Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | I₹64,900Accepted-Finance 58 KAILASHPURAM GOVINDPURAM GAZIABAD | GHAZIABAD | UTTAR PRADESH | I | Accepted-Finance Accept | |
| 2 | II₹70,000Rejected-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | II | Rejected-Finance Reject | |
| 3 | III₹75,000Rejected-Finance BH 16 MANSAROVER COLONY LINE PAR MORADABAD UTTAR PRADESH 244001 | MORADABAD | UTTAR PRADESH | 244001 | III | Rejected-Finance Reject |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
12 Dec 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
132 KV S/S Bharua Sumerpur
Work
2023_UPTCL_866055_1
TS-37/ETD(H)/2023-24
Open Tender
Electrical Works
Lump-sum
30 days
132 KV S/S Bharua Sumerpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹295
Yes
Executive Engineer
₹2,000
Yes
15 Dec 2023
29 Nov 2023
13 Dec 2023
29 Nov 2023
12 Dec 2023
29 Nov 2023
Amount
Details of Work.
Providing & fixing work of 01 No. vacuum interrupter with top bushing of Y phase of spare 33 KV VCB at 132 KV S/S Mahoba under ETD Hamirpur :-
33 KV VCB (Shreem Make) Sr. No. 3546-18, spare Circuit Breaker (mfg. year - 2018)
By doing following work in above circuit breaker :-
Providing and Fixing of Vacuum Interrupter with top bushing porcelain in 33 KV spare circuit breaker of Shreem as per sample provided with same rating and specifactions and doing the following works in this breaker (i) Cleaning of porcelain of drive insulator and porcelain of vacuum interrupter of each pole. (ii) Checking & adjustement of snatch gap, travel of drive insulator rod & tie rod of each pole. (B) After fixing of Vacuum Interrupter of above VCB, following tests are to be carried out ;- (i) Opening & closing time of breaker of each pole. (ii) Carrying out Contact Resistance Measurement (CRM test) of each pole. (iii) Checking of megger values of breaker poles. (iv) Checking triping of breaker at 70% DC voltage. DC supply will be provided at spare CB by deparment. (v) Checking the CLOSE/OPEN operation of breaker by local. (vi) Prepare and submit the site report of above circuit breaker.
Rates qouted by the bidders shall be without taxes. Taxes applicable if any to paid extra
P&H Engineering
TIRUPATI ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .