Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹10.4 L+₹62,618 (6.38%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹11.9 L+₹2.1 L (21.7%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest Bidder | |
| 4 | L4₹12.0 L+₹2.2 L (22.7%)Rejected-AOC | L4 | Rejected-AOC Other than Lowest Bidder | |
| 5 | L5₹15.5 L+₹5.7 L (57.9%)Rejected-AOC | L5 | Rejected-AOC Other than Lowest Bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
15 Jan 2024, 6:00 pmClosed
GE (S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
REPAIR AND MAINT OF STREET LIGHT AND CONNECTED ITEMS UNDER ZONE-III AREA AT JAIPUR MIL STN UNDER GE (S) JAIPUR
2023_MES_633481_1
GE(S)/J-51P/2023-24 8850/E8
Open Tender
Civil Works
Item Rate
270 days
Jaipur
E class and category b (i)
9 documents required · 9 mandatory
₹500
Yes
GE (S) Jaipur
₹40,000
Yes
23 Mar 2024
19 Dec 2023
23 Jan 2024
19 Dec 2023
15 Jan 2024
2 Jan 2024
Amount
M&L for disconnecting and taking down the U/S street light/ flood light fitting from pole or wall and repair the same (of any type, capacity & make) by replacement of spare parts & making the fitting functional and refixing after repairs all as specified and directed by Engineer-in-Charge. (Note : (i) Spare parts/accessories required to be replaced shall be measured and paid seperately as "Supply only" under the relevent items)
M&L for disconneting and taking down U/S High Mast light fitting from the steel pole and repair the same(of any type, capacity & make) by replacement of spare parts & making the fitting functional and refixing after repairs all as specified and directed by Engineer-in-Charge. (Note : Spare parts/accessories required to be replace shall be measured and paid seperately as "Supply only" under the relevent items)
S&F in replacement of 1100 Volts grade heavy duty cable with inner sheathing of PVC tape and overall PVC sheathed in service connection three core stranded aluminum conductor of size 4.0 sqmm, ISI marked, drawn through steel pole from junction box to street light fitting or for OH connections complete all as specified and directed.
S&F in replacement of New Generation Energy Saving 150 W LED flood light powder coated PDC aluminium body with toughened glass vision having wide operating voltage range & lumen efficacy>100 lm/w.Surge protection upto 10 KV PF>0.95 temp 5700 K to 6500 K IP 66. Note:- Reducer including cutting welding etc if required at site for installing LED fittings shall be deemed to be included in quoted rates.
S&F in replacement of New Generation Energy Saving 250 W LED flood light powder coated PDC aluminium body with toughened glass vision having wide operating voltage range & lumen efficacy>100 lm/w.Surge protection upto 10 KV PF>0.95 temp 5700 K to 6500 K IP 66. Note:- Reducer including cutting welding etc if required at site for installing LED fittings shall be deemed to be included in quoted rates.
S&F in replacement of 60 W LED street light fitting with lens optics on LEDs, IP 66 protected luminaire fixture made from pressure die cast aluminum housing & heat resistance toughned glass cover with one number of 60 W driver, having wide operating voltage range, surge protection 10 KV as directed. Note:- Reducer including cutting welding etc if required at site for installing LED fittings shall be deemed to be included in quoted rates.
S&F in replacement of 70 W LED street light fitting with lens optics on LEDs, IP 66 protected luminaire fixture made from pressure die cast aluminum housing & heat resistance toughned glass cover with one number of 70 W driver, having wide operating voltage range, surge protection 10 KV as directed. Note:- Reducer including cutting welding etc if required at site for installing LED fittings shall be deemed to be included in quoted rates.
S&F in replacement of 100 W LED street light fitting with lens optics on LEDs, IP 66 protected luminaire fixture made from pressure die cast aluminum housing & heat resistance toughned glass cover with one number of 100 W driver, having wide operating voltage range, surge protection 10 KV as directed. Note:- Reducer including cutting welding etc if required at site for installing LED fittings shall be deemed to be included in quoted rates.
Supply only in replacement of LED Driver with surge protector suitable for 45 to 60 watt LED fitting complete all as specified and as directed. Note:-Driver & surge protector shall be of same make or suitable for LED fitting as available at site.
Supply only in replacement of LED Driver with surge protector suitable for 70 to 80 watt LED fitting complete all as specified and as directed. Note:-Driver & surge protector shall be of same make or suitable for LED fitting as available at site.
Supply only in replacement of LED Driver with surge protector suitable for 90 to 100 watt LED fitting complete all as specified and as directed. Note:-Driver & surge protector shall be of same make or suitable for LED fitting as available at site.
Supply only in replacement of LED Driver with surge protector suitable for 150 watt LED fitting complete all as specified and as directed. Note:-Driver & surge protector shall be of same make or suitable for LED fitting as available at site.
Supply only in replacement of LED Driver with surge protector suitable for 250 watt LED fitting complete all as specified and as directed. Note:-Driver & surge protector shall be of same make or suitable for LED fitting as available at site.
S&F in replacement of thermoplastic, polystyrene unbreakable junction box size 260 x 210 x 116 mm suitable for pole mounted outdoor type IP 65 insulated complete with FI clamp & nut, bolts, washers and including resin type terminal block heavy duty suitable for ring lugs with phase seperators between R, Y, B, N terminals and one MCB 'B' series SP 6 amp 10 KA, all duly mounted on din chennel, cable glands for cable entry incl GI double clamp made out of 25x4 mm GI strip complete all as specified and directed.
Supply,lay,connect and commission LT underground cable XLPE of size 16 sqmm 4 core insulated screened PVC bedded galvanised steel strip armoured heavy duty with multi stranded aluminium conductor 1100 volts grade (ISI) marked laid in trenches, ducts, pipes or fixed on pole etc.
Supply,lay,connect and commission LT underground cable XLPE of size 25 sqmm 4 core insulated screened PVC bedded galvanised steel strip armoured heavy duty with multi stranded aluminium conductor 1100 volts grade (ISI) marked laid in trenches, ducts, pipes or fixed on pole etc.
Labour only for repair of U/S timer switch assembly of any type/rating & accessores/ spares including reconnecting and testing complete. Note : - Supply only accessories/ spare parts shall be measured & paid separatley under respective items of Sch `A`
Supply only following accessories/ spares parts :-
Contactors 4 pole 40 Amp
Photo sensors for light sensing Make - Swadeep
Excavation in trenches n.exc 1.5 meter wide and n. exc 1.5 meter in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil.
M&L sand cushioning to PVC underground cable with screened and washed sand and punning to provide a required cover.
M&L bricks for protection cover to underground cable (with old size sub class 'B' bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjaccent brick not exceeding 10 mm as directed.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25 cm depth.
Removing of excavated material (soil) to a distance n.exc 50 meter and depositing where directed at a level n.exc 1.5 meter above the starting point.
M&L for cutting the existing cable from loop and making end termination with aluminium lugs without jointing kit with cable glands suitable for LT U/G cable of following sizes:- Note:- The cable should be enclosed in GI pipe and it should be buried in ground. The cable discipline should be as per the entire satisfaction of Engr-in-Charge.
2x6 to 2x16 sqmm .
4x10 to 25x4 sqmm .
M&L for PCC (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in coping/pedestal of poles including providing necessary formwork for fair finished exposed concrete surfaces including demolition of old coping complete all as specified and as directed.
Supply and fix in replacement steel tubular poles of 9 mtr length with cast iron base plate,finial taper plug, bolts nuts and screws specified type 410 SP-31 complete all as specified and as directed.
M & L for painting to surfaces of existing Steel tubular pole/PCC pole 9.0/11.0 mtr long with attached accessories (cross arms, clamps, GI protection pipe etc) with one coat of aluminium paint after preparation of surfaces including painting to poles with two coats of Red & white synthetic enamel paint two coats in straps of 5 of 30 cm each alternatively upto 1.5 meter all round the poles from the bottom with good finishing and writing the pole number by using synthetic enamel paint of colour as approval by Engr-in-charge & painting of coping upto GL using two coat of cement base paint of approved colour complete all as specified and as directed. Note:- The vegetation or creepers or any soil dump should be cleared from or near the poles before painting.
M&L for Trimming of tree in vicinity of electric supply pole depositing at places n exc 50m complete all as specified and as directed till date of completion.
Material & Labour for boring under road/drain by manual/machine method for inserting GI tubing up to 50 mm dia for cable protection complete all as specified and as directed.
M&L for providing 40mm dia bore GI pipe for passing through bore complete all as specified and as directed.
Material & labour for fixing at poles GI bracket swan neck type of Size 40 to 50 mm bore 1.5 meter length complete with 2 x FI clamps channel and angle iron, nut, bolt & washers including complete fitting and fixture complete all as specified and as directed.
S&F in replacement nature switch for automatic ON/OFF of street light by sensing natural light of 3 phase upto 12KW load. For switching ON< = 30 lux, For switching OFF>=10 Lux, Auto high voltage sense and trip, auto low voltage sense and trip, 50-60HZ, IP66 protection class 2, with 3 nos contactor and 32-40 Amp MCB and copper wiring by minimum of 10 Sqmm Cat part no- swadeep 02EC 12KW3P or equivalent L&T/Legrand/ Siemens
S&F in replacement nature switch for automatic ON/OFF of street light by sensing natural light of 1 phase upto 8KW load. For switching ON< = 30 lux, For switching OFF>=10 Lux, Auto high voltage sense and trip, auto low voltage sense and trip, 50-60HZ, IP66 protection class 2, with copper wiring by minimum of 10 Sqmm Cat part no- swadeep 02EC 8KW1P or equivalent L&T/Legrand/ Siemens
Taking down old unserviceable LT cable of any size or type.
SHREE BHAGWATI ENTERPRISES
LAKSHMI ASSOCIATES
M/s Prakash Enterprises
S.R.Enterprises
ANKIT BUILDERS
M/S TRADE LINKERS
sanjay traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .