) as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES.
Sch 'A' Part-IX (Conduit for PA system) Lump sum price worked out by the contractor for (Conduit for PA system) as listed in Schedule 'A' Part-IX against the lump sum price inserted by the MES.
Sch 'A' Part-X (Water cooler) Lump sum price worked out by the contractor for (Water cooler) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES.
Sch 'A' Part-XI (Refrigeration) Lump sum price worked out by the contractor for (Refrigerationn) as listed in Schedule 'A' Part-XI against the lump sum price inserted by the MES.
Sch 'A' Part-XII (Fire detector system/ alarm Sysem) Lump sum price worked out by the contractor for (Fire detector system/ alarm Sysem) as listed in Schedule 'A' Part-XII against the lump sum price inserted by the MES.
Sch 'A' Part-XIII (Fire Fighting) Lump sum price worked out by the contractor for (Fire Fighting) as listed in Schedule 'A' Part-XIII against the lump sum price inserted by the MES.
Sch 'A' Part-XIV (Site Clearance and development) Lump sum price worked out by the contractor for (Site Clearance and development) as listed in Schedule 'A' Part-XIV against the lump sum price inserted by the MES.
Item No 06 : All as per description of item No. 2.1 but for second year after expiry of defects liability period.
Item No 07 : All as per description of item No. 2.1 but for third year after expiry of defects liability period.
Item No 08 : M & L TV socket outlet suitable for co axialcable one module complete all as specified and directed by engg-in-charge.
Item No 09 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 2 KVA complete with alla auxillaries required for fully fintional, all as specified.
Item No 10 : Supply, laying, jointing and testing of ductile iron pressure pipe with socket & spigot ends having ISI stamping marking confirming to IS:8329/2000 in standard length of 5.50 - 6.00 meter of classification K-7 suitable for and including push on rubber tyton (gasket D-jointing) with cement mortar lining in the pipes having 100 mm bore, including aligning the pipes inside trench as per IS:12288/1987 and testing the joints with required water pressure complete all as specified & directed. Note: (i) Cutting of pipe shall be measured and paid for separately (ii) Excavation earth works shall be measured and paid for separately.
Item No 11 : M & L for Ductille iron fitting upto 100 mm dia for Bends,Tee pieces single branch. "Y" junction, double branch, cross collars, caps and plugs, (all sockets or socket and spigot) complete all as specified and directed.
(a) 900 mm x 900 mm x 900 mm
(a) 900 mm x 900 mm x 900 mm
Item No 13 : Supply and fix refrigerator, electric driven (single phase), capacity upto to 195 Litres BEE 5 star rated complete all as specified and directed.
Item No 14 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA with digital display and smart control. Complete with all accessories required for sully funtional pluc top etc asspecified and directed
Item No 15 : Supply and erecting GI Octogonal type pole size top dia 70 mm bottom dia 135mm thicness 3mm base plate 220x220mm base platethicness 12 mm foundation bolt m16x650x4 mm (7mtr long) including foundation nut bolt as per manufacture recommedation and GI Bracket single arm for fixing of street light complete all as specified and directed.
Item No 16 : Supply & fixing of Nature switch Panel fixing for street light switch of wall/pole mountable PVC enclosure conforming to IP 65 consisting of Nature switch smart SPD.Isolater,MCB ddrive for loading , and terminal blocks the enclosure comes complete with mounting brackets 16 amp 5 KW, three Phase - contactor rating 16/63 A - 01 No, MCB TPN, 01 No and MCB DP, 240volts 16 Amp 01 No Make :MS flat clamps, nuts, bolts and washers complete all as specified and directed.
Item No 17 : M & L for Earthing complete with galvanized earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground to the depth of not less than 2.25 mtr below ground level with top edge of earth plate or a depth not less than 1.50 m below ground level connected to GI strip 32 x 6mm as earth lead by means of galvanized bolts, nuts check nuts and washers and necessary excavation and earth work PCC 1:2:4 type B-1 using 20mm graded brick aggregate for earth pit RCC cover , charcoal & common salt filled in alternate layers funnel with 20mm bore light grade watering pipe, 40mm dia GI pipe light grade for protection of GI strip, wire mesh and connected to earth point including testing on all as specified and shown in electric plate No 3 of SSR Part I.
Item No 18 : M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron Wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 15 mm GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6)
Item No 19 : Supply, fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 1500mm x 1500mm x 400mm (over all dimension) made out of 3.00 mm thick CRCA sheet duly supported with MS angle iron of size 40x40x5mm vertical frame and legs with mild steel flat iron 25x5 mm in horizontal sides of the frame with front and back side openable, single hinged door/shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incoming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories complete all as specified and directed. NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item. (Location : Main LT Panel Near Prop Transformer)
Item No 20 : Supply, fabrication, installation and testing of semi concealed type LT wall mounted panel indoor type factory made CPRI Approved, water and vermin proof protection of size 1000mm x 1000mm x 300mm (over all dimension) made out of 2.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 25 x 25 x 5mm frame with front openable, single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces and connections of all outgoing / incomming cable inclusive of necessary fixing clamp as required including the following fitment accessories all complete as specified and as directed.
Item No 21 : Supply and fix Shadow less light fitting complete with emergency power unit & battery back up for min 30 minutes (3 KVA), having dome of 810 mm dia, fully counter balanced and fixed on suspension rod capable of having axial rotation of 360 degree. The unit to be suitable for operation on 230 V, single phase 50 cycles mains supply. lux level 40000 Light should be adjustable type, having technical specification should be as follow 1.source: LED, cold light,CRI (Ra) ≥ 90, 2.Colour temperature: 4000–5000 K, 3.focal distance: 0.8–1.2 m working distance(adjustable type) as per NHSRC specifications. 4.Compliance with electrical & medical device safety standards (IEC 60601-1 for safety & compatibility, ISO 13485 certified manufacturer) 5.Brightness / intensity control (step adjustment or stepless), ability to focus/adjust light field, adjustable arms (radial, angular, axial movements)
Item No 22 : Supply and fix Shadow less light fitting complete with emergency power unit & battery back up for min 30 minutes (3 KVA), having dome of 810 mm dia, fully counter balanced and fixed on suspension rod capable of having axial rotation of 360 degree. The unit to be suitable for operation on 230 V, single phase 50 cycles mains supply. lux level 40000 Light should be adjustable type, having technical specification should be as follow
Item No 23 : S & F for wiring fire alarm systems with cable of 2 core, multistranded annealed of size 1.5 sqmm armoured red colour FRLS PVC insulated copper conductor, in surface / recessed as required in MS conduit of 25mm dia, Complete with saddles and GI perforated tray of suitable size accessories required for fitting cables for fully functional as specified directed.
Item No 24 : Supply and fix MS cabinate (Approx 750 mm x600mm x450 mm ) to enclose firebrigade inletconnection fabricate from 16 gauge sheet with full front glass door and locking arrangement .
(a) 80 mm bore
(b) 100 mm bore
Item No 26 : M&L for construction of brick massonry valve pit of internal size 900 mm x 900mm x 900 mm including necessary excavation and earth work in soft/loose soil , brick work , plastering, white wash , PCC coping, MS frame mde out of angle iron of size 40 mmx 40 mmx 6 mm , MS sheet cover of 3 mm thick fixed to angle ireon frame by means of hinges welded to frame and painting with 2 coats of synhetic ennameled paint over a coat of red oxide primer on steel surfaces and gruoting the frame in PCC 1:2:4 type B1 including handle and locking arrangement with one number 50 mm dia brass pad lock, complete all as specified and directed by Engineer in charge. NOTE :-1. Brick wall shall be 23 cm thick built in cement mortor 1:4 2. Internal plaster shall be 15 mm thick in cement mortor 1:4 and external plaster up to 450 mm from top shall be 20 mm thick in CM.
Item No 27 : Supply install,testing and commissioning LT panel indoor type, dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-54) double shutter gears front and rear frame work and 16 SWG thick MS sheet duly painted with powder coated over two coats of redoxide primer and made of 40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 300 amps capacity Copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:-
Item No 28 : Supply install,testing and commissioning star delta starter of capacity 20 HP comparising of single phase prevantor, TNC sitch for auto manual operation and fixing arrangement on wall.
Item No 29 : Supply only of fire exingusiser ISI marked CO2 type fire Existinguiser 4.5 KG capacity confirming to IS : 15683:2006 (old IS : 2878) made from seamless cylinder confirming to IS : 7285 duly aproved by chief controller of explosive , Nagpur fitted with ISI Marked Controlled valve confirming to IS 3224, hight pressure 1mtr long discharge hose and hom complete with intitail gas charged with carrying handle and wall mounting bracket, sutaible for operating between 30 degree centngrated to + 55 centigarte , Fire Rating Class-138.
Item No 30 : Supply only stored pressure fire exinguisher ISI Marked Powder type Fire Exingusher 4 KG Capacity suitable for Class A,B, C fir consisting with discharge hose and nosle of welded cylinder , squeeze liver discharge valve fitted with pressure indicating guage, internal discharge tube, discharge nosle, suspension bracket confirming to IS: 15683: 2016 duly charged with ISI Maked Ammonium phosphate base ABC powder confirming to IS : 14609 and pressized with Nitrogen Gas , suitable for opersting between 30 degree centigate to +55 digree centrigrate, Fire Rating Class- 1A & 13B.
Item No 31 : Supply of fire bucket iron red colour 10 L capacity for dry sand stored type ISI Marked IS : 2546 : 2006, complete all as specified and as directed.
Item No 32 : Supply only of Fire Exitingusher Mechanical Foam type ISI Marked Foam (AFFF) type fire exinguisher 9 L capacity fitted with forged brass squeeze liver discharge valve confirming to IS :15683 : 2006 complete with intial refile consisting of of ISI Marked CO Gas Cargtridge of 60 Gms Capacity confirming to IS 4947 and ISI Marked AFFF confirming to IS 4989 suitable for operating between + 50 degree centrigrate, fir rating Class 3A an 34.
Item No 33 : Design, supply, install, testing and commissioning of copper pipes (degassed, medical - grade), Brazing with silver alloy (no flux, per standards) medicinal gas pipe line network with connected valves, Pressure regulators and filters, necessary pumps / motors and connected items, Medicinal gases comprise of Oxygen, suction and compressed air etc. Pipe line network is to be laid in treatment room, injection room, recovery room and minor OT of trauma care centre in the scale of 1 per room and connected them to the manifold room to previded sufficient medicinal gas supply.
Note:1- (I) Design of energy efficient central air conditioning plant based on inside & outside conditions inside conditions as per given data sheet attached in PS. The design shall meet relevant ASHRAE/ISHRAE norms and code requirements and should as per latest IS practices. It should included the followings:- (a) Data based heat load calculations for all weather seasons (b) Duct drawing showing different sizes of ducts air flow details, incl fire dampers and air dampers. (c) Chiller water piping / condenser water piping etc drawings including valves, vents,strainer, drains etc.
(d) Layout schematic line diagram of LT control panel suitable for the plant showing all the details such as main incoming, outgoing and their type, capacities, qty, alongwith connected measuring instrument/meters, indication lamp, starters, MCB/MCCB/ isolator literature of various components. (e) Specification/description of equpeiment and other materials/items with technical literature of various components. (f) Line plan of plant AHU showing various eqpts/items with dimensions of various qpts/items with specific working clearances between eqpts to eqpts and from walls, after due consideration of existing doors and windows.
(g) Schedule of item/description of equipment of all items with accounting unit. Qty and particular specification etc. (h) Full description of item/eqpt of schedule as per recommended brands/makes in the Tender.(i) Inside design conditions are required to be maintained irrespective of minor variations in outside conditions throughout the year as per desired conditions as per PS data sheet. (j) Contractor will submit detailed Qty with line plan which shows the all type of valves, pumps, pipe lines, Chiller AHU, Cooling Tower, Expansion tank etc. Note2: (a) Contractor should submit 2 Nos CD showing detailed design with description/specfification complete alongwith heat load calculation (For summer, winter & monsoon design, drawings, bill of quantities and four Nos hard copies. (b) Outside design conditons at Jabalpur can be obtained from concerned metrological authorities.
(c) Contractor will develop the soft copy of all the drawings required for the work on the basis of hard copy/line plan of the project. (d) Design folder duly incorporating above design details, layout plans and specifications incl BOQ of the items shall be submitted by the contractor duly bound 3 hard copies and CDs after vetting from HT/NIT/ any Govt Engineering College for the acceptance by the Rep of accepting officer before execution. (e) The work of Air conditoning shall be carried out by a specialist agency having past experience. (f) Noise level (Sound pressure) should not exceed the permissible limts. (g) Testing includes phase-1 24 Hrs continuous after completing the main work and phase-II 72 Hrs continuous for all three seasons after isssuing completion of Phase- I by the IEM (h) Any modification/alteration done for ducting and piping in the building, the Contractor shall make good the damage done for the same.
Please Enable Macros to View BoQ information
Schedule 'A' Part II
(External Water supply)
Supply and laying pipe Galavnized steel water tubing in trenched medium grade ISI marked including fittings such as bends,elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc fixing complete with clips, wall hooks, wooden plugs or laying in trenched etc complete for dia 40 mm sized. complete all as specified and directed. note:- the rates also include cutting through walls, floors,etc and their making good.
All as per item No. 01 here-in before but for dia 25 mm sized
S & F Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixing as well make it leak proof complete for following size:-
(a) 40 mm bore
(b) 25 mm bore
S&F cast iron sluice valve of size 100mm bore, class PN 1.6 heavy duty flanged ends with brass spindle, cast iron wheel for operation confirming to IS:14846:2000 including flanged joint on both side with rubber gasket, nut, bolts and washer complete.
M & L for cutting Cast iron pipe in position for inserting of new tees branches etc in 100 mm bore of pipe complete all as specified
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation etc or for laying pipe lines and getting out as in hard/dense soil complete all as specified and directed.
Returning filling in including spreading leveling, watering and well ramming in layer not exceeding 25 cm in hard/dense soil, complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M & L for PCC 1:3:6 type C-1 using 20mm graded stone aggregate for to support the pipe line etc, including necessary form work complete all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part III
(External Electric supply)
Supply, installation, testing and commissioning of 400 KVA Distribution Transformer, copper wound, stepdown, outdoor type complete with standard fittings HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapping, oil immeresed naturally cooled with externally cooling tubes laminated core type delta connected on primary HV side and star connected on secondary LV side in accordance with vector symbol DY-11 (vector group 4) with brought on secondary LV side for earthing and having tapping on HTside upto +7.5% in step of +2.5% and impedence 4.5%. The transformer shall be complete with standard fittings and accessories like conservator tank, explosion vent, air breather, thermometer & in/out gate valves etc PCC Foundation for Transformer as per manufacturer instruction/drawing complete all as specified and confirming to IS:1180 or latest IS specification for high energy efficiency (minimum BEE energy efficiency level-III or higher) and manufacturer shall hold license/certificate from BIS to this effect.
Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22. Including Painting to steel tubular poles with one coat of alumunium red oxide primer and two coat of alumunium painting. The rates also include drilling of holes in steel tubular poles and provision of precast holes in PCC poles for fixing 'D' iron, clamps and hooks for continuous G.I. earth wire etc. to the required size and number.
supply and fix HT 11 KV, out door type gang operated air-break switch with drought out fuse combination suitable for vertical mounting fixed type complete with 12 insulators of rating upto 200 Amps complete including locking arrangements with handle of suitable size of gi pipe all as specified and as directed.
Supply and Fixing Lightening arrestors expulsion type complete with all fittings, transmission class, discharge capacity 30 Kilo Amps 11 kv complete all as specified and as directed. Note:-Contractor should submit the following test reports from manufacturer as per In IS: 3070-1965,
M&L for cross arms, bracing supports, clamps back plates angles fabricated from the structural steel section including bolts, nuts, washers, welding, bending, drilling holes for bolts, bent to any required shape of size as indicated or directed, inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete all as specified and directed.
Supply,laying, commissioning and testing or passing through pipe, XLPE insulated, screened, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 11000 volts grade in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 95 sqmm 3 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed.
Supply,laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 400 sqmm 3.5 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed.
All as per above item here-in before but for cable of size 3.5 core 185 sqmm.
All as per above item here-in before but for cable of size 3.5 core 150 sqmm.
All as per above item here-in before but for cable of size 3.5 core 50 sqmm.
All as per above item here-in before but for cable of size 4 core 16 sqmm.
All as per above item here-in before but for cable of size 4 core 10 sqmm.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for laying of pipe, cable, foundation of electric pole etc and getting out in soft/loose soil, complete all as specified.
.-ditto as above but exceeding more than 1.5 m in depth
Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site.
Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm.
Supply and laying for brick of common burnt clay, sub class 'B' old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other complete all as specified and directed. Brick size-0.23x0.15x0.7 note :-all measurement in meter
M &l for PCC 1:4:8 TYPE D-2 using 40 mm graded broken stone aggregate as in mass concrete in foundations etc . complete all as specified and directed.
Material and labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for coping around the pole strut above ground level and filling in depth of poles. including neccassory form work and finishing the surface fair and even without using extra cement all as directed and specified.
M&L for PCC 1:2:4 type B-2 using 20 mm graded broken stone aggregate as in mass concrete in foundations of stay and grouting of Lt panel, filling of road cutting, making coping around steel poles, etc complete all as specified and directed .
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply,laying,galvanised steel tubing light grade complete with all fitting & clamps of size 40 mm dia for cable protection along with pole across road etc. Complete with clamp and bolting all as specified and directed by Engr-in-Charge.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part IV
(Road Path Culvert)
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed.
Removing excavated material n.exc 50 M and depositing where directed at a level n.exc 1.5 M above from starting point complete all as specified and directed.
M&L hard core of gauge 63mm but n.exc 100mm deposited spread and levelled in layers not exc 15cm thick watered and rolled/rammed to a true surface of broken stone or boulders complete all as specified and directed.
M & L 100 mm thick cement concrete type D-2, PCC (1:4:8) (40mm graded stone aggregate) as in path/hardstanding complete all as specified and directed.
M&L rubber Moulded pre-cast concrete interlocking paver block any shape and colouring and size conforming to IS 15658-2006 of 80mm thickness M-40 grade with grey cement and no pigments all as specified and directed.
Sand filling under floors are in foundation including watering and consolidation complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band drains and channels etc and similar work incl form work complete all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part V
(Sewage Disposal)
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc 10 sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil etc complete all as specified and directed.
-Ditto- all as per item no 1 above but exc 1.5m and n. exc 3.00 mtr in depth complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
Excavating over areas exc 1.5 m but n.exc 3.00 mtr deep and getting out in soft/loose soil complete all as specified and directed.
Excavating over areas, exc 3m deep but not exd 4.5m and getting out in soft/loose soil complete all as specified and directed.
Returning, filing in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removal of excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for DWC HDPE pipes Class SN-8 laid in trenches of 150 mm internal diameter of pipe and jointed as specified complete all as specified and directed.
M&L for DWC HDPE pipes Class SN-8 laid in trenches of 100 mm internal diameter of pipe and jointed as specified complete all as specified and directed.
M&L Brick work using old size bricks with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete as in manhole/septic tank and other similar works complete all as specified and directed.
M&L Brick work using old size with sub class ‘B’ bricks in one brick thick honey comb walling, built in cement mortar 1:4 complete all as specified and directed.
M&L for rendering on brick work or concrete surface of wall 15mm thick in CM 1:4 and to be finished even and fair with out using extra cement complete complete all as specified and directed.
Supply only Liquid water proofing compound complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, drains and channels etc and similar work incl form work complete all as specified and directed.
M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in cover slab (for manholes etc) and similar work incl form work and set in CM 1:6 complete all as specified and directed.
M&L for Mild Steel TMT bar 10 mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with & incl Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Mild Steel TMT bar 10 mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with & incl Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200 mm thick for rough finished flat surface of concrete complete all as specified and directed.
M&L for RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in slab supported on wall, beam and column in floors, roofs, landings and similar work complete all as specified and directed.
M & L for Plain Cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in mass concrete or filling in foundations complete all as specified and directed.
M & L for Plain Cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part VI
(Area Drainage)
Excavation in trenches n exc 1.5m wide n exc 1.5m depth; for fdn, etc. or for shafts, wells, cesspits, manholes etc. and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
M & L for PCC type C2 1:3:6 using 40mm graded aggregate stone agg as in drain in foundation filling and mass concrete complete all as specified and directed.
M & L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:4 as in wall of drain complete all as specified and directed.
M & L for rendering 10mm thick on fair face of brick wall in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M & L for PCC type B1, 1:2:4 (20mm graded aggregate) as in coping on brick drains incl weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M & L for removing excavated material n exc 50m and depositing where directed at a leve n exc 1.5m above the starting point complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and ramming in layers not exc 25cm complete all as specified and directed.
M & L for extra for forming fair finished drain or channel 30cm inner girth using extra cement incl forms moulds mitered /stopped ends etc complete all as specified and directed.
M&L 300 mm dia RCC Hume pipe CL NP2 laid and jointed complete with collars complete all as specified and directed.
M& L for RCC design Mix (M-25)for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete using 20mm graded stone agregate complete all as specified and directed.
M& L for RCC design Mix (M-25) for Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses using 20mm graded stone agregate complete all as specified and directed.
M& L for RCC design Mix (M-25) for Cover slab,r Slabs supported on walls,beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like using 20mm graded stone agregate complete all as specified and directed.
M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5mm dia and over upto and including 8mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Form work to sides of rough finished flat concrete surfaces of foundations, footing, bases of columns,raft and raft beams,sides of soffits (if any)of foundation and plinth beam and similar work vertical or to batter complete all as specified and directed.
Formwork to sides of rough finished flat concrete surfaces of walls,retaining walls, abutments,parapets and staircase railings and similar work including attached pillasters, buttresses etc.vertical or to batter complete all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part VII
(Compound Wall)
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point of soils complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and as directed.
M & L for RCC M-25 Design Mix (using 20 mm graded stone aggregate) as in foundations, incl rafts, footings, foundation beams plinth beams; bases for columns basement slabs, under-reamedpiles and mass concrete complete all as spfd & directed. (Note :- Reinforcement shell be measured ane paid separately under respective item)
M & L for RCC M-25 Design Mix (using 20 mm graded stone aggregate) as in columns, pillars, piers, posps, struts and coping complete all as spfd & directed.(Note :- Reinforcement shell be measured ane paid separately under respective item)
M & L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams;and similar work vertical or to batter complete.
M&L Formwork to sides of pillars,posts, struts, piers, columns and stanchions all as specified and directed
M & L as in repair providing precast cement concrete louvers and jallies 35mm thick solid including all moulding incl frame of pcc (1:2:4) type B0 (12.5mm graded aggregate) crushed stone & set in CM 1:4 complete all as specified and directed.
M & L brick work with flyash bricks, straight or curved on plan exc 6 m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L rendering 15mm thick on brick wall or concrete surface in cement mortar (1:4) finished even and smooth with using extra cement complete all as specified and directed.
M & L for mild steel TMT bars 6 to 8 mm dia and over cut to lengh bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia as in stirrups complete all as specified and directed.
M & L mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips TMT bars complete all as specified and directed.
S&F for framed work such gates, guard bards including pintle hinge , stops, hand made sliding bolt etc with ends of bar should and /or reveted or forged into spikes, confirming to Fe 290 grade E-165 as specified and directed
M&L for prepration of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of white cement primer complete all as specified and directed.
M&L for prepration of surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red-oxide primer on new steel surfaces all as specifed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part VIII
(Hot water)
Supply and fix adn testing electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe f stainless steel,and plug top for connection, all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part IX
(Conduit for PA system)
S & F Rigid non-metallic PVC conduit 20 MM bore inclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. Complete all as specified and directed.
S & F junction boxes (1 to 4 way) PVC complete all as specified and directed.
S & F modular Metal box 1 module complete with cutting and fixing well levelling with exisiting wall/structure all as specified and directed by engg-in-charge.
S & F modular White cover plate with frame, 1 module complete with cutting and fixing well levelling with exisiting wall/structure as specified and directed by engg-in-charge.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part X
(Water cooler )
Supply and installed water cooler,fully stainless steel, Electric driven, (single phase 230 volts) having approx storage capacity of 80 Litres and nominal cooling capacity of 40 Litres per hour complete with tapconnetion,electric connetion, etc and all accessories required for fully funtional, all as specified.
Supply and fixing bottled water dispenser, having option of dispensing normal, hot and cold water with cooling capacity 3 ltrs/hr and tank capacity of 3.4 ltrs, heating capacity 6 ltrs/hr and tank capacity 1.6 ltrs, working in R - 134a refrigerant. With stand and plug top all accessories and auxillaries required for fully funtional and operation as specified an directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part XI
(Refrigeration)
Supply and fix and testing Deep freezer Metal top of 320 litre capacity having single door complete with its plug top and auxillaries required for fully funtional all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part XII
(Fire detector system/ alarm Sysem)
S & F for wiring for circuit / sub main wiring alongwith earth wire with the 2x4 sqmm size of FR PVC insulated copper conductor, single core in surface / recessed as required in MS conduit of 25mm dia including 1x4 sqmm continuous PVC insulated earth conductor all as specified.
S & F MCB DB, SPN 4 way with 200 Amp rated bus bar, 240 Volt double door complete all as specified.
S & F isolator DP 40 Amps 10 KA 230 volt 50 Hz complete.
S & F MCB SPN 10 Amp 10 KA 'C' curve complete.
S & F for detector complying with & type cetified to EN-45 addressable type multisensor detector with heat and smoke combination / optica with base with self built intelligence as per IS: 11360.
S & F testing & commissioning of micro-processer addresaable type with digital display fire control panel with four loop of capacity for 99 Detector & 99 Module upto 200 detector & modules fitting with autoatic battery charger including maint free battery, including lamp with all connected accessories complete as directed.
S & F including testing, commisioning of manual call point addressable, resettable type complete all as specified..
S & F including testing, commisioning of electronic sounder cum sounder addressable type complete all as specified..
S & F fire alarm sounders/ sirens electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 105m with sound out put variation of + 5 DB upto 1500 mtr range complete all as specified.
S & F Remote Indicator/ Response indicator (LED TYPE) complete all as specified.
M & L anunciating devices addressable control modulewith all accessories for fully functional of it as spechified and directed.
M & L for 100 watt amplifier complete with all accessories for fully functional of it as spechified and directed.
M & L for PA system 6watt wall mounted CD speaker complete with all accessories for fully functional of it as spechified and directed.
M & L for microphone set complete with all accessories for fully functional of it as spechified and directed.
M & L for console complete as spechified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part XIII
(Fire Fighting)
Supply, Installation , Testing & Commissioning of Single headed ,Gun metal ISI marked hydrant landing value with 80mm dia flanged intel and 63mm dia instantaneous type female outlet complete with Gun Metal cap and G.I. chain twist release type plug and all accessories as per 13:5290-1983 complete all as specified and directed.
Supply, Installation , Testing & Commissioning of double headed ,Gun Metal ISI marked hydrant landing value with 80mm dia flanged intel and 63mm dia instantaneous type female outlet complete with Gun Metal cap and G.I. chain twist release type plug and all accessories as per 13:5290-1983 complete all as specified and directed.
Supply, Installation Testing & Commissioning Weather proof hose cabinet from 18 guage M.S. Sheet with full glass door and locking arrangement, suitable to accommodate 2 nos. 15 M long hose and 1 No branch pipe.The cabinet shell be painted with one cost of primer and finished stove enameled "Fire Red", "Fire Hose" written on front including suitably mounted on wall including mounting arrangements as required complete all as specified and directed.
Supply, Installation Testing & Commissioning of Gun Metal 63mm dia short size branch pipes with 15 mm dia nozzle with 63mm instantaneous coupling ISI marked (IS : 903) complete all as specified and directed.
Supply, Installation Testing & Commissioning Weather proof hose cabinet from 18 guage M.S. Sheet with full glass door and locking arrangement, suitable to accommodate fire hose reel drum with 20 mm dia 30 meter hose reel .The cabinet shall be painted with one cost of primer and finished stove enameled "Fire Red", "Fire Hose" written on front including suitably mounted on wall including mounting arrangements as required complete all as specified and directed.
Supply, Installation Testing & Commissioning of First- Aid fire Hose Reel wall mounting swinging type complete with drum, bracket, 25 mm dia. Ball valve and 20 mm dia x 30 M long high pressure Hose Reel tubing as per IS:444 with Gun Metal shut-off nozzle having 5mm dia.orifice. The Hose Reel shall strictly confirm to IS : 884-1985.
Supply, Installation , Testing & Commissioning of canvas flexible hose ( RRL type-'A') ISI marked (IS:636) 63 mm dia x 15 M long complete with instantaneous type Gun Metal 63 mm dia. IS marked Male and Female ouplings ( IS:903) bound and riveted to hose pipe with Gun Metal rivets and 1.5 mm Gun Metal wire complete all as sepcified and directed.
Supply , install ,testing and commissioning Jockey pump horizontal end suction, certrifugal type confirmig to IS : 12469-1988 with CI casing, bronze impeller and stainless steel shaft including TEFC squarriel cage induction motor 2900 r.p.m, 415 V coupled and mounted on common base plate for mounting pump and febricated of suitable MS channel . including anti viberation pad of suitable size & suitable for automatic operation with non-over loading power characteristic for frequent start/stop opration 440V, 3 phase. 50Hz 70 m Head, 180 LPM discharge including suitable size copper cable 6 core ISI marked .
Supply , install ,testing and commissioning Fire pump electrically driven horizontal and suction, centrifugal type confirming to IS: 12469-1988 with CI casing, bronze impeller and stainless steel shaft including TEFC squarriel cage induction motor 2900 r.p.m, 415 V coupled and mounted on common base plate for mounting pump and febricated of suitable MS channel including antiviberation pads of suitable size and suitable for continous operation with range of opration 0% to 150 % of rated capacity for 440V, 3 phase, 50Hz 70m Head, 1620 LPM discharge. Common base plate for mounting pump fabricated of suitable MS channel as per manufacturers recommendations suitable RCC pump foundation as per manufacturers design.including suitable size copper cable 6 core ISI marked.
Supply , install ,testing and commissioning Fire pump diesel engine driven horizontal and suction, centrifugal type confirming to IS: 12469-1988 with CI casing, bronze impeller and stainless steel shaft including diesel engine of suitable B.H.P. including diesel tank and panel for auto operation including bettery charger and 12 Volts bettery mounted on common base plate febricated of suitable MS channel including antiviberation pads of suitable size and suitable for continous operation with range of opration 0% to 150 % of rated capacity for 70m Head, 1620 LPM discharge including suitable RCC pump foundation as per manufacturers design.
Supply , install ,testing and commissioning tarrace pump horizontal end suction, certrifugal type confirmig to IS : 12469-1988 with CI casing, bronze impeller and stainless steel shaft including TEFC squarriel cage induction motor 2900 r.p.m, 415 V coupled and mounted on common base plate for mounting pump and febricated of suitable MS channel . including anti viberation pad of suitable size & suitable for automatic operation with non-over loading power characteristic for frequent start/stop opration 440V, 3 phase. 50Hz 30 m Head, 450 LPM discharge including suitable size copper cable 6 core ISI marked.
Supply, Installation , Testing & Commissioning of Mild Steel ERW pipe (IS:1239 Part-I) Heay grade class "C" 80 mm nominal bore including cutting, threading, welding etc. bends,elbows reducers,clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel fire red paint of approved make and shade including all steel work complete att as specified and directed.
Supply, Installation , Testing & Commissioning of Mild Steel ERW pipe (IS:1239 Part-I) Heay grade class "C" 100 mm nominal bore including cutting, threading, welding etc. bends,elbows reducers,clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel fire red paint of approved make and shade including all steel work complete att as specified and directed.
Supply, Installation , Testing & Commissioning mild steel Pipe (IS 1239 Part-I) 150 mm bore heavy class including cutting screwing welding etc. complete with fittings : tees elbow, bends, flanges, reducers, etc including providing anti-corrosive treatment (coating & wapping) with 4mm thick tape and holiday test check as per IS: 10221 complete all as specified and directed. (coating on only ring line which is pipe laying in underground area and pipe above ground shall be painted with fire red paint )
Supply, Installation , Testing & Commissioning of Mild Steel ERW pipe (IS:1239 Part-I) Heay grade class "C" 40 mm nominal bore including cutting, threading, welding etc. bends,elbows reducers,clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel fire red paint of approved make and shade including all steel work complete att as specified and directed.
Supply, Installation , Testing & Commissioning of Mild Steel ERW pipe (IS:1239 Part-I) Heay grade class "C" 25 mm nominal bore including cutting, threading, welding etc. bends,elbows reducers,clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel fire red paint of approved make and shade including all steel work complete att as specified and directed.
supply, Installation , Testing & Commissioning of : Slim seal Butterfly valves B 190 Class (PN1.6) complete with matching flanges rubber insertion, nuts. bolts and washer etc. of following sizes:-
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
Supply, Installation Testing & Commissioning of : dual plate non-return valves ( PN 1.6) complete with matching flanges, rubber, insertion, nuts, bolts and washer etc. of following sizes :-
(a) 80 mm bore
(b) 100 mm bore
(C) 150 mm bore
supply and fix pressure gauge 100 mm dia with ball valve of pressure 25kg/Sqcm.
Supply and fix Gun metal fire brigade inlet connection (suction collecting head ) consisting of four numbers 63 mm dia instantaneous typemale coupling with built in check valve150 mm dia valve NRV and 150 mm dia flanged outlet complete with all accessories.
Supply and fix Air cushion tank (air vessel ) 200 mm dia x1000mm high with dishedtop , made of minimum 6 mm thick MS pipe /plate complete with 20 mm dia stop valve ,pressure gauge with brass stop cock ,nipple,tee,elbow and all accessories.
Valve sluice fllanged,of class 1.6 PN supplied and installed complete, size 150 mm (6") dia.
Pressure switch universal type.
Supply and fix sprinkler quick response type as per IS: 15105 /TAC guidelines 68 degree temprature rating
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised, steel strip or wire armoured, electric power cable, (heavy duty) 1100 volts grade, with stranded aluminium conductor of size 3.5 core x 150 Sqmm .
Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site.
Supply and laying for brick of common burnt clay, sub class 'B' old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other complete all as specified and directed. Brick size-0.23x0.15x0.7 note :-all measurement in meter
Excavation in trenches, n.exc 1.5m wide & n.exc 1.5m in depth for foundation & getting out in for laying of cable complete as specified. For - Soft/loose soil
Returning filling in including spreading, levelling, watering & well ramming in layer not exc 25cm complete all as specified.
Removing excavated meterial n.exc 50m & depositing where directed at a level n.exc 1.5m above the starting point
S & F GI tubing medium grade of 25 mm dia with one socket both end threaded in any length including cutting threading connection and all type of GI new fittings for laid in trenches/ wall/ ceiling/ floor all as specified and directed.
S & F stop valve of 25 mm dia complete all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part XIV
(Site Clearance and development)
Site Clearance getting out in soft/loose soil all as spd and directed.
Excavating over areas, n exc 1.5 m deep and getting out Hard/dense soil complete all as specified and directed.
Excavating over areas, exc 1.5m deep and not exc 3.0 m deep and getting out Hard/dense soil complete all as specified and directed.
M&L for Moorum filling in floors or pavings, laid in layers n exc 15cm thick in each layer, spread, levelled and rammed by 8 to 12 ton mechanical power roller including watering, transporting and depositing etc complete all as specified and directed.
Removal of excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.84 MB
1T.pdf
Tender Documents • 4.64 MB
BOQ_838338.xls
BOQ • 2.45 MB
Download all tender documents and submit your bid