Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.9 L+₹2,618 (0.14%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹21.0 L+₹2.2 L (11.5%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹21.5 L+₹2.6 L (13.8%)Rejected-Finance R S PURA NEW PLOT SALEHAR R S PURA JAMMU JAMMU JAMMU KASHMIR 181111 | JAMMU | JAMMU AND KASHMIR | 181111 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹21.5 L+₹2.6 L (13.8%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | Hi Tech Engineers L3 | CELMAC REGD L7 | M/S DC CONSTRUCTIONS L2 | ASHOKKUMAR SURI L6 | Warne Builders L1 | HARSH ELECTRICAL STORE L4 | M/S RAJ ENGINEERS L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth in any type of soil for laying of cables, pipes etc. and getting out complete all as specified and directed . | 577.8 | Cum | 100 ₹57,780 | 220 ₹1,27,116 | 100 ₹57,780 | 120 ₹69,336 | 80 ₹46,224 Lowest | 100 ₹57,780 | 90 ₹52,002 |
| 2.00 | Disconnecting & taking out defective under ground cable of any size from trenches, pole, pipe, floor, wall etc and removing from site complete all as specified and directed.
Note:- Excavation & earth work shall be measured & paid separately | 2,140 | RM | 3 ₹6,420 Lowest | 15 ₹32,100 | 10 ₹21,400 | 10 ₹21,400 | 5 ₹10,700 | 20 ₹42,800 | 5 ₹10,700 |
| 3.00 | M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed.
Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment. | 173.34 | Cum | 300 ₹52,002 | 780 ₹1,35,205.2 | 250 ₹43,335 | 450 ₹78,003 | 250 ₹43,335 | 200 ₹34,668 Lowest | 300 ₹52,002 |
| 4.00 | Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed. | 12,840 | Each | 20 ₹2,56,800 | 22 ₹2,82,480 | 14 ₹1,79,760 | 22 ₹2,82,480 | 15 ₹1,92,600 | 4 ₹51,360 Lowest | 9 ₹1,15,560 |
| 5.00 | Returning, filling in, including spreading, leveling ,watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and directed . | 381.35 | Cum | 15 ₹5,720.25 | 90 ₹34,321.5 | 100 ₹38,135 | 30 ₹11,440.5 | 20 ₹7,627 | 30 ₹11,440.5 | 3 ₹1,144.05 Lowest |
| 6.00 | Removing excavated material or surplus soil to a distance not exc 50 meter and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed . | 196.45 | Cum | 15 ₹2,946.75 | 90 ₹17,680.5 | 100 ₹19,645 | 30 ₹5,893.5 | 20 ₹3,929 | 30 ₹5,893.5 | 3 ₹589.35 Lowest |
| 7.00 | Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 10 Sqmm, 2 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed.
Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. . | 100 | RM | 75 ₹7,500 Lowest | 140 ₹14,000 | 80 ₹8,000 | 90 ₹9,000 | 75 ₹7,500 Lowest | 160 ₹16,000 | 90 ₹9,000 |
| 8.00 | Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 10 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed.
Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. . | 100 | RM | 92 ₹9,200 Lowest | 160 ₹16,000 | 110 ₹11,000 | 150 ₹15,000 | 105 ₹10,500 | 180 ₹18,000 | 130 ₹13,000 |
| 9.00 | Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm, 2 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed.
Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. . | 100 | RM | 85 ₹8,500 | 170 ₹17,000 | 95 ₹9,500 | 120 ₹12,000 | 80 ₹8,000 Lowest | 165 ₹16,500 | 110 ₹11,000 |
| 10.00 | Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed.
Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. . | 200 | RM | 100 ₹20,000 Lowest | 184 ₹36,800 | 120 ₹24,000 | 235 ₹47,000 | 130 ₹26,000 | 200 ₹40,000 | 160 ₹32,000 |
Tender Value
₹26.2 L
EMD Value
₹52,400
Closing Date
9 May 2026, 6:00 pmClosed
GE SATWARI
GE SATWARI
Spl repair to LT cable network and allied services at MH under GE Satwari
2026_MES_760871_1
GEJM-04/2026-27
Open Tender
Electrical and Maintenance Works
Works
180 days
GE SATWARI
Class D Cat b(i)
9 documents required · 9 mandatory
₹500
GE SATWARI
₹52,400
Yes
10 Jul 2026
18 Apr 2026
11 May 2026
18 Apr 2026
9 May 2026
2 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth in any type of soil for laying of cables, pipes etc. and getting out complete all as specified and directed . | - | Cum | - | - |
| 2 | Disconnecting & taking out defective under ground cable of any size from trenches, pole, pipe, floor, wall etc and removing from site complete all as specified and directed.
Note:- Excavation & earth work shall be measured & paid separately | - | RM | - | - |
| 3 | M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed.
Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment. | - | Cum | - | - |
| 4 | Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed. | - | Each | - | - |
| 5 | Returning, filling in, including spreading, leveling ,watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and directed . | - | Cum | - | - |
| 6 | Removing excavated material or surplus soil to a distance not exc 50 meter and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed . | - | Cum | - | - |
| 7 | Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 10 Sqmm, 2 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed.
Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. . | - | RM | - | - |
| 8 | Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 10 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed.
Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. . | - | RM | - | - |
| 9 | Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm, 2 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed.
Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. . | - | RM | - | - |
| 10 | Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed.
Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. . | - | RM | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tender04.pdf
Tender Documents • 1.02 MB
BOQ_852280.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .