Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52.9 LAccepted-AOC AT PO GURUJANG PS TALCHER ANGUL ODISHA PIN 759100 | GURUJANG | ANGUL | ODISHA | 759100 | ₹52.9 L | L1 | Accepted-AOC techno-commercially eligible L-1 bidder. |
| 2 | L2₹55.1 L+₹2.2 L (4.12%)Rejected-Finance AT PO REMUAN TALCHER DIST ANGUL ODISHA 759100 | TALCHER | ANGUL | ODISHA | 759100 | ₹55.1 L+₹2.2 L (4.12%) | L2 | Rejected-Finance Rejected due to not becoming techno-commercially eligible L-1 bidder. |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically not eligible for opening Price Bid. |
Tender Value
₹70.7 L
EMD Value
₹88,400
Closing Date
18 Jun 2024, 5:00 pmClosed
STAFF OFFICER (ENM), HINGULA AREA
STAFF OFFICER(ENM), OFFICE OF THE GM HINGULA AREA, MCL, TALCHERPO NS NAGAR, ANGUL, ODISHA, 759148
Erection of 6.6 kV Feeder Line emanating from 33 kV/6.6 kV substation and supplying power to last active area of projects Quarry as new additional feeder.
2024_MCL_309205_1
MCL/GM/HA/EnM/ e-Tender/24-25/81 Dt.28.05.24
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
HINGULA OCP
AS PER NIT
6 documents required · 6 mandatory
₹88,400
12 Oct 2024
29 May 2024
21 Jun 2024
29 May 2024
18 Jun 2024
30 May 2024
29 May 2024 - 5 Jun 2024
Amount
Item Description/ Heading
Erection of metallic pole of length (Above 11 meter and up to 13 meter) in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/22KV/33KV overhead line as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) Pole top bracket/ Cross arm for single 11 kV overhead line conductorcomplete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of Pole top /straight two wire/V-shape wire / angle iron / channel iron cross arm on steel tubular /Rail/Channel iron / PCC pole for 11KV/22KV/33KV as required.
Supplying and Erection of 11 KV polymer Disc insulator for 11 kV overhead lines with galvanised insulator fittings, ball and socket type and complete with galvanized strain clamps, bolts, nuts, washer etc. as required.
Supplyiing and erection of 11 kV grade Pin Insulator (Polymer) With Large head G.I. Pin, nuts, washers etc. as required .
Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required.
Supplying and erection of galvanised stay set for 33 kV over head lines completewith 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle (20 mm X 600 mm), 7/4.00 mm dia G. I. stay wire and 33 kV strain insulator etc. in cement concrete 1 :3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required
Erection of Cradle Guards
Earthing with G.I. earth pipe, 4.5 meter long 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying of G.I. Wire (6 SWG)
Clamp, Bolts, Nuts etc. ( For earth wire erection in every span)
Erection of Earth Wire
Gang Operating Air Break switch DOUBLE BREAK, 11KV, 1250A
Erection of 11kV, 630A GOAB switch Set-up Horaizontal / Vertical type with supplying and fabrication of iron & steel complete etc as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 kV overhead lines with rated voltage 9 kV (rms) with a nominal discharge current rating of 5 kA and complete with galvanised clamping arrangement, G.l. bolts, nuts, washers etc. as required.
Suppying of Channel 65mm X65 mmX 6 mm angle iron for Trapezium type structure making and Erection on the Pole
Two coats of Aluminium Painting of steel tubular pole
Supplying and Erection of HT Danger Notice board in the Pole structure.
Erection of Barbed wire as Anti-Climbing Device on the pole body
Suppy and erection of a set of cross bracing FRLSame work for 11kV overhead line double pole structures having four members fabricated out of 50 mm X 50 mmX 6 mm angle iron to form a rectangleof minimun size 1400 mm width and 25 mm height, complete with 50 mm X 6 mm MS flate iron clamps, bolts and nuts including drilling holes for insulator pins, bolt and nut ctc and priting with primer andfinish paint as recquired.
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
MESSERS UTKAL ELECTRICALS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .