| 1 | L1₹18.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹21.0 L+₹2.7 L (15.0%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹21.2 L+₹3.0 L (16.3%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹22.0 L+₹3.7 L (20.5%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹22.1 L+₹3.8 L (21.1%)Rejected-Finance BOOTH NO 119 SECTOR 9 PANCHKULA 134109 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134109 | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹48,500
Closing Date
22 Jul 2022, 6:00 pmClosed
CWE Patiala
HQ CWE, Bldg No 26, New Lal Bagh, Patiala 147001
SPECIAL REPAIR FOR REPLACEMENT OF TRANSFORMER AND CONNECTED ACCESSORIES AGAINST BER AT MIL STN NABHA UNDER GE SOUTH PATIALA
2022_MES_534754_1
8322/PAT/T-15/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Nabha
As per cover 1
6 documents required · 6 mandatory
₹500
Yes
GE South Patiala
₹48,500
Yes
20 Aug 2022
30 Jun 2022
25 Jul 2022
30 Jun 2022
22 Jul 2022
14 Jul 2022
30 Jun 2022 - 7 Jul 2022
Amount
Supply and installation of copper wound transformer step down, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapping on HT side to vary secondary voltage within limit, all as per IS : 1180 of capacity 100 KVA complete all as specified and as directed.
Supply and installation of copper wound transformer step down, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapping on HT side to vary secondary voltage within limit, all as per IS : 1180 of capacity 200 KVA complete all as specified and as directed.
Supply and fix in replacement HT 11 KV out door type gang operated air break switch suitable for horizontal or vertical mounting rotating type complete with drop out fuse having 12 insulators of rating upto 200 Amps complete all as specified and as directed.
Supply and fix in replacement Lightning arresters expulsion type complete with all fittings, Transmission class, discharge capacity 65 kilo ampr HT 11 KV 10 KA, suitable for 11000 volts station class complete all as specified and as directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried vertically in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to and including galvanised iron strip 32×6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and ( 50 mm dia GI light grade pipe for protection of GI strip) to the extent of 7.50 meters as earthing lead and connecting to the eqpt, viz transformer, L.T panel etc. including charcoal dust and salt packed all around the earth plate in the earth pit all as per electrical plate No. 3 of SSR-2009 Part-I including chamber made up of PCC 1:2:4 type B1 with M.S angle iron frame, CI Cover with provision of locking arrangement and 20 mm dia light grade GI pipe from edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement, complete including excavation and earth work in any type of soil strata and testing complete all as specified and as directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level and filled with alternate layers of charcoal and salt with 15 cm thick layer, connected to galvanised wire earth lead 4mm dia by means of bolts, nuts, check nuts and washers made of galvanised iron , 20mm bore GI pipe (Med Grade) for watering, 15 mm bore GI pipe (light grade) for protection of earth lead, including necessary earth work in any type of soil, Earth pit of PCC (1:3:6) type C1 and precast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8 mm dia TMT bar @ 150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar embedded in cover slab complete all as shown in electrical plate No. 3 of SSR Part-I, including testing on completion complete all as specified and as directed.
Supplying, Laying connecting and testing XLPE insulated, PVC sheathed, armoured HT electric power UG cable (heavy duty with stranded aluminum conductor) of size 95 Sqmm, 3 core, 11000 Volts(Earthed) grade, confirming to IS-7098 (Part-II) laid through duct/ pipe / in trench etc. with cable glands and suitable size of aluminium lugs including taking down old cable and cable covers etc complete all as specified and as directed. Note :- Earth work, concrete cable covers, sand cushioning and GI Pipe shall be measured and paid separately under respective item.
Supply, laying, Jointing and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 240 sqmm 3.5 core laid in trenches / on poles / walls / in ducts / passing through pipes with necessary cable lugs, bolts, nuts and washers including taking out old cable and cable covers complete all as specified and as directed. Note :- Earth work, concrete cable covers, sand cushioning and GI Pipe shall be measured and paid separately under respective item.
Supply, laying, Jointing and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 70 sqmm 3.5 core laid in trenches / on poles / walls / in ducts / passing through pipes with necessary cable lugs, bolts, nuts and washers, including taking down old unserviceable PILCA/XLPE cable and cable cover etc complete all as specified and as directed. Note :- Earth work, concrete cable covers, sand cushioning and GI Pipe shall be measured and paid separately under respective item.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation , poles struts , laying of cables and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm as in soils complete all as specified and directed.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point as in soils complete all as specified and as directed.
Sand cushioning with dry river sand in trenches for cushioning of underground cable with layer of sand 8 cm before laying of cable and 15 cm thick after laying of cable complete all as specified and as directed. NOTE: For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR Part-I.
Factory made unreinforced Precast concrete cable covers class LV type 1, flat, Size 250x150x40mm laid in trenches as protection to cables complete all as specified and as directed.
Factory made unreinforced Precast concrete cable covers class HV type 1, flat, Size 300x180x40mm laid in trenches as protection to cables complete all as specified and as directed.
GI tube light grade, 80mm bore as in cable protection pipe including all fittings complete all as specified and as directed.
GI tube light grade, 40mm bore as in cable protection pipe including all fittings complete all as specified and as directed.
PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete including dismantling / demolition the existing concrete, necessary form work if required complete all as specified and as directed.
Brick work using old size sub class 'B' brick straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
PCC 1:2:4 type B2 using 40 mm graded stone aggregate, 100 mm thick as in platform including use and waste of necessary form work, finishing the exposed surface even and smooth complete all as specified and as directed.
100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base of floor finished even and fair without using extra cement complete all as specified and as directed.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including painting two coats of aluminium paint over a coat of primer complete all as specified and as directed.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm and testing after jointing complete all as specified and as directed.
Danger notice plate of 16 mm thick mild steel sheet, vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 25x20 cm size duly written in Punjabi, English & Hindi languages complete all as specified and as directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc of size 25 x 3mm aluminium strip complete all as specified and as directed.
Cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor / indoor termination heat shrink type joint with jointing material and accessories suitable for 3.5 Core XLPE armoured / PVC aluminium conductor cable of size 185 Sqmm to 240 Sqmm complete all as specified and as directed.
R D Bansal
AR CONSTRUCTIONS
Kaul Enterprises
SHARMA ELECTRICAL ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .