Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹43.7 L+₹63,993.01 (1.48%)Rejected-Finance 60 310A 3 KHERIA MOD JAGNER ROAD AGRA 01 | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹43.9 L+₹79,039.45 (1.83%)Rejected-Finance 00 BEHIND CHARCH NAYAGOWAN LAKHERA BEHIND RAMA MANI DAIRY KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹44.0 L+₹93,537.46 (2.17%)Rejected-Finance 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹44.4 L+₹1.3 L (2.90%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹45.4 L
EMD Value
₹90,700
Closing Date
7 Feb 2024, 6:00 pmClosed
GE (East) Agra
Garrison Engineer (East) Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt-282001
ADDN/ALTN OF EXISTING BLDG, ADDN/ALTN OF BOUNDARY WALL AND ENTRANCE GATE AT SHATRUJEET SUVIDHA PARISAR, PROVN OF OVER HEAD STRUCTURE AT MAIN GATE OF AATS AND SPL REPAIR OF 320 KVA DG SET AT 509 ABW UNDER GE (EAST) AGRA
2024_MES_636507_1
9636/E8
Open Tender
Civil Works
Item Rate
180 days
AGRA (UP)
Please refer tender documents
10 documents required · 10 mandatory
₹500
GE (East) Agra
₹90,700
Yes
30 Mar 2024
10 Jan 2024
14 Feb 2024
10 Jan 2024
7 Feb 2024
24 Jan 2024
Amount
Taking down cement or cemant lime plaster of any discription on bricks or stone walls/ceiling etc including racking out joints, hacking for kay, scrubbing down with water complete all as specified and directed.
Material & labour 5 mm thick rendering in CM 1:3 concrete surfaces of ceiling etc, finished surfaced even & smooth with out using extra cement complete all as specified & directed.
M&L for 10mm thick plastering in CM 1:6 on brick surfaces of walls & finishing the surface fair & smooth complete all as specified and directed.
M&L for 15mm thick plastering in CM 1:4 with WPC on brick surfaces of walls & finishing the surface fair & smooth complete all incl water proofing compound at any height etc complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of average 2mm thick Birla putty on new plastered surfaces including preparation of surface slab complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coat of white wash over a coat on new plastered surfaces complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer etc complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connections etc complete all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 with complete fittings 20 mm outer dia on walls/ceiling or laying in floors complete all as specified and directed.
Taking up or down 20mm dia steel tubing and connections etc complete all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 with complete fittings 25 mm outer dia on walls/ceiling or laying in floors complete all as specified and directed.
S & F PVC (SWR) floor trap, plain with grating including jointing with solvent cement (Diameter of outlet 75mm), jointing to waste pipe and fixed in cement concrete 1:2: 4 (type B1) mixed with pedilite water proofing liquid @ 200ml in 50 kg cement, inlcuding taking out of old unserviceable connections etc, connecting up new and making good disturbed portion complete all as specified and directed.
Supply & fix C.P. grating 100/125 mm dia as reqd at site complete all as specified and directed.
Taking down cement plaster including ,tarfelt from old concrete roof/chajja and cleaning by picking ,sweeping and washing down with water to remove dust etc Brushing neat cement slurry with 3.0Kg of cement per Sqm and M&L for rendering 10mm thick in CM (1:4) on roof slab/chajja finished fair and smooth without using extra cement with water proofing compound @ 3% by weight of cement complete all as as specified and directed . Note : water proofing compound shall be measured and paid separately.
M& L for water proofing treatment with APP based polymeric membrane 3 mm thick (minimum) weighing 3.00 Kg per sqm reinforced with polyster non woven fabric shall be applied over and including one coat of water based bituminous emulsion primer on newly plastered surface @ 0.40 Kg / Sqm duly thermo fused by flame torch all as specified in method of application manual of the manufacturer complete all as specified and as directed.
M&L cutting out cracks to V Section in existing roofs or terracing cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 complete all as specified and directed
S&F in repair bib taps, cast copper alloy, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket or PPR pipe etc making good disturbed portion complete all as specified and directed.
Supply and fixed in repair angular valve , 15mm dia, cast copper alloy,CP fancy type with long shank and cup screwd down, high pressure ,screwed both ends for iron pipes or for unions and fixed in pipe complete all as specified and directed.
S & F PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed.
S&F in repairs 10litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flush pipe 32mm dia and PVC connections 15mm size with PTMT nuts of length 450mm inlcuding taking out of old unserviceable connections etc, connecting up new and making good disturbe portion complete all as specified and directed.
S & F health faucet (ABS body) mild steel Chcomium Plated suitable for 15mm dia pipe 1.25m long flexible tube and ABS wall hook including making connection and fixed in position for pedestal pattern WC incl. complete all as specified and drected.
S&F 500 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PVC float valve complete all as specified in SSR Part I including dismantling of existing tank and removing to store/ issued under schedule of credit complete all as specified and directed.
S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) inlcuding taking out of old lime/cement concrete bedding, unserviceable connections etc connecting up new and making good disturbe portion complete all as specified and directed.
S&F in repair vitreous china wash down water closed pan (Pedestal pattern) (excluding flushing cistern ) and flush pipe, including connection to trap and cistern and flush pipe and making good to disturbed surface of floor all fixed as in repair complete all as specified and directed.
S&F in repair plastic water closet seat cover, white/ black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinging device complete all as specified and as directed.
Taking down chowkats or frame with shutter (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed.
S&F for PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS Square tube complete all as specified and as directed.
S&F for factory made PVC door shutter 30mm thick (style) consisting of frame made out MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheets of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement complete all as specified and as directed.
S & F butt hinges 100mm long cold rolled medium weight complete all as specified and as directed.
S & F for 150mm long aluminium handles, cast type, anodised complete all as specified and as directed.
S & F in for 150mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
M&L for 7 to 8 mm thick non skid ceramic coloured tiles (square/ rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed with white cement and coloured pigment to match the tiles over 15mm thick screed bed in CM 1:6.complete all as specified and directed.
M&L for Coloured Glazed ceramic tiles 450x300x6-7mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match including 10mm thick rendering in CM 1:4 on brick wall complete all as specified and as directed.
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, any type of soil, complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 ( Using 40 mm graded crushed stone aggregate) in foundation filling & mass concrete complete all as specified & directed.
M&L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified & directed.
M&L for Providing, cement concrete 1:2:4 type B1,using 20 mm graded stone aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
Providing precast cement concrete as in Manholes Covers 1:2:4 mix type B1 using 20 mm stone aggregate set in CM 1:4 complete all as specified & directed.
M&L for rendering 15 mm thick cement plaster in CM 1:4 on fair faces of brick work / concrete surfaces & finishing the surfaces even and smooth without using extra cement etc complete all as specified and directed.
M&L for Concrete bed to drain pipes including packing under,and haunching against the sides of pipes after they are laid and tested; in Cement Concrete 1:3:6 type C2 for 150 mm dia pipe etc. complete all as specified & directed.
S&F reinforced concrete pipes, class NP3, laid and jointed complete with collars 150 mm complete all as specified & directed.
Returning filling including spreading, levelling, watering and well ramming in layers n. exc 25 cm thick complete all as specified & directed.
Demolition of brick work built in cement mortar including all quoins arches pillar etc. complete all as specified and directed.
Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams;and similar work for fair finished flat surfaces complete all as specified and directed.
Use & waste of formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide, for fair finished flat surfaces complete all as specified and directed.
Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions (Square, rectangular or polygonal on plan), for fair finished flat surfaces complete all as specified and directed.
M&L for reinforcement cement concrete (design mix ) M-25 (20mm graded stone aggregates) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for reinforcement cement concrete (design mix ) M-25 (20mm graded stone aggregates) in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for reinforcement cement concrete (design mix ) M-25 (20mm graded stone aggregates) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for 10mm dia and over mild steel TMT bars cut to length bent to shape required including cracking bending spirally for hopping for columns etc & binding with MS wire of dia not less than 0.9mm complete all as specified and directed.
All as item No 50.00 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded aggregate as in coping complete all as specified and directed.
M & L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red odixe primer complete all as specified and directed.
S&F Providing precast cement concrete louvres and jallies, 25mm thick (measured solid), ncluding all mould- ings but excluding frame complete all as specified and directed.
Removing surplus soil to a distance exc 250 m but not exc 500M and depositing where directed at a level n. exc 1.5 m above starting point complete all as specified and directed.
Removing surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc 1.5 m above starting point complete all as specified and directed.
Materials and Labour for, glazed ceramic exterior wall tiles, 7.5 - 9 mm thick (square/rectangular) area of each tile exceeding 0.06 Sq M but not exceeding 0.18 Sq M,conforming to IS 15622,on vertical surface of wall such as dados, skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick plaster or bedding layer of cement mortar (1:4), complete all as specified and directed.
S&F Framed work as in ornamental or steel gate/revolving gate revolving on bearing plate incl pintel hinges fixed on RCC pillar with PCC block of size required at site as per sample approved by Engr-in charge. Note:-Weight of gate decided by BOO which will be conveyed by GE before fixing and necessary arrangements for weighing of steel gate by the contractor on his own expense.
Excavation in trenches nexc 1.5m wide and nexc 1.5m in depth as in foundation etc as in soft/loose of soil complete all as specified and directed.
M & L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for steel work as in tubular truss incl special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161-1979 gde st-240, including gusset plate pole etc complete all as specified and directed.
S&F for Rolled sections in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming Fe 410 gde E250 fixed complete all as specified and directed.
S&F for rolled ,mild steel plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any forming holes, without any attachment of quality GDE Fe 410-S complete all as specified and directed.
S&F Mild steel bolts, purpose made with hexagonal or square head one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut 16-20mm dia and exc 20cm and n exc 25cm long complete all as specified and directed.
M&L for Point wiring for One light /Exhaust fan point controlled by one switch complete with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, MS sunken boxes incl modular duly painted with one coat of red oxide and one coat of black paint not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost.
Supply and fixing piano switch 6 Amp , 240 volt complete all as specified and directed.
Supplying & fixing for ceiling rose PVC Polycarbonate isolated body 62.5 x 25 mm, three terminals, complete all as specified & directed.
S&F in repair LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed.
Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 4 way with IP-43 protection double door complete with appropriate size bus bar and neutral link complete all as specified and directed.
Supply and fixing MCB SP 1 to 32 Amp ('C' curve) having short circuit rating 10KA, 240 volts complete with connection testing and commissioning. Complete all as specified and directed.
Supply and fixing MCB SPN 40 to 63 Amp ('C' curve) having short circuit rating 10KA, 240 volts complete with connection testing and commissioning Complete all as specified and directed.
Supply and fixing exhaust fan made of sturdy Engineering plastic 5 star rating complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 Core, complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks. (designated 75) locally available best quality laid dry in trenches for protection of underground cable complete all as specified and directed.
Supply and laying GI tube light grade 25mm dia as in cable protection pipe including all fittings complete all as specified and directed.
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 2 way with IP-43 protection double door complete with appropriate size bus bar and neutral link complete all as specified and directed.
Supply and fixing MCB SPN 40 Amp ('C' curve) having short circuit rating 10KA, 240 volts complete with connection testing and commissioning complete all as specified and directed.
Supply and lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 Sqmm 2 Core, complete all as specified and directed.
M&L for Point wiring complete with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, MS sunken boxes duly painted with one coat of red oxide and one coat of black paint not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified Note :Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost for the following :- (a) One light /fan point controlled by one switch
(b) One 5 pin socket outlet 5 Amps on independent board
(c) One 5 pin socket outlet 5 Amps on same board
All as per item No 81.00 here in before but with cable size 2.5 Sq mm for one 5 pin 15/16 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm complete all as specified and directed.
Supply and fixing piano switch 16 Amp , 240 volt all as specifeid and directed.
Supply and fixing 5 Amp socket, 5 pin all as specified and directed.
Supply and fixing 16 Amp socket, multipurpose as specified and directed.
Supply and fixing Electronic fan regulator step type, AC, 230V all as specified and directed.
Supplying and fixing 20 watt LED battan surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly pre-wired upto terminal block, power consumption < 20W, luminaire lumens > 2000 lms, driver efficiency > 85%, power facor > 0.95 THD < 20% as per IEC 61000-3-2, colour temp - 6500 K Surge protection 2.5 KV, 50000 burning hrs (min) as per L 70 criteria, two stages isolated constant current operated driver with range 150 - 270 VAC and safety extra low voltage safe level < 60 VDC as per IEC standard with LM 70 & 80 certification and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.75 Sqmm and fixing arrangements for fixing the light fitting, complete all as specified
Supplying, fixing & testing Bulk head , luminaire 10 watt LED, internally prewired with and including premium quality diffuser for made of die cast aluminium and easy to install snap fit installer complete with all accessories, and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.50 Sqmm and fixing arrangements for fixing the light fitting complete all as specified & directed.
Supply, fixing, connecting & testing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), and including connecting wire with new 3 core 0.50 Sqmm PVC insulated and sheathed copper conductor cable from ceiling rose and also writing MES No with black paint complete all as specified and directed.
M&L for sub main wiring using two 2x 6 sqmm single core PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of dia not less than 20 mm with standard accessories along-with one run of PVC (green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor connected to earth dolly complete all as specified and directed. (NOTE : Two run of single core PVC cable with one run of earth conductor and conduit /batten shall be measured as one unit.)
Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-43 protection double door complete with appropriate size bus bar and neutral link all as specified and directed.
Supply and fixing MCB SPN 40 Amp ('C' curve) having short circuit rating 10KA, 240 volts complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp & using PVC sheathed and insulated three core copper conductor cable of size 2.5 Sqmm and necessary fixing arrangements for fixing the light fitting complete all as specified & directed.
Supply and fixing LED Solar street light all in one fitting 20 Watt including galvanized steel pole 50mm dia medium grade with PCC work for coping of pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified & directed. (Excavation & earth work shall be measured separately)
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Supply and lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 2 Core, complete all as specified and directed.
Dismantling/taking out of Engine from 320 KVA DG set (SM No-580/6168/DG/12) of make Kirloskar Model No 6KL12TA by strip opening of DG set engine Head and refixing of the same after repair/replacement of spare parts including Cylinder head repairing - 02 Nos, CR Bush fitting - 06 Nos, Sleeve cutting and fittings - 06 Nos, Servicing of self starter, Charging Alternator Servicing, nuts, bolts & washers, Adhesive Anabond etc and comprehensive servicing of the DG set including testing on full load, complete all as specified and as directed. Note:- (i) Spare parts shall be measured and paid as supply only items. (ii) Repair/replacement of of any job/item of DG set costing less than Rs 1000.00 are deemed to be included in the rate.
Supply only Sleeve
Supply only Piston assly
Supply only Piston Ring Set
Supply only CR Bearing
Supply only Head Gasket Set complete
Supply only Valve Exhaust
Supply only Valve Intake
Supply only Sheet Insert
Supply only Guide
Supply only Guide Seal
Supply only B check kit for 320 KVA DG set (Oil filter-2, Diesel filter-2, bypass filiter-1 No) complete all as specified and directed.
Supply only Air Filter
Supply and filling of coolant for radiator of DG sets complete all as specified and directed.
Supply and filling of engine oil 15W/40 complete all as specified and directed.
Supply only Connecting Rod Bush
Supply only Connecting Rod
Supply only Water Pump Complete
Supply only V-Belt of any size
Supply only Nozzle kit
Supply only Turbo charger kit
Caliberation of fuel pump including repair/replacement of parts and re-fixing the same, complete all as specified and directed.
Servicing/ Cleaning of radiator including brazing of broken tube of radiator complete all as specified and directed.
S&F EMS Auto Manual controller suitable for 320 KVA DG set, complete all as specified and directed.
M & L for spray painting of Canopy of 320 KVA DG Set with Two coat of synthetic enamel paint by spray painting to achieve smooth and uniform finish incl removal of existing paint, filling up cavities with filler and writing of SM No with black paint complete all as specified and directed.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 4.00 M below normal ground level ) with top edge of the plate not less than 3.00 M below normal ground level , connected to and including galvanised iron strip 32x6mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40 mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 32mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES :- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
rohan traders
3Krishna Enterprises
M/S SHARADA ASOCIATE
Balaji Associates
Attar Singh and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .