Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹23.7 LAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹23.7 L | 1 | Accepted-AOC Being L1 |
| 2 | 2₹28.8 LRejected-Finance GROUND BALURGHAT COMPOUND NEAR TRIPURA ROAD KHANAPARA ROAD GUWAHATI KAMRUP METROPOLITAN ASSAM 781029 | KAMRUP METRO | ASSAM | 781029 | ₹28.8 L | 2 | Rejected-Finance Being other than L1 |
| 3 | 3₹30.2 LRejected-Finance | ₹30.2 L | 3 | Rejected-Finance Being other than L1 |
| 4 | 4₹34.4 LRejected-Finance | ₹34.4 L | 4 | Rejected-Finance Being other than L1 |
| 5 | 5₹38.7 LRejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | ₹38.7 L | 5 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | M/s Rohit Construction Co. L1 | Aman Corporation L7 | M/S SHREE SHYAM TRADERS L2 | ALPHA ENGINEERING COMPANY L8 | V.K. Infra Engineering L3 | HINGLAZ ENTERPRISES L6 | BALAJI PROJECTS L4 | BIDAWAT ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators, wooden boxes, MS sunken boxes, round block etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
Note for all items :
(i) Repair and maintenance intimated to the contractor or his rep/supervisor at any time day or night, through complaint slip or telephonically must be rectified by the contractor within 8 Hrs, if contractor fail to rectify the fault/complaint within 8 hrs a penalty of rs 200 per day per complaint deducted till the complaint/fault rectified. (ii) All material required for the repair/mainatenane work as considerd in the CA will be made available by the contractor within 3hrs.
(iii) contractor will arrange two teams as one for rewiring and second team for attending complaints 24/7 through out the CA provision.
(iv) Contractor should deposited at least 80% of material after acceptance of the contract include in this CA in MES store and same will be issued with comlaint on daily basis.
(v) Quoted rate deemed to be inclusive of all labour, equipment and T&P material/arrangment to attend the day to day maintenance complaint on daily basis.
(vi) Old unsv material recived against new material (All old unsv material any type) etc may transport and deposited to AGE Kanasar store yard by contractor as per directions of Engr-in-charge and no extra payment made out on this account.
(vii) Contractor should collect complaint slip on daily basis prior to 09:00 to 10:00 hrs without fail and deposite the same after rectification within time period.. | 717 | Point | 10 ₹7,170 | 40 ₹28,680 | 50 ₹35,850 | 120 ₹86,040 | 10 ₹7,170 | 50 ₹35,850 | 10 ₹7,170 | 17 ₹12,189 |
| 2.00 | M&L for point wiring concealed type with PVC insulated (unsheathed ) cable 1.5 Sq mm (Nominal area) multi stranded FRLS copper conductor 1100 V grade & continuous earth wire PVC insulated 1.5 Sq mm copper solid conductor connecting to common earth in existing PVC conduit with complete required accesories and including new/existing sunken boxes (as per site requirment) & fixing new 3mm thick plastic laminated sheet top cover,sheet screws and after removing old unserviceable sunken box/plastic laminated sheet (including cutting chases & making good the disturbed surface) complete all as specified and directed by Engineer-in-Charge for the following:-
Note : The cost of bakellite sheet is included in the quoted rate)
(a) For one light /fan/ buzzer point controlled by one 5 Amp switch one way | 30 | Per point | 300 ₹9,000 | 415 ₹12,450 | 300 ₹9,000 | 300 ₹9,000 | 400 ₹12,000 | 300 ₹9,000 | 400 ₹12,000 | 297 ₹8,910 |
| 2.01 | (b) For One bell point controlled by one, bell push complete all as specified and directed. | 10 | Per point | 300 ₹3,000 | 460 ₹4,600 | 350 ₹3,500 | 300 ₹3,000 | 350 ₹3,500 | 1,000 ₹10,000 | 450 ₹4,500 | 297 ₹2,970 |
| 2.02 | (c) For one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches. | 10 | Per point | 100 ₹1,000 | 190 ₹1,900 | 150 ₹1,500 | 200 ₹2,000 | 200 ₹2,000 | 250 ₹2,500 | 150 ₹1,500 | 137 ₹1,370 |
| 2.03 | (d) For one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board. | 15 | Per point | 350 ₹5,250 | 480 ₹7,200 | 250 ₹3,750 | 300 ₹4,500 | 400 ₹6,000 | 250 ₹3,750 | 550 ₹8,250 | 297 ₹4,455 |
| 3.00 | Ditto all as per item No. 2.00 here-in-before but for one 3/5 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour. | 10 | Per point | 400 ₹4,000 | 570 ₹5,700 | 350 ₹3,500 | 350 ₹3,500 | 550 ₹5,500 | 480 ₹4,800 | 650 ₹6,500 | 397 ₹3,970 |
| 4.00 | M & L for modular point wiring with and including single core FRLSH PVC insulated and unsheathed stranded copper conductor cable of size 2.5 sqmm, 1100 volts grade (ISI Marked) drawn through existing PVC concealed conduit with complete required accessories with including new modular metal flush boxes of requisite module concealed in wall or on wall/Surface (as per site) for mounting fittings like modular Switches, sockets, regulators etc with and including modular cover plates with frame of requisite modules and including 2.5 sqmm FRLSH PVC insulated and unsheathed stranded copper conductor cable as earth wire and connected to common earth dolly and making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge for the following
(a) For one light /fan/ buzzer point controlled by one 5 Amp switch one way
Note : (i) Cost of cutting/leaving forming chases for conduits, sinking for modular metal flush boxes and making good shall be deemed to be include in quoted rate of this item.
(ii) The quoted rates of this item shall deemed for include for modular metal flush boxes/open pvc modular box of requisite module and modular cover plate with frame of requisite moduleand all complete accesories. Colour as approved by Engr-in-charge/GE. | 50 | Per point | 350 ₹17,500 | 550 ₹27,500 | 350 ₹17,500 | 430 ₹21,500 | 500 ₹25,000 | 450 ₹22,500 | 600 ₹30,000 | 487 ₹24,350 |
| 4.01 | For One bell point controlled by one, bell push complete all as specified and directed. | 5 | Per Point | 350 ₹1,750 | 600 ₹3,000 | 350 ₹1,750 | 250 ₹1,250 | 550 ₹2,750 | 1,000 ₹5,000 | 650 ₹3,250 | 487 ₹2,435 |
| 4.02 | For one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches. | 20 | Per Point | 200 ₹4,000 | 295 ₹5,900 | 300 ₹6,000 | 250 ₹5,000 | 250 ₹5,000 | 350 ₹7,000 | 200 ₹4,000 | 177 ₹3,540 |
| 4.03 | For one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board. | 20 | Per Point | 400 ₹8,000 | 615 ₹12,300 | 400 ₹8,000 | 300 ₹6,000 | 400 ₹8,000 | 350 ₹7,000 | 650 ₹13,000 | 487 ₹9,740 |
Updated dates
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
12 Dec 2025, 6:00 pmClosed
GE(N) Bikaner
GE(N) Bikaner (Raj)-334001
REPAIR TO CERTAIN INTERNAL WIRING AND ALLIED WORKS AND REPAIR/MAINTENANCE OF LED FLAME PROOF LIGHT FITTINGS, DBS, SWITCHES AND CONNECTED WORK AT MIL STN KANASAR UNDER GE(N) BIKANER
2025_MES_731244_2
GE (N) BKN-TOKEN/26/2025-26
Open Tender
Miscellaneous Works
335 days
GE(N) Bikaner
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE(N) Bikaner
₹86,000
Yes
19 Feb 2026
21 Nov 2025
19 Dec 2025
21 Nov 2025
12 Dec 2025
28 Nov 2025
Amount
(b) For One bell point controlled by one, bell push complete all as specified and directed.
(c) For one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches.
(d) For one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
Ditto all as per item No. 2.00 here-in-before but for one 3/5 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
For One bell point controlled by one, bell push complete all as specified and directed.
For one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches.
For one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
For one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board
For One bell point controlled by one, bell push complete all as specified and directed.
For one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches.
For one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
For one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board
Ditto all as per serial item No. 5.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
For One bell point controlled by one, bell push complete all as specified and directed.
For one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches.
For one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
For one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board
Ditto all as per serial item No. 7.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
M&L for fixing switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
M&L for fixing bell push, flush type, 5 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
M&L for fixing Bell ‘Ding Dong’ / ‘Multi Music’ Type, AC, 230 Volts, ISI marked, complete all as specified and as directed.
M&L for fixing socket outlet, 5 pin, 5/6 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed.
M&L for fixing switch socket combination, 5 in 1, 5/6 Amps, flush type, 230 Volts, ISI marked, complete with junction box all as specified and as directed by Engr-in-Charge.
M&L for fixing switch socket combination, 5 in 1, 15/ 16 Amps, flush type, 230 Volts, ISI marked, complete with junction box all as specified and as directed.
M&L for fixing ceiling rose, surface backelite , three terminal AC, 230 volt complete all as specified.
M&L for fixing switch modular type, 1 Module single pole, one way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed by Engr-in-Charge.
M&L for fixing fan step regulator modular type, 100W, 1 Module electronic socket type 5/4 Step controll, 230 Volts, AC, 50 Hz (ISI marked) complete all as specified and as directed by Engr-in-Charge.
M&L for fixing bell push modular type, 1 Module single pole, one way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed by Engr-in-Charge.
M&L for fixing socket outlet modular type 3 pin socket 5/6 Amp, 230 Volts, ISI marked, complete with junction box/ all as specified and as directed by Engr-in-Charge.
M&L for fixing switch socket combination, 5 pin, 5 Amps, modular type, 230 Volts, ISI marked, complete with junction box all as specified and as directed by Engr-in-Charge.
M&L for fixing switch & socket, 5 in 1(multisocket), 5/16 Amps, modular type, 230 Volts, ISI marked, complete with junction box all as specified and as directed by Engr-in-Charge.
M&L for fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed by engineer-in-charge.
M & L for submain (single phase) wiring complete with and including 6.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through Existing PVC conduit including accessories and fixed on walls and 6 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete including taking down old unsv submain Aluminium/ copper wiring all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 6.0 sqmm PVC insulated wire and one run of 6 sqmm wire and one run of PVC conduit shall be measured as one unit length. Make:- Richa/Finolex/Havells/RR Kabel Make of caping/casing :- Prestoplast/Finolex/supreme
M & L for submain (single phase) wiring complete with and including 6.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through PVC concealed conduit of suitable size including accessories and fixed on walls and 6 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete including taking down old unsv submain Aluminium/ copper wiring all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 6.0 sqmm PVC insulated wire and one run of 6 sqmm wire and one run of PVC conduit shall be measured as one unit length. Make:- Richa/Finolex/Havells/RR Kabel Make of caping/casing :- Prestoplast/Finolex/supreme
M & L for submain (single phase) wiring complete with and including 4.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through Existing PVC conduit including accessories and fixed on walls and 4 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete including taking down old unsv submain Aluminium/ copper wiring all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 4.0 sqmm PVC insulated wire and one run of 4 sqmm wire and one run of PVC conduit shall be measured as one unit length. Make:- Richa/Finolex/Havells/RR Kabel Make of caping/casing :- Prestoplast/Finolex/supreme
M & L for submain (single phase) wiring complete with and including 4.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through PVC concealed conduit of suitable size including accessories and fixed on walls and 4 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete including taking down old unsv submain Aluminium/ copper wiring all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 4.0 sqmm PVC insulated wire and one run of 4 sqmm wire and one run of PVC conduit shall be measured as one unit length. Make:- Richa/Finolex/Havells/RR Kabel Make of caping/casing :- Prestoplast/Finolex/supreme
M&L for fix in replacement sheet metal enclosure double door, powder coated for MCB DB SPN following way fitted with neutral link, earth bar, din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge. (a) MCB DB SPN 4 way
MCB DB SPN 8 way
MCB DB SPN 12 way
M&L for fix in replacement/improvement TPN DB,4 way Vertical type,440V,3 phase with rated busbar 200 Amps, double door type suitable for MCCB as a incomer and MCBs as out going, grouted in walls with Fixing arrangemant complete including making good the disturbed surfaceof wall, Ceiling, floor etc to match with existing surface complete all as specified and directed by Engineer-in-Charge. Make-Legrand cat No-5077 50 or L&T, C&S, Havells,
M&L for fix in replacement/improvement MCB Distribution board double door type TPN 4 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity including taking down old unsv MCB DBs complete all as specified and as directed.
M&L for fix in replacement/improvement 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN 40 to 100 Amp in the DB complete with connection testing and commissioningwith connection testing and Commissioning incl taking down old unsv MCB complete all as specified and as directed.
M&L in repair/replacement of switch, socket, fan regulator etc as per following, flush type, 230 Volts, ISI Marked,including making hole in sheet top cover and connecting up/fitting properly all as per site requirement, ISI marked, complete all as specified and as directed. (a) Electronic fan regulator, flush type, stepped type with 5 step control
Switch piano, flush type, single pole, one way, 5/6 Amp
Switch piano, flush type, single pole, one way, 15/16 Amp
Socket outlet, 5 pin, 5/6 Amp, flush type, 230 Volts
Socket outlet universal type, 6 pin, 15/16 Amp, flush type
Switch socket combination box multi purpose with complete PVC board 5 pin 5 Amps flush type including requird copper conductor of existing size complete.
Switch socket combination box multi purpose with complete PVC board 3 pin 15 Amps and 3 pin 5 Amps flush type multipurpose 2 in one including requird copper conductor of existing size complete.
M&L for fix in replacement Lamp holder insulated body with back plate for batten fitting complete all as specified and directed by Engr-in-Charge.
M&L for fix in replacement Ceiling rose 3 phase/PVC/polycarbonate, isolated body all as specified and directed. Make Anchor/Legrand/Crabtree
M&L for fix in replacement Modular type fittings for following complete wth all requirment as per site to complete all as specified and directed by Engr-in-Charge. (a) Switch Modular type 5/6 Amps single pole one way
Modular type bell push 5/6 Amps one way
Switch Modular type 16Amps single pole one way
Modular type socket multi purpose 3 pin 5/6 Amps
Modular type socket muli purpose 3 pin 5/15 Amps multipurpose 2in one
Modular type fan regulator single module / double module type 0-5/4 step type
M&L for fix in replacemet MCB SP 240V ,6 to 32 Amps, 10 KA, "C" curve rating ISI marked and connecting complete all as specified.
M&L for fix in replacemet MCB SPN 240V, following Amps, 10 KA, "C" curve rating ISI marked and connecting complete all as specified. (a) MCB SPN 240V, 32 Amps,
SPN 240V , 40 to 63 Amps
M&L for fix in replacemet of MCCB following capacity in amps, 4 pole, 415 volts, fixed type breaking capacity 16KA complete all as specified and as directed by Engr-in-charge. (a) MCCB 63 amps, 4 pole, 415 volts
MCCB 100 amps, 4 pole, 415 volts,
M&L for dismantling and taking out burnt copper winding from ceiling fan/Exhust Fan of any type and sweep a following of any make, model, type and rewinding the same with new super enameled copper wire of similar gauge and number of turns as exists for full speed, including cleaning and greasing of bearing/bushes, taping, varnishing, heating and replacement of defective parts (measured seperatly as mentioned below) and reassembling of fan motor and refixing the fan after testing complete to the entire satisfaction of the Engr-in-Charge. (a) ceiling fan of sweep 1200mm any make, model, type Note : Old winding broken in fron of JE/Engr-in-Charge in MES area by contractor rep. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL
For ceiling fan of sweep 1400mm any make, model, type. As per ser item No 38 as mentioned above.
For Flame Proof ceiling fan any make/model model size 1200/1400 mm sweep as per site. As per ser item No 38 as mentioned above.
For Exhaust fan metallic/PVC body 300 mm sweep any make / model size with super enameled copper winding wires of size 35/36 SWG or as per existing size of wire confirming to IS. As per ser item No 38 as mentioned above.
For Exhaust fan metallic/PVC body 450 mm sweep any make / model size with super enameled copper winding wires of size 35/36 SWG or as per existing size of wire confirming to IS. As per ser item No 38 as mentioned above.
for Flame Proof Exhaust fan metallic body 450 mm sweep any make / model size with super enameled copper winding wires of size 35/36 SWG or as per existing size of wire confirming to IS. As per ser item No 38 as mentioned above.
M&L in replacement of Ceiling fan components with proper and complete as following, all as specified and as directed by Engr-in-charge. (a) Ball bearing of suitable size for ceiling fan 1200mm / 1400mm sweep complete all as specified & as directed. Make: ''NBC/SKF conforming to IS
Brass bush suitable for ceiling fan any make/model all as per original size/shape/type conforming to IS complete.
Shaft of ceiling fan as per existing size and shape complete.
Fan blades (Set of Three) for 1200/1400 mm sweep fan as per existing size with proper fitting complete.
Capacitor 230V, 50Hz,2.5MFD for ceiling fan. Make :- Asain/ Usha / Universal/Tibcon
Down rod one foot long suitable for 1200/1400mm sweep of ceiling fan all as required at site complete.
PVC canopies (set of two) as per existing size and required at site complete.
Broken bottom cover (bowi) of ceiling fan of any make and model with existing size & Shape complete.
D' clamp with nuts, check nuts, quarter pin and rubber reel suitable for 1200/1400mm sweep of ceiling fan all as required at site complete.
Capacitor 230V,50Hz,4.0 MFD for exhaust fan, Make:- Asain/ Usha / Universal/Tibcon
PCB for 1200/1400 mm sweep BLDC fan as per existing at site with same specification all complete as directed
Taking down unserviceable Geyser including bushes, washers, mounting rubbers, nuts, bolts and clamp from existing place and re-fixing at same place after repair with required maintanance/replacement of components as under here-in-after complete all as specified & as directed.
M&L for fix in replacement high density polythene pipe (HDPE) connection arrangement with pipe of pressure rating 2.5kgf/cm2, 15mm bore 30cm to 45cm long with brass unions one ( Chromium plated ) one on each side in reapir to Geysers 25 /50 litres Pipe shall be as per I.S complete all as specified & as directed.
M&L for fix in replacementThermostat switch ISI marked to Geysers 25/50 litres all as specified and directed by Engineer-in-Charge.
M&L for fix in replacement heating element ISI Marked of rating 1.5 KW capacity including washers for 25 ltrs capacity Geysers all as specified. Make :- THETA/ ALERT
M&L for fix in replacement heating element ISI Marked of rating 2.0 KW capacity including washers for 25 ltrs capacity Geysers all as specified. Make :- THETA/ ALERT
M&L for fix in replacement Stainless steel inner tank suitable for geyser of capacity 25 Ltr complete all as specified and directed.
M&L for fix in replacement Outer tank made of MS sheet powder coated suitable for geyser of capacity 25 Ltr complete all as specified and directed.
M&L for fix in replacement of neon indicator lamp round or rectangular type complete all as specified and directed.
M&L for fix in replacement of Geyser bottom assembly kit of 7 hole/9 Hole/6 hole as per existing complete including, bolts and rubber gasket for 25/50 litres capacity geysers as per requirement with the same make which is to be replaced.
M&L for fix in replacement self ballasted LED batten Extruded PVC body with PC diffuser, fin and groove shap base for batter heat dissipation 4 feet 20 watt to be install at any height on wall / ceiling having power factor more than 0.90 , rated voltage AC 220-240 Volt, 50 Hz, cool white 6500K colour temperatur, CRI > 80 all as specified and directed.
M&L for fix in replacement self ballasted LED batten, extruded PVC body with PC diffuser fin and groove shape base for batter heat dissipation 2 feet 10 watt to be install at any height on wall/ceiling having power factor more than 0.90, rated voltage AC 220-240 Volt, 50 Hz , cool white 6500K color temperature, CRI>80 etc complete all as specified and directed.
M&L for fix in replacement square surface mounted LED 06 Watt surface mounted square fixture with premium diffuser and separate electronic driver.flat panel, alumminum housing including surface panel ring complete all as specified and directed Make:- Havells Cat Part No- LHEAAKP7IL1W006 or equivalent of Bajaj, Crompton, Philips,Orient.
M&L for fix in replacement round surface mounted LED 12 Watt slim surface mounted LED panel with premium diffuser, including surface panel ring complete all as specified and directed Make:- Syska Cat Part No- SSK-SDC-12W-N or equivalent of Bajaj, Crompton, Philips, Havells, Orient
M&L for fix in replacement fully diffused recessed mounted 2' X 2 ' LED luminaire, 36 Watt Environmental friendly, new generation,aesthetically designed, white powder coated CRCA housing ultra modern recess mounting luminaire with high translucent frosted diffuser, having efficency upto 100 Lumens/watt, rated voltage 240 Volt, frequency 50 Hz, PF > 0.95, THD < 10% , CRI > 80 suitable for indoor spaces. Make:- Havells Cat Part No- LHEBAEP7IW1W036 or equivalent of Bajaj, Havells, Philips and Crompton
M&L for fix in replacement security lights LED 30 W Energy saving & Environmental friendly long life versatile pressure die cast aluminium IP 65, CRI>80, PF >0.90 LED Wall mounted Light Luminaries are made of die casted aluminium body and toughened glass cover for uniform light spread including 40 mm dia( or higher size as per manufacturers recommendation) medium grade GI pipe (bend to shape or as per manufacturers recommendation ) bracket 1.5 mtr long complete with MS flat iron clamp (clamps shall be 40 x 5 mm MS flat) nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer including connection complete all as specified and directed. Make- Havells Cat No LHEXAYP7PN6K030 or equivalant in Bajaj ,Crompton, Phillips and Orient
Material and labour for dismantling old earthing and supply, installation and testing earthing complete with galvanisedsteel earth plate electrode of size 60 cm×60 cm.× 6mm thick, buried directly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to and including galvanised iron earth lead wire 4.0 mm dia by means of GI bolts/nuts/washers, protected by 15 mm bore GI medium grade pipe.Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, RCC cover & frame, PCC (1:3:6) type C-2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation and earth work , all as specified and shown in electrical plate No 3 of MES Schd Part-I. Notes :- (i) PCC Chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting maner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate. (iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Material and labour for dismantling old earthing of any type. Supply, installation, testing of advanced maintenance free environment friendly CPRI approved earthing 10 feet long 17 mm dia earth electrode made high tensile low carbon steel circular rods, molecular bonded copper on outer surface (minimum copper bonded thickness 250 micron) with terminal to connect incoming copper strip 25 x 3 mm earthing strips with the equipment/machinery of desired length as per site requirement with 02 bags (25 Kg each) of environment friendly backfill compound with ROHS test certificate for each. The remaining space will be filled with soil and top of earth pit covered with high density polymer.Earth pit chamber cover of dimension (300 mm x 300 mm x 214 mm) with locking seal as to achieve the desired ohmic value complete all as specified and directed. Note : (i) Payment will be released only after the resistance value achieved less than 1 ohm. If value of resistance found more than 1 ohm contractor will do the fresh earthing without any extra cost. (ii) Rate of Copper strip 25x3 mm from earthing terminal to equipment/machinery with suitable size nuts/bolts and washers is deemed to be included in rate quoted by tendrer.
Material and labour for dismantling old earthing and Supply , installation and testing earthing complete with galvanised iron earth plate electrode of size 60 cm×60 cm.× 6mm thick, buried directly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to and including GI Strip 32 x 6 mm (upto the body of equipment) by means of GI bolts/nuts/washers, protected by 40 mm bore GI medium grade pipe.Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, RCC cover & frame, PCC (1:3:6) type C-2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation and earth work , all as specified and shown in electrical plate No 3 of MES Schedule Part-I. .Notes :- (i) PCC Chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting maner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate. (iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
PVC non modular gang box 2 way suitable for 5/6 amp switch
PVC non modular gang box 4 way suitable for 5/6 amp switch and socket
PVC non modular gang box 6 way suitable for 5/6 amp switch and socket
Metal flush GI Box with Modular frame plate 1/2 way suitable for switch, socket and regulator
Metal flush GI Box with Modular frame plate 3 way suitable for switch, socket and regulator
Metal flush GI Box with Modular frame plate 4 way suitable for switch, socket and regulator
Metal flush GI Box with Modular frame plate 6 way suitable for switch, socket and regulator
Metal flush GI Box with Modular frame plate 8 way suitable for switch, socket and regulator
Metal flush GI Box with Modular frame plate 12 to16 way suitable for switch, socket and regulator
Surface mounting plastic Boxes for any type suraface with Modular frame plate 1/2 way suitable for switch, socket and regulator etc.
Surface mounting plastic Boxes for any any type suraface with Modular frame plate 3 way suitable for switch, socket and regulator
Surface mounting plastic Boxes for any any type suraface with Modular frame plate 4 way suitable for switch, socket and regulator
Surface mounting plastic Boxes for any any type suraface with Modular frame plate 6 way suitable for switch, socket and regulator
Surface mounting plastic Boxes for any any type suraface with Modular frame plate 8 way suitable for switch, socket and regulator
Surface mounting plastic Boxes for any any type suraface with Modular frame plate 12 to 16 way suitable for switch, socket and regulator.
M&L for fix in replacement PVC non modular MCB box suitable for MCB 6 to 32 Amp complete all as specified and directed by Engineer-in-Charge.
M&L for fix in replacement PVC rectangular casing caping with accessories of suitable size complete all as specified and directed.
M/L for GI Tubes, of size 40mm dia light grade ,galvanised , with fitting fixed to wall/pole/ceiling or laid in floors complete including taking out old one all as specified and as directed.
M & L for Supplying, laying, connecting and testing in trenches, under floors/ roads or on walls Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armored, electric power cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade, of size 10 sqmm, 2 core including taking out old one all as specified and directed by Engineer-in-Charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation for laying cable etc and getting out in soft/loose soil complete all as specified and directed.
Returning,filling in and including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified and directed.
Removing of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M&L for laying un-reinforced precast concrete cable cover, class LV type-1 with peak, size 250mm x 150mmx 40mm for protection of cable
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes :-(i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
M&L for laying, testing and commissioning in replacement LT copper cable 1.1 KV Grade 2.5 Sqmm 3 core steel wire armoured PVC insulated copper cable laid in duct / tray / wall / ceiling with the help of steel clamps including cable glands with rubber cover etc complete all as specified & as directed.
M&L for fix in replacemnt LED Bulb 230V AC 09 watt cool day light 6500K heavy duty complete in wall lights as per existing all as specified and directed by Engineer-in -charge.
M&L for fix in replacement decorative wall light fixture for living room made up of suitable unbreakable plastic material as directed including 9 watt Led lamp B22 Base light fitting complete all as specified and directed by Engineer -in-Charge. Make :Havells Cat Part No LHFOFUE1TZ1W012 or equivalent in Philips, Crompton, Surya, Bajaj ,Wipro, Orient
M&L for fix in replacement LED Energy saving 100 watt fitting IP 66 flood light luminaire of pressure die cast aluminium housing with toughned glass visor, having efficacy 100 lumen/watt, 6500 K, PF >0.90, 10 KV SPD with fixing arrangement made out of MS flat 25x4 mm with suitable size nut,bolt and washer in existing pole/biulding including welding in pole /grouting work in wall complete all as specified and directed by Engr-in-Charge. Make-Crompton Cat No CFS-504-100-57-NL-SL-GL-NSG or equivalant in Phillips ,HAVELLS, Orient and Wipro
M & L for taking down of old Flame proof MH / HPMV High bay / Bulk head lights of capacity 400 Watt installed on wall / roof etc and Supply, fixing in replacement and testing Flame Proof LED High Bay light fitting sunflower type of 100 Watt, Make : Shyam CAT Part No. SSPL/1251, CMRI certified well glass fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group :, IIA & IIIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed, dust and water proof with IP 65 protection and having terminals for looping of cables, M20 type cable entry ( for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / hang from ceiling with the help hook and nut / bolt / metal structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case, LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened, type "A". The luminaries shall be monolithic construction as per IS 16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10 ºC to 45 ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed.
M & L for taking down of old Flame proof MH / HPMV High bay / Bulk head lights of capacity 400 Watt installed on wall / roof etc and Supply, fixing in replacement and testing Flame Proof LED High Bay light fitting sunflower type of 70 Watt, Make : Shyam CAT Part No. SSPL/1233, CMRI certified well glass fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group :, IIA & IIIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed, dust and water proof with IP 65 protection and having terminals for looping of cables, M20 type cable entry ( for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / hang from ceiling with the help hook and nut / bolt / metal structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case, LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened, type "A". The luminaries shall be monolithic construction as per IS 16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10 ºC to 45 ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed.
M & L for taking down of old Flame proof MH / HPMV High bay / Bulk head lights of capacity 400 Watt installed on wall / roof etc and Supply, fixing in replacement and testing Flame Proof LED High Bay light fitting sunflower type of 40/50 Watt, Make : Shyam CAT Part No. SSPL/1233, CMRI certified well glass fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group :, IIA & IIIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed, dust and water proof with IP 65 protection and having terminals for looping of cables, M20 type cable entry ( for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / hang from ceiling with the help hook and nut / bolt / metal structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case, LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened, type "A". The luminaries shall be monolithic construction as per IS 16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10 ºC to 45 ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed.
M & L for taking down of old Flame proof 2x10Watt tube lights installed on wall /roof (as per existing fiting including all required assecories) etc and Supply, fixing in replacement and testing Flame Proof LED High Bay light fitting sunflower type of 30 Watt, Make : Shyam CAT Part No. SSPL/1233, CMRI certified well glass fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group : IIA & IIIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed, dust and water proof with IP 65 protection and having terminals for looping of cables, M20 type cable entry ( for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / hang from ceiling with the help hook and nut / bolt / metal structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case, LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened, type "A". The luminaries shall be monolithic construction as per IS 16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10 ºC to 45 ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed.
M & L for taking down of old Flame proof MH / HPMV High bay / Bulk head lights of capacity 70 Watt installed on wall / roof etc and Supply, fixing in replacement and testing Flame Proof LED Bulk head light fitting of 45 watt/50 Watt, CMRI certified fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group : IIA & IIIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed dust and water proof with IP 65 protection certified by CIMFR Dhanbad and having terminals for looping of cables M20 type cable entry (for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / mount on horizontal wall with the help of nut / bolt / metal column structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened type "A", Earthing 01 Nos inside 1 outside The luminaries shall be monolithic construction as per IS-16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than 10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver, efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC, Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10ºC to 45ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified and directed.
M & L for taking down of old Flame proof Fluroscent Emergency lights of capacity 10 to 20 Watt installed on wall / roof etc and Supply, fixing in replacement and testing Flameproof/weatherproof LED Emergency Light fixture 20 WATT with 2 Hour Max Back Up, CMRI certified fitting including LED lamps & SLA rachargeable battery, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group : IIA & IIIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed dust and water proof with IP 65 protection certified by CIMFR Dhanbad and having terminals for looping of cables M20 type cable entry (for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / mount on horizontal wall with the help of nut / bolt / metal column structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened type "A", Earthing 01 Nos inside 1 outside The luminaries shall be monolithic construction as per IS-16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than 10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver, efficiency more than 85 % along with surge protector with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC, Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10ºC to 45ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified and directed.
Supply and Fixing in replacement flameproof FLP/WP Joint distribution Panel of suitable size as per manufacturer, AI die cast LM-6 metal enclousar, IP-65 ingress protection, Make - Shyam Cat no. SSPL/110 Gas Group - IIB , CIMFR certifed and all connected items and taking out old one all as specified and directed. The scope of work includes provision of the following :- (a) ON DOOR (i) Incomming MCCB, TPN FP, 125 Amp, 25 KA with extended rotary handle - 01 (ii) Outgoing MCB, TPN FP, 63 Amp, 10 KA - 05 (ii) Outgoing MCB, TPN FP, 32 Amp, 10 KA - 05 (iii) Outgoing MCB,SP, FP, 32 Amp, 10 KA - 06 (b) ON Mounting Plate (i) Copper Bus Bar suitable capacity - 04 Nos (ii) Internal Wiring - As required (iii) Mechanical Couplings - 02 Nos (iv) Cable entry bottom side - as per cable schedule
Supply and Fixing in replacement flameproof distribution board of suitable size as per manufacturer, AI die cast LM-6 metal enclousar, Make - Shyam Cat no. SSPL/RCB/109, IP-65 Gas Group - IIA/IIB, CIMFR certifed and all connected items and taking out old one all as specified and directed. The scope of work includes provision of the following :- (a) ON DOOR (i) Incomming MCB, TPN FP, 63 Amp, 10 KA - 01 Nos (ii) Outgoing MCB, SP, FP, 6 Amp, 10 KA - 12 (b) ON Mounting Plate (i) Tinned Copper Bus Bar - 04 Nos (ii) Terminals (16 Sqmm Busbar type) - 04 (iii) Terminals (4 Sqmm screw type) - 24 (v) Internal Wiring - As required (vi) Labels - LOT (vii) Cable entry bottom side - as per cable schedule
M & L for taking down of Flame proof 4 feet tubelight light fitting of capacity 36W/ 40W installed on wall / roof etc and opening the fitting cover / bottom by removing of nut / bolts / screws etc , making necessary modification / bypass arrangement for fitting of LED 20 Watt T8 retrofit fitting complete including replacement of old flurocent lamp holder / bipin holder G13 push type by new G13 push holder on both side and Supply, fixing in replacement and testing new 4 feet LED 20Watt lamp, T8 retrofit, two pin on both side, including driver length 4 feet operating voltage range 220-240 V, AC, frequency 50 Hz, CRI> 80%, inbuilt surge protection and SMPS based driver ,CCT 6500K, frosted glass having as per IS-16102-1 (2012) with latest amendments and input voltage, P.F should be more than 0.9 with total harmonic distortion (THD) less than 10%, cool white colour . LED lamp should be suitable for ambient temperature from -10 ºC to 45 º and humidity level 10% to 90% RH. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report. After modification /replacement, re fixing the same Flame proof tube light fitting on original place and position etc complete all as specified & as directed.
M & L for taking down of Flame proof Bulk head light fitting of capacity 24W installed on wall / roof etc and opening the fitting cover / bottom by removing of nut / bolts / screws etc, making necessary modification for fitting of LED bulb of capacity 15W including replacement of B22 type bulb holder by new one batten bulb holder and Supply, fixing in replacement and testing old lamp by new LED lamp of capacity 15 W, base B22, including driver operating voltage range 140 V-270 V, AC, frequency 50 Hz, CRI> 80%, , inbuilt surge protection and SMPS based driver , CCT 6500K, frosted glass as per IS-16102-1 (2012) with latest amendments and input voltage. P.F should be more than 0.9 with total harmonic distortions (THD) less than 10%, cool white colour . LED lamp should be suitable for ambient temperature from -10 ºC to 45 º C and humidity level 10% to 90% RH. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report. After modification / replacement , re-fixing the same Flame proof Bulk head fitting on original place and position etc complete all as specified & as directed. Make : Shyam/Balinga or equivalent.
M & L for taking down of Flame proof 2 feet / 2.5 feet tubelight light fitting of capacity 36W installed on wall / roof and opening the fitting cover / bottom by removing of nut / bolts / screws, making necessary modification for fitting of LED PL-L light of capacity 18 Watt including replacement of old florescent PL light type light holder by new 2G11 type holder and Supply, fixing in replacement and testing new LED PL-L lamp of capacity 18W base 2G11 , four pin, length 419 mm, width 44 mm, height 29 mm, operating voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, inbuilt surge protection and SMPS based driver , CCT 6500K , frosted glass as per IS-16102-1 (2012), light colour warm white 6500K, frosted glass as per IS-16102-1 (2012) with latest amendments and input voltage P.F should be more than 0.9 with total harmonic distoration (THD) less than 10%, cool white colour and LED lamps hould be suitable for ambient temperature from -10ºC to 45ºC and humidity level 10% to 90% RH. The efficiency of LED luminaries system be more than 130 lumens per watt and must be certified by the LM-79 test report. After modification/ replacement, re-fixing the same Flame proof tube light fitting on original place and position etc complete all as specified & as directed. Make : Shyam/Balinga or equivalent.
Supply, fixing in replacement and testing Flame Proof LED light fitting 1 x 20 Watt including LED lamp/tube complete, CMRI certified suitable for fixation on wall/roof with LED tube light fixtures driver,holders, connector etc, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group :, IIA & IIIB, Zone 1 & 2, Tempclass T5 / T6, totally enclosed, dust and water proof with IP 65 protection and having terminals for looping of cables, M20 type cable entry ( for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / hang from ceiling with the help hook and nut / bolt / metal structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case, LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened, type "A". The luminaries shall be monolithic construction as per IS 16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10 ºC to 45 ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed.
Supply, fixing in replacement and testing Flame Proof LED light fitting 2 x 20 Watt including LED lamp/tube complete, CMRI certified suitable for fixation on wall/roof with LED tube light fixtures driver,holders, connector etc, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group :, IIA & IIIB, Zone 1 & 2, Tempclass T5 / T6, totally enclosed, dust and water proof with IP 65 protection and having terminals for looping of cables, M20 type cable entry ( for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / hang from ceiling with the help hook and nut / bolt / metal structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case, LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened, type "A". The luminaries shall be monolithic construction as per IS 16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10 ºC to 45 ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed.
S&F in replacement Switch Flame proof rotary type with termination box in LM6, 16 A, single pole with termination chamber 230V all as specified and directed by Engineer-in-Charge
S&F in replacement Switch Flame proof rotary type with termination box in LM6, 16 A, double pole with termination chamber 230V all as specified and directed by Engineer-in-Charge
S&F in replacement flame proof push button with indicator with termination box in LM6, with termination chamber 230V all as specified and directed by Engineer-in-Charge.
Supply & Fix in replacement of ELCB/RCCB capacity 63 Amps 100mA three phase having charastics IEC 61008-1 Im-1000A, LNC-10000A 4 pole having single Knob for on off test switch, all as directed by Engineer-inCharge. Make - L&T model BGB 406310 / ABB/Havells
Supply and fix in replacement flame proof switch Knob made of Ceramic / plastic to be fixed on Flame proof MCB DB box for operating the MCB ON/OFF all as directed by Engineer-in-Charge.
Material and labour for dismantling old earthing of any type. Supply, installation, testing of advanced maintenance free environment friendly CPRI approved earthing 10 feet long 17 mm dia earth electrode made high tensile low carbon steel circular rods, molecular bonded copper on outer surface (minimum copper bonded thickness 250 micron) with terminal to connect incoming copper strip 25 x 3 mm earthing strips with the equipment/machinery of desired length as per site requirement with 02 bags (25 Kg each) of environment friendly backfill compound with ROHS test certificate for each. The remaining space will be filled with soil and top of earth pit covered with high density polymer.Earth pit chamber cover of dimension (300 mm x 300 mm x 214 mm) with locking seal as to achieve the desired ohmic value complete all as specified and directed. Note : (i) Payment will be released only after the resistance value achieved less than 1 ohm. If value of resistance found more than 1 ohm contractor will do the fresh earthing without any extra cost. (ii) Rate of Copper strip 25x3 mm from earthing terminal to equipment/machinery with suitable size nuts/bolts and washers is deemed to be included in rate quoted by tendrer.
Supply and fix in replacement of Flame proof switch socket & plug combined in LM6 cable termination box in LM6, Gas group - IIA, IIB , Zone 1 & 2, IP-66 and 32A, 250V, 5 pole (4P+earth), Cable entries - 02 Nos etc complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of Flame proof switch socket & plug combined in LM6 cable termination box in LM6, Gas group - IIA, IIB , Zone 1 & 2, IP-66 and 63A, 250V, 5 pole (4P+earth), Cable entries - 02 Nos etc complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of flame proof fan regulator with following specifications :- (a) Dimension : 98x98x130mm (b) Cable entries 3/4'' ET - 02 Nos (c) Construction of Material - AI Die Cast LM6 (d) Area of classification - Zone-1 & 2 (e) IP - 65 (f) Certification - CIMFR & PESO Make - Shyam Cat No. SSPL/2C/1010 or Balinga or Sudhir or equivalent
M&L for taking down carefully existing unsv/broken flame proof submain wiring from existing conduit laid in wall & ceiling with disconnecting different connection of Flame proof light fittings including new flame proof Sub Main wiring for flame proof, zone I & II, Gas Group II A/II B, weather proof point wiring using single run PVC FRLS grade Insulated unsheathed, multistrand copper conductor cable 2 runs of 2.5 Sqmm for phase and neutral and 1 run of 2.5 Sqmm for earth wire drawn through existing concealed conduit wiring and connect with all existing flame proof fittings and DB as per site all as directed by Engr-in-charge. (Note:- Phase should be of Red /Yellow/Blue, neutral should be of back and earthing wire should be of green colour. 2 runs of cable for phase/ neutral and 1 run for earth will be measured and paid as one unit length).
M&L for taking down old unsv/non functional drivers (any type) of LED flame proof light fittings (any type) fittrd on wall/ceiling completely and repair the same with new LED Driver 45 Watt capacity including making functional with all required work all as specified and directed by Engr-in-charge.
M & L for taking down old broken/bend aluminium strip of any size from wall/ceiling/any location along with insulators and straighting carefully without braking and refixing same with insulator and nut/bolts after jointing broken portion/make staight the bend portion (align well for proper fitting) by nut and bolts all as directed by Engineer-in-Charge.
M & L for taking down old broken/bend copper strip of any size from wall/ceiling/any location along with insulators and straighting carefully without braking and refixing same with insulator and nut/bolts after jointing broken portion/make staight the bend portion (align well for proper fitting) by nut and bolts all as directed by Engineer-in-Charge.
M & L for taking down old broken ceramic/plastic insulator of any size and supply and fix in replacement ceramic insulator along with nut and bolts for fixing copper/ aluminium strip of size 20 x 3 mm on wall/ roof/ floor all as specified and directed by Engineer-in-Charge.
M & L for taking down old broken ceramic/plastic insulator of any size and supply and fix in replacement PVC insulator along with nut and bolts for fixing copper/ aluminium strip of size 20 x 3 mm on wall/ roof/ floor all as specified and directed by Engineer-in-Charge.
M/S SHREE SHYAM TRADERS (BID ID -3490367)
V.K. Infra Engineering (BID ID -3496147)
BALAJI PROJECTS (BID ID -3496055)
BIDAWAT ENTERPRISES (BID ID -3490559)
HINGLAZ ENTERPRISES (BID ID -3492377)
Aman Corporation (BID ID -3490080)
ALPHA ENGINEERING COMPANY (BID ID -3490546)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
BOQ_829706.xls
BOQ • 0.41 MB
Tenderdocument26.pdf
Tender Documents • 1.27 MB
Download all tender documents and submit your bid