| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 CrAccepted-AOC 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹5.8 Cr Quoted ₹6.0 Cr | L1 | Accepted-AOC Lowest and reasonable |
| 2 | L2₹6.0 Cr+₹4.8 L (0.81%)Rejected-Finance 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹6.0 Cr+₹4.8 L (0.81%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹6.1 Cr+₹17.7 L (2.96%)Rejected-Finance | ₹6.1 Cr+₹17.7 L (2.96%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹6.2 Cr+₹22.0 L (3.68%)Rejected-Finance 121 MODEL TOWN AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | ₹6.2 Cr+₹22.0 L (3.68%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹6.2 Cr+₹23.6 L (3.95%)Rejected-Finance | ₹6.2 Cr+₹23.6 L (3.95%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹9.5 Cr
EMD Value
₹8 L
Closing Date
19 Feb 2024, 6:00 pmClosed
CHIEF ENGINEER JAIPUR ZONE JAIPUR
HEAD QUARTER CHIEF ENGINEER JAIPUR ZONE JAIPUR
CONVERSION OF BALANCE LT OH LINE TO UG CABLE FOR SMOOTH FUNCTIONING OF ELECTRIC SUPPLY AT HISAR MIL STN
2023_MES_632841_1
80891
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE Hisar
Please refer tender documents
7 documents required · 7 mandatory
₹3,000
Yes
GE Hisar
₹8 L
Yes
31 Mar 2024
9 Jan 2024
21 Feb 2024
9 Jan 2024
19 Feb 2024
14 Feb 2024
Amount
Supply, installation, commissioning and testing of LT Panel ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) CPRI approved/tested, factory assembled ,out door type, weather and vermin proof (Protection Class IP-54) made out of 3.15 mm (for external) and 2.00 mm (for internal) thick MS Sheet CRCA sheet with both side (front and back) hinged, double door opening for external, rubber lining, locking arrangement, painted internally and externally with powder coating of grey shade (RAL-7032) as per seven tank process complete mounted on angle iron 50mm x 50mm x 5 mm legs 45 cm high above GL and 15 cm embedded in ground with and including blocks of PCC 1:2:4 type C1 of block size 30x30x30 cm comprising of the following. (a) Bus bar chamber having 4 nos air insulated Aluminium strip bus bars of rating not less than the 1.5 times the rated capacity of the incomer MCCB, bus bar must be colour coded heat shrinkable as well as outgoings shall have aluminium four pole (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs. (b) Incoming :- (i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade, 630 amps rating 4 pole, 50 KA, Adjustable thermal and magnetic release specially fixed for incoming supply with overload ,short circuit and adjustable type (Ics=100%Icu).-01 No.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes
size 500sq mm 3.5 core
size 50 sq mm 3.5 core
size 70 sq mm 3.5 core
size 95 sq mm 3.5 core
size 120 sq mm 3.5 core
size 150 sq mm 3.5 core
size 185 sq mm 3.5 core
size 240 sq mm 3.5 core
size 300 sq mm 3.5 core
size 400 sq mm 3.5 core
size 25 sq mm 4 core
size 35 sq mm 3.5 core
16 sq mm 4 core
10 sq mm 4 core
6 sq mm 4 core
16 sq mm 2 core
10 sq mm 2 core
6 sq mm 2 core
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete all as specified and directed. Note :- Rate of flat iron, clamps, nuts, bolts & washer shall be included in the rate quoted by the contractor. Nothing extra shall be paid on this account.
M&L Earthing complete with galvanised mild steel earth electrode plate 600 X 600 X 6 mm thick buried directly and vertically in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to earthing test point all as specified and testing on completion including provision of earth strip protected by galvanised iron 40 mm bore medium grade pipe with all fittings from the earth electrode fixed along pole with and including 25 x 6mm flat iron clamp, bolts, nuts and washers and watering pipe shall be 20 mm bore GI medium grade from top of the earth electrode to bottom of the earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm x 300 mm (inner) and 250 mm deep including all excavation and earth work in any type of soil and removal of soil upto 50 metre, PCC pit with pre-cast RCC cover with handle, charcoal/salt, funnel , CI frame etc complete all as specified and directed.
Note: (i) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.50 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. Reinforcement in cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Item includes the cost of GI pipe for protection of earth wire including earth wire up to 7.5 Metre. (iii) Any variation of GI pipe and GI wire below or above 7.5 metre shall be adjusted through deviation. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
M&L,Earthing complete with galvanised mild steel earth electrode plate 600 X 600 X 6 mm thick buried directly and vertically in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to earthing test point all as specified and testing on completion including provision of earth wire protected by galvanised iron 15 mm bore medium grade pipe with all fittings from the earth electrode fixed along pole with and including 25 x 6mm flat iron clamp, bolts, nuts and washers and watering pipe shall be 20 mm bore GI medium grade from top of the earth electrode to bottom of the earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm x 300 mm (inner) and 250 mm deep including all excavation and earth work in any type of soil and removal of soil upto 50 metre, PCC pit with pre-cast RCC cover with handle, charcoal/salt, funnel , CI frame etc complete all as specified and directed.
Note: (i) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.50 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. Reinforcement in cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Item includes the cost of GI pipe for protection of earth wire including earth wire up to 7.5 Metre. (iii) Any variation of GI pipe and GI wire below or above 7.5 metre shall be adjusted through deviation. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
Supply, installation, commissioning and testing of LT panel box (Kiosk), out door type, platform mounted, suitable for 415 Volts, 50 Hz , 3 phase, 4 wire supply, CPRI approved, factory assembled, having bus bar chamber with insulated Aluminium bus bar 160 Amps rating installed on porcelain insulators, the panel shall be dust and vermin proof double door made out of 3.15mm CRCA MS sheet, outer & inner (2 mm thick) and 40 x40 x 6mm thick angle iron for base frame work, LT panel box should be powder coated including internal wiring with PVC insulated solid copper conductor FRLS cable of appropriate sizes but not less than 4 sqmm, front opening type with provn for cable entry with double door shutter including locking arrangement with 2 keys complete all as specified and directed
S & F PVC junction box for street light of size not less than 300mm x 200mmx 100mm made out of thermoplastic polycarbonate, having front side openable with locking arrangement and also provide 4 Nos aluminium busbar of rating 60 Amp and MCB 6 Amps single pole and provision of 2 No cable entry including fixing with proper MS flat clamp of suitable size complete all as specified and directed.
Supply and fixing FRLS PVC insulated copper conductor of size 1.5sqmm 3 core fixed on pole/wall as required complete all as specified and directed.
S & F cable route indicator of size 100 mm x 100 mm x 5 mm thick GI plate with insertion there on bolted welded to 35 mm x 35 mm x 6 mm angle iron 60 cm long and fronting the sae in ground with PCC 1:3:6 Type C2 as required for LT/HT cable including necessary earth work complete all as specified and directed. Note :- the rate for PCC shall be included in the rate quoted by the contractor. Nothing shall be extra paid to the contractor on this account
Dismantling of ACSR conductors and GI Earth wire complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete all as specified and directed.
Dismantling insulators any type, any size complete all as specified and directed.
Supply and laying double wall corrugated pipe(DWC) confirming to IS 19430 Part -I complete all as specified and as directed of following sizes:-
size 50 mm bore pipe
size 80 mm bore pipe
M&L for rigid non-metallic PVC conduit 25 mm dia including fixing on pole/wall with fittings such as tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as coupler lock, nuts, saddles, pipe hooks etc. complete all as specified and as directed of approved sample complete all as specified and directed.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying underground pipe upto 150mm dia complete all as specified and directed. Note :- GI/DWC pipe shall be measured and paid seperately in respective items.
Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in all kind of soil complete all as specified and directed. Note:- Unit rate of this item including the cost of removal of surplus soil to distance of not exc. 50 M as directed
Returning, filling in including spreading, levelling, watering and well ramming in layers n. exc 25 cm thick. Etc complete all as specified and directed.
M&L for sand cushioning 230mm thickness with river dry sand (One layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punned down to 180mm after laying of cable in trenches for protection of cable complete all as specified and directed. Note : For the purpose of payment, only punned thickness shall be measured
M&L for brick protection with sub Class`B` bricks old size laid dry, flat over cable perpendicular across the cable in trenches complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20 mm crushed graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles etc complete all as specified and directed.
Dismantling old unserviceable earthing by taking out plate and connected items including making good existing disturbed surface complete all as specified and directed
Dismantling of old unserviceable LT Panel of any size and type including making good existing disturbed surface complete all as specified and directed
Taking down old unserviceable copper cable multistranded PVC insulated PVC Seathed 1.5 Sqmm 3 Core complete all as specified and directed
Sant Construction Co.
AMIT ASSOCIATES
J.D.Builders
Som Projects Pvt. Ltd.
M/s Khanna Enterprises
M P TYAGI ENGINEERS AND CONTRACTORS
MAHESH KUMAR SINGLA CONTRACTOR
BD AGARWAL BUILDTECH INDIA PRIVATE LIMITED
A.V BUILDERS
VERMA BROTHERS
Shekhar Enterprises
Nanak Buildtech
stage.html
html • 0.11 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .